visionLINE VL-VESTA-50, VL-VESTA-70 Deep Fully Recessed Electric Fireplace Owner’s Manual
- June 10, 2024
- VisionLine
Table of Contents
- visionLINE VL-VESTA-50, VL-VESTA-70 Deep Fully Recessed Electric
- IMPORTANT SAFETY INFORMATION!
- Preparation
- Parts and Hardware
- Installation and Assembly
- Wall Recessed Installation
- Wall Mounted Installation
- Operation
- REMOTE CONTROL
- Care and Maintenance
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
visionLINE VL-VESTA-50, VL-VESTA-70 Deep Fully Recessed Electric
Fireplace
Product Information
The Deep Fully Recessed Electric Fireplace is available in two models – VL-
VESTA-50 and VL-VESTA-70. It is a wall-mounted/recessed electric fireplace
that requires AC 220-240V 50Hz 1400-1600W power supply. The product is
designed for indoor and outdoor use and is not intended to be a primary heat
source. It is for supplemental
heat only.
Usage Instructions
- Before using the product, read the entire owner’s manual, including all safety information. Failure to do so could result in fire, electric shock, or serious personal injury.
- Do not operate the fireplace with a damaged cord or plug or after the fireplace malfunctions, has been dropped, or damaged in any manner. If the product is damaged, discard it or return it to an authorized service facility for examination and/or repair.
- Connect the product to properly grounded outlets ONLY. Do not insert or allow foreign objects to enter any ventilation or exhaust opening, as this may cause electric shock or fire, or damage the fireplace. To prevent a possible fire, do not block air intakes or exhaust in any manner. Doing so could cause a fire. Do not use on soft surfaces, like a bed, where openings may become blocked.
- Avoid fire by regularly inspecting all air vents to make sure they are free from dust, lint, or other blockage. Unplug the unit and clean with a vacuum ONLY. Do not rinse or get wet. Never hang this unit on a wall directly below an electrical outlet and never permanently install it in a recessed area of the wall. This may result in blocked airflow, overheating, or fire. Always mount it to the wall bracket before use and never set it on the floor or other surface to use.
- Never leave the fireplace unattended and always unplug it when not in use. Only use it on a 220-240V AC 10-Amp grounded circuit and never overload the circuit. The product is not recommended for commercial use and any commercial or public use of this fireplace voids all warranties and could cause injury.
50”/ 70”- Wall Mounted/Recessed Electric Fireplace
AC 220-240V 50Hz 1400-1600W
WARNING
Read and understand this entire owner’s manual, including all safety
information, before plugging in or using this product. Failure to do so could
result in fire, electric shock, or serious personal injury.
CAUTION
Keep this owner’s manual for future reference. If you sell or give this
product away, make sure this manual accompanies this product.
IMPORTANT SAFETY INFORMATION!
WARNING
- Read all instructions before using this fireplace!
- DO NOT operate any fireplace with a damaged cord or plug or after the fireplace malfunctions, has been dropped or damaged in any manner. Discard fireplace, or return to authorized service facility for examination and/or repair.
- DO NOT run power cord under carpeting. DO NOT cover power cord with throw rugs, runners, or similar coverings. DO NOT route power cord under furniture or appliances. Arrange power cord away from traffic area, and where it will not be tripped over.
- Connect to properly grounded outlets ONLY.
- DO NOT insert or allow foreign objects to enter any ventilation or exhaust opening, as this may cause electric shock or fire, or damage the fireplace.
- To prevent a possible fire, DO NOT block air intakes or exhaust in any manner. Doing so could cause a fire. DO NOT use on soft surfaces, like a bed, where openings may become blocked.
- A fireplace has hot and arcing or sparking parts inside. DO NOT use it in areas where gasoline, paint, or flammable liquids are used or stored.
- Use this fireplace only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
- AVOID FIRE! Regularly inspect all air vents to make sure they are free from dust, lint, or other blockage. Unplug the unit and clean with a vacuum ONLY. DO NOT rinse or get wet.
