FAS ELECTRONICS FNI IOL-716-000-K023 Signal Converters User Guide

June 10, 2024
FAS ELECTRONICS

FAS-logo

FAS ELECTRONICS FNI IOL-716-000-K023 Signal Converters

FNI IOL-716-000-K023

Notes

Struture of the guide

The guide is organized so that the sections build on one another. Section 2: Basic safety information.

Typographical conventions
The following typographical conventions are used in this guide.

Enumertions
Enumertions are shown in list form with bullet points:

  • Entry 1
  • Entry 2

Action
Action instructions are indicated by a preceding triangle. The result of an action is indicated by an arrow.

  • Action instruction 1
  • Action instruction 2
  • Action instruction 2

Syntax

Numbers:
Decimal numbers are shown without additional indicators (e.g. 123), Hexadecimal numbers are shown with the additional indicator hex (e.g. 00hex).

Cross references
Cross references indicate where additional information on the topic can be found.

Symbols

Note
This symbol indicates general notes.

Attention!
This symbol indicates a security notice which most be observed.

Abbreviations

  • FNI FAS Network Interface FAS
  • O-Port Standard output port
  • DPP Direct parameter page
  • IOL IO-Link
  • EMC Electromagnetic compatibility
  • FE Function ground
  • SPDU Service Protocol Data Unit

Deviating views
Product views and illustrations in this user’s guide may differ from the actual product. They are intended only as illustrative material.

Safety

Intended use
This guide describes the FAS Network Interface FNI IOL-716-000-K023 for the application as peripheral output module to connect analogue sensors. Hereby it is about an IO-Link device which communicates by means of IO-Link protocol with the superordinate IO- Link master assembly.

Installation and startup

Attention!
Installation and startup are to be performed only by trained specialists. Qualified personnel are persons who are familiar with the installation and operation of the product, and who fulfills the qualifications required for this activity. Any damage resulting from unauthorized manipulation or improper use voids the manufacturer’s guarantee and warranty. The Operator is responsible for ensuring that applicable of safety and accident prevention regulations are complied with.

General safety notes

Commissioning and inspection
Before commissioning, carefully read the operating manual. The system must not be used in applications in which the safety of persons is dependent o the function of the device.

Authorized Personnel
Installation and commissioning may only be performed by trained specialist personnel.

Intended use
Warranty and liability claims against the manufacturer are rendered void by:

  • Unauthorized tampering
  • Improper use
  • Use, installation or handling contrary to the instructions provided in this operating manual

Obligations of the Operating Company
The device is a piece of equipment from EMC Class A. Such equipment may generate RF noise. The operator must take appropriate precautionary measures. The device may only used with an approved power supply. Only approved cables may be used.

Malfunctions
In the event of defects and device malfunctions that cannot be rectified, the device must b taken out of operation and protected against unauthorized use. Intended use is ensured only when the housing is fully installed.

Resistance to aggressive substances

Attention
The FNI modules generally have a good chemical and oil resistance. When used in aggressive media (eg chemicals, oils, lubricants and coolants each in
high concentration (ie, low water content)) must be checked prior application- related material compatibility. In the event of failure or damage to the FNI modules due to such aggressive media are no claims for defects. FNI

FAS Network Interface / IO-Link

Hazardous voltage

Attention!
Disconnect all power before servicing equipment.

Note
In the interest of product improvement, the FAS reserves the right to change the specifications of the product and the contents of this manual at any
time without notice.

Getting started

Connection overview

  1. Status LED: Supply, Communication
  2. Label
  3. IO-Link interface IO-Link
  4.  Analogue output port

Mechanical connection
To avoid long, shielded analogue cables, the FNI IOL-716-000-K023 modules should be attached to the analogue unit which has to be connected. No further mechanical attachment is required.

Electrical connection
The FNI IOL-716-000-K023 modules require no separate supply voltage connection. Power is provided through the IO-Link interface by the superordinate IO-Link Master Assembly. FNI IOL-716-000-K023.

IO-Link interface

IO-Link (M12, A-coded, male)

  1. Pin : Signal
  2. Supply voltage, +24V-
  3. GND, reference potential GND
  4. C/Q, IO-Link Data transmission channel C/Q, IO-Link

Connecting the module

Connect the FNI IOL-…-K023 either to an IO-Link Master directly or to an analogue sensor.

Note
A standard 3 wire sensor cable is used for connection to the host IO-Link master.

Note
A shielded 4 wire sensor cable is used for connection to the analog actuator.

Module versions

Module versions Analogue port
FNI IOL-716-000-K023 PT100 input

Sensor interface
Analogue input port (M12, A-coded, female)

IO-Link interface

Data transmission rate COM2 (38,4 kBaud)
Frame type 2.V
Minimal cycle time 3 ms
Prozess data length 2 Byte input

Process data / input dataoutput data

Input data

Byte0 Byte1
7 6

MSB

| PT100 input value (only in case of FNI IOL-716-000-K023)|

LSB

|

Flag

Onput data

Byte0 Byte1
7 6

|

|

|

|

|

|

|

|

|

|

|

|

|

|

| –

Note
The flag: 0: Positive temperature

  • Negative temperature
  • eg: The value is 0x1795, so the temperature is -30.18℃
  • The value is 0x2710, so the temperature is 100℃

Technical data

Dimensions

FAS-ELECTRONICS-FNI-IOL-716-000-K023-Signal-
Converters-05

Figure 5-1: Dimensions FNI IOL-…-K023

Mechanical data

Housing materials Plastic, Macromelt 6208
IO-Link port M12, A-coded, male
I-port M12, A-coded, female
Enclosure rating per IEC 60529 IP 67 (only when plugged in and threaded in)
Dimensions (W x H x D in mm) 40 x 50.4 x 14.2
Weight ca. 50 g

Electrical data

Operating voltage 18. 30.2 V DC, per EN 61131-2
Ripple < 1%
Current draw without load <= 30 mA
Resolution 15bit

Operating Conditions

Operating temperature -5 °C … 70 °C
Storage temperature -25 C … 70 °C

LED indicators

Status LED

LED| Indicator| Function

---|---|---
LED 1| Green / Green flashing

| Communication error / Communication ok

LED 2| Green| Supply sensor

Appendix

Product ordering codeFAS-ELECTRONICS-FNI-IOL-716-000-K023-Signal-
Converters-07

Scope of delivery

FNI IOL-…-K023 consists of the following components:

  • IO-Link module
  • User´s guide

www.fas-elec.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals