Schneider Electric™ TPRBCEIP TeSys™ Active Bus Coupler User Manual

MFR4409703

Bus Coupler

DANGER

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

  • Read and understand this document and the documents listed on page 4 before installing, operating, or maintaining your TeSys Active.
  • This equipment must only be installed and serviced by qualified electrical personnel.
  • Turn off all power supplying this equipment before working on or in this equipment, inserting or removing the micro SD card, or making the service port or fieldbus connections.
  • Use only the specified voltage when operating this equipment and any associated products.

Failure to follow these instructions will result in death or serious injury.

WARNING

UNINTENDED EQUIPMENT OPERATION

  • Do not disassemble, repair, or modify this equipment. There are no user serviceable parts.
  • Install and operate this equipment in an enclosure appropriately rated for its intended environment.
  • Always route communication wiring and power wiring separately.

F ailure to follow these instructions can result in death,serious injury, or equipment damage.

WARNING: This product can expose you to chemicals including Antimony oxide (Antimony trioxide), which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov.

Intended Use

The TeSys Active bus coupler is intended to be used as the fieldbus communication interface, and to control all other modules on the island.
The upstream DC power supply used with the TeSys Active bus coupler must be Overvoltage Category III rated or higher.

Features

Features

A. 24 Vdc control power supply connector with spring terminals
B. Terminal/Service port 1 x RJ45
C. Dual port Ethernet switch
D. LED status indicators
E. Slot for micro SD card
F. Name tag
G. QR code
H. Flat cable connection point
I. DIN rail clip

Mounting

Mounting Figure 1

Mounting Figure 2

Cabling

CablingMicro SD Card (FAT32)

Service Port Connections

Service Port Connections

Fieldbus Connection

Fieldbus Connection

Documentation

  • 8536IB1901, System Guide
  • 8536IB1902, Installation Guide
  • 8536IB1903, Operating Guide
  • 8536IB1904, Functional Safety Guide
    Available at www.se.com.

PLEASE NOTE

  • Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel.
  • No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.

Schneider Electric Industries SAS
35, rue Joseph Monier
CS30323
F – 92500 Rueil-Malmaison
www.se.com

Schneider Electric Limited
Stafford Park 5
Telford, TF3 3BL
United Kingdom
www.se.com/uk

Уполномоченный поставщик в РФ:
АО «Шнейдер Электрик»
Адрес: 127018, г. Москва, ул.
Двинцев, д.12, корп.1, тел. +7 (495)777 99 88,
факс: +7 (495)777 99 94, 8-800-200-6446
www.se.com/ru

MFR44097-03 © 2022 Schneider Electric All rights reserved

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Schneider Electric User Manuals

Related Manuals