Koppel RG51A-E Remote Controller Owner’s Manual
- June 10, 2024
- koppel
Table of Contents
REMOTE CONTROLLER
OWNER’S MANUAL
IMPORTANT NOTE:
Thank you for purchasing our air conditioner. Please read this manual
carefully before operating your new air conditioning unit. Make sure to save
this manual for future reference.
Remote Controller Specifications
Model| RG51A/E, RG51A(1)/EU1, RG51A/CE, RG51A10/E, RG51Y5/E
RG51B/E, RG51B(1)/EU1, RG51B/CE, RG51B10/E, RG51Y6/E
---|---
Rated Voltage| 3.0V( Dry batteries R03/LR03×2)
Signal Receiving Range| 8m
Environment| -5°C~60°C(23°F~140°F)
NOTE: For models of RG51Y5/E and RG51Y6/E, If the unit is turned off
under COOL, AUTO or DRY mode with the set temperature less than 24 C, the set
temperature will be automatically set to 24 C when you turn on the unit again.
If the unit is turned off under HEAT mode with the set temperature more than
24 C, the set temperature will be automatically set to 24 C when you turn on
the unit again.
Quick Start Guide
NOT SURE WHAT A FUNCTION DOES?
Refer to the How to Use Basic Functions and How to Use Advanced Functions
sections of this manual for a detailed description of how to use your air
conditioner.
SPECIAL NOTE
- Button designs on your unit may differ slightly from the example shown.
- If the indoor unit does not have a particular function, pressing that function’s button on the remote control will have no effect.
- When there are wide differentces between “Remote controller Manual” and “USER’S MANUAL” on function description, the description of “USER’S MANUAL” shall prevail.
Handling the Remote Controller
Inserting and Replacing Batteries
Your air conditioning unit may come with two batteries(some units). Put the
batteries in the remote control before use.
- Slide the back cover from the remote control downward, exposing the battery compartment.
- Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
- Slide the battery cover back into place.
BATTERY NOTES
For optimum product performance:
- Do not mix old and new batteries, or batteries of different types.
- Do not leave batteries in the remote control if you don’t plan on using the device for more than 2 months.
BATTERY DISPOSAL
Do not dispose of batteries as unsorted municipal waste. Refer to local laws
for proper disposal of batteries.
TIPS FOR USING REMOTE CONTROL
- The remote control must be used within 8 meters of the unit.
- The unit will beep when remote signal is received.
- Curtains, other materials and direct sunlight can interfere with the infrared signal receiver.
- Remove batteries if the remote will not be used more than 2 months.
CAUTIONS FOR USING REMOTE CONTROL
The device could comply with the local national regulations.
- In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
- In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- Changes or modifications not expressly approved by the party responsible for compliance could void user’s authority to operate the equipment.
Buttons and Functions
Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the How to Use Basic Functions section of this manual.
Model: RG51A/E, RG51Y5/E, RG51A(1)/EU1
RG51A10/E(20-28 C)
RG51A/CE(Cooling only models,
AUTO mode and HEAT mode are not available)
Model: RG51B/E, RG51Y6/E,
RG51B(1)/EU1
RG51B10/E(20-28 C)
RG51B/CE(Cooling only models,
AUTO mode and HEAT mode are not available)
Remote Screen Indicators
Information are displayed when the remote controller is power up.
Mode display
AUTO|
---|---
HEAT|
COOL|
FAN|
DRY|
| Displayed when data transmitted.
---|---
| Displayed when remote controller is ON.
ON| Displayed when TIMER ON time is set
OFF| Displayed when TIMER OFF time is set
| Shows set temperature or room temperature, or time under TIMER setting
| Displayed when ECO feature is activated (some unit)
| Indicated all the current settings are locked
| Displayed when Follow Me feature is activated(some units)
| Displayed when SLEEP feature is activated
Fan speed indication
► HIGH | High speed |
---|---|
► MED | Medium speed |
LOW | Low speed |
NO display | Auto fan speed |
Note:
All indicators shown in the figure are for the purpose of clear presentation.
But during the actaul operation, only the relative function signs are shown on
the display window.
How to Use Basic Functions
Basic operation
ATTENTION! Before operation, please ensure the unit is plugged in and
power is available.
COOL Mode
-
Press the MODE button to select COOL mode.
-
Set your desired temperature using the
TEMP ▲ or ▼ TEMP button. -
Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH.
-
Press the ON/OFF button to start the unit.
SETTING TEMPERATURE
The operating temperature range for units is 17-30°C (62-86°F)/20-28 C.
You can increase or decrease the set temperature in 1°C (1°F) increments.
AUTO Mode
In AUTO mode, the unit will automatically select the COOL, FAN, or HEAT
operation based onthe set temperature.
-
Press the MODE button to select AUTO.
-
Set your desired temperature using the TEMP
▲ or TEMP ▼ button. -
Press the ON/OFF button to start the unit.
NOTE: FAN SPEED can’t be set in AUTO mode.
DRY Mode (dehumidifying)
- Press the MODE button to select DRY.
- Set your desired temperature using the TEMP ▲ or TEMP ▼ button.
- Press the ON/OFF button to start the unit.
NOTE: FAN SPEED cannot be changed in DRY mode.
