INSTALLATION INSTRUCTIONS
Commercial Stacked Dryer Gas (120 V, 60 Hz) or Electric (120/240 V, 60 Hz)
INSTRUCTIONS D’INSTALLATION
Sécheuse à usage commercial superposée
à gaz (120 V, 60 Hz) ou électrique
(120/240 V, 60 Hz)
www.maytagcommerciallaundry.com
W11595587A W11599649A-SP
DRYER SAFETY
It is recommended that the owner post, in a prominent location, instructions
for the customer’s use in the event the customer smells gas. This information
should be obtained from your gas supplier.
Post the following warning in a prominent location. 2
DRYER SAFETY
WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly
could result in serious injury, death or property damage. Do not store or
use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance. WHAT TO DO IF YOU SMELL GAS:
· Do not try to light any appliance. · Do not touch any electrical switch; do
not use any phone in your building. · Clear the room, building, or area of all
occupants. · Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s
instructions.
· If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service
agency, or the gas supplier.
In the State of Massachusetts, the following installation instructions apply:
Installations and repairs must be performed by a qualified or licensed
contractor, plumber, or gas fitter qualified or licensed by
the State of Massachusetts. Acceptable Shut-off Devices: Gas Cocks and Ball
Valves installed for use shall be listed. A flexible gas connector, when used,
must not exceed 4 feet (121.9 cm).
IMPORTANT: The gas installation must conform with local codes, or in the
absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54,
or the Natural Gas and Propane Installation Code, CSA B149.1. The dryer must
be electrically grounded in accordance with local codes, or in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian
Electrical Code, Part 1, CSA C22.1.
3
DRYER SAFETY
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when
using the dryer, follow basic precautions, including the following:
Read all instructions before using the dryer.
Clean dryer lint screen before or after each load.
This dryer is intended only for drying clothes and textiles that have been
washed in water. Do not use for any other purpose.
WARNING: If you smell gas, do not use the dryer or any electrical equipment
nearby. Warn other people to clear the area. Contact the dryer owner
immediately.
Do not place items exposed to cooking oils in your dryer. Items contaminated
with cooking oils may contribute to a chemical reaction that could cause a
load to catch fire
To reduce the risk of fire due to contaminated loads, the final part of a
tumble dryer cycle occurs without heat (cool down period). Avoid stopping a
tumble dryer before the end of the drying cycle unless all items are quickly
removed and spread out so that the heat is dissipated.
Do not dry articles that have been previously cleaned in, washed in, soaked
in, or spotted with gasoline, dry-cleaning solvents, other flammable, or
explosive substances as they give off vapors that could ignite or explode.
Do not dry unwashed items in the dryer. Do not allow children to play on or in
the dryer. Close
supervision of children is necessary when the dryer is used near children.
Before the dryer is removed from service or discarded, remove the doors to the
dryer compartment. Do not reach into the dryer if the drum is moving. Do not
open door while dryer is in operation. It will stop. Do not install or store
the dryer where it will be exposed to water and/or the weather. Do not tamper
with controls.
Do not use this dryer without the lint screen in place. Do not repair or
replace any part of the dryer or attempt any
servicing unless specifically recommended in this Installation Instructions or
in published user-repair instructions that you understand and have the skills
to carry out. Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric softener or product. Do
not use heat to dry articles containing foam rubber or similarly textured
rubber-like materials. The final part of a tumble dryer cycle occurs without
heat (cool-down cycle) to ensure that the articles are left at a temperature
that ensures that the items will not be damaged. WARNING: Never stop a tumble
dryer before the end of the drying cycle unless all items are quickly removed
and spread out so that the heat is dissipated. (Avoids risk of spontaneous
combustion). Keep area around the exhaust opening and adjacent surrounding
areas free from the accumulation of lint, dust, and dirt. The interior of the
dryer and dryer exhaust vent should be cleaned periodically by qualified
service personnel. See “Electrical Requirements” section for grounding
instructions. WARNING: Do not install a booster fan in the exhaust duct. NOTE:
The booster fan warning does not apply to clothes dryers intended to be
installed in a multiple clothes dryer system, with an engineered exhaust duct
system that is installed per the clothes dryer manufacturer’s guidelines.
SAVE THESE INSTRUCTIONS
4
Tools Needed:
8″ (200 mm) or 10″ (250 mm)
Pipe wrench
TOOLS & PARTS
8″ (200 mm) or 10″ (250 mm) Adjustable wrench
that opens to 1″ (25 mm)
Flat-blade screwdriver
Phillips screwdriver
Torx® T-20® security screwdriver or bit
1″ (25 mm) Hex-head socket wrench
5/16″ (8 mm) Socket wrench
Pliers (that open to 19/16″ [39 mm])
Level
Utility knife
1/4″ (6 mm) Nut driver
27″ (686 mm) Wood block
Caulk gun and caulk (for installing new exhaust vent)
Vent clamps
Pipe-joint compound suitable for gas type
Flashlight (optional)
Parts Supplied:
1″ (25 mm) Open-end wrenches
Ruler or measuring tape
Putty knife
Security cotter pins (2) (Located in Bag inside the drum)
Foot Boots (4) (Located in Bag inside the drum)
Leveling Legs (4) (Already Installed on your Dryer)
®TORX and T20 are registered trademarks of Acument Intellectual Properties,
LLC.
5
DIMENSIONS/CLEARANCES
Dimensions Front View
Side View
Back View
Minimum Clearances Front View, Recessed Opening
6
12″ (300 mm)
Side View, Recessed In Closet
Closet
0″ (0 mm)
21/4″ (57 mm)
Closet Door Minimum Acceptable Vent Sizes
3″ (76 mm) 76mm)
48 inches2 (310 cm2)
310 cm2)
1″ (25 mm) Closet door to front of dryer
3″/33″ ” (76 mm)
24 inches2 (155 cm2)
LOCATION REQUIREMENTS
WARNING
Explosion Hazard Keep flammable materials and vapors, such as gasoline, away
from dryer. Do not install in a garage. Failure to do so can result in death,
explosion, or fire.
Your dryer can be installed in a basement, laundry room, or recessed area.
This dryer is not intended for installation in a mobile home or recreational
vehicle. Companion appliance location requirements should also be considered.
IMPORTANT: Do not install or store the dryer where it will be exposed
to water and/or the weather. Proper installation is your responsibility. You
will need: A grounded electrical outlet located within 6 ft. (1.8 m) of where
the power cord is attached to the back of the dryer. See “Electrical
Requirements.” A level floor with a maximum slope of 1″ (25 mm) under entire
dryer. Installing the dryer on soft floor surfaces, such as carpets or
surfaces with foam backing, is not recommended. Dryer installation clearances
The location must be large enough to allow the dryer door to be fully opened.
Additional spacing should be considered for ease of installation and
servicing. The door opens more than 180°. Additional clearances might be
required for wall, door, and floor moldings. Additional spacing of 1″ (25 mm)
on all sides of the dryer is recommended to reduce noise transfer. The back of
the dryer shall be installed against a wall. Refer to the minimum installation
dimensions/clearances in the diagrams.
When installing a gas dryer: IMPORTANT: Observe all governing codes and
ordinances. Check code requirements: Some codes limit or do not
permit installation of clothes dryers in garages, closets, or sleeping
quarters. Contact your local building inspector. Make sure that lower edges of
the cabinet, plus the back and bottom sides of the dryer, are free of
obstructions to permit adequate clearance of air openings for combustion air.
See “Recessed Area Installation Instructions” below for minimum spacing
requirements. Recessed Area Installation Instructions This dryer may be
installed in a recessed area. For recessed area installations, minimum
clearances can be found on the warning label on the rear of the dryer or in
“Dimensions/Clearances.” The installation spacing is in inches and is the
minimum allowable. Additional spacing should be considered for ease of
installation, servicing, and compliance with local codes and ordinances. The
dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same closet as the
dryer.
7
GAS DRYER ELECTRICAL REQUIREMENTS
Gas Dryer Grounding
IMPORTANT: The dryer must be electrically grounded in accordance with local
codes and ordinances or, in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, latest edition, or Canadian Electrical Code,
CSA C22.1. If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that the ground
path is adequate. A copy of the above code standards can be obtained from:
National Fire Protection Association One Batterymarch Park, Quincy, MA 02269
CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575 Do
not ground to a gas pipe. Do not have a fuse in the neutral or ground circuit.
A 120 V, 60 Hz, AC only, 15or 20 A, fused electrical circuit is required. A
time-delay fuse or circuit breaker is also recommended. It is recommended that
a separate circuit serving only this dryer be provided. If codes permit and a
separate ground wire is used, it is recommended that a qualified electrician
determine that the ground path is adequate. Check with a qualified electrician
if you are not sure the dryer is properly grounded.
8
Gas Supply
WARNING
Explosion Hazard Use a new CSA International approved gas supply line. Install
a shut-off valve. Securely tighten all gas connections. If connected to
propane, have a qualified person make sure gas pressure does not exceed 13″
(33 cm) water column. Examples of a qualified person include: licensed heating
personnel, authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
IMPORTANT: Observe all governing codes and ordinances. This installation must
conform with all local codes and ordinances. In the absence of local codes,
installation must conform with American National Standard, National Fuel Gas
Code ANSI Z223.1/NFPA 54 or CAN/CSA B149. A copy of the above code standards
can be obtained from:
National Fire Protection Association One Batterymarch Park, Quincy, MA 02269
CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575
The design of this dryer has been certified by CSA International for use at
altitudes up to 10,000 feet (3048 m) above sea level at the B.T.U. rating
indicated on the model/serial plate. Burner input adjustments are not required
when the dryer is operated up to this elevation. When installed above 10,000
feet (3048 m), a four percent (4%) reduction of the burner B.T.U. rating shown
on the model/serial plate is required for each 1,000 foot (305 m) increase in
elevation. For assistance when converting to other gas types and/or installing
above 10,000 feet (3048 m) elevation, contact your local service company.
GAS REQUIREMENTS
9
ELECTRIC DRYER ELECTRICAL REQUIREMENTS (U.S.A. ONLY)
It is your responsibility: To contact a qualified electrical installer. To be
sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and
all local codes and ordinances. The National Electrical Code requires a 4-wire
power supply connection for homes built after 1996, dryer circuits involved in
remodeling after 1996, and all mobile home installations. A copy of the above
code standards can be obtained from: National Fire Protection Association, One
Batterymarch Park, Quincy, MA 02269. To supply the required 3 or 4 wire,
single phase, 120/240 V, 60 Hz., AC only electrical supply (or 3 or 4 wire,
120/208 V electrical supply, if specified on the serial/rating plate) on a
separate 30 A circuit, fused on both sides of the line. A time delay fuse or
circuit breaker is recommended. Connect to an individual branch circuit. Do
not have a fuse in the neutral or grounding circuit. Do not use an extension
cord. If codes permit and a separate ground wire is used, it is recommended
that a qualified electrician determine that the ground path is adequate.
Electrical Connection To properly install your dryer, you must determine the
type of electrical connection you will be using and follow the instructions
provided for it here. This dryer is manufactured ready to install with a
3-wire electrical supply connection. The neutral ground conductor is
permanently connected to the neutral conductor (white wire) within the dryer.
If the dryer is installed with a 4-wire electrical supply connection, the
neutral ground conductor must be removed from the external ground connector
(green screw), and secured under the neutral terminal (center or white wire)
of the terminal block. When the neutral ground conductor is secured under the
neutral terminal (center or white wire) of the terminal block, the dryer
cabinet is isolated from the neutral conductor. If local codes do not permit
the connection of a neutral ground wire to the neutral wire, see “Optional
3-wire connection” section. A 4-wire power supply connection must be used when
the appliance is installed in a location where grounding through the neutral
conductor is prohibited. Grounding through the neutral is prohibited for (1)
new branch-circuit installations and (2) areas where local codes prohibit
grounding through the neutral conductor.
Electric Dryer Grounding
10
ELECTRIC DRYER ELECTRICAL REQUIREMENTS (U.S.A. ONLY)
Electric Dryer Power Supply Cord
Direct Wire
Fire Hazard
Use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal.
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
If using a power supply cord: Use a UL listed power supply cord kit marked for
use with clothes dryers. The kit should contain:
A UL listed 30 A power supply cord, rated 120/240 V minimum. The cord should
be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that
connect to the dryer must end in ring terminals or “U” shaped spade terminals
with upturned ends.
A UL listed strain relief.
If your outlet looks like this: Then choose a 4-wire power supply cord with ring or
spade terminals and UL listed strain relief. The 4-wire
power supply cord, at least 4 ft. (1.22 m) long,
must have four 10-gauge copper wires and match
a 4-wire receptacle of NEMA Type 14-30R. The
4-wire receptacle
(14-30R)
ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.
If your outlet looks like this:
Then choose a 3-wire power supply cord with ring or spade terminals and UL
listed strain relief. The 3-wire power supply cord, at least 4 ft. (1.22 m)
long, must have three 10-gauge copper wires and match a 3-wire receptacle of
NEMA Type 10-30R. 3-wire receptacle (10-30R)
If connecting by direct wire: Direct wire cable must match power supply
(4-wire or 3-wire) and be: Flexible armored cable or nonmetallic sheathed
copper cable
(with ground wire), covered with flexible metallic conduit. All current-
carrying wires must be insulated. 10-gauge solid copper wire (do not use
aluminum). At least 5 ft. (1.52 m) long.
11
ELECTRIC DRYER ELECTRICAL REQUIREMENTS (CANADA ONLY)
Direct Wire
If connecting by direct wire: Direct wire cable must match power supply
(4-wire or 3-wire) and be: Cable must be rated to 60 A minimum. Flexible
armored cable or nonmetallic sheathed copper cable
(with ground wire), covered with flexible metallic conduit. All current-
carrying wires must be insulated. 6-gauge minimum solid copper wire (do not
use aluminum). At least 5 ft. (1.52 m) long.
12
DRYER VENTING REQUIREMENTS
Elbows: 45° elbows provide better airflow than 90° elbows.
Good
Better
WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling,
attic, crawlspace, or a concealed space of a building. Only rigid or flexible
metal vent shall be used for exhausting.
Clamps: Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws or other fastening
devices that extend into interior of duct and catch lint. Do not use duct
tape.
4″ (102 mm)
4″ (102 mm) Heavy, metal exhaust vent
Only a 4″ (102 mm) heavy, metal exhaust vent and clamps may be used.
Do not use plastic or metal foil vent. Rigid metal vent: Recommended for best
drying performance and to avoid
crushing and kinking. Flexible metal vent: (Acceptable only if accessible to
clean) Must be fully extended and supported in final dryer location. Remove
excess to avoid sagging and kinking that may result
in reduced airflow and poor performance. Do not install in enclosed walls,
ceilings, or floors. The total length should not exceed 73 4 ft. (2.4 m).
NOTE: If using an existing vent system, clean lint from entire length of the
system and make sure exhaust hood is not plugged with lint. Replace plastic or
metal foil vents with rigid metal or flexible metal vents. Review “Vent System
Chart” and if necessary, modify existing vent system to achieve best drying
performance.
13
DRYER VENTING REQUIREMENTS
Vent Hoods 4″ (102 mm) Diameter Exhaust Hoods
Exhaust hood must be at least 12″ (305 mm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks, bushes, or snow).
Box hood
Louvered hood
Angled hood
12″ min. (305 mm)
Vent System Length
Maximum Vent Length/Vent Connection Maximum length of vent system depends upon the type of vent used, number of elbows, and type of exhaust hood.
