Salamander Pumps CombiBoost Mains Booster Water Pump Installation Guide
- June 10, 2024
- Salamander Pumps
Table of Contents
- Salamander Pumps CombiBoost Mains Booster Water Pump
- Product Information
- Product Usage Instructions
- Pre-installation checklist
- Application notes
- Typical installations
- Commissioning
- General specifications
- Trouble shooting
- Fittings kit (not included)
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Salamander Pumps CombiBoost Mains Booster Water Pump
Product Information
Pump Installation and Warranty Guide for CombiBoost and HomeBoost
The Pump Installation and Warranty Guide for Combi Boost and HomeBoost is a document that should be given to the end user and retained for future reference. The guide provides information on the installation and warranty of the HomeBoost and CombiBoost pumps manufactured by Salamander Pumps.
The HomeBoost and CombiBoost pumps have two separate and distinct applications. The first is for use on the incoming domestic cold water mains supply, and the second is directly on the combi-boiler cold water inlet. HomeBoost is designed to boost your existing incoming mains water supply up to 12 litres per minute (lpm), while CombiBoost is designed to boost your existing incoming mains water supply up to 10 litres per minute (lpm).
The guide also includes a pre-installation checklist,application notes, typical installations, commissioning instructions, general specifications, lighting codes and troubleshooting, fittings kit, PumpWise and warranty information, terms and conditions, and instructions for installers.
Product Usage Instructions
Pump Installation and Warranty Guide for CombiBoost and HomeBoost
Before installing the HomeBoost or CombiBoost pump, follow the pre- installation checklist provided in the guide. The pre-installation checklist includes do’s and don’ts that apply to both whole house installation and combi-boiler installation. It is essential to read these instructions thoroughly and ensure that you comply with them. Incorrect fitting will invalidate the warranty.
The guide also includes application notes that provide instructions on the best possible location of the HomeBoost/CombiBoost pump. The pump should be placed in a position where there is adequate air flow to cool the motor and separated from any other appliances that generate heat. The HomeBoost/CombiBoost must also be protected from frost damage.
After installation, commission the pump according to the instructions provided in the guide. The intelligent control ensures that it reacts and responds to give a stable outflow, and is unrestrictive if your natural water flow reaches 12lpm or more naturally.
If you have any questions or if your installation is complicated, please consult the PumpWise Technical Helpline immediately (0191 516 2002).
Finally, complete the warranty registration on Salamander Pumps’ website or by calling 0191 516 2002. Please leave this installation guide with the customer for reference to maintenance and safety information.
This document should be given to the end user and retained for future
reference.
Should you need to contact Salamander Pumps you will need the below
information.
Pump installation and warranty guide for HomeBoost and CombiBoost
Important – read this first!
HomeBoost™ and CombiBoost have two separate and distinct applications. The
first is for use on the incoming domestic cold water mains supply, and the
second is directly on the combi-boiler cold water inlet.
HomeBoost™ is designed to boost your existing incoming mains water supply up
to 12 litres per min (lpm). The intelligent control ensures that it reacts and
responds to give a stable outflow, and is unrestrictive if your natural water
flow reaches 12lpm or more naturally.
CombiBoost is designed to boost your existing incoming mains water supply up
to 10 litres per min (lpm).
Correct installation is essential for safe operation and a trouble free
system. It is therefore important to read these instructions thoroughly and
ensure that you comply with them. Incorrect fitting will invalidate the
warranty.
If your installation is complicated or you have any questions, please consult
the PumpWise Technical Helpline immediately (0191 516 2002).
We encourage installers to consult the Salamander helpline before
installation, where our technical advisers can give you professional advice
regarding installation. When the job is finished, please complete the warranty
registration on our website
www.salamanderpumps.co.uk or by calling
0191 516 2002.
Please leave this installation guide with the customer for reference to
maintenance and safety information.
