visionLINE V6 Taurus SS Freestanding Low Emission Burner Owner’s Manual
- September 20, 2024
- VisionLine
Table of Contents
V6 Taurus SS Freestanding Low Emission Burner
“`html
Specifications:
- Brand: VisionLINE Taurus
- Type: Freestanding Low Emission Burner
- Overall Average Efficiency: 61%
- Average Particulate Emission Factor: 1.3 G/KG
- Maximum Average Heat Output: 15.4 kW
- Catalytic Combustor: No
- Approved Fuel: Burn only hardwood with a moisture content less
than 20%
Product Usage Instructions:
Installation:
1. Contact your dealer for any questions regarding
installation.
2. Ensure compliance with AS/NZS2918 standards for
installation.
3. Secure the compliance tag to the unit with the supplied wire
for future access.
Operation:
1. Use only hardwood with moisture content less than 20% as the
fuel.
2. Follow the fireplace operation guidelines provided in the
manual.
3. Do not fit wetbacks as they are not approved options.
Cleaning and Maintenance:
1. Regularly clean and inspect the appliance as per the cleaning
& inspection guidelines in the manual.
2. Remove firebricks as needed for maintenance purposes.
FAQ:
Q: Can wetbacks be fitted to the burner?
A: No, wetbacks are not approved options for this appliance.
Q: What type of fuel is approved for use?
A: Only burn hardwood with a moisture content less than 20% in
this burner.
Q: What standards should be followed during installation?
A: Installations must comply with AS/NZS2918 standards and may
require a building consent.
“`
TAURUS – AU/NZ freestanding Low emission burner INSTALLATION AND OWNERS MANUAL
INSOTAWLNLEERR::
Leave this manual with party Retain this manual for future
responsible reference
for
use
and
operation
Contact your dealer with questions on installation, operation or service
V7
COMPLIANCE TAGS
Australian Compliance tag – sample
WOOD FIRE COMPLIANCE LABEL
This appliance has been TESTED TO AS/NZS4013 for Hardwood by ASFT Report. 20009 Date tested: FEBRUARY 2020
VisionLINE Taurus
OVERALL AVERAGE EFFICIENCY
Freestanding and Inbuilt
WHEN TESTED IN ACCORDANCE WITH AS/NZS 4012: 61%
AVERAGE PARTICULATE EMISSION FACTOR
WHEN TESTED IN ACCORDANCE WITH AS/NZS 4013: 1,3 G/KG
MAXIMUM AVERAGE HEAT OUTPUT
15,4 kW
CATALYTIC COMBUSTOR
NO
APPROVED FUEL:
BURN ONLY HARDWOOD WITH A MOISTURE CONTENT LESS THEN 20%
Wetback – All Models: Manufactured By:
Wetbacks are NOT an approved option and must not be fitted.
Burning Technology – Stupkova – 952/18, Nová Ulice, 77900, Olomouc – Czech
Republic EU
Serial No:/ BT 005E 001 5 6771 B
N° de série:
Date of Manufacture / Date de fabrication:
7038-200 R4
2023 2024 2025 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Made in The EU
New Zealand Compliance tag – sample
/ / INSTALLATION DATE:
WOODFIRE COMPLIANCE LABEL
This appliance has been TESTED TO AS/NZS4012/13 for Softwood by ASFT Report. 23048 Date tested: JULY 2023
VisionLINE Taurus SS
OVERALL AVERAGE EFFICIENCY
Freestanding
WHEN TESTED IN ACCORDANCE WITH AS/NZS 4014.2:..6..5…%…………..
AVERAGE PARTICULATE EMISSION FACTOR
WHEN TESTED IN ACCORDANCE WITH AS/NZS 4014.2:..1..,.0….g../.k.g……..
MAXIMUM AVERAGE HEAT OUTPUT……………………………..9…k..W……
RANGE OF AVERAGE HEAT OUTPUT …………………………..5…-…9…k..W…………
APPROVED FUEL: …………………………………………………………B..U…R…N…O…NLY SOFTWOOD WITH A MOISTURE
CONTENT LESS THEN 25%
EMISSION AVERAGE RATE……………………………………………7..6…m. g/MJ
Manufactured By: ……………………………………………………………B…u..r.n..i.n..g..Technology – Stupkova – 952/18, Nová Ulice, 77900, Olomouc – Czech Republic EU
Testing laboratory address: ………………………………………………A..u..s..t.r.a..l.i.a..n…S..o..l.i.d…F. uel Testing Laboratory, 3 Garden Street, Morwell, Victoria Australia 3840
Serial No:/ BT 005E 001 5 1560 B N° de série:
Date of Manufacture / Date de fabrication:
2023 2024 2025 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
ECAN authorisation number: CRC243463
Made in The EU
Performance may vary from test
/ / INSTALLATION DATE:
For insert or zero clearance installations, the compliance tag must be secured
to the unit with the supplied wire and positioned under the firebox for future
access.