FAN Mode
- Press the MODE button to select FAN mode.
- Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH.
- Press the ON/OFF button to start the unit.
NOTE: You can’t set temperature in FAN mode.
As a result, your remote control’s LCD screen will not display temperature.
HEAT Mode
-
Press the MODE button to select HEAT mode.
-
Set your desired temperature using the TEMP ▲ or ▼ TEMP button.
-
Press FAN button to select the fan speed:
AUTO, LOW, MED or HIGH. -
Press the ON/OFF button to start the unit.
NOTE: As outdoor temperature drops, the performance of your unit’s HEAT function may be affected. In such instances, we recommend using this air conditioner in conjunction with other heating appliances.
Setting the TIMER
TIMER ON/OFF – Set the amount of time after which the unit will automatically
turn on/off.
TIMER ON setting
Press TIMER ON button to initiate the ON time sequence.
Press Temp. up or down button for for multiple times to set the desired time to turn on the unit.
Point remote to unit and wait 1sec, the TIMER ON will be activated.
TIMER OFF setting
Press TIMER OFF button to initiate the OFF time sequence.
Press Temp. up or down button for for multiple times to set the desired time to turn off the unit.
Point remote to unit and wait 1sec, the TIMER OFF will be activated.
TIMER ON & OFF setting(example)
Keep in mind that the time periods you set for both functions refer to hours
after the current time.
Example: If current timer is 1:00PM, to set the timer as above steps, the unit will turn on 2.5h later (3:30PM) and turn off at 6:00PM.
How to Use Advanced Functions
Swing function
Press Swing button
The horizontal louver will swing up and down automatically when pressing Swing button. Press again to make it stop.
Keep pressing this button more than 2 seconds, the vertical louver swing
function is activated. (Model dependent)
Airflow direction
Each time you press the button, it will adjust the louver by 6 degrees . Press
the button until the direction you prefer is reached.
LED DISPLAY
Press this button to turn on and turn off the display on the indoor unit.
Keep pressing this button more than 5 seconds, the indoor unit will display
the actual room temperature. Press more than 5 seconds again will revert back
to display the setting temperature.
ECO function
Press this button under COOL Mode to enter the energy efficient mode.
(For model of RG51A/E, RG51A(1)/EU1, RG51A/CE, RG51A10/E, RG51Y5/E)
Note: This function is only available under COOL mode.
Under cooling mode, press this button, the remote controller will adjust the
temperature automatically to 24º C/75º F, fan speed of Auto to save energy
(only when the set temperature is less than 24º C/75º F). If the set
temperature is above 24º C/75º F, press the ECO button, the fan speed will
change to Auto, the set temperature will remain unchanged.
NOTE:
Pressing the ECO button, or modifying the mode or adjusting the set
temperature to less than 24º C/75 F will stop ECO operation.
Under ECO operation, the set tmeperature should be 24º C/75º F or above, it
may result in insufficient cooling. If you feel uncomfortable, just press the
ECO button again to stop it.
SHORTCUT function
Used to restore the current settings or resume previous settings.
(For model of RG51B/E, RG51B(1)/EU1, RG51B/CE, RG51B10/E, RG51Y6/E)
Push this button when remote controller is on, the system will automatically
revert back to the previous settings including operating mode, setting
temperature, fan speed level and sleep feature(if activated).
If pushing more than 2 seconds, the system will automatically restore the
current operation settings including operating mode, setting temperature, fan
speed level and sleep feature (if activated ).
SLEEP function
The SLEEP function is used to decrease energy use while you sleep (and don t
need the same temperature settings to stay comfortable). This function can
only be activated via remote control. The sleep function is not available in
Fan or Dry mode.Please refer to the OWNER’S MANUAL for more details.
Silence function
Keep pressing Fan button for more than 2 seconds to activate/disable
Silence function(some units).
Due to low frequency operation of compressor, it may result in insufficient
cooling and heating capacity. Press ON/OFF, Mode, Sleep, Turbo or Clean button
while perating will cancel silence function.
FP function
Press this button 2 times during one second under HEAT Mode and setting
temperature of 17º C/62 F or 20º C(for models of RG51A10/E & RG51B10/E).
The unit will operate at high fan speed (while compressor on) with temperature
automatically set to 8º C/46º F.
Note: This function is for heat pump air conditioner only.
Press this button 2 times during one second under HEAT Mode and setting
temperature of 17º C/62º F or 20º C(for models of RG51A10/E and RG51B10/E) to
activate FP function.
Press On/Off, Sleep, Mode, Fan and Temp. button while operating will cancel
this function.
Temperature display
Press together & buttons at the same time for 3 seconds will
alternate the temperature display between the °C & °F (Applicable for models
of RG51A(1)/EU1 and RG51B(1)/EU1 only)
The design and specifications are subject to change without prior notice for
product improvement. Consult with the sales agency or manufacturer for
details.
CR270-RG51A-B(E)
A Tradition of leadership and excellence for over 50 years
Koppel Head Office:
106 Industry Drive, Carmelray
Industrial Park I, Brgy. Canlubang,
Calamba City, Laguna 4028
Tel no:(02) 8823-88-83
Website: www.koppel.ph
*All specifications are subject to change without prior notice for continous product improvement.
POED REV. No.: 01-0419
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>