Vent System Chart (Rigid Metal Vent)
No. of 90° Turns
Box and Louvered Hood
Angled Hood
0
130 ft. (39.6 m) 129 ft. (39.3 m)
1
125 ft. (38.1 m) 119 ft. (36.3 m)
2
115 ft. (35.1 m) 109 ft. (33.2 m)
3
106 ft. (32.3 m) 100 ft. (30.5 m)
4
98 ft. (29.9 m)
92 ft. (28 m)
For vent systems not covered by the vent specification chart, see your parts distributor.
Provision must be made for enough air for combustion and ventilation. (Check governing codes and ordinances.) See “Recessed Area Installation Instructions” in the “Location Requirements” sections.
A 4″ (102 mm) outlet hood is preferred. However, a 21 2″ (64 mm) outlet exhaust hood may be used. A 21 2″ (64 mm) outlet creates greater back pressure than other hood types. For permanent installation, a stationary vent system is required.
Connect Vent 1. If connecting to existing vent, make sure the vent is clean.
Using a in dryer.
4″
(102
mm)
clamp,
connect
vent
to
exhausVt eonuttlceot llar
3. Tighten hose clamp with Phillips screwdriver. 4. Make sure the vent is
secured to exhaust hood
with a 4″ (102 mm) clamp. 5. Move dryer into final position. Do not crush or
kink vent.
Make sure dryer is level.
NOTE: Do not remove vent collar. 14
If an Exhaust Hood Cannot be Used The outside end of main vent should have a sweep elbow directed downward.
12″ min. (305 mm)*
24″ min. (610 mm)
*Minimum clearance above any accumulation of snow, ice, or debris such as leaves
If main vent travels vertically through the roof, rather than through wall,
install a 180° sweep elbow on end of vent at least 2 ft. (610 mm) above
surface of roof. The opening in wall or roof shall have a diameter 1/2″ (13
mm) larger than vent diameter. Vent should be centered in opening. Do not
install screening over end of vent for best performance.
DRYER VENTING REQUIREMENTS
Multiple Dryer Venting A main vent can be used for venting a group of dryers.
The main vent should be sized to remove 5663 l/min. (200 CFM) of air per
dryer. Large-capacity lint screens of proper design may be used in main vent
if checked and cleaned frequently. The room where the dryers are located
should have make-up air equal to or greater than CFM of all the dryers in the
room. Back-draft Damper Kit, Part No. 3391910, is available from your
distributor and should be installed in the vent of each dryer to keep
exhausted air from returning into dryers and to keep exhaust in balance within
main vent. Unobstructed return air openings are required. Each vent should
enter the main vent at an angle pointing in the direction of the airflow.
Vents entering from the opposite side should be staggered to reduce the
exhausted air from interfering with the other vents.
AAirirflflooww
30° max.
The maximum angle of each vent entering the main vent should be no more than 30°. Keep air openings free of dry cleaning fluid fumes. Fumes create acids which, when drawn through the dryer heating units, can damage dryers and items being dried. A clean-out cover should be located on the main vent for periodic cleaning of the vent system.
15
INSTALLING LEVELING LEGS
1. Prepare dryer for leveling legs (Feet have already been installed on this
unit). NOTE: Slide dryer onto cardboard or hardboard before moving to avoid
damaging floor covering. Using two or more people, move dryer to desired
installation location. Take tape off front corners of dryer. Open dryer and
remove the literature and parts packages. Wipe drum interior with damp cloth
to remove any dust. Take two cardboard corners from the dryer carton and place
them on the floor in back of the dryer. Firmly grasp body of the dryer and
gently lay it on its back on the cardboard corners.
2. Screw in leveling legs
Examine leveling legs and find diamond
marking. Screw legs into leg holes by hand. Use an adjustable wrench or 25 mm (1″) hex-head socket wrench to
DDiiaammoonndd finish marking
turning legs until diamond marking
is no longer visible. Then fit a covered foot boot over each leg foot.
Foot
To protect the floor, use a large piece of cardboard from the dryer carton. Stand dryer up on the cardboard. Slide the dryer until it is close to its final location. Leave enough room for electrical connection and to connect the exhaust vent.
16
Leveling your dryer properly reduces excess noise and vibration.
LEVELING
2. Grip dryer from top and rock back and forth, making sure all four feet are
firmly on floor. Repeat, rocking dryer from side to side. If dryer rocks,
adjust leveling feet.
1. Remove cardboard from beneath dryer. Place a level on top edges of dryer, checking each side and front. If not level, tip dryer and adjust legs up or down as shown in Steps 3 and 4, repeating as necessary.
Not Level
LEVEL
Not Level
GAS SUPPLY CONNECTION
Make Gas Connection
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make sure gas pressure does
not exceed 13″ (33 cm) water column.
Examples of a qualified person include: licensed heating personnel, authorized
gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
1. Remove red cap from gas pipe on back of dryer.
3. If dryer is not level, turn the leveling feet counterclockwise to lower
the dryer or clockwise to raise the dryer. Recheck levelness of dryer and that
all four feet are firmly in contact with the floor. Repeat as needed.
HELPFUL TIP: You may want to prop up front of dryer about 4″ (102 mm) with a
wood block or similar object that will support weight of dryer.
2. Connect gas supply to dryer. Use a pipe thread compound approved for the
type of gas supplied. If flexible metal tubing is used, be certain there are
no kinks. If necessary for service, open the toe panel. Use a putty knife to
press on the toe panel locks located at the upper corners of the toe panel.
Pull downward on the toe panel to open. Toe panel is hinged at the bottom.
3. Open the shut-off valve in the gas supply line and make sure the dryer has
its own gas supply opened.
4. Test all connections by brushing on an approved noncorrosive leak-
detection solution. Bubbles will show a leak. Correct any leaks found.
17
GAS SUPPLY CONNECTION
Type of Gas This dryer is equipped for use with natural gas. It is certified
by UL for use with propane gas with appropriate conversion. No attempt shall
be made to convert dryer from gas specified on serial/rating plate for use
with a different gas without consulting the serving gas supplier. Conversion
must be done by a qualified service technician. Gas conversion kit part
numbers are listed on gas valve burner base.
Gas Supply Line
Recommended Method Provide a gas supply line of 1 2″ (13 mm) rigid (IPS) pipe
to dryer location. Pipe joint compounds that resist action of LP gas must be
used. Do not use TEFLON® tape. With LP gas, piping or tubing size can be 1 2″
(13 mm) minimum. Usually, LP gas suppliers determine size and materials used
in the system.
Flexible Metal Appliance Connector It is recommended that a new flexible stainless steel gas line, design-certified by CSA International, be used for connecting the dryer to the gas supply line. (The gas pipe which extends through the lower rear of the dryer is provided with 3 8″ male pipe thread.)
Gas Supply Pressure Testing A 1/8″ NPT minimum plugged tapping, accessible for
gauge testing, must be installed immediately downstream of the installed shut-
off valve to the dryer (as shown above). The dryer must be disconnected from
the gas supply piping system during any pressure testing of the system at test
pressures in excess of 1/2″ psig (352 kg/m2).
Alternate Method The gas supply may also be connected using 3 8″ (10 mm)
approved copper or aluminum tubing. If the total length of the supply line is
more than 20 ft. (6.1 m), larger tubing will be required.
If using natural gas, do not use copper tubing. Pipe joint compounds that
resist action of type of gas supplied must be used.
Shut-off valve required The supply line must be equipped with a manual shut-
off valve installed within 6 ft. (1.8 m) of dryer in accordance with National
Fuel Gas Code, ANSI Z223.1. This valve should be located in same room as
dryer. It should be in a location that allows ease of opening and closing. Do
not block access to shut-off valve. In Canada, an individual manual shut-off
valve must be installed in accordance with the B149 installation codes CAN/CGA
B149.1 and CAN/CGA B149.2.
NOTE: Do not kink or damage the flexible stainless steel gas line when moving
the dryer.
Rigid Pipe Connection The rigid pipe connection requires a combination of pipe
fittings to obtain an in-line connection to the dryer.
®TEFLON is a registered trademark of Chemours.
18
ELECTRIC DRYER ELECTRICAL CONNECTIONS (FOR U.S.A. ONLY)
Power Supply Cord Connection
WARNING
Remove Terminal Block Cover
Fire Hazard Use a new UL listed 30 amp power supply cord. Use a UL listed
strain relief. Disconnect power before making electrical connections. Connect
neutral wire (white or center wire) to center terminal. Ground wire (green or
bare wire) must be connected to green ground connector. Connect remaining 2
supply wires to remaining 2 terminals. Securely tighten all electrical
connections. Failure to do so can result in death, fire, or electrical shock.
Connection Options Power Cord 4-wire receptacle (NEMA Type 14-30R) Go to
“Connecting 4-Wire Connection: Power Supply Cord” section.
C
CB
D
B
A
E
AD
E
Before you start, disconnect power. Remove hold-down screw (D) and terminal block cover (A).
A. Terminal block cover B. External ground conductor screw C. Center terminal block screw D. Hold-down screw E. Neutral ground wire
Power Supply Cord Strain Relief
1. Insert strain relief. Remove the screws from a 3/4″ (19 mm) UL Listed
strain relief. Put the tabs of the two clamp sections (C) into the hole below
the terminal block opening (B) so that one tab is pointing up (A) and the
other is pointing down (D), and hold in place. Tighten strain relief screws
just enough to hold the two clamp sections (C) together.
3-wire receptacle (NEMA Type 10-30R) Go to “Connecting 3-Wire Connection: Power Supply Cord” section. NOTE: If local codes do not permit connection of a cabinetground conductor to neutral wire, go to “Connecting 3-Wire Connection: Optional” section. This connection may be used with either a power supply cord or a direct wire connection.
A
B C D
19
ELECTRIC DRYER ELECTRICAL CONNECTIONS
Power Supply Cord Connection (cont.) 2. Insert power cord into strain relief.
Put power supply cord through the strain relief. Be sure that the wire
insulation on the power supply cord is inside the strain relief. The strain
relief should have a tight fit with the dryer cabinet and be in a horizontal
position. Do not further tighten strain relief screws at this point.
Connecting 4-Wire Connection: Power Supply Cord IMPORTANT: A 4-wire connection is required where local codes do not permit the use of 3-wire connections. Standard Power Supply Cord Connectors
Connecting Power Cord Ground Wire 3. Connect ground wire (green or bare) (E)
with external ground
connector screw (C). Tighten screw.
Flanged spade connector
Ring Connector
Connecting Ground and Neutral Wires
1. Remove center terminal block screw (A) and neutral ground
E
wire (B) by removing the external ground connector screw (C).
C
Connecting Remaining Wires
B
A
4. Connect remaining wires with outer terminal block screws (F).
Tighten screws. Finally, re-install terminal block cover and
tighten hold-down screw. Go to “Complete Installation” section.
C
2. Connect neutral ground (B) and neutral wire (white or center)
(D) to center terminal block. Tighten screw.
F
F
D
B
Connecting 3-Wire Connection: Power Supply Cord Standard Power Supply Cord Connectors
Connecting Neutral Wire 1. Loosen or remove center terminal block screw (A).
Flanged spade connector
Ring Connector
A
20
ELECTRIC DRYER ELECTRICAL CONNECTIONS
Connecting 3-Wire Connection: Power Supply Cord (cont.)
2. Connect white neutral wire (white or center) (D) to center terminal block. Tighten screw.
3. Connect remaining wires with outer terminal block screws (F). Tighten screws. Finally, re-install terminal block cover and tighten hold-down screw. Go to “Complete Installation” section.
D
F F
ELECTRIC DRYER ELECTRICAL CONNECTIONS (FOR U.S.A. ONLY)
Direct Wire Connection
WARNING
3-wire direct Go to “Connecting 3-Wire Connection: Direct Wire” section.
Fire Hazard Use 10 gauge copper wire. Use a UL listed strain relief.
Disconnect power before making electrical connections. Connect neutral wire
(white or center wire) to center terminal. Ground wire (green or bare wire)
must be connected to green ground connector. Connect remaining 2 supply wires
to remaining 2 terminals. Securely tighten all electrical connections. Failure
to do so can result in death, fire, or electrical shock.
Connection Options
Direct Wire 4-wire direct Go to “Connecting 4-Wire Connection: Direct Wire”
section.
(251″mm)
(127
5″ mm)
NOTE: If local codes do not permit connection of a cabinet-ground conductor to neutral wire, go to “Connecting 3-Wire Connection: Optional” section. This connection may be used with either a power supply cord or a direct wire connection. Remove Terminal Block Cover
C
CB
D
B
E E
A AD
Before you start, disconnect power. Remove hold-down screw (D) and terminal
block cover (A).
A. Terminal block cover B. External ground conductor screw C. Center terminal
block screw D. Hold-down screw E. Neutral ground wire
21
ELECTRIC DRYER ELECTRICAL CONNECTIONS
Direct Wire Strain Relief 1. Insert strain relief. Unscrew the removable conduit connector (A) and any screws from a from a 3/4″ (19 mm) UL Listed strain relief. Put the threaded section of the strain relief (C) through the hole below the terminal block opening (B), screw the removable conduit connector (A) onto the strain relief threads.
2. Insert conduit into strain relief and tighten clamp. Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.
A B
C
Connecting 4-Wire Connection: Direct Wire
IMPORTANT: A 4-wire connection is required where local codes do not permit the
use of 3-wire connections. Direct wire cable must have 5 ft. (1.52 m) of extra
length so dryer can be moved if needed. Strip 5″ (127 mm) of outer covering
from end of cable, leaving bare ground wire at 5″ (127 mm). Cut 1½” (38 mm)
from three remaining wires. Strip insulation back 1″ (25 mm). Shape ends of
wires into a hook shape. Connecting Neutral Ground and Neutral Wires
1. Remove center terminal block screw (A) and neutral ground wire (B) by
removing the external ground connector screw (C).
Connecting Direct Wire Ground 3. Connect ground wire (green or bare) (E) with
external ground
connector screw (C). Tighten screw.
E C
Connecting Remaining Wires
4. Place hooked ends of remaining direct wire cables (hooks facing
right). Squeeze hooded ends together and tighten screws.
A
Finally, re-install terminal block cover and tighten hold-down
screw. Tighten screws. Go to “Complete Installation” section.
r
B C
2. Connect neutral ground (B) and place hooked end (hook facing right) of neutral wire (white or center wire) cable under center terminal block screw (B). Squeeze hooked end together. Tighten screw.
D B
22
ELECTRIC DRYER ELECTRICAL CONNECTIONS
Connecting 3-Wire Connection: Direct Wire
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
B
Direct wire cable must have 5 ft. (1.52 m) of extra length so
D
dryer can be moved if needed.
Strip 31/2″ (89 mm) of outer covering from end of cable. Strip insulation back 1″ (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of wires into a hook shape.
Connecting Neutral Wire 1. Loosen or remove center terminal block screw (A).
3. Place hooked ends of remaining direct wire cables (hooks
A
facing right). Squeeze hooded ends together and tighten screws. Finally, re- install terminal block cover and tighten
hold-down screw. Tighten screws. Go to “Complete
Installation” section.
2. Place hooked end (hook facing right) of neutral wire (white or center wire) (D) cable under center terminal block screw (B). Squeeze hooked end together. Tighten screw.
Connecting 3-Wire Connection: Optional
Use for direct wire or power supply cord where local codes do not permit
connecting cabinet-ground conductor to neutral wire.
Connecting Neutral Wire 1. Remove center terminal block screw (A). Also remove
neutral
ground wire (B) by removing external ground conductor screw (C).
3. Connect remaining wires under outer terminal block. Tighten screws.
A B
C 2. Connect neutral ground wire (B) and neutral wire (white or
center) (D) of power supply cord/cable under center terminal block. Tighten
screw.