Thank you for choosing Salamander Pumps
Pre-installation checklist
HomeBoost™ and CombiBoost are suitable for two separate types of water boosting applications:
- Boosting the incoming mains water supply to a whole house
- Boosting the inlet mains water supply solely to a combination (combi) boiler. Points applicable to either installation type:
Do’s
- HomeBoost™/CombiBoost must be fitted to rigid fixed pipework preferably with vertical inlet and outlet
- Pipework above and below the pump must be securely fixed to the wall
- Only one HomeBoost™/CombiBoost may be fitted per household supply
- Ensure that installation complies with IET Wiring Regulations
- Allow 100mm on all sides for ventilation
- Ensure pump is protected from frost
- Complete all hot work fitting prior to HomeBoost™/CombiBoost installation
- We recommend that the pump is activated for at least five minutes every four weeks
- If the supply is known to be lime/calcium (hard) water, fit extra filtration before the pump. Always consult filter manufacturer’s literature for correct installation.
Don’ts
- Never fit to hot water piping
- Never fit the pump to communal risers
- Never pump directly from or to another pump
- Never fit to flexible pipework (e.g. tap connectors)
- HomeBoost™/CombiBoost cannot be used on outside coldwater storage tanks, bore holes or wells
- Never use jointing compounds,Boss White, hemp or steel wool
- Solder fluxes must not come into contact with the pump
- Never fit HomeBoost™ /CombiBoost upside down
Points applicable to whole house installation:
Do’s
- Install vertically or horizontally, mounted on cold water mains inlet to the house
- Locate the pump next to the mains stop tap
- Pump should be fitted before ANY other water outlets taken after the mains stop tap. If any outlets are between the stop tap and your HomeBoost™/CombiBoost, they must be fitted with a non-return valve
Points applicable to combi-boiler installation:
Do’s
- Install vertically or horizontally, mounted on cold water mains inlet to the combi boiler
- Locate the pump next to the combi-boiler OR on it’s cold water mains inlet
- Pump must exclusively feed the combi- boiler
Application notes
Please follow these pre-installation instructions carefully. Failure to install your HomeBoost™/CombiBoost in accordance with these instructions will invalidate your warranty.
-
Location of HomeBoost™/CombiBoost
The best possible location of the HomeBoost™/CombiBoost is on the cold water mains supply to the house, after the mains stop tap or on the combi boiler inlet, depending on the installation. -
Cooling and ventilation
The HomeBoost™/CombiBoost should be placed in a position where there is adequate air flow to cool the motor and separated from any other appliances that generate heat. -
Frost protection
HomeBoost™/CombiBoost must be protected from frost damage. -
Cold supply to the HomeBoost™/CombiBoost
HomeBoost™/CombiBoost must be fitted directly to the cold water mains house supply, or the mains water inlet to the combi boiler as indicated in the pre- installation checklist. Never fit to communal risers (e.g. block of flats). -
General plumbing
Please note that the HomeBoost™/CombiBoost is designed to boost incoming water flow under low pressure conditions.
Installation must comply with the relevant requirements or local byelaws.
It is recommended that HomeBoost™/CombiBoost is installed vertically, and every effort should be made to accommodate this. However, HomeBoost™/CombiBoost will function correctly if installed horizontally. It must be adequately vented, protected from frost, and with access provided for servicing.
Jointing compounds, Boss White, hemp and steel wool MUST NOT BE USED. SOLDER FLUXES MUST NOT COME INTO CONTACT WITH THE PUMP. THIS WILL INVALIDATE YOUR WARRANTY.
Supplied inlet strainer must be fitted to the inlet supply of the HomeBoost™/CombiBoost. All outlets which are located between the mains stop tap and the HomeBoost™/CombiBoost must be protected by non-return valves. This is to prevent backflow of water and air from these outlets to the HomeBoost™/CombiBoost, which will cause damage to the pump.
Suitable for maximum inlet pressure of 1MPa (10 bar).
In line with good plumbing practice and water regulations, ensure that a non- return valve has been fitted directly after the mains stop tap to the house. Earth continuity must be maintained. -
Isolation valves
Good plumbing practice is to fit full bore isolating valves into the inlet and outlet pipe work of the pump to facilitate service and removal of the pump. To install immediately after the stop tap, the isolation valve should be fitted to the pump outlet. To install to a combi boiler only, the isolating valve should be fitted to the pump inlet. -
Holding the HomeBoost™/CombiBoost during installation
To hold HomeBoost™/CombiBoost during installation, spanner flats (24mm) have been provided on the brass neck outlet. See Figure 1. Any tool used to hold HomeBoost™/CombiBoost while the pipework is connected must be located on the brass portion of the neck to avoid damage to the polymer pump body. -
Electrical requirements
HomeBoost™ /CombiBoost must be connected to the electrical supply using the mains cable with the attached plug. This plug must be connected to an accessible socket that has been installed in compliance with IET Wiring Regulations.