1
Safety Alert Key: · DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. · WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. · CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. · NOTICE: Indicates practices which may cause damage to the appliance or to property.
Table of Contents
1. Sample of Serial Number / Safety Label 2. Table Of Contents 3. Appliance Dimensions 4. General Information 5. Hearth and Clearance provisions 7. Flue System Requirements 11. Insert Considerations 13. Install Checklist
14. Install Guide 17. 2918 General Notes 18. Fireplace Operation 20. Cleaning & Inspection 20. Firebrick Removal 21. Seismic Restraint 22. Fitting Heat Shield 23. Warranty Information
INSTALLATIONS TO COMPLY WITH AS/NZS2918 AND WILL REQUIRE A BUILDING CONSENT
IMPORTANT: Read all instructions carefully before starting installation.
Failure to follow these instructions may result in a fire hazard and will void
the warranty.
WARNING
Fire Risk. VisionLINE fireplaces disclaims any responsibility for, and the
warranty will be voided by, the following actions:
· Installation and use of any damaged appliance. · Modification of the
appliance. · Installation other than as instructed by VisionLINE
fireplaces. · Installation and/or use of any component part not
approved by VisionLINE fireplaces. · Operating appliance without fully
assembling all
components. · Do NOT Over fire – If appliance or chimney
connector glows, you are over firing.
Any such action that may cause a fire hazard.
WARNING
If the information in these instructions is not followed exactly, a fire could
result causing property damage, personal injury, or death.
· Do not store or use gasoline or other flammable vapours and liquids in the
vicinity of this or any other appliance.
· Do not over fire – If appliance or chimney connector glows, you are over
firing. Over firing will void your warranty.
· Comply with all minimum clearances to combustibles as specified. Failure to
comply may cause house fire.
2
967
APPLIANCE DIMENSIONS
281
567
800
Central AIR INTAKE 100mm
Ø172
Ø100mm
549
488 400
441
Central secondary tertiary AIR CONTROL
1042
496 441
846 474
441 196
54
1042
Heat shield and fans
IMPORTANT: Read all instructions carefully before starting installation.
Failure to follow these instructions may result in a fire hazard and will void
the warranty.
INSTALLATIONS TO COMPLY WITH AS/NZS2918 AND MAY REQUIRE A BUILDING CONSENT
Note:
· The Taurus firebox weighs approx. 310kg including base. · To safety lift the
unit onto the base for positioning, the unit should be stripped of as much
weight
as possible by removing all bricks, baffles and the door assembly. See page 21
· The top door hinge should be marked for it’s location prior to removal so it
can be re-assembled
easily into it’s correct location. If the door doesn’t locate into the latch
mechanism correctly adjustment is via the two bolts on the top hinge. See page
21 · Heat shield is required for optional fans and reduced clearance to
combustible walls. See page 22
3
GENERAL INFORMATION
WARNING
Fire Risk. For use with solid wood fuel only. Other fuels may over fire and
generate poisonous gases (i.e. carbon monoxide).
FAN PROVISION If optional fans are used, ensure there is provision for 2x
power points. Power cord requires a single 240v 10amp GPO each. To install
fans, use (not supplied) 10mm self tapping screws. Alternatives to the
Pedestal base is possible and should be constructed out of non-combustible
materials such as steel or natural stone. If placing at an elevated height
(100mm min) above the floor, refer to FIG 3 for hearth requirements and
clearances. The unit heat shield has 3 knockout points as per below. If
placing on an alternate base, the left and right knockout points should be
removed to elevate the fan position so as to not foul on the platform.
OUTSIDE AIR The Taurus can be connected to outside air via the central air
intake at the rear or base of the unit (See line drawings on previous page).
This can be via rigid or flexible connection to a vermin proof cap on the
exterior of the building. Remove central rear knockout point on the rear heat
shield in all situations except when using outside air through the lower air
intake. Please note: The outside air duct must be led outdoors or into a well-
ventilated room inside the building (cellar, utility room, etc.). FLOATING
HEARTH
For a floating hearth, consideration should be given to the usability of the
burn rate control handle due to the low position location. See example 1 & 2.
Nylon feet should remain on the unit for spacing off the hearth material.