D B
4. Connect a separate copper ground wire (G) under the external ground
conductor to screw (C) an adequate ground. Finally, re-install terminal block
cover and tighten hold-down screw. Go to “Complete Installation” section.
C G
23
COMPLETE INSTALLATION
1. Check the electrical requirements. Be sure that you have the correct
electrical supply and the recommended grounding method. See “Electrical
Requirements.”
2. Check that all parts are now installed. If there is an extra part, go back
through the steps.
3. Check that you have all of your tools. 4. Dispose of/recycle all packaging
materials. 5. Plug into a grounded outlet, or connect power. 6. Check dryer
operation. Close dryer door. Select the cycle. Using
a full heat cycle (not the air cycle), let the dryer run for at least five
minutes. Dryer will stop when time is used up. NOTE: Dryer door must be closed
for dryer to operate. When door is open, dryer stops, but timer continues to
run. To restart dryer, close door and re-select the cycle. 7. Open the dryer
door. Check that the inside of the dryer is warm. If the burner does not
ignite and you can feel no heat inside the dryer, shut off dryer for five
minutes. Check that all supply valve controls are in “ON” position and that
the electrical cord is plugged in. Repeat five-minute test. 8. If drying time
is too long, make sure that the lint screen is clean and that there are no
obstructions to airflow in the dryer vent system.
9. Restart the dryer and allow it to complete a full heat cycle (not air cycle) to make sure it is working properly.
24
REVERSING DRYER DOOR SWING (OPTIONAL)
You can change your door swing from a right-side opening to left-side opening, if desired.
Remove the Door Assembly 1. Place a towel or soft cloth on top of work space
to avoid
scratching of the surface. 2. Open dryer door. Remove button screws from
cabinet side
of hinges. Loosen (do not remove) top screws from cabinet side of hinges.
Plugs
Door catch
7. Be certain to keep cardboard spacer centered between doors. Reattach outer door panel to inner door panel so handle is on the side where hinges were just removed.
Hinges
8. Reattach screws at top, bottom, and side of door (Five screws).
3. Lift door until top screws in cabinet are in large part of hinge slot.
Pull forward off screws. Set door (handle side up) on top of towel. Remove top
screws from cabinet.
4. Remove screws attaching hinges to door. 5. Remove screws at top, bottom,
and side of door (Five screws).
9. Attach door hinges to dryer door so that larger hole is at the bottom of the hinge and the hinge pin is toward the door front.
6. Holding door over towel, grasp sides of outer door and gently lift to separate it from inner door. Do not use a putty knife to pry apart. Do not pull on door seal or plastic door catch.
10. Remove the Four screws that attach two plugs on the left side. Attach
plugs to right side using the same four screws.
11. Insert screws into bottom holes on left side of cabinet. Tighten screws
halfway. Position door so large end of door hinge slot is over screws. Slide
door up so screws are in bottom of slots. Tighten screws. Insert and tighten
top screws in hinges.
12. Close door and check that door strike aligns with door catch. If needed, slide door catch left or right within slot to adjust alignment. 25
MAINTENANCE INSTRUCTIONS
Clean lint screen before and after each cycle. Removing accumulated lint:
From inside the dryer cabinet: Lint should be removed every 2 years or more
often, depending on dryer usage. Cleaning should be done by a qualified
person. From the exhaust vent: Lint should be removed every 2 years, or more
often, depending on dryer usage. Keep area around dryer clear and free from
combustible materials, gasoline, and other flammable vapors and liquids. Keep
dryer area clear and free from items that would obstruct the flow of
combustion and ventilation air.
If dryer does not operate, check the following: Electrical supply is
connected. Circuit breaker is not tripped or house fuse is not blown. Door is
closed. Controls are set in a running or “on” position. Cycle has been
selected. For gas dryers, check that gas supply shut-off valves are set
in open position.
IF YOU NEED ASSISTANCE
Contact your authorized Commercial Laundry distributor. To locate your
authorized Commercial Laundry distributor, or for web inquiries, visit
www.maytagcommerciallaundry.com. If you cannot locate your distributor, the
Commercial Laundry Support Center will answer any questions about operating or
maintaining your dryer not covered in the “Installation Instructions.” Just
dial 1-800 NO BELTS (1-800-662-3587) —
the call is toll free. When you call, you will need the dryer model number and
serial number. Both numbers can be found on the serial-rating plate located in
the dryer door opening.
26
ELECTRONIC CONTROL SETUP INSTRUCTIONS
IMPORTANT Electrostatic Discharge (ESD)
Sensitive Electronics
ESD problems are present everywhere. ESD may damage or weaken the electronic
control assembly. The new control assembly may appear to work well after
repair is finished, but failure may occur at a later date due to ESD stress.
Use an anti-static wrist strap. Connect wrist strap to green
ground connection point or unpainted metal in the appliance. -OR-
Touch your finger repeatedly to a green ground connection point or unpainted
metal in the appliance. Before removing the part from its package, touch the
anti-static bag to a green ground connection point or unpainted metal in the
appliance. Avoid touching electronic parts or terminal contacts; handle
electronic control assembly by edges only. When repackaging failed electronic
control assembly in anti-static bag, observe above instructions.
General User Information
LOCATE KEY The key is located in the drum with this literature and foot
caps. DO NOT LOOSE this key-The key is used to enter service mode to allow you
to set up machine for use. The machines come preconfigured from the factory:
MODEL PD (coin drop or free vend see note):These models are configured for 30
min dryer cycle time at a cost of $1.50 per cycle as default from factory.
Mode 6 default is 06. Mode 7 default is 05. Price and Time is primarily set up
through mode 6 & 7. Mode 6 is how many quarters (i.e. default = 6 =$1.50) &
Mode 7 is how much cycle time per quarter. Mode 7 defaults to 5 from factory
(max time is 75 minutes). Mode 6 and 7 gets multiplied to determine cycle
time. (6X5=30 minutes per cycle by default.) Note: If you set mode 6 to 00,
this will be a free vend and the cycle time treats it as a 1 so if Mode 6=00
and Mode 7=45 the cycle time is 45 minutes and no cost. MODEL PR (free or pay
reader ready). These models default to mode 6=00 and Mode 7 = 45. This is a
free vend with a cycle time of 45 minutes, see explanation in PD section.
Key located inside drum
BLANK DISPLAY This condition indicates the dryer is inoperative. Enter set- up mode to view diagnostic code. “0 MINUTES” SHOWING IN DISPLAY This indicates the cycle is complete and the dryer cannot be operated. Coins dropped or debit inputs during this condition will be stored in escrow but cannot be used until normal operation is restored by opening and closing the door. If a door switch has failed, it must be replaced before normal operation can be restored. COLD START (Initial first use) Dryer is programmed at the factory as follows: 5 minutes dry time/quarter (coin 1) $1.50 dry price (fixed cycle with top off) WARM START (after power failure) A few seconds after power is restored, if a cycle was in progress at the time of the power failure, “RESELECT CYCLE” will flash in the display, indicating a button needs to be pressed to restart dryer. PRICING After the door is opened and then closed following the completion of a cycle, the display indicates the cycle price (unless set for free operation). As coins are dropped or debit inputs arrive, the display will change to lead the user through the initiation of a cycle. There are four (4) types of dryer pricing: Fixed “Vend” Pricing A dryer set up for “Fixed Cycle” operation can only accept additional time accumulated by increments equal to the length of a complete dry cycle. A maximum number of minutes may be purchased; no additional credit is given for coins dropped when the maximum minutes are displayed. Accumulator Pricing If the price is set to one coin 1, then accumulator pricing is in effect (Fixed Cycle with Top Off option must also be selected). Cycle time can be purchased one coin at a time up to the maximum time of 99 minutes. All money will be credited to a cycle with a single button press while in accumulator pricing. Fixed Cycle With Top Off Pricing A dryer set to offer “Top Off” capability will allow time to be added to an existing dry cycle in increments equal to the number of minutes of dry time per quarter (coin 1), up to the maximum minutes, regardless of the cost required to start the dryer. No credit is given for coins or debit inputs entered when the control is displaying the maximum minutes. Penny increment offset is not applied to top off purchases. FREE CYCLES This is established by setting the cycle price to zero. When this happens, “SELECT CYCLE” will appear rather than a cycle price. Any cycle started as a free cycle will automatically terminate when the door is opened. DEBIT CARD READY This dryer is debit card ready. It will accept a variety of debit card systems, but does NOT come with a debit card reader. Refer to the debit card reader manufacturer for proper dryer setup. In models converted to a Generation 1 debit card system, debit pulses represent the equivalent of one coin (coin 1).
27
ELECTRONIC CONTROL SETUP INSTRUCTIONS
Display Once the unit has been plugged in and the dryer door opened and closed, the display will show the price.
PRICE
1.50
PRICE
1.50
UPPER DRYER
WHITES & COLORS
HIGH HEAT
PERMANENT PRESS
MEDIUM HEAT
DELICATES LOW HEAT
WHITES & COLORS
HIGH HEAT
PERMANENT PRESS
MEDIUM HEAT
DELICATES LOW HEAT
LOWER DRYER
Control Set-up Procedures
IMPORTANT: Read all instructions before operating. The fabric setting buttons
along with the digital display are used to set up the dryer controls. The
display can contain 4 numbers and/or letters and a decimal point. These are
used to indicate the set-up codes and related code values available for use in
programming the appliance. How to Use the Buttons to Program the Controls
1. The WHITES AND COLORS button is used to adjust the values associated with
set-up code. Pressing the button will change the value by increments of one
(1). Rapid adjustment is possible by holding down the button.
2. The PERM. PRESS button will advance through the set-up codes. Pressing the
button will advance to the next available set-up code. Holding down the PERM.
PRESS button will automatically advance through the set-up codes at a rate
faster than one (1) per second.
3. The DELICATES button is used to select or deselect options. IMPORTANT: The
console must not be opened unless power is first removed from the dryer. To
access connector AA1: Unplug dryer or disconnect power. Open console,
disconnect plug on AA1, close console. Plug in dryer or reconnect power.
Insert access panel key and turn counterclockwise. If manual set-up card is
not available, manual set-up mode can be entered by turning the access panel
key. The dryer is now in the set-up mode. NOTE: This dryer is preset at the
factory and does not require any programming. However, if you want to change
the settings, follow the “Set-Up Codes” guide below. This dryer is pre-set at
the factory for fixed cycle price with
top off. Set-Up Codes
The PERM. PRESS button will advance you from code to code. The WHITES AND
COLORS button will change the code
value. The DELICATES button will select or deselect options. NOTE: On all
stacked dryer models, programming selections apply to both dryers. Stacked
dryer selections are accessed by pressing the LOWER DRYER buttons, you can not
program upper dyer differently than lower dryer and vice versa. The set-up
code is indicated by the one or two left-hand characters. The set-up code
value is indicated by the two or three right-hand characters.
Code Explanation
606 REGULAR CYCLE PRICE
Mode 6 allows you to set up how many quarters (coin 1) you want customers to
pay for cycle (i.e. if mode 6 set to 6 that means it will take 6 quarters or
$1.50 to start cycle).
606 Advance from 039 by pressing the WHITES AND COLORS button. Factory
default of 6 quarters = $1.50.
· Press the PERM. PRESS button once to advance to next code.
705 REGULAR DRY TIME
Mode 7 is the amount of time per cycle in minutes. It uses the number of quarters from mode 6 and multiplies to number set in mode 7 to give cycle time (i.e. if mode 6 =6 and mode 7=5, then the time per cycle is 6X5 or 30 minutes).
705 Factory default of 5 minutes per coin.
By pressing the WHITES AND COLORS button, value adjusts from 199 minutes.
· Press the PERM. PRESS button once to advance to next code.
800 TYPE OF DRYER PRICING
Mode 8 allows you to set up an additional time for user to keep clothes in and continue cycle (i.e. if set to 00 then customer can get an additional 5 min (factory default) cycle time for 1 quarter inserted.) If mode 8 set to FC then no top off allowed.
800 Fixed Cycle with Top Off.
8FC Fixed Cycle.
Use DELICATES button to make this selection.
COIN MODEL: Factory preset to 00
· Press the PERM. PRESS button once to advance to next code.
9 00
CYCLE COUNTER OPTION This option is either NOT SELECTED “OFF” or SELECTED “ON.”
MODE 9 allows you to keep track of how many cycles your machine has done.
9 00 Not Selected “OFF.”
9 0C
Selected “ON” and not able to be deselected.
· Press the DELICATES button 3 consecutive times to select “ON.” Once selected
“ON” it cannot be deselected.
· Press the PERM. PRESS button once to advance to next code.
If cycle counter (9 0C) is selected, the following is true:
1 00 2 00
Cycles in HUNDREDS Cycles in ONES
1 02 = 200 2 25 = 25
TOTAL CYCLES = 225 This is “VIEW ONLY” and cannot be cleared.
· Press the PERM. PRESS button once to advance to next code.
28
ELECTRONIC CONTROL SETUP INSTRUCTIONS
Code Explanation Mode 1.00 turns on how much money machine has collected if you would like to keep track of that.
1. 00
MONEY COUNTER OPTION This option is either NOT SELECTED “OFF” or SELECTED “ON.”
1. 00 Not Selected “OFF.”
1. 0C
Selected “ON.”
· Press the DELICATES button 3 consecutive times to select “ON” and 3
consecutive times to remove (Not Selected “OFF”). Counter resets by going from
“OFF” to “ON.”
1. C0
Selected “ON” and not able to be deselected.
· To select “ON” and not able to be deselected, first select “ON,” then within
2 seconds, press the DELICATES button twice, the WHITES AND COLORS button
once, and exit set-up mode.
· Press the PERM. PRESS button once to advance to next code.
Mode 2.00 allows you to set special pricing for instance different cost and/or different cycle times at specific times of specific day.
2. 00
SPECIAL PRICING OPTIONS This option is either NOT SELECTED “OFF” or SELECTED “ON.”
2. 00 Not Selected “OFF,” and next available code will be A.00.
2. SP
Selected “ON.”
· Press the DELICATES button once to change this selection.
If SPECIAL PRICING OPTION is selected, there is access to codes “3.XX” through
“9.XX.”
· Press the PERM. PRESS button once to advance to next code.
If money counter (1.0C or 1.C0) is selected, the following is true:
3 00 4 00 5 00
Dollars in HUNDREDS Dollars in ONES Number of CENTS
3 01 = $100.00 4 68 = $ 68.00 5 75 = $ 00.75
OPTIONS 3.XX 9.XX TO USE IF SPECIAL PRICING IS SELECTED. IF NOT IN SPECIAL PRICING THESE OPTIONS ARE IGNORED AND DEFAULTS BACK TO MODE 6 & 7 TIMES.
Code Explanation
3.06 SPECIAL CYCLE PRICE
3.06 Represents the number of quarters (coin 1) to start the dryer; may adjust from 039. (See VALUE OF COIN 1 b.05.)
Advance from 039 by pressing the WHITES AND COLORS button. Factory default of
6 quarters = $1.50.
· Press the PERM. PRESS button once to advance to next code.
4.05 SPECIAL DRY TIME
4.05 Represents the number of minutes per quarter (coin 1).
· Factory default of 5 minutes per coin. Example: 6 quarters x 5 minutes = 30
minutes.
· By pressing the WHITES AND COLORS button, the value can be adjusted from
199 minutes.
· Press the PERM. PRESS button once to advance to next code.
5. 00 TIME-OF-DAY CLOCK, MINUTES
5. 00
This is the TIME-OF-DAY CLOCK, minute setting; select 059 minutes by pressing
the WHITES AND COLORS button.
· Press the PERM. PRESS button once to advance to next code.
6. 00 TIME-OF-DAY CLOCK, HOURS
NOTE: Uses military time or 24 hr. clock.