The plug must be accessible at all times.
If the supply cord is damaged, it must be replaced by the manufacturer, it’s service agent, or similarly qualified person in order to avoid a hazard.
All pipe work must be cross-bonded in accordance with the IET Regulations.
HomeBoost/CombiBoost™ is supplied with a 3A fuse fitted. Higher rated fuses MUST NOT be used.
If installed by a Part P qualified installer, the pump may be fitted via a 3A fused mains spur without invalidating the warranty.
Typical installations
Commissioning
Before you finish
- Check the pump inlet filter is fitted
- With HomeBoost™/CombiBoost installed, flush the inlet pipe work and fully fill the pump with water by opening all the water outlets BEFORE electrically switching the pump on.
It is critical to discharge water through the pump through;
- all the cold outlets on a whole house application. or
- all the hot outlets for a combi boiler boost application. Using natural flow before switching the pump on electrically. This will ensure that the air has been discharged from the connecting pipe work and pump chamber.
The best method is:
- Connect pump pipe work
- Check that all isolating valves are open
- Turn mains water on at the stop tap
- Ensure all air is purged from the system
- Check for natural flow on the cold outlets (or hot outlets for a combi boost installation)
- Inspect connecting pipe work for leaks
- Plug in electrical supply to pump
- Turn mains electrical supply on
- Green pump lights in the logo label should be lit and steady. This indicates that the power is on and that the pump is ready for use (HomeBoost™ only)
- Turn a pumped outlet on
- HomeBoost™/CombiBoost should activate. The green lights should rotate, indicating that the pump is in operation (HomeBoost™ only).
If the HomeBoost™/CombiBoost does not activate, please refer to the trouble shooting section of these application notes.
General specifications
Applications
HomeBoost™/CombiBoost pumps are designed to boost low mains water flow into a
domestic house to improve low water flow from the mains supply at peak demand
times. These pumps can be used in two distinct applications:
- Boosting the incoming mains water supply to a whole house
- Boosting the inlet mains water supply solely to a combination (combi) boiler.
HomeBoost™ will increase the low incoming water flow up to 12 lpm and CombiBoost will increase to 10 lpm which comply with the Water Supply (Water Fittings) Regulations 1999. HomeBoost™ will adapt to maintain 12 l/min, and will move into idle if sufficient flow is received from the water main.
Power supply
230 volts, 50Hz, 1.8A, continuously rated.
Pump noise
The HomeBoost™ pump has been awarded the quiet mark, demonstrating that it is
one of the quietest pumps available in its category. However, no pump is
completely silent and this type of pump is characterised by a high pitched hum
or whine.
Mechanical seals
Scale deposits in water supplies can cause the mechanical seal to stick if
left for long periods without use. We recommend that the pump be run for at
least five minutes every four weeks to ‘exercise’ all the working parts.
Connections
¾” BSP male.
Initiation
Fully automatic, water flow operated, requiring 3 litres per minute flow rate
to initiate.
Temperature
Maximum fluid temperature is UK cold water mains temperature (max 20°C).
Standards and approvals
- WRAS approved product
- Complies with the Water Supply (Water Fittings) Regulations 1999
- Splash proof rating IPX4
- Complies with European Community Directives (CE)
- Tested for sound power level in accordance with methods set out in BS EN ISO 3744:2010 and BS EN ISO 20361:2009, and results calculated to BS EN ISO 11203: 2009
- EN 55014-1:2006 Electromechanical compatibility (EMC) – Requirements household appliances, electrical goods and similar apparatus (Part 1)
- EN 60335-1:2002 and EN 60335-2-41:2003 Household and similar electrical appliances safety (Part 1 General requirements and Part 2-41 Particular requirements for pumps).