Example 1
Knockout points
Optional fans should not be used within 45 minutes of starting the fireplace,
this allows the firebox to warm up prior to heat being pulled from the heat
exchanger. Using the optional fans prior will reduce the heat output of the
fire and delay the warm up process dramatically.
Please Note – Fans should be switched off when the fireplace door is opened.
Failure to do so may result in smoke being blown into the room.
Example 2
4
6-7MM
CLEARANCE REQUIREMENTS
The VisionLINE Taurus may require an insulating Floor Protector depending on the installation type. It is tested and complies with the minimum Floor Protector requirements of AS/NZS 2918. See below for Hearth specifications.
Note: · The minimum Floor Protector sizes are specified in the clearance chart, see FIG 1, 2 and 3.
· A Floor Protector can include ceramic tiles with grouted joints fixed directly onto a wooden floor or a Steel panel or any other non combustible material laid directly onto a wooden floor.
· If installed directly onto a concrete slab, the concrete slab can be considered as the floor protector, but must maintain the minimum measurement listed.
·
The Taurus must be bolted to the base from allen key bolts x4) and to the floor protector
the underside to comply with
osfetihsembicasrees(wtriathinstupprpolvieisdioMn 8ofcAonSe/NtaZpSer2e9d18
Notice: The pedestal base has M8 threaded shipping restraint holes which are recommended to be utilised to anchor to the hearth using (not supplied) 8mm masonry dynabolts
· If installation does not include one of the pedestal bases and positioned at a height as per fig 1, the unit will require to be secured to the hearth through the outer casing of the unit using (not supplied) 8mm masonry anchors. See page 21 for instructions on this procedure.
PARALLEL POSITIONING – min base height 100mm Fig. 1
Note: Installation minimum height to floor A minimum 440mm deep x 1040mm wide
x 100mm thick floor protector (Hebel Block) must be used under the appliance,
1230mm wide x 600mm deep x 42mm thick floor protector (compressed board) must
be used in front of the appliance base when installing the appliance. See
joint AS/NZS 2918 3.3.2. The floor protector should extend 600mm in front of
the appliance door and be placed centrally in the 1230mm width.
When installed on optional pedestal base, hearth projection minimum is 300mm. See fig 3.
Typical flue size for triple cased flue 150mm | 200mm | 250mm
Vertical clearance above the appliance of 1500mm to a combustible ceiling or bulk head to be maintained as per 2918 section 3.2.2
5
CLEARANCE REQUIREMENTS
A
A D
B
C E
When installed with optional rear heat shield behind the appliance, reduce to 200mm from the heat shield *
A
Height of unit Above Floor (mm)
100
200
300
400
B
Hearth Projection (mm)
600 530 425 300
Hearth Projection
C Thickness (mm)
42 20
6
6
D
Under unit thickness (mm)
100
20
6
6
Please note: 300mm hearth projection min. when using optional wood storage
base/pedestal
Vertical clearance above the appliance of 1500mm to a combustible ceiling or
bulk head to be maintained as per 2918 section 3.2.2
WARNING
Fire Risk. VisionLINE fireplaces disclaims any responsibility for, and the
warranty will be voided by, the following actions:
· Installation and use of any damaged appliance. · Modification of the
appliance. · Installation other than as instructed by VisionLINE
fireplaces. · Installation and/or use of any component part not approved
by VisionLINE fireplaces. · Operating appliance without fully assembling all
components. · Do NOT Over fire – If appliance or chimney connector glows,
you are over firing. Any such action that may cause a fire hazard.
6
FLUE SYSTEM
For flue system installation, please follow manufacturers instructions. Below relates specifically to the active flue connection.
Lower channel
The active 6″ flue seats over the flue starter spigot, the flue crimp will slide down and rest in the lower channel. Friction fitment secures the flue on the spigot, no sealant required. If active flue is found to be slack or loose, cut off the crimp on the first length to ensure air-tight fitment.
Flue spigot removal for demonstration purposes only. Not required for installation of the fireplace.
Flue seated correctly.
Typical flue size for triple cased flue 150mm | 200mm | 250mm
VisionLINE fireplaces recommends using VisionLINE Safety Vent AIR insulated flue kits.
MINIMUM HEIGHT OF FLUE SYSTEM EXIT
3000 – NZ ONLY 6000 – AU
3000 or less
More than 3000
600 min.