6. 00
This is the TIME-OF-DAY CLOCK, hour setting; select 023 hours by pressing the
WHITES AND COLORS button.
· Press the PERM. PRESS button once to advance to next code.
TOTAL = $168.75
29
ELECTRONIC CONTROL SETUP INSTRUCTIONS
Code Explanation
7. 00 SPECIAL PRICE START HOUR
NOTE: Uses military time or 24 hr. clock.
7. 00
This is the start hour; 023 hours.
· Select START HOUR by pressing the WHITES AND COLORS button.
· Press the PERM. PRESS button once to advance to next code.
8. 00 SPECIAL PRICE STOP HOUR
NOTE: Uses military time or 24 hr. clock.
8. 00
This is the stop hour; 023 hours.
· Select STOP HOUR by pressing the WHITES AND COLORS button.
· Press the PERM. PRESS button once to advance to next code.
9. 10 SPECIAL PRICE DAY
9. 10
This represents the day of the week and whether special pricing is selected for that day. A number followed by “0” indicates no selection that particular day (9.10). A number followed by an “S” indicates selected for that day (9.1S). Days of the week (17) are selected by pressing the WHITES AND COLORS button. Press the DELICATES button once to select special pricing for each day chosen.
When exiting set-up code “9,” the display must show the current day of week:
DISPLAY
DAY OF WEEK
CODE (selected)
10
Day 1 = Sunday
1S
20
Day 2 = Monday
2S
30
Day 3 = Tuesday
3S
40
Day 4 = Wednesday
4S
50
Day 5 = Thursday
5S
60
Day 6 = Friday
6S
70
Day 7 = Saturday
7S
· Press the PERM. PRESS button once to advance to next code.
A. 00
VAULT VIEWING OPTION This option is either NOT SELECTED “OFF” or SELECTED “ON.”
In Mode A if it is set to SC, you can view money and/or cycle counts when the coin holder box is removed.
A. 00 Not Selected “OFF.”
A. SC
Selected “ON.”
· Press the DELICATES button once to change this selection. When selected, the
money and/or cycle counts will be viewable (if counter option(s) is selected)
when the coin box is removed.
· Press the PERM. PRESS button once to advance to next code.
Code Explanation
b. 05 VALUE OF COIN 1
Mode b is where you set up how much 1 coin value is in nickles for
coin1 input-this is the default (ie. 05=$0.25).
b. 05
· By pressing the WHITES AND COLORS button, there
is an option of 1199 nickels.
· Press the PERM. PRESS button once to advance
to next code.
C. 20 VALUE OF COIN 2
Mode C is the same as b, however this is the set up for Coin 2 input value in nickels. (this is for two different coins, if you have a $1.00 coin and $0.25 coin) otherwise the Coin 1 is set for all models and defaults to 1 quarter or $0.25.
C. 20
This represents the value of coin 2 in number of nickels: 20 = $1.00.
· By pressing the WHITES AND COLORS button, there is an option of 1199
nickels.
· Press the PERM. PRESS button once to advance to next code.
E. 00
ADD COINS OPTION This option is either NOT SELECTED “OFF” or SELECTED “ON.” This option causes the customer display to show the number of coins (coin 1) to enter, rather than the dollars-and-cents amount. The number in the display changes as the coins are accepted.
MODE E allows you to change display to show how many coins left to add to start cycle or the price to add for the cycle.
E. 00 Not Selected “OFF.”
E. AC
Selected “ON.”
· Press the DELICATES button 3 consecutive times to change this selection.
· Press the PERM. PRESS button once to advance to next code.
30
ELECTRONIC CONTROL SETUP INSTRUCTIONS
Code Explanation
J. Cd PAYMENT MODE (COIN/DEBIT OPTION)
MODE J is the mode that the control is in, a PD model =JCd(default) and a PR model =_d (default) for debit.
J. Cd Both coin and debit selected. Press the DELICATES button 3 consecutive times to change this selection.
J. C_ Coins selected, debit disabled. Press the DELICATES button 3 consecutive times to change this selection.
J._d Debit Card selected, coins disabled. Press the DELICATES button 3 consecutive times to change this selection.
J. Ed
Enhanced Debit is self-selected when a Generation 2 card reader is installed
in the dryer. The Ed option cannot be manually selected or deselected.
· Press the PERM. PRESS button once to advance to next code.
L. 00
PRICE SUPPRESSION OPTION This option is either NOT SELECTED “OFF” or SELECTED “ON.”
MODE L allows you to have control display ADD if more money needed to start cycle or Available after payment completed if L=PS. (It still displays card balance amount if applicable).
L. 00 Not Selected “OFF.”
L. PS
Selected “ON.”
· Press the DELICATES button once to change this selection.
· Press the PERM. PRESS button once to advance to next code.
MODE n allows you to clear escrow in 30 minutes meaning machine will not maintain escrow longer than 30 minutes when set to CE.
n. CE
CLEAR ESCROW OPTION This option is either NOT SELECTED “OFF” or SELECTED “ON.” When selected, money held in escrow for 30 minutes without further escrow or cycle activity will be cleared.
n. 00 Not Selected “OFF.”
n. CE
Selected “ON.”
· Press the DELICATES button once to change this selection.
· Press the PERM. PRESS button once to advance to next code.
END of SET-UP PROCEDURES EXIT FROM SET-UP MODE Stacked Models: Turn access panel key back to original position.
DIAGNOSTIC GUIDE If the set-up mode is entered and one of the following has occurred, the appropriate diagnostic code will be in the display.
STACKED DRYERS
CODE
EXPLANATION
d1
Invalid upper dryer door circuit
state The CSP Venus control
does not differentiate between
invalid state and open door
state.
CODE d4
d5 d9 d12 d13 d14 d16 d17 d20 d23 d24
EXPLANATION The CSP Venus control will send this error when the upper motor
feedback circuit is sensing voltage with the door open or when the motor
should not be on. The control does not know if the relay is bad (stuck on),
the relay drive circuit is bad (shorted causing the motor relay to stay on),
or the relay fedback circuit is bad. Coin 1 Failure. Screen goes blank. Switch
over to service mode verify d5 error. Check connector AA4 for connection and
verify coin 1 drop for blockage. Low voltage Lower dryer motor sense circuit
error on control board or due to power line interference (lower dryer cycles
and lower dryer display disabled until diagnostic code is manually cleared).
Coin 2 failure. Screen goes blank. Switch over to service mode verify d13
error. Check coin 2 connector AA5 and verify coin drop 2 for blockage. Upper
dryer motor sense: Upper dryer screen disabled. Ensure connector AA7
connected. Gen 2 debit card communication error. Unplug card reader and plug
it back in to allow it to reboot. Lower dryer door sense error on control
board or due to power line interference (lower dryer cycles and lower dryer
display disabled until diagnostic code is manually cleared). Lower dryer motor
control circuit error (lower dryer cycles and lower dryer display disabled
until diagnostic code is manually cleared).
Upper button stuck switch (upper dryer cycle and upper dryer display disabled
for 30s or diagnostic code cleared). Function will return normal if stuck
switch no longer detected. Lower button stuck switch (lower dryer cycle and
lower dryer display disabled for 30s or diagnostic code cleared) Function will
return normal if stuck switch no longer detected.
31
MAYTAG® COMMERCIAL LAUNDRY LIMITED WARRANTY
IF YOU NEED SERVICE:
Contact your authorized Maytag® Commercial Laundry distributor. To locate your
authorized Maytag® Commercial Laundry distributor, visit
www.MaytagCommercialLaundry.com.
For written correspondence:
Maytag® Commercial Laundry Service Department
2000 N M 63 Benton Harbor, Michigan 49022-2632 USA
WHAT IS COVERED
FIVE YEAR LIMITED WARRANTY WHAT IS NOT COVERED
FIVE YEAR LIMITED WARRANTY (PARTS ONLY — LABOR NOT INCLUDED)
For the first five years from the original date of purchase, when this
commercial appliance is installed, maintained, and operated according to the
instructions attached to or furnished with the product, Maytag brand of
Whirlpool Corporation (hereafter “Maytag”) will pay for factory specified
replacement parts to correct defects in materials or workmanship that existed
when this commercial appliance was purchased. This limited warranty does not
include labor.
YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT
REPAIR AS PROVIDED HEREIN. Maytag recommends that you use an “in network”
service provider to diagnose and repair your Commercial Laundry product.
Maytag will not be responsible under this warranty to provide additional
replacement parts as a result of incorrect diagnosis or repair by an “out of
network” service company. This limited warranty is valid in the United States
or Canada and applies only when the commercial appliance is used in the
country in which it was purchased. This limited warranty is effective from the
date of the original consumer purchase. Proof of original purchase date is
required to obtain service under this limited warranty.
1. All other costs including labor, transportation, shipping, or custom
duties for covered parts.
2. Factory specified replacement parts if this commercial appliance is used
for other than normal, commercial use or when it is used in a manner that is
inconsistent to published user or operator instructions and/or installation
instructions.
3. Service calls to correct the installation of your commercial appliance, to
instruct you on how to use your commercial appliance, to replace or repair
house fuses, or to correct external wiring or plumbing.
4. Service calls to repair or replace appliance light bulbs, air filters, or
water filters. Consumable parts are excluded from warranty coverage.
5. Damage resulting from improper handling of product during delivery, theft,
accident, alteration, misuse, abuse, fire, flood, acts of God, improper
installation, installation not in accordance with local electrical or plumbing
codes, or use of products not approved by Maytag.
6. Pick up and delivery. This commercial appliance is designed to be repaired
on location.
7. Repairs to parts or systems resulting from unauthorized modifications made
to the commercial appliance.
8. The removal and reinstallation of your commercial appliance if it is
installed in an inaccessible location or is not installed in accordance with
published installation instructions.
9. Damage resulting from exposure to chemicals.
10. Changes to the building, room, or location needed in order to make the
commercial appliance operate correctly.
11. Factory specified replacement parts on commercial appliances with
original model/serial numbers that have been removed, altered, or cannot be
easily determined.
12. Discoloration, rust, or oxidation of stainless steel surfaces. 13.
Factory specified replacement parts as a result of incorrect diagnosis or
repair
by an “out of network” service company. The cost of repair or replacement
under these excluded circumstances shall be borne by the customer.
DISCLAIMER OF IMPLIED WARRANTIES IMPLIED WARRANTIES, INCLUDING ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE, ARE LIMITED TO FIVE YEARS OR THE SHORTEST PERIOD ALLOWED BY LAW. Some
states and provinces do not allow limitations on the duration of implied
warranties of merchantability or fitness, so this limitation may not apply to
you. This warranty gives you specific legal rights, and you also may have
other rights that vary from state to state or province to province.
DISCLAIMER OF REPRESENTATIONS OUTSIDE OF WARRANTY Maytag makes no
representations about the quality, durability, or need for service or repair
of this major appliance other than the representations contained in this
Warranty. If you want a longer or more comprehensive warranty than the limited
warranty that comes with this major appliance, you should ask Maytag or your
retailer about buying an extended warranty.
LIMITATION OF REMEDIES; EXCLUSION OF INCIDENTAL AND CONSEQUENTIAL DAMAGES YOUR
SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR
AS PROVIDED HEREIN. MAYTAG SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL
DAMAGES. Some states and provinces do not allow the exclusion or limitation of
incidental or consequential damages, so these limitations and exclusions may
not apply to you. This warranty gives you specific legal rights, and you also
may have other rights that vary from state to state or province to province.
08/16
32
SÉCURITÉ DE LA SÉCHEUSE
Votre sécurité et celle des autres est très importante.
Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur
votre appareil ménager. Assurez-vous de toujours lire tous les messages de
sécurité et de vous y conformer.
Voici le symbole d’alerte de sécurité.
Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès
et de blessures graves à vous et à d’autres.
Tous les messages de sécurité suivront le symbole d’alerte de sécurité et le
mot “DANGER” ou “AVERTISSEMENT”. Ces mots signifient :
DANGER
Risque possible de décès ou de blessure grave si vous ne suivez pas immédiatement les instructions.
AVERTISSEMENT
Risque possible de décès ou de blessure grave si vous ne suivez pas les instructions.
Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et ce qui peut se produire en cas de non-respect des instructions.
On recommande que le propriétaire place les instructions à l’usage du client
en un lieu bien visible, au cas où le client percevrait une odeur de gaz. Ces
renseignements doivent être obtenus auprès de votre fournisseur en gaz.
Placer l’avertissement qui suit à un endroit bien visible.
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ
Avant de jeter ou de ranger votre vieille sécheuse, enlever la porte.
CONSERVEZ CES INSTRUCTIONS 33
SÉCURITÉ DE LA SÉCHEUSE
AVERTISSEMENT :
RISQUE D’INCENDIE OU D’EXPLOSION
Le non-respect des avertissements de sécurité peut causer des dommages à la
propriété, des blessures graves, voire la mort. Ne pas entreposer ou
utiliser de l’essence ou d’autres vapeurs ou liquidesinflammables
à proximité de cet appareil ou de tout autre appareil électroménager.
QUE FAIRE DANS LE CAS D’UNE ODEUR DE GAZ :
· Ne pas tenter d’allumer un appareil.
·
Ne pas sur les
toucher lieux.
à
un
commutateur
électrique;
ne
pas
utiliser
le
téléphone
se
trouvant
· Évacuer tous les gens de la pièce, de l’édifice ou du quartier.
·
Appeler immédiatement instructions.
le
fournisseur
de
gaz
d’un
téléphone
voisin.
Suivre
ses
· À défaut de joindre votre fournisseur de gaz, appeler les pompiers.
L’installation et l’entretien doivent être effectués par un installateur qualifié, uneagence de service ou le fournisseur de gaz.
AVERTISSEMENT : L’odorat ne permet pas toujours la détection d’une fuite de gaz. Les distributeurs de gaz recommandent l’emploi d’un détecteur de gaz (homologation UL ou CSA). Pour d’autres informations, contacter le fournisseur de gaz local. En cas de détection d’une fuite de gaz, exécuter les instructions “Que faire dans le cas d’une odeur de gaz”.
Dans l’État du Massachusetts, les instructions d’installation suivantes sont
applicables : Les travaux d’installation et réparation doivent être exécutés
par un plombier ou tuyauteur qualifié ou licencié, ou par le personnel
qualifié d’une entreprise licenciée par l’État du Massachusetts. Remplacer par
des dispositifs de fermeture acceptables : Les robinets de gaz et robinets à
bille installés pour l’utilisation devraient être indiqués. Si un conduit de
raccordement flexible est utilisé, sa longueur ne doit pas dépasser 4 pi
(121,9 cm).
IMPORTANT : L’installation du gaz doit se conformer aux codes locaux, ou en
l’absence de codes locaux, au code d’installation du gaz naturel ou du
propane, CSA B149.1. La sécheuse doit être électriquement reliée à la terre
conformément aux codes locaux, ou en l’absence de codes locaux, au Code
canadien de l’électricité, partie 1, CSA C22.1.
34
SÉCURITÉ DE LA SÉCHEUSE
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ
AVERTISSEMENT : Pour réduire les risques d’incendie, de choc électrique ou de
blessures lors de l’utilisation de la sécheuse, suivre les précautions
fondamentales dont les suivantes :
Lire toutes les instructions avant d’utiliser la sécheuse. Cette sécheuse est
conçue uniquement pour le séchage
de vêtements et de textiles ayant été nettoyés à l’eau. Ne pas l’utiliser à
toute autre fin. AVERTISSEMENT: Si l’on détecte une odeur de gaz, ne pas
utiliser la sécheuse ou tout autre équipement électrique situé à proximité.