- NEVER hang this unit on a wall directly below an electrical outlet.
- NEVER permanently install in a recessed area of the wall. This may result in blocked airflow, overheating, or fire.
- ALWAYS mount to wall bracket before use. DO NOT set on the floor, or another surface, to use.
- NEVER use a wall mount bracket from another manufacturer.
- For residential use only! NOT for commercial use! Any commercial or public use of this fireplace voids all warranties, and could cause injury.
- This product is not intended to be a primary heat source. It is for supplemental heat only.
- INDOOR and OUTDOOR use!
- Risk of electric shock! DO NOT OPEN! No user-serviceable parts inside!
- NEVER modify this fireplace. Doing so could result in personal injury or property damage. Modification of this fireplace completely voids all warranties.
- ALWAYS turn this fireplace off before unplugging it from the outlet.
- ALWAYS disconnect this unit from the power supply before performing any assembly or cleaning, or before relocating the electric fireplace.
- NEVER leave this fireplace unattended. ALWAYS unplug this fireplace when not in use.
- ONLY use this fireplace on a 220-240V AC 10-Amp grounded circuit. NEVER overload the circuit. If this fireplace trips the circuit breaker, unplug all other appliances on the same circuit before the next use. Avoid plugging other appliances into the same circuit as this fireplace.
- NEVER plug this fireplace into an outlet that is old, cracked, or has any loose wires or connections. Plugging this fireplace into a faulty outlet could result in electric arcing within the outlet that could cause the outlet to overheat or catch fire.
- ALWAYS check your fireplace cord and plug connections with each use!
- MAKE SURE the plug fits tight in the outlet! Faulty wall outlet connections or loose plugs can cause the outlet to overheat.
- fireplaces draw more current than small appliances. Overheating may occur even if it has not occurred with the use of other appliances.
- During use check frequently to see if the plug outlet or faceplate is HOT!
- If the outlet or faceplate is HOT, discontinue use immediately and have a qualified electrician inspect and/or replace the faulty outlets.
- SAVE THESE INSTRUCTIONS!
Preparation
This product includes a GLASS panel! Always use extreme caution when handling glass. Failure to do so could result in personal injury or property damage.
Remove all parts and hardware from the carton and place them on a clean, soft,
dry surface. Parts and assembly steps are grouped for free-standing or wall-
hanging use. Check the parts list to make sure nothing is missing. Dispose of
packaging materials properly. Please recycle whenever possible.
You will need the following tools (not included): Phillips screwdriver; stud
finder; level; tape measure; electric drill; 1/4” wood drill bit, hammer.
Parts and Hardware
Installation and Assembly
ALWAYS unplug this fireplace before assembly or cleaning, or before relocating. Failure to do so could result in electric shock, fire, or personal injury.
Wall Recessed Installation
STEP 1. Select a drywall to open a hole for the fireplace box. Size of holes as below chart
STEP 2. Place the fireplace to a soft clean place. using the screw driver to take off the TWO screws in both sides. Figure (B)
STEP 3. Have two adults to pull the trim up, then take them out of the fireplace box. Figure (C)
STEP 4. Using the screwdriver to take off the 2 screws as above Figure
(D), have two adults to take out the glass panel Figure (E) and move it to a
clean soft place to avoid the scratching.
NOTICE: If you prefer initial ember bed, you can skip this step.
STEP 5. Have two adults to lift the fireplace box and put it into the opened hole. Fixing the FOUR wall screws in each side of the fireplace box. Figure (F)
STEP 6. Place the Decorative Crystals or Pebbles on the designed slot and even with them,Figure (G)
STEP 7. After Placing the decorative crystals and Drift log pieces on the designed slot and even with them from side to side . Move and screw back the glass panel and metal trim. (Repeat as Fig B,C,D,E )
Wall Mounted Installation
STEP 1. Take off wall bracket from the behind of fireplace, and keep it for next step. sSee below Figure (A).