3000
increase as necessary until nothing within 6000mm of flue top (3000mm for NZ)
Any nearby structure
7
increase from 1000mm min until clear within 3000 of flue top
FLUE SYSTEM
Tested flue systems, as per AS/NZS 2918 – Australia (AS/NZS 2918)
8
FLUE SYSTEM
Tested flue systems, as per AS/NZS 2918:2001 – For New Zealand
9
FLUE SYSTEM
Untested flue systems, as per AS/NZS 2918:2001 & 2018 4.6.3(b)
10
MASONRY INSERT CONSIDERATIONS
Inserting the freestanding unit into a brick/hebel structure AS/NZS 2918 section 3.4.1.2 considerations are as follows. Top of the enclosure shall be capped, and the capping shall be at least 5mm thick steel plate or at least 12mm thick heat-resistant material. Where the flue system passes through the capping of the enclosure, the active flue shall be double cased and ventilated through the capping, the ventilation coming from inside the enclosure. The lower end of the casing shall be close fitting against the enclosure capping. The outer casing shall have clearances to heat-sensitive material of not less than 25mm. VisionLINE Safety Vent Air Flue can be used as an alternative to air cooled flue flue in this situation. If requiring outside air via this flue system, allow 100mm of extra cavity depth for the T-section and snorkel. A chimney chase structure shall have obstruction free, vermin proof air vents to supply obstruction free air both at the bottom and the top termination point in order to ventilate the chimney chase cavity. Fig 1 Ventilation openings of not less than 10 000 mm2 free space shall be provided near the base and the top of the enclosure. Flue casing ventilation shall not be considered part of the free space requirement. See following page for alternate cavity venting options There shall be no combustibles on top of the chimney chase termination. It is recommended to have a minimum 5-10mm gap around the sides and top of the fireplace to the masonry structure for expansion and contraction. If not using the Taurus FS base, this can be covered with the optional ZC-TRIM-TAURUS 4 sided 50mm trim if required as pictured below.
Fig 1
AIR VENT
REQUIREMENTS
ZC-TRIM-TAURUS
ILLUSTRATION ONLY – ACTUAL REQUIREMENTS MAY VARY
11
MASONRY INSERT CONSIDERATIONS
CAVITY VENTILATION OPTIONS
4
4
9
10
4
4
9
10
2 3
5
1
a) Exterior cavity
7
2 3
5
1
b) Interior cavity open to roof space
8 6
2 3
1
8 6
2 3
5
1
LEGEND 1. Appliance
2. Vented flue system with 2 casings
3. Flue system air inlet
4. Flue system air outlet
5. Bottom vent cool air inlet
6. Room vent interior hot air outlet
7. Ceiling vent vermin proof mesh
8. Vented ceiling penetration
5
9. Venting through casing
10. Top side vent to built-in structure
c) Interior cavity closed at ceiling
d) Interior cavity closed at ceiling and additional termination cavity
12
F. Install Checklist
ATTENTION INSSTTAALLLLEERR:
Follow this Standard Work Checklist
This standard work checklist is to be used by the installer in conjunction
with, not instead of, the instructions contained in this installation manual.
Customer:
Date Install: _L_ot/_A_d_d_r_e_ss: __ Location of App_li_a_nce:__I_n_s_ta_l_ler: ____ Dealer / Distributor Pho_ne#_:___Se_ri_al #_: Model:
WAR_N_I_NG!_Ris_ko_f_F_i_reo_r_E_x_p_l_o_s_io_n! _F_ai_lu_reto_i_n_st_a_ll _ap_p_li_a_nc_e_a_c_c_o_rd_in_g_t_o_th_e_s_e_in_s_tr_u_c_tio_n_c_a_n_l_ea_d_t_o_a_f_ir_e_o_r
____ex_p_lo_s_ion.__
Appliance Install
Verified clearances to combustibles. Appliance is level and connector is secured to appliance. Hearth extension size/height decided. Outside air kit installed. Floor protection requirements have been met. If appliance is connected to a masonry chimney, it should be cleaned and inspected by a professional. If installed to a factory built metal chimney, the chimney must be installed according to the manufacturer’s instructions and clearances.
YES
IF NO, WHY?
Chimney
Chimney configuration complies with diagrams. Chimney installed, locked and
secured in place with proper clearance. Chimney meets recommended height
requirements (14-16 feet). Roof flashing installed and sealed. Terminations
installed and sealed.
Clearances
Combustible materials not installed in non-combustible areas. Verified all
clearances meet installation manual requirements. Mantels and wall projections
comply with installation manual requirements. Protective hearth strips and
hearth extension installed per manual requirements.