Avertir les autres personnes qu’elles doivent évacuer cette zone. Contacter le
propriétaire de la sécheuse immédiatement. Ne pas placer des articles exposés
aux huiles de cuisson dans votre sécheuse. Les articles contaminés par des
huiles de cuisson peuvent contribuer à une réaction chimique qui pourrait
causer à la charge de s’enflammer. Pour réduire le risque d’incendie dû à des
charges contaminées, la partie finale du programme de séchage par culbutage a
lieu sans chaleur (période de refroidissement). Éviter d’arrêter une sécheuse
en phase de culbutage avant la fin du programme de séchage, à moins de retirer
et d’étendre rapidement tous les articles afin que la chaleur se dissipe. Ne
pas faire sécher des articles qui ont été nettoyés ou lavés avec de l’essence
ou imbibés d’essence, solvants de nettoyage à sec, ou autres substances
inflammables ou explosives; ces substances peuvent émettre des vapeurs
susceptibles de s’enflammer ou d’exploser. Ne pas faire sécher dans la
sécheuse des articles nonlavés. Ne pas laisser des enfants jouer sur ou à
l’intérieur de la sécheuse. Bien surveiller les enfants lorsque la sécheuse
est utilisée à proximité d’enfants. Avant de retirer la sécheuse pour un
dépannage ou pour le jeter, ôter les portes des compartiments de la sécheuse.
Ne pas tenter d’atteindre un article à l’intérieur de la cuve de la sécheuse
lorsque le tambour est en mouvement. Ne pas ouvrir le couvercle lorsque la
sécheuse est en marche. Il s’arrêtera. Ne pas installer ou remiser cette
sécheuse à un endroit où il serait exposée à l’eau et/ou aux intempéries. Ne
pas modifier les organes de commande. Nettoyer le filtre à charpie avant et
après chaque charge.
Ne pas utiliser cette sécheuse si le filtre à peluches n’est pas installé.
Ne pas réparer ou remplacer un composant quelconque de la sécheuse, ni
entreprendre une opération de service, si ce n’est spécifiquement recommandé
dans ce manuel ou dans un manuel d’instructions de réparations destiné à
l’utilisateur; il est alors essentiel que la personne concernée comprenne ces
instructions et soit compétente pour les exécuter.
Ne pas utiliser un produit assouplissant de tissu ou des produits pour
éliminer la statique à moins qu’ils ne soient recommandés par le fabricant du
produit assouplissant de tissu ou du produit.
Ne pas utiliser la chaleur pour faire sécher des articles fabriqués avec du
caoutchouc mousse ou de matériaux semblables.
La dernière partie d’un programme de séchage par culbutage a lieu sans chaleur
(programme de refroidissement) pour faire en sorte que les articles soient
laissés à une température qui garantit que les articles ne seront pas
endommagés.
AVERTISSEMENT : Ne jamais arrêter le séchage par culbutage avant la fin du
programme de séchage sauf si tous les articles sont retirés rapidement et
répartis pour une dissipation de la chaleur (permet d’éviter le risque de
combustion spontanée).
Ne pas laisser la charpie, la poussière, ou la saleté s’accumuler autour du
système d’évacuation ou autour de l’appareil.
Un nettoyage périodique de l’intérieur de la sécheuse et du conduit
d’évacuation doit être effectué par une personne qualifiée.
Voir la section “Spécifications électriques” dans les instructions
d’installation pour les instructions de mise à la terre.
AVERTISSEMENT : Ne pas installer de ventilateur secondaire dans le conduit
d’évacuation. REMARQUE : L’avertissement de ventilateur secondaire ne
s’applique pas aux sécheuses conçues pour être installées dans un système où
il y a plusieurs sécheuses, avec un système de conduit d’évacuation conçu sur
mesure et installé selon les directives du fabricant de la sécheuse.
CONSERVEZ CES INSTRUCTIONS
35
OUTILS ET PIÈCES
Outillage nécessaire :
Clé à tuyau de 8″ (200 mm) ou 10″ (250 mm)
Clé à molette de 8″ (200 mm)
Tournevis à lame plate
ou 10″ (250 mm) (ouverture
jusqu’à 1″ [25 mm])
Tournevis Phillips
Tournevis isolé ou foret
Clé à douille hexagonale
Torx T-20®
de 1″ (25 mm)
Clé à douille de 5/16″ (8 mm)
Pince (ouverture
jusqu’à 19/16″ [39 mm])
Niveau
Couteau utilitaire
Tourne-écrou de 1/4″ (6 mm)
Cale de bois de 27″ (686 mm)
Pistolet à calfeutrage et composé de calfeutrage (pour l’installation d’un
nouveau
conduit d’évacuation)
Brides de conduit
Composé d’étanchéité
Couteau à mastic
des tuyauteries résistant au type
de gaz utilisé
Lampe de poche (facultative)
Pièces fournies :
Clés plates de 1″ (25 mm)
Règle ou mètre ruban
Goupilles bêta de sécurité (2) (situées dans le sac à l’intérieur du tambour)
Patins (4) (situées dans le sac à l’intérieur du tambour)
Pieds de nivellements (4) (déjà installés sur la sécheuse)
® TORX et T-20 sont des marques déposées de Acument Intellectual Properties,
LLC.
36
Dimensions Vue de face
DIMENSIONS/DISTANCES DE DÉGAGEMENT
Vue latérale
Vue arrière
Distances de dégagement Encastrement, vue avant
Électrique Gaz
Encastrement, vue latérale
12″ (300 mm)
Closet
0″ (0 mm)
21/4″ (57 mm)
DiCmloesnestioDnosordM’éinviemnutm miAncicmeaptleabsleacVceenpt Staizbeles s
de la porte du placard
3″ (76 mm) 76mm)
484i8ncpho2es2 (310 cm2)
310 cm2)
1″
(25 mm) Porte deCplloasceat rddooàr l’avant de la sétochfreountsoef dryer
3″/33″ ” (76 mm)
242i4ncpho2es2 (155 cm2)
37
EXIGENCES DE L’EMPLACEMENT
AVERTISSEMENT
Risque d’explosion Garder les matières et les vapeurs inflammables, telle que
l’essence, loin de la sécheuse. Ne pas installer dans un garage. Le non-
respect de ces instructions peut causer un décès, une explosion ou un
incendie.
La sécheuse peut être installée dans un sous-sol, une salle de buanderie ou un
encastrement. Cette sécheuse n’est pas prévue pour une installation en
résidence mobile. Il faut aussi prendre en compte les exigences d’emplacement
des appareils voisins. IMPORTANT : Ne pas installer ou remiser la sécheuse
dans un endroit où elle
sera exposée à l’eau et/ou aux intempéries. C’est à l’utilisateur qu’incombe
la responsabilité de réaliser une installation correcte. Il vous faudra : Une
prise électrique reliée à la terre située à moins de 6 pi (1,8 m) de la prise
du cordon électrique se trouvant à l’arrière de la sécheuse. Voir
“Spécifications électriques”. Un plancher de niveau ayant une pente maximale
de 1″ (25 mm) sous l’ensemble de la sécheuse. L’installation de la sécheuse
sur des surfaces de sol molles, telles que tapis ou surfaces avec sous-couche
en mousse n’est pas recommandée.
Distances de dégagement pour l’installation pour la sécheuse L’emplacement
doit être assez grand pour permettre d’ouvrir
complètement la porte de la sécheuse. Prévoir davantage d’espace pour
faciliter l’installation
et l’entretien. La porte s’ouvre à plus de 180°. Un espace supplémentaire peut
être requis pour les moulures
de porte et de plancher et pour les plinthes. Un espace supplémentaire de 1″
(25 mm) de tous les côtés de
la sécheuse est recommandé pour réduire le transfert du bruit. L’arrière de la
sécheuse doit être placé contre le mur.
Consulter les dimensions/dégagements d’installation minimum dans les schémas.
Lors de l’installation d’une sécheuse à gaz : IMPORTANT : Observer les
dispositions de tous les codes et règlements en vigueur. Vérifier les
exigences des codes : Certains codes limitent ou n’autorisent pas
l’installation d’une sécheuse dans un garage, un placard ou une chambre à
coucher. Communiquer avec l’inspecteur en bâtiments local. S’assurer que les
rebords inférieurs de la caisse ainsi que les côtés arrière et inférieurs de
la sécheuse, sont bien dégagés pour permettre une évacuation adéquate de l’air
de combustion. Voir la section “Instructions d’installation dans un
encastrement” ci-dessous pour connaître les distances de dégagement minimales.
Instructions d’installation dans un encastrement Cette sécheuse peut être
installée dans un encastrement. Pour les installations dans un encastrement,
les distances de dégagement minimales sont indiquées sur l’étiquette
d’avertissement à l’arrière de la sécheuse ou à la section
“Dimensions/Distances de dégagement”. Les dimensions d’installation sont en
pouces et constituent le minimum applicable. Un espace supplémentaire peut
être nécessaire pour faciliter l’installation, l’entretien et pour observer
les codes et règlements locaux. La sécheuse doit être évacuée à l’extérieur.
38
EXIGENCES ÉLECTRIQUES POUR LA SÉCHEUSE À GAZ
AVERTISSEMENT
Mise à la terre de la sécheuse à gaz
Risque de choc électrique Brancher sur une prise à 3 alvéoles reliée à la
terre. Ne pas enlever la broche de liaison à la terre. Ne pas utiliser un
adaptateur. Ne pas utiliser un câble de rallonge. Le non-respect de ces
instructions peut causer un décès, un incendie ou un choc électrique.
IMPORTANT : La sécheuse doit être reliée à la terre conformément aux codes et
règlements locaux en vigueur, ou en l’absence de tels codes, avec la dernière
édition du National Electrical Code, ANSI/NFPA 70, ou du Canadian Electrical
Code, CSA C22.1. Si les codes le permettent et si on utilise un conducteur
distinct de liaison à la terre, il est recommandé qu’un électricien qualifié
vérifie la qualité de la liaison à la terre. Pour obtenir un exemplaire des
normes des codes ci-dessus, contacter :
National Fire Protection Association One Batterymarch Park, Quincy, MA 02269
CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575 Ne
pas utiliser une tuyauterie de gaz pour le raccordement à la terre. Ne pas
installer un fusible dans le conducteur neutre ou le circuit de liaison à la
terre. Une alimentation de 120 V, 60 Hz, CA seulement, de 15 ou 20 A, protégée
par un fusible est requise. On recommande également d’utiliser un fusible ou
un disjoncteur temporisé. Il est recommandé de raccorder la sécheuse sur un
circuit distinct exclusif à cet appareil. Si les codes le permettent et si
l’on utilise un conducteur distinct de liaison à la terre, il est recommandé
qu’un électricien qualifié vérifie la qualité de la liaison à la terre. En cas
de doute quant à la qualité de la liaison à la terre de la sécheuse, consulter
un électricien qualifié.
39
EXIGENCES DE GAZ
Alimentation en gaz
AVERTISSEMENT
Risque d’explosion Utiliser une canalisation neuve d’arrivée de gaz approuvée
par CSA International. Installer un robinet d’arrêt. Bien serrer chaque organe
de connexion de la canalisation de gaz. En cas de connexion au gaz propane,
demander à une personne qualifiée de s’assurer que la pression de gaz ne
dépasse pas 330 mm (13 po) de la colonne d’eau. Par personne qualifiée, on
comprend : le personnel autorisé de chauffage, le personnel autorisé d’une
compagnie de gaz, et le personnel d’entretien autorisé. Le non-respect de ces
instructions peut causer un décès, un explosion ou un incendie.
IMPORTANT : Observer les dispositions de tous les codes et règlements en
vigueur. L’installation doit satisfaire aux critères de tous les codes et
règlements locaux. En l’absence de code local, l’installation doit satisfaire
aux prescriptions de la norme American National Standard, National Fuel Gas
Code ANSI Z223.1/NFPA 54 ou CAN/CSA B149. Pour obtenir un exemplaire des
normes des codes ci-dessus, contacter :
National Fire Protection Association One Batterymarch Park, Quincy, MA 02269
CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575 La
conception de cette sécheuse a été homologuée par CSA International pour une
utilisation jusqu’à une altitude de 10 000 pieds (3 048 m) au-dessus du niveau
de la mer pour le débit thermique indiqué sur la plaque signalétique. Aucun
réglage du brûleur n’est nécessaire lorsque la sécheuse est utilisée à une
altitude inférieure ou égale à cette valeur maximale. Lorsque l’appareil est
installé à une altitude supérieure à 10 000 pieds (3 048 m), on doit réduire
de 4 % le débit thermique du brûleur indiqué sur la plaque signalétique pour
chaque tranche de 1 000 pieds (305 m) d’augmentation de l’altitude. Pour
obtenir de l’aide lors de la conversion à d’autres types de gaz et/ou
l’installation de l’appareil à une altitude supérieure à 10 000 pieds (3048
m), contacter la société de dépannage la plus proche.
40
SPÉCIFICATIONS ÉLECTRIQUES DE LA SÉCHEUSE ÉLECTRIQUE (É.-U. SEULEMENT)
C’est à l’utilisateur qu’incombe la responsabilité de : Contacter un
électricien qualifié. S’assurer que le raccordement électrique est adéquat et
conforme au code national de l’électricité, ANSI/NFPA 70 dernière édition,
et à tous les codes et règlements locaux en vigueur. Le National Electrical
Code impose un raccordement à 4 fils de l’alimentation électrique pour les
maisons construites après 1996, les circuits de sécheuse modifiés après 1996
et toutes les installations de maisons mobiles. Pour obtenir un exemplaire des
normes des codes cidessus, contacter : National Fire Protection Association,
One Batterymarch Park, Quincy, MA 02269. L’appareil doit être alimenté
uniquement par un circuit monophasé à 3 ou 4 fils de 120/240 V CA, 60 Hz (ou 3
ou 4 fils, 120/208 V, si précisé sur la plaque signalétique) sur un circuit
séparé et protégé par un fusible ou un disjoncteur de 30 A sur chacun des 2
câbles. On recommande d’utiliser un fusible ou un disjoncteur temporisé. On
recommande également que cet appareil soit alimenté par un circuit
indépendant. Ne pas avoir de fusible dans le circuit neutre ou de liaison à la
terre. Ne pas utiliser de rallonge. Si les codes le permettent et si on
utilise un conducteur distinct de liaison à la terre, il est recommandé qu’un
électricien qualifié vérifie la qualité de la liaison à la terre.
Mise à la terre de la sécheuse électrique
Raccordement électrique Pour installer la sécheuse de façon appropriée, il
faut établir le type de raccords électriques que l’on utilisera et suivre les
instructions de ce document.
Cette sécheuse est prête à l’installation avec un raccordement à
l’alimentation électrique à 3 fils. Le fil de terre neutre est définitivement
raccordé au conducteur neutre (fil blanc) à l’intérieur de la sécheuse. Si la
sécheuse est installée avec un raccordement à 4 fils à l’alimentation
électrique, le fil de terre neutre doit être retiré de la vis du connecteur de
terre externe (vis verte) et fixé sous la borne du neutre (fil du centre ou
blanc) du bornier. Lorsque le fil de terre neutre est fixé sous la borne du
neutre (fil du centre ou blanc) du bornier, la caisse de la sécheuse est
isolée du conducteur neutre.
Si les codes locaux n’autorisent pas le raccordement d’un conducteur de
liaison à la terre au fil neutre, voir “Raccordement optionnel à 3 fils”.
Un raccordement à 4 fils de l’alimentation électrique doit être utilisé
lorsque l’appareil est installé dans un lieu où la mise à la terre par le
conducteur neutre est interdite. Il est interdit de relier l’appareil à la
terre par l’intermédiaire du conducteur neutre dans les cas suivants : (1)
nouvelle installation de circuit de dérivation, et (2) juridictions dans
lesquelles le code local interdit la liaison à la terre par l’intermédiaire du
conducteur neutre.
