PCE Instruments PCE-PMI 1BT Wood Moisture Meter
Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non- observance of the manual are excluded from our liability and not covered by our warranty.
- The device must only be used as described in this instruction If used otherwise, this can cause dangerous situations for the user and damage to the meter.
- The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
- Do not expose the device to shocks or strong
- The case should only be opened by qualified PCE Instruments
- Never use the instrument when your hands are
- You must not make any technical changes to the
- The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or
- The device must only be used with accessories from PCE Instruments or
- Before each use, inspect the case for visible damage. If any damage is visible, do not use the
- Do not use the instrument in explosive
- The measurement range as stated in the specifications must not be exceeded under any
- Non-observance of the safety notes can cause damage to the device and injuries to the user.
We do not assume liability for printing errors or any other mistakes in this manual.
We expressly point to our general guarantee terms which can be found in our general terms of business.
Specifications
Measurement range | 0.0 … 100.0 % |
---|---|
Resolution | 0.1 % |
Measurement rate | 2 Hz |
Measuring depth | 20 … 40 mm / 0.78…. 1.57″ |
Interface | Bluetooth 4.0 |
Measuring principle | capacitive (electrical resistance) |
Sensor type | metal spheroid |
Power supply | 2 x 1.5 V AAA batteries |
Operating conditions | 0 … 50 °C / 32 … 122 °F <90 % RH, non-condensing |
Dimensions | 160 x 33 x 20 mm / 6.3 x 1.3 x 0.7″ |
Weight | 93 g / 3.2 oz |
Delivery scope
1 x moisture meter PCE-PMI 1BT
2 x 1.5 V AAA batteries
1 x user manual
1 x hand strap
Device description
No. | Description |
---|---|
1 | Measuring ball |
2 | Status display |
3 | On and off switch |
4 | Battery compartment cover |
5 | Closure of the battery compartment cover |
6 | Loop holder |
Establishing a Bluetooth connectiona Bluetooth connection
To establish a Bluetooth connection, first switch on the meter. Then download the app “PCE SmartMeasure Environmental” from the respective store.
To establish a connection, first switch on the meter.
Enable Bluetooth and the location function in your mobile device.
Next, open the app and apply the “Connect” button.
Now select “Search devices” in the lower area of the display and connect to
the PCE-PMI 1BT by selecting the device.
After the connection, the meter can be operated via the app.
Note: Do not establish a connection via the system setting but only via
the app.
Making a measurement
Once a connection has been established, a measurement can be taken. The meter should be held as shown in the illustration. For a measurement, place the measuring ball on the surface to be checked. You can read the measured value directly from your mobile device.
Note: On an even surface, the distance between the nearest wall and the measuring ball must not be less than 10 cm. During the measurement, the measuring device must be positioned perpendicular to the sample. When making a measurement, your hand should not come close to the metal ball as the water content in the human body will falsify the measurement.
Replacing batteries
To replace the batteries, first switch off the meter. Then open the battery compartment on the back and insert 2 x 1.5 V AAA batteries. Make sure that the polarity is correct
Status display
Status display (LED) | Meaning |
---|---|
Green (flashing) | Bluetooth connection established |
Yellow (flashing) | Bluetooth connection not established |
Yellow (constant) | Battery voltage too low |
Automatic power off
When the meter is not connected to a mobile handheld device, it will switch off within 3 minutes.
Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste.
They must be given to collection points designed for that purpose. In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
User manuals in various languages
PCE Instruments contact information
United States of America
PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter / Palm Beach
33458 FL
USA
Tel: +1 561-320-9162
Fax: +1 561-320-9176
info@pce-americas.com
www.pee-instruments.com/us
References
- France.fr : Explore France and its wonders - Explore France
- iberica.es
- Make an offer on the domain instruments.co.uk - Domains.co.uk
- Computer Instruments | Home
- Discover Italy: Official Tourism Website - Italia.it
- pce-instruments.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>