Appliance Setup
All packaging and protective materials removed. Firebrick, baffle and ceramic
blanket installed correctly. All labels have been removed from the door. All
packaging materials are removed from inside/under the appliance. Manual bag
and all of its contents are removed from inside/under the appliance and given
to the party responsible for use and operation.
VisionLINE fireplaces recommends the following: · Photographing the installation and copying this checklist for your file. · That this checklist remain visible at all times on the appliance until the installation is complete.
Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed:
Comments communicated to party responsible ____ by ___ on _
(Builder / Gen. Contractor)
(Installer)
(Date)
13
Getting Started
Install Guide
14
To minimise the effects of negative air pressure: · Install optional outside
air kit with the intake facing
prevailing winds during the heating season · Ensure adequate outdoor air for
all combustion
appliances and exhaust equipment · Ensure furnace and air conditioning return
vents are
not located in the immediate vicinity of the appliance · Avoid installing the
appliance near doors, walkways
or small isolated spaces · Recessed lighting should be a “sealed can” design ·
Attic hatches weather stripped or sealed · Attic mounted duct work and air
handler joints and
seams taped or sealed · Basement installations should be avoided
WARNING
Fire Risk. VisionLINE fireplaces disclaims any responsibility for, and the
warranty will be voided by, the following actions:
· Installation and use of any damaged appliance. · Modification of the
appliance. · Installation other than as instructed by
VisionLINE fireplaces. · Installation and/or use of any component part not
approved by VisionLINE fireplaces. · Operating appliance without fully
assembling all
components. · Operating appliance without legs attached (if
supplied with appliance). · Do NOT Over fire – If appliance or chimney
connector glows, you are over firing. Any such action that may cause a fire
hazard.
D. Tools And Supplies Needed
Before beginning the installation be sure the following tools
and building supplies are available:
Reciprocating saw
Flat blade screwdriver
Framing material Pliers
Electric drill and bits
High temp caulking material
Plumb line
Hammer
Safety glasses
Gloves
Level
Phillips screwdriver
Tape measure
Framing square
Misc. screws and nails
10mm socket or
wrench
1/2-3/4 in. length, #6 or #8 self-drilling screws
E. Inspection of Appliance and Components
· Remove appliance and components from packaging and inspect for damage.
· Report to your dealer any parts damaged in shipment. · Read all the
instructions before starting the
installation. Follow these instructions carefully during the installation to
ensure maximum safety and benefit.
15
WARNING
Fire Risk. Inspect appliance and components for damage. Damaged parts may
impair safe operation. · Do NOT install damaged components. · Do NOT install
incomplete components. · Do NOT install substitute components. Report damaged
parts to dealer.
16
AS/NZS 2918 General Notes
WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH
AS/NZS 2918 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR
CODES.
WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY
WITH THE REQUIREMENTS OF AS/NZS 4013 WHERE REQUIRED BY THE REGULATORY
AUTHORITY, I.E. THE APPLIANCE SHALL BE IDENTIFIABLE BY A COMPLIANCE PLATE WITH
THE MARKING `TESTED TO AS/NZS 4013′.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE
TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR
COMPLIANCE WITH AS/NZS 4013.
CAUTION: MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES
OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN
HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE MANUFACTURER SHOULD
BE CONSULTED IN THE FIRST INSTANCE.
CAUTION: THIS APPLIANCE SHOULD NOT BE OPERATED WITH CRACKED AND BROKEN
COMPONENTS, e.g. GLASS PANELS OR CERAMIC TILES, MAY RENDER THE INSTALLATION
UNSAFE.
WARNING: ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN
WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS/NZS 4013.
WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE
FIRE.
WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS
APPLIANCE WHEN ITS OPERATING.
WARNING: DO NOT STORE FUEL WITHIN HEATER INSTALLATION CLEARANCES.
WARNING: OPEN AIR CONTROLS AND DAMPER WHEN FITTED BEFORE OPENING FIRING DOOR.
WARNING: FOR OPTIMUM PERFORMANCE FUEL MUST BE LOADED SO THE LOGS LAY “FRONT TO
REAR” IN PREFERENCE TO LAYING ACROSS THE WIDTH OF THE FIREBOX. SPACES SHOULD
BE LEFT BETWEEN THE LOGS TO ENABLE OXYGEN TO GET TO AS MUCH OF THE SURFACE OF
THE FUEL AS POSSIBLE.
CAUTION: THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN
ACCORDANCE WITH THESE INSTRUCTIONS.
CAUTION: THE USE OF SOME TYPES OF PRESERVATIVE-TREATED WOOD AS A FUEL CAN BE
HAZARDOUS.