41
SPÉCIFICATIONS ÉLECTRIQUES DE LA SÉCHEUSE ÉLECTRIQUE (É.-U. SEULEMENT)
Cordon d’alimentation de la sécheuse
AVERTISSEMENT
Si la prise murale ressemble à ceci :
Prise murale à 3 conducteurs (10-30R)
Choisir un cordon d’alimentation à 3 fils avec cosses rondes ou à fourche et un serre-câble homologué UL. Le cordon d’alimentation électrique à 3 fils, d’au moins 4 pi (1,22 m) de long, doit comporter trois fils en cuivre torsadés de calibre no 10 et une fiche à 3 fils correspondante de type NEMA 10-30R.
Risque d’incendie
Utiliser un cordon d’alimentation électrique neuf homologué UL de 30 ampères.
Utiliser un réducteur de tension homologué UL.
Déconnecter la source de courant électrique avant de réaliser les connexions
électriques.
Connecter le conducteur neutre (blanc ou conducteur central) à la borne
centrale (argent).
Le conducteur de liaison à la terre (vert ou nu) doit être relié au connecteur
vert de liaison à la terre.
Connecter les 2 conducteurs d’alimentation restants aux 2 bornes restantes.
Bien serrer chaque organe de connexion du branchement électrique.
Le non-respect de cette instruction peut causer un décès, un incendie ou un
choc électrique.
En cas d’utilisation d’un cordon d’alimentation : Utiliser un ensemble de
cordon d’alimentation électrique homologué UL marqué pour utilisation avec les
sécheuses à vêtements. L’ensemble doit contenir : Un cordon d’alimentation
électrique homologué UL de 30 A,
120/240 V minimum. Le cordon doit être de type SRD ou SRDT et mesurer au moins
4 pi (1,22 m) de long. Les fils raccordés à la sécheuse doivent se terminer
par des cosses rondes ou des cosses en “U” à fourche, à pointes relevées. Un
serre-câble homologué UL.
Si la prise murale ressemble à ceci :
Prise murale à 4 conducteurs (14-30R)
Choisir un cordon d’alimentation à 4 fils avec cosses rondes ou à fourche et un serre-câble homologué UL. Le cordon d’alimentation électrique à 4 fils, d’au moins 4 pi (1,22 m) de long, doit avoir 4 fils en cuivre torsadés de calibre no 10 et une fiche à 4 fils correspondante de type NEMA 14-30R. Le fil de liaison à la terre (le conducteur de liaison à la terre) peut être vert ou nu. Le conducteur neutre doit être identifié par une gaine blanche.
Câblage direct
AVERTISSEMENT
Risque d’incendie Utiliser du fil en cuivre solide de calibre 10. Utiliser un
réducteur de tension homologué UL. Déconnecter la source de courant électrique
avant de réaliser les connexions électriques. Connecter le conducteur neutre
(blanc ou conducteur central) à la borne centrale. Le conducteur de liaison à
la terre (vert ou nu) doit être relié au connecteur vert de liaison à la
terre. Connecter les 2 conducteurs d’alimentation restants aux 2 bornes
restantes. Bien serrer chaque organe de connexion du branchement électrique.
Le non-respect de cette instruction peut causer un décès, un incendie ou un
choc électrique.
Pour le raccordement direct : Le câble à raccordement direct doit correspondre
à l’alimentation électrique (4 fils ou 3 fils) et être : Un câble en cuivre à
gaine non métallique ou blindé souple
(avec fil de liaison à la terre), avec conduit métallique souple. Tous les
fils sous tension doivent être isolés. Conducteur en cuivre de calibre 10 (ne
pas utiliser d’aluminium). D’au moins 5 pi (1,52 m) de long.
42
SPÉCIFICATIONS ÉLECTRIQUES DE LA SÉCHEUSE ÉLECTRIQUE (CANADA SEULEMENT)
Câblage direct
AVERTISSEMENT
Risque d’incendie Utiliser du fil en cuivre solide de calibre 10. Utiliser un
réducteur de tension homologué UL. Déconnecter la source de courant électrique
avant de réaliser les connexions électriques. Connecter le conducteur neutre
(blanc ou conducteur central) à la borne centrale. Le conducteur de liaison à
la terre (vert ou nu) doit être relié au connecteur vert de liaison à la
terre. Connecter les 2 conducteurs d’alimentation restants aux 2 bornes
restantes. Bien serrer chaque organe de connexion du branchement électrique.
Le non-respect de cette instruction peut causer un décès, un incendie ou un
choc électrique.
Pour le raccordement direct : Le câble à raccordement direct doit correspondre
à l’alimentation électrique (4 fils ou 3 fils) et être : La capacité du câble
doit être de 60 A minimum. Un câble en cuivre à gaine non métallique ou blindé
souple
(avec fil de liaison à la terre), avec conduit métallique souple. Tous les
fils sous tension doivent être isolés. Conducteur en cuivre de calibre minimal
6 (ne pas utiliser d’aluminium). D’au moins 5 pi (1,52 m) de long.
43
EXIGENCES CONCERNANT L’ÉVACUATION DE LA SÉCHEUSE
REMARQUE : Lors de l’utilisation d’un système d’évacuation existant, nettoyer
et éliminer la charpie sur toute la longueur du système, et veiller à ce que
le clapet d’évacuation ne soit pas obstrué par de la charpie. Remplacer tout
conduit de plastique ou en aluminium par un conduit métallique rigide ou
souple. Consulter à nouveau le “Tableau des systèmes d’évacuation” et modifier
le système d’évacuation existant au besoin pour obtenir un meilleur séchage.
AVERTISSEMENT : Pour réduire le risque d’incendie, cette sécheuse doit ÉVACUER
L’AIR À L’EXTÉRIEUR. IMPORTANT : Observer les dispositions de tous les codes
et règlements en vigueur.
Le conduit d’évacuation de la sécheuse ne doit pas être raccordé à une
évacuation de gaz, une cheminée, un mur, un plafond, un grenier, un vide
sanitaire ou un vide de construction. Seul un conduit d’évacuation métallique
rigide ou souple doit être utilisé pour le système d’évacuation.
4″ (102 mm)
Conduit d’évacuation en métal lourd de 4″ (102 mm)
Utiliser uniquement un conduit d’évacuation en métal lourd de 4″ (102 mm) et
des brides de serrage.
Ne pas utiliser de conduit de plastique ou de métal très mince. Conduit
métallique rigide : Recommandé pour une performance de séchage idéale afin
d’éviter tout écrasement ou déformation. Conduit métallique flexible :
(Acceptable uniquement si son accès reste facile pour le nettoyage) Doit être
entièrement déployé et soutenu à l’emplacement
d’installation final de la sécheuse. Enlever tout excès de conduit flexible
pour éviter tout
affaissement et déformation susceptible de réduire la capacité d’évacuation et
le rendement. Ne pas installer le conduit métallique flexible dans des cavités
fermées de mur, plafonds ou planchers. La longueur totale ne doit pas dépasser
73/4 pi (2,4 m).
Coudes : Les coudes à 45° permettent une meilleure circulation de l’air
que les coudes à 90°.
Bon
Mieux
Brides de serrage : Utiliser des brides pour sceller tous les joints.
Le conduit d’évacuation ne doit pas être raccordé ou fixé avec des vis ou tout
autre dispositif de serrage qui se prolongerait à l’intérieur du conduit et
retiendrait la charpie. Ne pas utiliser de ruban adhésif pour conduit.
44
EXIGENCES CONCERNANT L’ÉVACUATION DE LA SÉCHEUSE
Hottes d’extraction Clapets d’évacuation Diamètre de 4″ (102 mm)
Le clapet de décharge doit se trouver à au moins 12″ (305 mm) au-dessus du sol ou de tout autre objet susceptible de se trouver sur le trajet de l’air humide rejeté (par exemple, fleurs, roches, buissons ou neige).
Clapet de type boîte incliné
Clapet à persiennes
Clapet
Longueur du système d’évacuation
Longueur maximale du conduit/raccord La longueur maximale du système
d’évacuation dépend du type de conduit utilisé, du nombre de coudes et du type
de clapet d’évacuation.
Tableau des systèmes d’évacuation (conduit en métal rigide)
Nbre de changements direction à 90°
0
1
2
3
4
Clapet de type de boîte ou à
persiennes
130 pi (39,6 m)
125 pi (38,1 m)
115 pi (35,1 m)
106 pi (32,3 m)
98 pi (29,9 m)
Clapet incliné 129 pi (39,3 m) 119 pi (36,3 m) 109 pi (33,2 m) 100 pi (30,5 m)
92 pi (28 m)
Pour les systèmes d’évacuation autres que ceux indiqués dans le tableau des
systèmes d’évacuation, consulter le revendeur de pièces. Prévoir un espace
suffisant pour la combustion et la ventilation de l’air. (Vérifier les
dispositions des codes et règlements en vigueur). Voir “Instructions
d’installation dans un encastrement” dans les sections “Exigences de
l’emplacement”. Il est préférable d’utiliser une sortie de hotte de 4″ (102
mm). Cependant, on peut utiliser un clapet d’évacuation de 21 2″ (64 mm). Une
sortie de 21 2″ (64 mm) cause davantage de contre-pression que les autres
types d’installation. Pour une installation permanente, un système
d’évacuation fixe est requis. Raccordement du conduit d’évacuation 1. Si on
utilise le conduit d’évacuation existant, s’assurer qu’il est
propre. 2. À l’aide d’une bride de fixation de 4″ (102 mm), relier le conduit
d’évacuation à la bouche d’évacuation de laRascéccohredusdee. sortie
12″ mín. 12″ min. (305 mm) 3. Serrer la bride de serrage de tuyau avec un
tournevis Phillips.
4. S’assurer que le conduit d’évacuation est fixé au clapet d’évacuation à
l’aide d’une bride de fixation de 4″ (102 mm).
5. Placer la sécheuse à son emplacement final. Ne pas écraser
ni pincer le conduit d’évacuation. Vérifier que la sécheuse est d’aplomb.
REMARQUE : Ne pas enlever le raccord de sortie. 45
EXIGENCES CONCERNANT L’ÉVACUATION DE LA SÉCHEUSE
Si on ne peut pas utiliser de clapet d’évacuation L’extérieur du conduit d’évacuation principal doit comporter un conduit de déviation orienté vers le bas.
12″ min. (305 mm)*
24″ min. (610 mm)
- Distance de dégagement minimale au-dessus d’une accumulation de neige, de glace ou de débris tels des feuilles
Si le conduit principal monte verticalement à travers le toit et non à travers le mur, installer un coude de déviation à 180° à l’extrémité du conduit d’au moins 2 pi (610 mm) au-dessus de la surface ou du toit. Le diamètre de l’ouverture dans le toit ou le mur doit être supérieur de 1 2″ (13 mm) à celui du conduit. Le conduit doit être centré dans l’ouverture. Pour de meilleures performances, ne pas installer de grillage à l’extrémité de l’évacuation.
Évacuation pour plusieurs sécheuses On peut utiliser un conduit principal pour
assurer l’évacuation d’un ensemble de sécheuses. La taille du conduit
principal doit permettre une évacuation de 200 CFM d’air pour chaque sécheuse.
On peut utiliser des filtres à charpie haute capacité correctement conçus dans
le conduit principal s’ils sont inspectés et nettoyés régulièrement. La pièce
dans laquelle se trouvent les sécheuses doit comporter un système d’air
d’appoint au moins égal au CFM de toutes les sécheuses qui se trouvent dans la
pièce. Un ensemble clapet anti-retour, référence n°3391910, est disponible
auprès de votre distributeur et doit être installé sur la ligne d’évacuation
de chaque sécheuse pour éviter que l’air évacué revienne dans les sécheuses et
pour maintenir l’évacuation en équilibre avec le conduit de sortie principal.
Des ouvertures dégagées pour le retour d’air sont nécessaires. Chaque conduit
doit pénétrer dans le conduit principal en direction du mouvement de
circulation de l’air. Les évacuations par l’autre côté doivent être placées en
quinconce (décalées) pour réduire les interférences avec l’air sortant des
autres évacuations en face.
30° max. ADiérbfliot wd’air
L’inclinaison maximale de chaque conduit qui pénètre dans le conduit principal
ne doit pas dépasser 30°. Veiller à ce que les ouvertures de passage d’air
demeurent exemptes de vapeurs de solvants de nettoyage à sec. Les vapeurs sont
source de formation de composés acides, dont l’introduction via les modules de
chauffage de la sécheuse peut provoquer la détérioration de la sécheuse et du
linge en cours de séchage. L’ouverture principale comporte normalement un
couvercle amovible, ce qui permet le nettoyage périodique du circuit
d’extraction.
46
INSTALLATION DES PIEDS DE NIVELLEMENT
2. Vissage des pieds de nivellement
1. Préparer la sécheuse pour les pieds de nivellement (les pieds sont déjà
installés sur l’appareil).
REMARQUE : Faire glisser la sécheuse sur le carton ou le panneau dur avant de
la déplacer pour éviter d’endommager la surface du plancher.
À l’aide d’au moins deux personnes, déplacer la sécheuse à l’emplacement
d’installation souhaité.
Retirer le ruban des coins avant de la sécheuse. Ouvrir la sécheuse et ôter
les sachets de pièces et le document de référence. Essuyer l’intérieur du
tambour avec un chiffon humide pour éliminer toute trace de poussière.
Utiliser deux coins en carton de la boîte d’emballage de la sécheuse et les
placer sur le plancher, à l’arrière de la sécheuse. Saisir fermement le corps
de la sécheuse et l’allonger doucement sur sa partie postérieure sur les coins
de carton.
Examiner les pieds de nivellement pour trouver le repère en forme de diamant. Introduire manuellement les pieds dans les trous des pieds. Utiliser une clé à molette ou une clé de 1″ (25 mm) pour faire tourner les pieds jusqu’à ce que la marque de repérage (losange) ne soit plus visible. Placer ensuite un patin sur chaque pied.
Repère En Forme De Diamant
Pied
Pour protéger le plancher, utiliser un grand morceau de carton provenant de l’emballage de la sécheuse. Redresser la sécheuse sur le morceau de carton. Faire glisser la sécheuse jusqu’à ce qu’elle se trouve à proximité de son emplacement final. Laisser suffisamment d’espace pour pouvoir réaliser le raccordement électrique et du conduit d’évacuation.
47
NIVELLEMENT
Niveler votre sécheuse pour réduire de façon adéquate le niveau sonore et les
vibrations excessifs.
2. Saisir la sécheuse par le dessus et la faire basculer d’avant en arrière tout en s’assurant que les quatre pieds sont en contact ferme avec le sol. Faire de nouveau basculer la sécheuse transversalement. Si la sécheuse bascule, ajuster les pieds de nivellement.
1. Enlever le morceau de carton placé sous la sécheuse. Placer un niveau sur les bords supérieurs de la sécheuse en vérifiant chaque côté et l’avant. Si elle n’est pas d’aplomb, faire basculer la sécheuse et régler les pieds vers le haut ou vers le bas puis recommencer si nécessaire.
Pas d’aplomb
APLOMB
Pas d’aplomb
3. Si la sécheuse n’est pas d’aplomb, tourner les pieds de nivellement dans
le sens antihoraire pour abaisser la sécheuse ou dans le sens horaire pour la
soulever. Vérifier de nouveau l’aplomb de la sécheuse et s’assurer que les
quatre pieds touchent fermement le sol. Répéter si nécessaire.