The company operates a policy of continuous development and reserves the right to change any of the specifications of its products without prior notice. All information data and illustrations given in this leaflet may be subject to variation.
Safety in operation
These appliances are not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should
be supervised to ensure that they do not play with the appliance.
WEE Directive
Your appliance contains valuable materials which could be recovered or
recycled. At the end of the product’s useful life please dispose of it at an
appropriate civil waste collection point.
WEEE Directive 2012/19/EU
At the end of the product life dispose of packaging and product in a
corresponding recycling centre.
Do not dispose of the unit with the usual domestic refuse. Do not burn the
product.
Lighting codes (HomeBoost™ only)
Lighting pattern | Denotes |
---|---|
On steady and dim | Power on |
Slow clockwise | Pump in normal running mode |
Fast clockwise | Pump in high speed running mode |
Single sideways flash | **Overheat (motor speed will be limited |
until temperature drops, or will cut off completely for safety in extreme
cases)
Flashing diagonally| Sufficient mains water flow
through pump without pump running**
Trouble shooting
Fault | Probable cause | Recommended solution |
---|---|---|
Pump will not start | Electrical | **Check power supply |
(appliance plugged in and electrical power on) Check fuse**
Check circuit breaker
Inlet/outlet connections| Check that the connections
are plumbed in the correct way round and
all valves are open
Insufficient mains flow| Check that the installation complies with the
Salamander instructions Check inlet filters are not blocked
Check stopcock and all isolating valves are fully open Check natural flow rate minimum of 3litres/min
Over temperature (single sideways light flashing)
(HomeBoost only)
| Leave pump turned off for ten minutes to cool down Then re-attempt
start up routine
Natural flow > 10lpm (CombiBoost)
Natural flow >12lpm
(HomeBoost)
| Diagonal flash, normal pump function (HomeBoost
only)
Pump starts and lights flash diagonally (HomeBoost™ only)| Sufficient
mains water flow| HomeBoost™ not required to run at this time. Pump
will only run during periods of low water flow
Reduced/ intermittent flow| Insufficient mains flow|
See above
Blocked inlet filter| Ensure that inlet filter
is free from debris
Air in system| Run system on full cold for a whole house install, or
full hot in a combi boiler install, with pump switched off (i.e. mains
water supply only) for several minutes
Pump starts with all outlets closed| Leak in system|
Check for leaks
Outlet open| Ensure all outlets are fully
closed or capped – i.e. no dead legs in
pipework
Pump is noisy| Air in system| See above
Pump vibrating against other pipework| Move pump
away from contact with other pipe work
Pump running hard| Check filters and unblock if
necessary
Pump is leaking| Pump has suffered chemical damage|
Ensure that pump has not come into contact with chemical substance i.e.
solder flux
Pump exposed to extreme temperature| Ensure
adequate frost protection
Pump appears to have leaked but not sure| Check
leak is not from fitting in pipe work above pump
Check condensation build up – drain holes in the base of the pump casing should allow excessive water to drain off
Fittings kit (not included)
Purchase separate – ACCHBFIT01 from https://shop.salamadnerpumps.co.uk/
Contents
Fitting instructions
Warranty
0191 516 2002
Monday to Thursday 8.00am to 5.30pm, Friday 8.00am to 5.00pm.
PumpWise is the cornerstone of Salamander’s support service to our customers
and the means by which our customers are guaranteed:
-
Selection of the right pump for the job
With more than 30 pumps in our range, the PumpWise team can help you to choose the pump that’s most suitable to your specific installation. -
The avoidance of installation pitfalls
Due to the technical nature of our products, it is essential that they are fitted according to our installation guidelines. The PumpWise team are available to talk through any installation questions and provide technical support and guidance. -
Warranty
- HomeBoost™ has a three year warranty. CombiBoost has a one year warranty.
Our PumpWise commitment
Our PumpWise helpline is here to help you and we aim to provide a support service second to none. Installers and consumers can be sure of a speedy response to requests for technical help, guidance, and advice.
- HomeBoost™ has a three year warranty. CombiBoost has a one year warranty.
Your warranty
HomeBoost™ comes with a three year warranty and CombiBoost comes with a one
year warranty.