17
Before lighting the first fire
If the stove was stored in a cold environment (car, store, etc.) before the
first lighting, keep it at room temperature for about 3 hours to equalise
moisture condensation and surface temperature of the parts. Otherwise, there
is a risk of damage to the glass or lining of the stove. During the first
lighting, the paint coating will go through a curing process. The stove paint
will emit an odour for at least 4 hours as it adheres to the steel. Ensure to
ventilate the room during this time.
Lighting your fire
Ensure the Air Slide is in the open or high position. (pulled out fully
towards you.
In firebox lay your fire lighters 10 to centimetres apart. Do not use
newspaper as a fire lighter.
Add a mixture of soft wood and hardwood kindling in a criss cross pattern
above the firelighters. Softwood kindling allows for fire to light quicker and
burn hotter, mixing in some kindling size hardwood helps the coals retain more
heat for longer.
Light fire with match or gas lighter, when fire is ablaze close the door,
but do not latch the door. Leave for 5-10 minutes maximum and do not leave
unattended.
Load pieces of hardwood that are no wider than a drink can in a criss cross
pattern.
Latch the door and leave latched for 30 minutes. If your heater has a fan,
do not run the fan for at least 45 minutes.
After 30 minutes add the large pieces of hardwood. These pieces should be no
bigger than a loaf of bread. Close and latch door after loading.
After 45 minutes you can adjust the air slide to slow fire down and find
your comfort level. If you have a fan fitted you can now turn it on.
If too little wood and firelighters are used during lighting or the pieces are
too large, the optimal operating temperature will not be reached. This can
lead to poor combustion, high soot formation and the extinguishing of the fire
after closing the door. Slow combustion fireplaces with wide door openings are
prone to smoke spillage occasionally when the door is opened during lighting
and reloading. This occurs due to a pressure imbalance when opening the door
as cool air rushes in. Avoid opening the door when there is visible smoke/
flame to reduce this symptom. It is good practice to only reload when fuel is
at coaling phase.
Good wood merchants will split the wood for you, but may not season it for
you. The amount of you pay for your wood or the appearance of the wood does
not justify how dry the wood is. The only way to know how dry your wood is, is
to use a moisture meter measuring from the inner core after splitting the
piece of wood you are testing. Only burn wood under 20% moisture. Anything
over 20% and your wood heater will not work efficiently. The energy from the
fire will be used to reduce moisture in your wood and not produce heat for
your house. Store your wood for at least 12 months after your have purchased
it. Optimum moisture content is between 15-18%. Wood under 15% will have a
shorter overall burn time than wood around 20%. Never burn treated wood or
painted wood.
Combustion air
The 3 elements required for fire are Fuel, Heat and Oxygen. When a fire is
started within a slow combustion heater, the heat rises in the flue system
creating a vacuum within the firebox. This vacuum creates positive pressure or
`draw’ which pulls oxygen in to replace itself and create the balance of air
to keep the fire running. In tightly sealed homes, fresh air supply to the
unit may be insufficient due to an air pressure imbalance which can affect the
operation of the stove. This stove has the possibility of connecting directly
to outside the envelope of the home to supply combustion air. This is via the
99mm diameter central air duct neck located on the rear of the unit. This can
be relocated to the base of the unit for outside air connection through the
sub floor. To ensure a central air supply, the duct must not be longer than 3
m and have too many bends. The minimum duct diameter is 80 mm. The central air
duct must be led outdoors or into a well-ventilated room inside the building
(cellar, utility room, etc.).
VAeniIsRsiuoinrnisLnuIgNlaaEtdefedirqefulpualeatecseaysisrtrseeumcpoptmolymcbreeanaldatesncatheb.eaVlaisnicoendLfINluEe
Tips on choosing firewood
How long a tree has been felled or dead for does not indicate how dry the wood
is. The best way to dry wood is to split it and expose the inner core allowing
the sun to dry the wood naturally.
18
CLEANING AND INSPECTION
Over firing the unit and continuously running the unit on high with an
overloaded firebox for extended periods of time can damage the unit. This
picture shows the firebox fully loaded. Note the red line which indicates a
gap between the loaded fuel and the baffle top and the clear path to the
tertiary air tube at the rear. Loading fuel which touches the roof baffle or
the rear tertiary air tube is considered to be overloaded and can result in
over-firing of the product causing damage to the unit and voiding the
warranty. It is recommended to inspect the fireplace and flue once a year
minimum including having the flue swept to remove any creosote build-up.