STEP 2. Fix wall bracket with Mounting screws (B) , Drywall Anchors(C), and spirit level (not included). Make sure wall bracket is horizontally fixed on wall. See Figure(B) and (C).
STEP 3. Hang fireplace on wall bracket by two adults. Make sure fireplace is securely hang on wall. See figure (D)
STEP 4. Take off one screw on the bottom of fireplace and fix L bracket(H) on bottom of fireplace with ST4x12 screw(I). Then fix L bracket on wall with Drywall anchor (C)and wood screw(B). See Figure (E) and (F).
Operation
Read and understand this entire owner’s manual, including all safety information, before plugging in or using this product. Failure to do so could result in electric shock, fire, serious injury, or death.
Power
Plug the power cord into a 220-240 Volt 10 Amp grounded outlet (see IMPORTANT
SAFETY INFORMATION on Pages 2 and 3). Make sure the outlet is in good
condition and that the plug is not loose. NEVER exceed the maximum amperage
for the circuit. DO NOT plug other appliances into the same circuit.
Methods of Operation
This electric fireplace can be operated by the TOUCH PANEL, located on the
right-side panel of the fireplace (see figure below), or by the battery-
powered
REMOTE CONTROL
The operation and functions of the two methods are the same.
Before operating, please review the IMPORTANT SAFETY INFORMATION on Pages 2
and 3, and heed all warnings.
Remote Control &Touch Panel Operation
NOTICE
When the fireplace is first turned on, a slight odor may be present. This is
normal and should not occur again unless the fireplace is not used for a long
period of time.
NOTICE
To improve operation, aim the remote control at the front of the fireplace. DO
NOT press the buttons too quickly. Give the unit time to respond to each
command.
Temperature Limiting Control
This heater is equipped with a Temperature Limiting Control. Should the heater
reach an unsafe temperature, the heater will automatically turn OFF. To reset:
- Unplug the power cord from the outlet.
- Turn the ON/OFF switch on the CONTROL PANEL to OFF. Wait 5 minutes.
- Inspect the fireplace to make sure no vents are blocked, or clogged with dust or lint. If they are, use a vacuum to clean the vent areas.
- With the POWER switch in the OFF position, plug the power cord back into the outlet.
- If the problem continues, have your outlet and wiring inspected by a professional.
Remote Control Battery Information
- This remote control uses CR2025 battery (included).
- Instructions for battery installation are on the Remote Control battery compartment.
NEVER dispose of batteries in fire. Failure to observe this precaution may result in an explosion. Dispose of batteries at your local hazardous material processing center.
Care and Maintenance
Cleaning
- ALWAYS turn the fireplace OFF and unplug the power cord from the outlet before cleaning, performing maintenance, or moving this fireplace. Failure to do so could result in electric shock, fire, or personal injury.
- NEVER immerse in water or spray with water. Doing so could result in electric shock, fire, or personal injury.
Metal:
- Buff using a soft cloth, slightly dampened with a citrus oil-based product.
- DO NOT use brass polish or household cleaners as these products will damage the metal trim.
Glass:
- Use a good quality glass cleaner sprayed onto the cloth or towel. Dry thoroughly with a paper towel or lint-free cloth.
- NEVER use abrasive cleansers, liquid sprays, or any cleaner that could scratch the surface.
Vents:
- Use a vacuum or duster to remove dust and dirt from the fireplace and vent areas. Plastic:
- Wipe gently with a slightly damp cloth and a mild solution of dish soap and warm water.
- NEVER use abrasive cleansers, liquid sprays, or any cleaner that could scratch the surface.
Maintenance
Electrical and Moving Parts:
- The fan motors are lubricated at the factory and will not require lubrication.
- Electrical components are integrated in the fireplace and are not serviceable by the consumer.
Storage:
- Store fireplace in a clean dry place when not in use.
WARNING! NO SERVICING of the internal or electrical parts should be performed by the consumer. Do not service the unit yourself.
Visionline Fireplaces
444 Swan Street
Richmond Victoria AU
1300 219 875
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>