Juniper Mist AP24 Wireless and WiFi Access Points Installation Guide
- June 10, 2024
- JUNIPer
Table of Contents
- AP24 Hardware Installation
- I/O ports
- AP24 Mounting
- APBR-U Mounting box options
- Mounting to a 9/16 inch or 15/16 inch T-bar
- US single gang, 3.5 or 4 inch round junction box
- US double gang junction box
- US 4 inch square junction box
- EU junction box
- Recessed 15/16 inch T-bar
- Recessed 9/16 inch T-bar or channel rail
- 1.5 inch T-bar
- Threaded rod adapter (1/2″, 5/8″, or M 16)
- Technical Specifications:
- Warranty Information
- Regulatory Compliance Information
- FCC Requirement for Operation in the United States of America
- Industry Canada
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Juniper Mist AP24 Wireless and WiFi Access Points
AP24 Hardware Installation
Overview
The Mist AP24 contains three IEEE 802.11ax radios that deliver 2×2 MIMO with two spatial streams when operating in multi-user (MU) or single-user (SU) mode. The AP24 is capable of operating simultaneously in the 6GHz band, 5GHz band, and 2.4GHz band or two bands and a dedicated tri-band scan radio.
I/O ports
AP24 Mounting
APBR-U Mounting box options
Reset | Reset to the factory default settings |
---|---|
USB | USB2.0 support interface |
Eth0+PoE | 100/1000/2500/5000BASE-T RJ45 interface that supports |
802.3at/802.3bt PoE PD
In a wall mount installation, please use screws that have a 1/4in. (6.3mm)
diameter head with a length at least 2 in. (50.8mm).
APBR-U that is in the AP24 box includes a set screw and an eyehook.
Mounting to a 9/16 inch or 15/16 inch T-bar
Step 1.
Mount APBR-U to the t-bar
Step2.
Rotate APBR-U to lock to the t-bar
Step3.
Slide the AP with shoulder screws on the APBR
US single gang, 3.5 or 4 inch round junction box
Step 1 Mount APBR-U to the box using two screws and the #1 holes. Make
sure Ethernet cable extends thru the bracket .
Step 2 Slide the AP with shoulder screws on the APBR-U until the lock is
engaged
US double gang junction box
Step 1
Mount APBR-U to the box using two screws and the #2 holes. Make sure Ethernet
cable extends thru the bracket.
Step 2
Slide the AP with shoulder screws on the APBR-U until the lock is engaged
US 4 inch square junction box
Step 1 Mount APBR-U to the box using two screws and the #3 holes. Make
sure Ethernet cable extends thru the bracket.
Step 2 Slide the AP with shoulder screws on the APBR-U until the lock is
engaged
EU junction box
Step 1
Mount APBR-U to the box using two screws and the #4 holes. Make sure Ethernet
cable extends thru the bracket.
Step 2
Slide the AP with shoulder screws on the APBR-U until the lock is engaged
Recessed 15/16 inch T-bar
Step 1
Mount the APBR-ADP-RTlS to the t -bar
Step 2
Mount the APBR-U to the APBR-ADP-RTlS. Rotate the APBR-U to lock to the
APBRADP- RTlS
Step 3
Slide the AP with shoulder screws on the APBR-U until the lock is engaged
Recessed 9/16 inch T-bar or channel rail
Step 1
Mount the APBR-ADP-CR9 to the t-bar
Step 2
Mount the APBR-U to the APBR-ADP-CR9. Rotate the APBR-U to lock to the
APBRADP- CR9
Step 3
Slide the AP with shoulder screws on the APBR-U until the lock is engaged
1.5 inch T-bar
Step 1
Mount the APBR-ADP-WS15 to the t-ba r
Step 2
Mount the APBR-U to the APBR-ADP-WS15. Rotate the APBR-U to lock to the APBR-
ADP-WS15
Step 3
Slide the AP with shoulder screws on the APBR-U until the lock is engaged
Threaded rod adapter (1/2″, 5/8″, or M 16)
Step 1
Install the APBR-ADP-T12 to the APBR-U. Rotate to lock.
Step 2
Secure the APBR-ADP-T12 to the APBR-U with the provided screw
Step 3
Install the bracket assembly to the 1/2″ threaded rod and secure with the
provided lock washer and nut.
Step 4
Slide the AP with shoulder screws on the APBR-U until the lock is engaged The
same instructions work for the APBR-ADP-T58 or APBR-ADP-M16
The threaded rod adapter attaches to a rod that is either 1/2″-13, 5/8”-11, or M16-2.