Before the heating season, thoroughly clean the entire fireplace from ash and
soot with a brush or a vacuum cleaner. Never use abrasive products to clean
the glass or metal parts as this may cause damage. Glass should only be
cleaned when the stove is cold. The surface of the stove can be cleaned with a
damp cloth or if necessary, with a mild soap solution. Any scratches or
blemishes to the finished paint surface can be touched up with a light sand
and Anthracite Grey high temp paint. For brick removal, see the following
steps
19
CLEANING AND INSPECTION
20
SEISMIC RESTRAINT
For seismic restraint purposes when not using the Taurus Pedestal Base, the
following is the firebox removal process. The steps below first require the
bricks and door to be removed as per previous pages of this instruction
manual. The self closing cable at the bottom of the door will need to first be
removed using a 10mm ring spanner to loosen the locking nut and bolt holding
thread. Ensure to hold the tension on the cable whilst removing the bolt and
once removed add the bolt and nut inside the cable loop so it doesn’t go
missing under the unit.
Note: Mark the door hinge location for easy re-fitting. Loosen front 10mm
positioning bolt first, then rear locking bolt whilst supporting the door.
Locate all 4 support bolts on the inner sides of the firebox and remove using hex 4 driver bit.
Loosen firebox tensioning bolt located in the middle at the top using 17mm open ended spanner.
Carefully slide the firebox out of the outer casing. This is best done whilst still bolted to the shipping crate.
The firebox will slide on the rails as pictured below.
21
For ease of re-fitting the firebox, the firebox shield on the rear can be removed by undoing 4x 10mm securing bolts
There are six pre-drilled seismic restraint holes in the floor of the casing to choose from and secure (not supplied) 8mm masonry anchors (if applicable)
For reassembly, follow these steps in reverse.
Installing Rear Heat Shield
· Remove the 4x 10mm bolts holding the internal shield onto the fireplace and
place (inner surface up) on a flat working surface. Ensure to retain the 10mm
bolts to re-install.
· Insert 8x cage nuts into the square holes on the back side of internal
shield. (FIG 1) · Return internal shield back onto the unit and secure with
the 10mm bolts. · Remove the outside air rear spigot (FIG 3) if not using for
an outside air direct connection or remove
the knock out point on rear shield (FIG 4) so the rear shield can be fitted. ·
Place the heat shield onto the unit and secure using the supplied 10mm bolts
into the cage nuts on
the internal shield (FIG 5)
FIG 1.
FIG 2.
FIG 3.
FIG 4.
22
FIG 5.
VisionLINE Wood Stove Warranty
VisionLINE extends the following manufacturer’s warranty for wood hearth
appliances that are purchased from a VisionLINE authorised dealer. VisionLINE
warrants to the original owner of the VisionLINE appliance at the site of
installation, and to any transferee taking ownership of the appliance at the
site of installation within two years following the date of original purchase,
that the VisionLINE appliance will be free from defects in materials and
workmanship at the time of manufacture. After installation, if covered
components manufactured by VisionLINE are found to be defective in materials
or workmanship during the applicable warranty period, VisionLINE will, at its
option, repair or replace the covered components. VisionLINE, at its own
discretion, may fully discharge all of its obligations under this
manufacturer’s warranty by replacing the product itself or refunding the
verified purchase price of the product itself. The maximum amount recoverable
under this warranty is limited to the purchase price of the product. This
warranty is subject to conditions, exclusions and limitations as described
below. Warranty coverage begins on the date of original purchase. In the case
of new home construction, coverage under this manufacturer’s warranty begins
on the date of first occupancy of the dwelling or six months after the sale of
the product by an independent, authorised VisionLINE dealer/ distributor,
whichever occurs earlier. The warranty period for this manufacturer’s warranty
shall commence no later than 12 months following the date of product shipment
from VisionLINE AU, regardless of the installation or occupancy date. The term
“Limited Lifetime” in the table below is defined as: 10 years from the
beginning date of warranty coverage for wood appliances. These time periods
reflect the minimum expected useful lives of the designated components under
normal operating conditions. 15 year structural warranty on the firebox
construction including weldment. 5 year warranty on tertiary air tube, baffle
and bricks. (labour for 3 years) 2 year warranty on fans and electrical
components. (labour for 1 year)
OTHER RIGHTS
The VisionLINE manufacturer’s warranty is in addition to other rights and
remedies that you may have under Australian law. Our goods come with
guarantees that cannot be excluded under the Australian Consumer Law. You are
entitled to a replacement or refund for a major failure and for compensation
for any other reasonably foreseeable loss or damage. You are also entitled to
have the goods repaired or replaced if the goods fail to be of acceptable
quality and the failure does not amount to a major failure. WARRANTY
CONDITIONS AND EXCLUSIONS: The VisionLINE manufacturer’s warranty only covers
VisionLINE appliances that are purchased through a VisionLINE authorized
dealer or distributor. A list of VisionLINE authorised dealers is available on
the VisionLINE branded websites. This warranty is only valid while the
VisionLINE appliance remains at the site of original installation. WARRANTY
EXCLUSIONS: This VisionLINE manufacturer’s warranty does not cover the
following: · Changes in surface finishes as a result of normal use. As a
heating appliance, some changes in colour of interior
and exterior surface finishes may occur. This is not a flaw and is not covered
under warranty. · Damage to printed, plated, or enamelled surfaces caused by
fingerprints, accidents, misuse, scratches, melted
items, or other external sources and residues left on the plated surfaces from
the use of abrasive cleaners or polishes. · Repair or replacement of parts
that are subject to normal wear and tear during the warranty period. These
parts include: paint, gaskets, firebricks, grates and the discolouration of
glass. · Minor expansion, contraction, or movement of certain parts causing
noise. These conditions are normal and complaints related to this noise are
not covered by this warranty.