CONSEIL UTILE : Il serait judicieux de soulever l’avant de la sécheuse
d’environ 102 mm (4″) à l’aide d’un bloc de bois ou un objet semblable qui
pourra soutenir le poids de l’appareil.
RACCORDEMENT À LA CANALISATION DE GAZ
Raccordement à la canalisation de gaz
AVERTISSEMENT
Risque d’explosion Utiliser une canalisation neuve d’arrivée de gaz approuvée
par CSA International. Installer un robinet d’arrêt. Bien serrer chaque organe
de connexion de la canalisation de gaz. En cas de connexion au gaz propane,
demander à une personne qualifiée de s’assurer que la pression de gaz ne
dépasse pas 330 mm (13 po) de la colonne d’eau. Par personne qualifiée, on
comprend : le personnel autorisé de chauffage, le personnel autorisé d’une
compagnie de gaz, et le personnel d’entretien autorisé. Le non-respect de ces
instructions peut causer un décès, un explosion ou un incendie.
2. Raccorder la canalisation de gaz à la sécheuse. Utiliser un composé
d’étanchéité compatible avec le gaz propane. Si un conduit métallique flexible
est utilisé, vérifier qu’il n’est pas déformé. Si nécessaire pour une
intervention d’entretien ou de réparation, ouvrir le panneau de plinthe.
Utiliser un couteau à mastic pour appuyer sur le verrou du panneau de plinthe
situé dans les coins supérieurs du panneau de plinthe. Tirer le panneau de
plinthe vers le bas pour l’ouvrir. Le panneau de plinthe est fixé à la partie
inférieure.
3. Ouvrir le robinet d’arrêt de la canalisation d’arrivée de gaz et vérifier
que la canalisation de gaz à la sécheuse est ouverte.
4. Vérifier tous les raccordements en les badigeonnant d’une solution de
détection des fuites non corrosive approuvée. L’apparition de bulles indique
une fuite. Réparer toute fuite éventuelle.
1. Retirer le capuchon rouge de la canalisation de gaz. 48
RACCORDEMENT À LA CANALISATION DE GAZ
Type de gaz Cette sécheuse est équipée pour une alimentation au gaz naturel.
Sa conception est homologuée par CSA International pour l’alimentation au gaz
de pétrole liquéfié (propane ou butane), avec conversion appropriée. Ne pas
entreprendre de convertir la sécheuse pour une utilisation avec un gaz
différent de celui indiqué
Canalisation d’alimentation en gaz Méthode recommandée Installer une
canalisation de gaz rigide de 1 2″ (13 mm) jusqu’à l’emplacement
d’installation de la sécheuse. On doit utiliser un composé d’étanchéité des
tuyauteries résistant à l’action du gaz de pétrole liquéfié. Ne pas utiliser
de ruban TEFLON®. Pour l’alimentation au propane, le diamètre des
canalisations ou tuyaux doit être de 1 2″ (13 mm) minimum. En général, le
fournisseur de gaz propane détermine les matériaux à utiliser et le diamètre
approprié pour le circuit.
sur la plaque signalétique sans consulter le fournisseur de gaz au préalable.
L’opération de conversion doit être exécutée par un technicien de réparation
qualifié. Les numéros de pièce de l’ensemble de conversion de gaz sont
indiqués sur la base des brûleurs.
Raccord métallique flexible pour appareil ménager : Il est recommandé
d’utiliser une canalisation en acier inoxydable souple neuve, conception
homologuée par CSA International, pour raccorder la sécheuse à la conduite
d’alimentation en gaz. (La canalisation d’arrivée de gaz émergeant au niveau
de la partie inférieure arrière de la sécheuse est dotée d’un filetage mâle de
3/8″).
Test de pressurisation de la canalisation de gaz Un piquage bouché de 1/8″ NPT minimum, accessible pour le contrôle de pression, doit être installé immédiatement en aval du robinet d’arrêt installé pour la sécheuse (comme illustré cidessous). Lors de toute épreuve de pressurisation du système à une pression supérieure à 1/2 lb/po2 (352 kg/m2), on doit déconnecter la sécheuse de la tuyauterie de l’alimentation en gaz. Méthode alternative L’alimentation en gaz peut aussi être raccordée à l’aide d’un conduit en cuivre ou en aluminium homologué de 38″ (10 mm). Si la longueur totale de la canalisation d’alimentation est supérieure à 20 pi (6,1 m), utiliser un conduit de taille supérieure. Pour le gaz naturel, ne pas utiliser de conduits en cuivre. On doit utiliser un composé d’étanchéité des tuyauteries résistant à l’action du gaz d’alimentation. Robinet d’arrêt nécessaire La canalisation d’alimentation doit comporter un robinet d’arrêt individuel manuel installé à 6 pi (1,8 m) maximum de la sécheuse conformément au National Fuel Gas Code, ANSI Z223.1. Le robinet doit se trouver dans la même pièce que la sécheuse. La canalisation doit se trouver en un endroit facilement accessible pour les manoeuvres d’ouverture/fermeture. Ne pas entraver l’accès au robinet d’arrêt manuel. Au Canada, un robinet d’arrêt individuel doit être installé conformément aux codes d’installation B149 CAN/CGA B149.1 et CAN/CGA B149.2.
REMARQUE : Ne pas déformer/endommager la canalisation en acier inoxydable flexible lors du déplacement de la porte. Raccordement par conduit rigide On doit utiliser un ensemble de raccords pour réaliser un raccordement rigide à la sécheuse.
®TEFLON est une marque déposée de E.I. Du Pont De Nemours et Compagnie.
49
RACCORDEMENTS ÉLECTRIQUES DE LA SÉCHEUSE ÉLECTRIQUE (É.-U. SEULEMENT)
Raccordement du cordon d’alimentation
AVERTISSEMENT
Retirer le couvercle du bornier
C
CB
D
B
Risque d’incendie
Utiliser un cordon d’alimentation électrique neuf homologué UL de 30 ampères.
Utiliser un réducteur de tension homologué UL.
Déconnecter la source de courant électrique avant de réaliser les connexions
électriques.
Connecter le conducteur neutre (blanc ou conducteur central) à la borne
centrale (argent).
Le conducteur de liaison à la terre (vert ou nu) doit être relié au connecteur
vert de liaison à la terre.
Connecter les 2 conducteurs d’alimentation restants aux 2 bornes restantes.
Bien serrer chaque organe de connexion du branchement électrique.
Le non-respect de cette instruction peut causer un décès, un incendie ou un
choc électrique.
Options de raccordement
Cordon d’alimentation
Prise murale à 4 fils (type NEMA 14-30R) Passer à la section “Raccordement de
la connexion à 4 fils : cordon d’alimentation”.
E E
A AD
Avant de commencer, débrancher l’alimentation. Retirer la vis de retenue (D)
et le couvercle du bornier (A).
A. Couvercle du bornier B. Vis du conducteur de terre externe C. Vis de la
borne centrale D. Vis de retenue E. Connecteur neutre de liaison à la terre
Serre-câble du cordon d’alimentation 1. Insérer le serre-câble. Retirer les
vis d’un serre-câble homologué UL de 3/4″ (19 mm). Placer les languettes des
deux moitiés de pince (C) dans le trou sous l’ouverture du bornier (B), de
sorte qu’une d’entre elles pointe vers le haut (A) et l’autre vers le bas (D).
Maintenir en place. Serrer les vis du serre-câble juste assez pour maintenir
ensemble les deux moitiés de pince (C).
Prise murale à 3 fils (type NEMA 10-30R) Passer à la section “Raccordement de la connexion à 3 fils : cordon d’alimentation”.
A
B C D
REMARQUE : Si les codes locaux n’autorisent pas le raccordement d’un conducteur de masse de la caisse au fil neutre, voir la section “Raccordement de la connexion à 3 fils : en option”. Ce raccordement peut servir pour un cordon d’alimentation ou une connexion directe des conducteurs. 50
RACCORDEMENTS DE LA SÉCHEUSE ÉLECTRIQUE
Raccordement du cordon d’alimentation (suite) 2. Insérer le cordon
d’alimentation dans le serre-câble. Passer le cordon d’alimentation à travers
le serre-câble. Vérifier que la gaine d’isolement du cordon d’alimentation
rentre à l’intérieur du serre-câble. Le serre-câble doit être bien relié à la
caisse de la sécheuse et se trouver en position horizontale. Ne pas visser
davantage les vis du serre-câble à ce stade.
Raccordement de la connexion à 4 fils : cordon d’alimentation
IMPORTANT : Un raccordement à 4 fils est obligatoire lorsque les codes locaux n’autorisent pas l’utilisation de raccordements à 3 fils. Connecteurs standard pour cordon d’alimentation
Connecter le conducteur de terre du cordon d’alimentation 3. Connecter le
conducteur de mise à la terre (vert ou nu) (E) à la
vis du connecteur de mise à la terre externe (C). Serrer la vis.
Connecteur à fourche et pointes relevées
Connecteur rond
Raccordement du conducteur de mise à la terre et du conducteur neutre
1. Retirer la vis (A) de la borne centrale du bornier et le conducteur
E
de terre neutre (B) en retirant la vis (C) du connecteur de terre
C
externe.
Connecter les conducteurs restants
B
A
4. Connecter les conducteurs restants au moyen des vis les plus à
l’extérieur du bornier (F). Resserrer les vis. Enfin, réinstaller le
couvercle du bornier et serrer la vis de retenue. Passer à la
section “Achever l’installation”.
C
2. Connecter le conducteur terre neutre (B) et le conducteur neutre (blanc ou central) à la borne centrale du bornier. Serrer la vis. D B
F
F
Raccordement de la connexion à 3 fils : cordon d’alimentation
Connecteurs standard pour cordon d’alimentation
Raccordement du conducteur neutre 1. Desserrer ou retirer la vis de la borne centrale du bornier (A).
Connecteur à fourche et pointes relevées
Connecteur rond
A
51
RACCORDEMENTS DE LA SÉCHEUSE ÉLECTRIQUE
Raccordement de la connexion à 3 fils : Cordon d’alimentation (suite)
2. Connecter le conducteur neutre blanc (blanc ou conducteur central) (D) à la borne centrale (argent). Serrer la vis.
3. Connecter les conducteurs restants au moyen des vis les plus à l’extérieur du bornier (F) Resserrer les vis. Enfin, réinstaller le couvercle du bornier et serrer la vis de retenue. Passer à la section “Achever l’installation”.
D
F F
RACCORDEMENTS ÉLECTRIQUES DE LA SÉCHEUSE ÉLECTRIQUE (É.-U. SEULEMENT)
Méthode de raccordement direct
AVERTISSEMENT
Direct 3 fils Passer à la section “Raccordement de la connexion à 3 fils : câblage direct”.
Risque d’incendie
Utiliser du fil en cuivre solide de calibre 10.
Utiliser un réducteur de tension homologué UL.
Déconnecter la source de courant électrique avant de réaliser les connexions
électriques.
Connecter le conducteur neutre (blanc ou conducteur central) à la borne
centrale.
Le conducteur de liaison à la terre (vert ou nu) doit être relié au connecteur
vert de liaison à la terre.
Connecter les 2 conducteurs d’alimentation restants aux 2 bornes restantes.
Bien serrer chaque organe de connexion du branchement électrique.
Le non-respect de cette instruction peut causer un décès, un incendie ou un
choc électrique.
Options de raccordement
Câblage direct Direct 4 fils Passer à la section “Raccordement de la
connexion à 4 fils : câblage direct”.
(251″mm)
REMARQUE : Si les codes locaux n’autorisent pas le raccordement d’un conducteur de masse de la caisse au fil neutre, voir la section “Raccordement de la connexion à 3 fils : en option”. Ce raccordement peut servir pour un cordon d’alimentation ou une connexion directe des conducteurs.
(127
5″ mm)
52
RACCORDEMENTS ÉLECTRIQUES DE LA SÉCHEUSE ÉLECTRIQUE (É.-U. SEULEMENT)
Retirer le couvercle du bornier
E E
A AD
2. Insérer le conduit dans le serre-câble et serrer la bride. Passer le câble à raccordement direct à travers le serre-câble. Le serre-câble doit être bien relié à la caisse de la sécheuse et se trouver en position horizontale. Serrer la vis du serre-câble autour du câble à raccordement direct.
Avant de commencer, débrancher l’alimentation. Retirer la vis de retenue (D)
et le couvercle du bornier (A).
A. Couvercle du bornier B. Vis du conducteur de terre externe C. Vis de la
borne centrale D. Vis de retenue E. Connecteur neutre de liaison à la terre
Serre-câble pour câblage direct 1. Insérer le serre-câble. Dévisser le raccord
de conduit amovible (A) et les vis d’un serrecâble homologué UL de 3/4″ (19
mm). Mettre la section filetée du serre-câble (C) dans le trou dessous
l’ouverture du bornier (B), visser le raccord de conduit amovible (A) sur le
filetage du serrecâble.
A B
C
53
RACCORDEMENTS DE LA SÉCHEUSE ÉLECTRIQUE
Raccordement de la connexion à 4 fils : câblage direct
IMPORTANT : Un raccordement à 4 fils est obligatoire lorsque les codes locaux
n’autorisent pas l’utilisation de raccordements à 3 fils. Le câble à
raccordement direct doit avoir une longueur supplémentaire de 5 pi (1,52 m)
pour pouvoir déplacer la sécheuse si nécessaire. Dénuder une longueur de 5″
(127 mm) de gaine extérieure à l’extrémité du câble, en laissant le conducteur
de mise à la terre nu à la longueur de 5″ (127 mm). Couper 11/2″ (38 mm) des
trois conducteurs restants. Dénuder les conducteurs sur une longueur de 1″ (25
mm). Former des crochets aux extrémités des conducteurs. Raccordement du
conducteur de terre neutre et du conducteur neutre
1. Retirer la vis (A) de la borne centrale du bornier et le conducteur de
terre neutre (B) en retirant la vis (C) du connecteur de terre externe.
Raccordement direct du conducteur de terre 3. Connecter le conducteur de mise
à la terre (vert ou nu) (E) à la
vis du connecteur de mise à la terre externe (C). Serrer la vis.
E
C
Connecter les conducteurs restants 4. Placer les extrémités en crochet des
conducteurs à
raccordement direct (crochets orientés vers la droite). Rapprocher les
extrémités en crochet et serrer les vis. Enfin, réinstaller le couvercle du
bornier et serrer la vis de retenue. Resserrer les vis. Passer à la section
“Achever l’installation”.
A
r B C
2. Connecter le conducteur de terre neutre (B) et placer l’extrémité en
crochet (crochet orienté vers la droite) du conducteur neutre (blanc ou
conducteur central) sous la vis de la borne centrale (B). Rapprocher les
extrémités du crochet. Serrer la vis.
D B
54
RACCORDEMENTS DE LA SÉCHEUSE ÉLECTRIQUE
Raccordement de la connexion à 3 fils : câblage direct
À utiliser lorsque les codes locaux autorisent la connexion du conducteur de
masse de la caisse au conducteur neutre. Le câble à raccordement direct doit
avoir une longueur supplémentaire de 5 pi (1,52 m) pour pouvoir déplacer la
sécheuse si nécessaire. Dénuder une longueur de 31/2″ (89 mm) de gaine
extérieure à l’extrémité du câble. Dénuder les conducteurs sur une longueur de
1″ (25 mm). En cas d’utilisation d’un câble à 3 fils avec conducteur de mise à
la terre, couper le fil nu au même niveau que la gaine extérieure. Former des
crochets aux extrémités des conducteurs. Raccordement du conducteur neutre 1.
Desserrer ou retirer la vis de la borne centrale du bornier (A).