Technical Specifications:
Feature | Description |
---|---|
Power options | 802.3at/802.3bt PoE |
Dimensions | 185mm x 185mm x 39mm (7.28in x 7.28in x 1.54in) |
Weight | AP24: 0.75 kg (1.65 lbs) |
Operating temperature | AP24: 0° to 40° C |
Operating humidity | 10% to 90% maximum relative humidity, non-condensing |
Operating altitude | 3,048m (10,000 ft) |
Electromagnetic emissions | FCC Part 15 Class B |
I/O | 1 – 100/1000/2500BASE-T auto-sensing RJ-45 with PoE USB2.0 |
RF | 2.4GHz or 6GHz – 2×2:2SS 802.11ax MU-MIMO & SU-MIMO |
5GHz – 2×2:2SS 802.11ax MU-MIMO & SU-MIMO
2GHz 2×2:2SS 802.11ax MU-MIMO & SU-MIMO or 1×1: 1SS
802.11ax 2.4GHz/5GHz/6GHz scan
2.4GHz BLE/Zigbee/Thread with Omni Antenna
Maximum PHY rate| Total maximum PHY rate – 4200 Mbps 6GHz – 2400 Mbps
5GHz – 1200 Mbps
2.4GHz – 600 Mbps
Indicators| Multi-color status LED
Safety standards| UL 62368-1
CAN/CSA-C22.2 No. 62368-1-14
UL 2043
ICES-003:2020 Issue 7, Class B (Canada)
Suitable for use in environmental air space in accordance with Section 300-22(C) of the National Electrical Code, and Sections 2-128, 12-010(3), and 12-100 of the Canadian Electrical Code, Part 1, CSA C22.1
Warranty Information
The AP24 family of Access Points comes with a limited lifetime warranty.
Ordering Information:
Access Points
AP24-US | 802.11ax 6E 2+2+2 – Internal Antenna for the US Regulatory domain |
---|---|
AP24-WW | 802.11ax 6E 2+2+2 – Internal Antenna for the WW Regulatory domain |
Mounting brackets
APBR-U| Universal AP Bracket for T-Rail and Drywall mounting for Indoor Access
Points
---|---
APBR-ADP-T58| Adapter for 5/8-inch threaded rod bracket
APBR-ADP-M16| Adapter for 16mm threaded rod bracket
APBR-ADP-T12| Adapter for 1/2-inch threaded rod bracket
APBR-ADP-CR9| Adapter for channel rail and recessed 9/16” t-rail
APBR-ADP-RT15| Adapter for recessed 15/16″ t-rail
APBR-ADP-WS15| Adapter for recessed 1.5″ t-rail
Power supply options
802.3 at or 802.3bt PoE power
Regulatory Compliance Information
This product and all interconnected equipment must be installed indoors within the same building, including the associated LAN connections as defined by the 802.3at Standard.
Operations in the 5.15GHz – 5.35GHz band are restricted to indoor usage only.
If you need further assistance with purchasing the power source, please contact Juniper Networks, Inc.
FCC Requirement for Operation in the United States of America
FCC Part 15.247, 15.407, 15.107, and 15.109
FCC Guideline for Human Exposure
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance between the radiator & your body; AP24 – 20cm
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
- Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
- This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
- For operation within 5.15 ~ 5.25GHz / 5.47 ~5.725GHz / 5.925 ~ 7.125GHz frequency range, it is restricted to indoor environment.
- The 5.925 ~ 7.125GHz operation of this device is prohibited on oil platforms, cars, trains, boats, and aircraft, except that operation of this device is permitted in large aircraft while flying above 10,000 feet.
- Operation of transmitters in the 5.925-7.125 GHz band is prohibited for control of or Communications with unmanned aircraft systems.
Industry Canada
This device contains license-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s license-exempt
RSS(s).
Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Caution
(i) The device for operation in the band 5150-5250 MHz is only for indoor
use to reduce the potential for harmful interference to co-channel mobile
satellite systems;
(ii) The maximum antenna gain permitted for devices in the bands
5250-5350 MHz and 5470-5725 MHz shall be such that the equipment still
complies with the e.i.r.p. limit;
(iii) The maximum antenna gain permitted for devices in the band
5725-5850 MHz shall be such that the equipment still complies with the
e.i.r.p. limits specified for pointto-point and non-point-to-point operation
as appropriate; and
(iv) Operation shall be limited to indoor use only.
(v) Operation on oil platforms, automobiles, trains, maritime vessels and
aircraft shall be prohibited except for on large aircraft flying above 3,048 m
(10,000 ft).
Radiation Exposure Statement
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm (AP24) between the radiator & your body