23
WARRANTY EXCLUSIONS cont. · Damages resulting from: (1) failure to install,
operate, or maintain the appliance in accordance with the
installation instructions, operating instructions, and listing agent
identification label furnished with the appliance;
(2)failuretoinstalltheappliancein accordance with local building codes; (3)
shipping or improper handling; (4) improper operation, abuse, misuse,
continued operation with damaged, corroded or failed components, accident, or
improperly/incorrectly performed repairs; (5) environmental conditions,
inadequate ventilation, negative pressure, or drafting caused by tightly
sealed constructions, insufficient make-up air supply, or handling devices
such as exhaust fans or forced air furnaces or other such causes; (6) use of
fuels other than those specified in the operating instructions; (7)
installation or use of components not supplied with the appliance or any other
components not expressly authorised and approved by VisionLINE (8)
modification of the appliance not expressly authorised and approved by
VisionLINE in writing; and/or (9) interruptions or fluctuations of electrical
power supply to the appliance.
· Non VisionLINE venting components, hearth components or other accessories
used in conjunction with the appliance.
· Any part of a pre-existing fireplace system in which an insert appliance is
installed. · Removal, installation, reinstallation, set up or any other costs
associated with a claim including travel and
shipping charges for parts. · VisionLINE’s obligation under this warranty does
not extend to the appliance’s capability to heat the desired
space. Information is provided to assist the consumer and the dealer in
selecting the proper appliance for the application. Consideration must be
given to appliance location and configuration, environmental conditions,
insulation and air tightness of the structure.
This warranty is void if:
· The appliance has been over-fired or operated in atmospheres contaminated by
chlorine, fluorine, or other damaging chemicals. Over-firing can be identified
by, but not limited to, warped plates or tubes, rust coloured cast iron,
bubbling, cracking and discolouration of steel finishes.
· The appliance is subjected to prolonged periods of dampness or condensation.
· There is any damage to the appliance or other components due to water or
weather damage which is the result
of, but not limited to, improper chimney or venting installation. HOW TO CLAIM
· To make a claim against this warranty, contact your local distributor during
regular business hours. See
addresses below for a dealer nearest you. · Additional service fees may apply
if you are seeking warranty service from a dealer other than the dealer from
whom you originally purchased the product. · Check with your distributor in
advance for any costs to you when arranging a warranty call. Travel and
shipping
charges for parts are not covered by this manufacturers warranty. · VisionLINE
will assess your claim. VisionLINE (AU) or The Fireplace (NZ) may need to
inspect the product as
part of the assessment of your claim. If the product requires inspection,
VisionLINE or The Fireplace will discuss with you the best way for this to
occur. · To make a claim under this manufacturer’s warranty, you must be able
to prove when you purchased the product. The easiest way to do this is through
your original proof of purchase, for example your invoice or receipt. However,
if you do not have your original proof of purchase VisionLINE or Jetmaster may
accept other evidence of the date of purchase.
VisionLINE Australia PO Box 5051 Burnley, 3121
Phone: (03) 9429 5573 Email: info@visionlinefire.com.au
Web: visionlinefire.com.au
The Fireplace 12 Tawari st, Mt Eden, 1024
Phone: (09) 623 6990 Email: sales@thefireplace.co.nz
Web: thefireplace.co.nz
24
References