A
B D
3. Placer les extrémités en crochet des conducteurs à raccordement direct
(crochets orientés vers la droite). Rapprocher les extrémités en crochet et
serrer les vis. Enfin, réinstaller le couvercle du bornier et serrer la vis de
retenue. Resserrer les vis. Passer à la section “Achever l’installation”.
2. Placer l’extrémité en crochet (crochet orienté vers la droite) du
conducteur neutre (blanc ou conducteur central) (D) sous la vis de la borne
centrale (B). Rapprocher les extrémités du crochet. Serrer la vis.
Raccordement de la connexion à 3 fils : en option
À utiliser pour le raccordement direct ou le cordon d’alimentation si les codes locaux ne permettent pas le raccordement du conducteur de terre de la caisse au neutre.
3. Connecter les conducteurs restants sous le bornier extérieur. Resserrer les vis.
Raccordement du conducteur neutre 1. Retirer la vis de la borne centrale (A).
Retirer également le
conducteur de terre neutre (B) en retirant la vis du conducteur de mise à la
terre externe (C).
A B
C 2. Connecter le conducteur de terre neutre (B) et le conducteur
neutre (blanc ou central) (D) du cordon/câble d’alimentation sous la borne
centrale du bornier. Serrer la vis.
D B
4. Raccorder un autre conducteur de terre en cuivre (G) sous la vis de
conducteur de terre externe (A) pour mise à la terre adéquate. Enfin,
réinstaller le couvercle du bornier et serrer la vis de retenue. Passer à la
section “Achever l’installation”.
C G
55
FIN DE L’INSTALLATION
1. Consulter les spécifications électriques. Vérifier que la tension
électrique disponible est correcte et que la prise de courant est
convenablement reliée à la terre. Consulter les “Spécifications électriques”.
2. Vérifier que toutes les pièces sont maintenant installées. S’il reste une
pièce, passer en revue les différentes étapes.
3. Vérifier la présence de tous les outils.
4. Éliminer/recycler tous les matériaux d’emballage. 5. Brancher sur une
prise reliée à la terre ou connecter la source
de courant électrique.
6. Vérifier le bon fonctionnement de la sécheuse. Fermer la porte de la
sécheuse. Sélectionner un programme. Choisir un programme de séchage complet
(pas le programme de séchage sans chaleur) et laisser la sécheuse fonctionner
pendant au moins cinq minutes. La sécheuse s’arrête une fois la durée écoulée.
REMARQUE : La porte de la sécheuse doit être fermée pour que celle-ci puisse
fonctionner. Si l’on ouvre la porte, la sécheuse s’arrête, mais la minuterie
continue à fonctionner. Pour remettre la sécheuse en marche, fermer la porte
et sélectionner le programme à nouveau.
7. Ouvrir la porte de la sécheuse. Vérifier que l’intérieur de la sécheuse
est chaud. Si le brûleur ne s’allume pas et qu’on ne ressent pas de chaleur à
l’intérieur de la sécheuse, éteindre la sécheuse pendant cinq minutes.
Vérifier que toutes les manettes des vannes d’alimentation sont en position
ouverte “on” et que le cordon électrique est branché.
8. Si le temps de séchage est trop long, s’assurer que le filtre à charpie
est propre et qu’il n’y a pas d’obstruction dans le système d’évacuation de
l’air.
9. Démarrer à nouveau la sécheuse et la laisser terminer un programme avec
chaleur (pas un programme de séchage à l’air) pour s’assurer qu’elle
fonctionne correctement.
56
INVERSION DU SENS D’OUVERTURE DE LA PORTE (FACULTATIF)
Le sens d’ouverture de la porte peut être changé du côté droit au côté gauche,
si désiré.
Retirer l’assemblée de porte 1. Placer une serviette sur le dessus de la zone
de travail pour
protéger la surface. 2. Ouvrir la porte de la sécheuse. Ôter les vis
inférieures
du côté charnière de la caisse. Desserrer (ne pas retirer) les vis supérieures
du côté charnière de la caisse.
Bouchons d’obturation
Loquet
7. Veiller à maintenir la cale d’espacement en carton centrée entre les portes. Fixer à nouveau le panneau de porte à la porte interne de façon à ce que la poignée se trouve du côté où les vis viennent d’être retirées.
8. Fixer à nouveau les vis de chaque côté de la porte (5 vis). Charnières
3. Soulever la porte jusqu’à ce que les vis supérieures de la caisse se
trouvent dans la partie large de l’encoche de la charnière. Tirer la porte
vers l’avant pour la dégager des vis. Placer la porte (côté poignée vers le
haut) sur la serviette. Retirer les vis de la charnière supérieure de la
caisse.
4. Retirer les vis fixant les charnières à la porte. 5. Retirer les vis de
chaque côté de la porte (5 vis).
9. Fixer les charnières de porte à la porte de la sécheuse de façon à ce que le trou le plus gros se trouve au fond de la charnière et que l’axe de la charnière soit orienté vers l’avant de la porte.
6. Tout en maintenant la porte sur une serviette, saisir les côtés de la porte externe et soulever doucement pour la séparer de la porte interne (ne pas les séparer en forçant). Ne pas tirer sur le joint ou le loquet en plastique de la porte.
10. Ôter les 4 vis fixant les 2 bouchons d’obturation du côté de la poignée.
Fixer les bouchons d’obturation au côté opposé à l’aide des mêmes 4 vis.
11. Insérer les vis dans les trous inférieurs du côté gauche de la caisse.
Serrer les vis à moitié. Positionner la porte de façon à ce que le côté large
de l’encoche de la charnière de porte se trouve au-dessus des vis. Faire
glisser la porte vers le haut de façon à ce que les vis se trouvent au fond
des encoches. Resserrer les vis. Insérer les vis supérieures dans les
charnières et serrer.
12. Fermer la porte et vérifier que la gâche de la porte est alignée avec le loquet. Au besoin, faire glisser le piton de retenue de la porte vers la gauche ou vers la droite à l’intérieur de l’encoche pour régler l’alignement. 57
INSTRUCTIONS D’ENTRETIEN
Nettoyer le filtre à charpie avant ou après chaque programme. Comment enlever
la charpie accumulée :
À l’intérieur de la caisse de la sécheuse : Il faut retirer la charpie
accumulée dans le conduit d’évacuation tous les 2 ans ou plus souvent, selon
l’utilisation de la sécheuse. Le nettoyage doit être effectué par une personne
qualifiée. De l’intérieur du conduit d’évacuation : Retirer la charpie tous
les 2 ans, ou plus souvent, selon l’utilisation de la sécheuse. Dégager
l’espace autour de la sécheuse; aucune matière combustible, essence ou autres
vapeurs ou liquides inflammables ne doit s’y trouver. Dégager l’emplacement de
la sécheuse de façon à ce qu’il soit libre de tout élément susceptible
d’obstruer le débit d’air de combustion et de ventilation.
Si la sécheuse ne fonctionne pas, contrôler ce qui suit : La prise de courant
est correctement alimentée. Le disjoncteur ne s’est pas déclenché et aucun
fusible n’est
grillé. La porte est fermée. Les boutons de commande sélectionnent une
configuration
de fonctionnement. Un programme a été sélectionné. Pour une sécheuse à gaz,
vérifier que les robinets
de la canalisation de gaz sont ouverts.
SI VOUS AVEZ BESOIN D’ASSISTANCE
Contacter le revendeur autorisé d’appareils de buanderie à usage commercial.
Pour localiser votre revendeur autorisé d’appareils de buanderie à usage
commercial ou pour toute question via internet, consulter
www.MaytagCommercialLaundry.com. Si vous ne parvenez pas à localiser un
revendeur, le centre d’aide pour les appareils de buanderie à usage commercial
répond à toute question qui n’aurait pas été abordée dans les “Instructions
d’installation” au sujet du fonctionnement ou de l’entretien de la sécheuse.
Il suffit de composer le 1-800 NO BELTS
(1-800-662-3587) l’appel est gratuit.
Lors de votre appel, vous aurez besoin du numéro de modèle et de série de la
sécheuse. Ces deux numéros figurent sur la plaque signalétique située dans
l’encadrement de la porte de la sécheuse.
INSTRUCTIONS DE RÉGLAGE DU TABLEAU DE COMMANDE ÉLECTRONIQUE
IMPORTANT Circuits électroniques sensibles
aux décharges électrostatiques
Le risque de décharge électrostatique est permanent. Une décharge
électrostatique peut détruire ou détériorer les circuits électroniques de la
sécheuse. La nouvelle carte peut sembler fonctionner correctement après la
réparation, mais une décharge électrostatique peut lui avoir fait subir des
contraintes qui provoqueront une défaillance plus tard. Utiliser un bracelet
de décharge électrostatique. Connecter
le bracelet de décharge électrostatique au point de connexion vert relié à la
terre ou sur une partie de métal non peint à l’intérieur de l’appareil.
-OUToucher plusieurs fois de suite avec le doigt un point vert de raccordement à la terre ou une surface métallique non peinte à l’intérieur de l’appareil. Avant de retirer la pièce de son emballage, placer le sachet
antistatique en contact avec un point vert de raccordement à la terre ou une
surface métallique non peinte à l’intérieur de l’appareil. Éviter de toucher
les composants électroniques ou les broches de contact ; manipuler les
circuits électroniques de la machine uniquement par les bords. Lors du
réemballage des circuits électroniques de la sécheuse défaillante dans le
sachet antistatique, observer les instructions ci-dessus.
58
Informations générales d’utilisation
SITUER LA CLÉ La clé est rangée avec les documents et les patins dans le
tambour. NE PAS PERDRE cette clé La clé est utilisée pour accéder au mode
d’entretien et permettre de régler la machine en vue de son utilisation. Les
machines sont déjà configurées à l’usine : MODÈLE PD (chute de pièces et
fonctionnement gratuit, voir la remarque) : Ces modèles sont configurés par
défaut à l’usine pour lancer un programme de séchage de 30 minutes au coût de
1,50 $ par programme. Le mode 6 est par défaut à 06. Le mode 7 est par défaut
à 05. Le tarif et la durée sont à la base configurés à l’aide des modes 6 et
7. Le mode 6 règle le nombre de pièces de 0,25 $ (p. ex., par défaut = 6 =
1,50 $) et le mode 7 règle la durée du programme par pièce de 0,25 $. Le
chiffre du mode 7 est multiplié par celui du mode 6 (durée maximum de 75
minutes). Le mode 7 est réglé par défaut à 5 à l’usine. (6 X 5 = 30 minutes
par défaut par programme) Remarque : Si on place le mode 6 sur 00, la machine
fonctionnera gratuitement et le temps de programme le perçoit comme un 1.
Alors, si le mode 6 = 00 et le mode 7 = 45, la durée du programme sera de 45
minutes et ne coûtera rien. MODEL PR/PN (gratuit ou prêt pour un lecteur de
paiement) Ces modèles ont par défaut mode 6 = 00 et mode 7 = 45. Il s’agit de
machines à fonctionnement gratuit de 45 minutes, voir les explications dans la
section PD.
INSTRUCTIONS DE RÉGLAGE DU TABLEAU DE COMMANDE ÉLECTRONIQUE
La clé est située dans le tambour
Informations générales d’utilisation AFFICHAGE VIDE Cette situation indique
que la sécheuse ne fonctionne pas. Entrer au mode de réglage pour consulter le
code de diagnostic. “0 MINUTES” INDIQUÉ SUR L’AFFICHAGE Cette mention
indique que le programme est terminé et que la sécheuse ne peut pas être
remise en marche. Les pièces introduites ou le débit par carte engagé pendant
cette phase sont stockées en avoir, mais ne sont pas utilisables tant que le
fonctionnement normal n’est pas rétabli par l’ouverture et la fermeture de la
porte. En cas de défaillance du contacteur d’une porte, le contacteur doit
être remplacé avant le rétablissement d’un fonctionnement normal. DÉMARRAGE À
FROID (première utilisation) La sécheuse est programmé en usine de la
manière suivante : Durée de séchage de 5 minutes/pièce de 25 cents (pièce 1).
Prix du séchage 1,50 $ (programme fixe avec durée supplémentaire ). DÉMARRAGE
À CHAUD (après coupure d’électricité) Quelques secondes après le
rétablissement de l’alimentation, si un programme était en cours au moment de
la coupure, “RESELECT CYCLE” (resélectionner programme) clignote sur
l’affichage, indiquant qu’il faut appuyer sur un bouton pour redémarrer la
sécheuse. TARIFS Une fois la porte ouverte, puis fermée après la fin de
programme, l’affichage indique le prix du programme (à moins d’un réglage pour
un fonctionnement gratuit). Après l’insertion de pièces ou un débit de la
carte de débit, l’affichage change pour guider l’utilisateur dans le lancement
d’un programme. Il existe quatre (4) types de tarif de la sécheuse : Tarif de
vente fixe Un paramétrage de la sécheuse pour un fonctionnement en programme
fixe peut accepter uniquement les durées supplémentaires accumulées par
paliers égaux à la durée d’un programme de séchage complet. Un maximum de 99
minutes peut être acheté ; aucun crédit supplémentaire n’est accordé pour les
pièces insérées lorsque 99 minutes est affiché.
Tarif par accumulation Si le prix est fixé à une pièce 1, le mode Accumulateur
est en vigueur (on doit également sélectionner Programme fixe avec l’option
Top Off (addition de temps)). Le temps d’utilisation peut être acheté à raison
d’une pièce à la fois jusqu’à un maximum de 99 minutes. Au mode tarification
Accumulateur tout l’argent introduit est porté au crédit d’un programme par
une unique pression sur un bouton. Programme fixe avec tarif d’appoint Une
sécheuse réglée pour proposer une fonctionnalité “Top Off” (appoint) permet
d’ajouter une durée à un programme de séchage existant par paliers égaux au
nombre de minutes de durée de séchage par pièce de 0,25 $ (pièce 1), jusqu’à
99 minutes, quel que soit le coût nécessaire pour mettre en marche la
sécheuse. Aucun crédit n’est accordé pour les pièces insérées ou les apports
par carte de débit lorsque l’affichage indique 99 minutes. L’incrément Centime
n’est pas appliqué pour les achats de temps ajouté. PROGRAMMES GRATUITS
Cette fonction est établie en réglant le prix du programme sur zéro. Dans ce
cas, “SELECT CYCLE” (sélectionner programme) s’affiche à la place du prix du
programme. Tout programme commencé comme programme gratuit prend fin
automatiquement lors de l’ouverture de la porte. COMPATIBLE CARTE DE DÉBIT
Cette sécheuse est compatible pour avec les lecteurs de carte de débit. Il
accepte divers systèmes de cartes de débit, mais est livré SANS lecteur de
carte de débit. Consulter le fabricant du lecteur de carte de débit pour une
installation correcte avec la sécheuse. Dans les modèles convertis en un
système à carte de débit de 1e génération, les impulsions de débit
représentent l’équivalent d’une pièce (pièce 1).
Affichage
Une fois la sécheuse branchée et sa porte ouverte puis fermée, l’affichage
indique le prix.
PRICE
1.50
PRICE
1.50
UPPER DRYER
WHITES & COLORS
HIGH HEAT
PERMANENT PRESS
MEDIUM HEAT
DELICATES LOW HEAT
WHITES & COLORS
HIGH HEAT
PERMANENT PRESS
MEDIUM HEAT
DELICATES LOW HEAT
LOWER DRYER
59
INSTRUCTIONS DE RÉGLAGE DU TABLEAU DE COMMANDE ÉLECTRONIQUE
Procédures de paramétrage des commandes
IMPORTANT : Lire toutes les instructions avant la mise en marche.
Les boutons de réglage du tissu, associés à l’affichage numériqu
References