This warranty will operate from the date of purchase and is subject to the
installation guidelines being followed correctly (please refer to our Pre-
Installation checklist and our Commissioning checklist).
Please complete the warranty registration on our website
www.salamanderpumps.co.uk or by calling
0191 516 2002.
For further details please contact the PumpWise team:
Telephone: 0191 516 2002
Fax: 0191 548 4445
Email: tech@salamanderpumps.co.uk
PLEASE NOTE: Incorrect installation will invalidate the pump warranty. Please
fully read the following terms and conditions.
To the installer
Please follow the guidelines for the installation provided in this brochure
and call the PumpWise helpline for installation advice. Once installation has
been completed and the system has been tested to your satisfaction, please
assist the customer by giving them the information needed to complete the
online warranty registration.
Please note that Salamander are able to provide an onsite service visit which
may be chargeable.
Terms, conditions and warranty
-
The Scope of the Warranty
SALAMANDER PUMPED SHOWER SYSTEMS LTD (“the company”) Warrants subject to the terms and conditions below for the Warranty period(s) specified in paragraph 3 that the Company shall:
Repair or replace free of charge the product(s) specified on the Warranty registration or any component part thereof (together referred to as “the equipment”) which shall in the opinion of the Company have proved defective by reason only of the Company’s materials or workmanship providing always that the Company shall be under no obligation whatsoever under this Warranty to repair or replace equipment which shall have been misused modified altered or transformed in any way without the consent in writing of the Company or if any component or accessory shall have been replaced by a type not specified by the Company or if the equipment is incorrectly installed or operated or used other than as described in the instruction manual or if any servicing or repair of the equipment shall have been carried out otherwise than by an authorised Company dealer appointed by the Company (“dealer”).
The Company’s liability under this Warranty is limited to the said repairs or replacement and shall under no circumstances extend to any financial loss or damage including consequential losses alleged to have been suffered by the claimant.
Subject as provided in this warranty and except where the equipment is sold to a person dealing as a consumer all warranties, conditions or other terms implied by law are excluded to the fullest extent permitted by law.
Nothing in this warranty shall exclude liability for death or personal injury caused by the Company’s negligence. -
Terms and conditions
This Warranty shall only be enforceable by you if the following terms and conditions have been complied with:- That the pump has been installed in accordance with the installation instructions,guidance and advice contained within the installation and warranty guide and/or provided by the Salamander help desk.
- You are the original purchaser of the equipment from a dealer and not an assignee or subsequent purchaser of the equipment.
- You must evidence the date of purchase by retaining the original invoice from the dealer. Without such evidence the Company reserves the right to reject any such claims under the terms of this Warranty.
- Within 15 days of delivery of the equipment to you the Warranty is registered with the Company.
- Within thirty days of discovery of a defect giving rise to liability under paragraph 1 above you give notice thereof in writing to the Company.
-
The Warranty periods
The Warranty periods referred to in paragraph 1 above are as follows:-
HomeBoost product manufactured by the Company three years from date of purchase and CombiBoost product manufactured by the Company one year from date of purchase provided the warranty is registered with the Company within 15 days of purchase.
-
Products supplied by the Company, but not of the Company’s manufacture – one year from date of purchase.
-
The warranty period in respect of any product repaired or replaced under the warranty shall be part of the above period(s) which
-
In the event of a claim for repairs or replacement being made under the terms of this Warranty in the circumstances where in the opinion of the Company the defect has not been caused by the Company’s materials or workmanship then the Company reserves the right to charge the claimant at its current hourly rates and list prices in respect of any service engineer’s time and any replacement of parts.
-
This Warranty is given in addition to and does not affect your statutory rights as a consumer.
f This Warranty is valid and enforceable for equipment purchased and used exclusively in the UK and The Republic of Ireland only. -
Where the Company makes a replacement the equipment replaced shall be returned to the Company forthwith and shall become the property of the Company.
-
No authority has been given to any person, firm or company to vary the terms of this Warranty.
-
Get in touch,
we’re here to help
call us on
0191 516 2002
Unit 2c Colima Avenue
Enterprise Park West
Sunderland, SR5 3XE
Register your warranty
Apply online at:
www.salamanderpumps.co.uk
Apply by phone:
0191 516 2002
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>