FAS ELECTRONICS FNI IOL-106-006-K20 IP20 Hub 32xDO NPN User Manual
- June 10, 2024
- FAS ELECTRONICS
Table of Contents
FAS ELECTRONICS FNI IOL-106-006-K20 IP20 Hub 32xDO NPN
Product Information
- The FNI IOL-106-006-K20 is a digital input/output module developed by Fuyansheng Electronics (Fujian) Co. LTD. It features an IO-Link interface, digital I/O terminal blocks, 24V terminal block, GND terminal, and status LEDs for digital I/O point 32, IO-Link, power, and actuator. The product also includes a pin illustration for power supply, actuator power supply, GND, and C/Q channel for IO-Link data transfer.
- The digital output points are numbered from 1 to 32, with a bit descriptions and addresses assigned based on the input starts address assigned in the configuration project. The product also has a data transmission baud rate of 384 kbit/s, a minimum cycle time of 2ms, and process data cycle time of 3ms.
- The product has an error code feature that includes device app errors, additional codes for index and subindex unavailable, and value out of range. It also has a hardware power supply feature for low voltage supply at +24V.
Product Usage Instructions
To use the FNI IOL-106-006-K20 digital input/output module:
- Connect the IO-Link interface, digital I/O terminal blocks, 24V terminal block, and GND terminal as shown in Figure 1.
- Refer to Pin Illustration in Figure 2 for power supply (+24V), actuator power supply (+24V), GND, and C/Q channel for IO-Link data transfer.
- Assign input start address in the configuration project to determine the numbering and bit description of the digital output points. The first point address is based on the assigned start address.
- Refer to Table 1-1 for data transmission baud rate, frame type, minimum cycle time, process data cycle time, and process data length.
- Use the error code feature to troubleshoot device app errors, index and subindex unavailable, and value out-of-range issues. See Figure 5 for additional codes and patterns.
- Refer to Figure 6 for the hardware power supply feature for low voltage supply at +24V.
Connection diagram
As shown in Figure 1.
- 10-Link interface
- Digital I/0 Terminal Blocks
- 24V terminal block
- ND terminal
- Status LED: Digital I/O point 32
- Status LEDs: I0-Link
- Status LED: Power
- Status LEDs: Actuator
I0-Link interface diagram
As shown in Figure 2.
Pin | Illustrate |
---|---|
1 | Power supply, +24V |
2 | Actuator power supply, +24V |
3 | GND |
4 | C/Q, IO-Link data transfer channel |
10-Link data
Parameter As shown in
Table 1-1. Surface 1-1
Process data length| Process data cycle time| Minimum cycle time| Frame type|
Data transmission baud rate
---|---|---|---|---
4 bytes output| 3ms, consistent with minimum cycle time| 3ms| 2 V| COM2 (38
4kbit/s)
Process data/input data
As shown in Figure 3.
Describe| Bit| | Describe| Bit|
---|---|---|---|---|---
Digital output point 24| 7| 2| Digital output point 8| 7| 0
Digital output point 23| 6| Digital output point 7| 6
Digital output point 22| 5| Digital output point 6| 5
Digital output point 21| 4| Digital output point 5| 4
Digital output point 20| 3| Digital output point 4| 3
Digital output point 19| 2| Digital output point 3| 2
Digital output point 18| 1| Digital output point 2| 1
Digital output point 17| 0| Digital output point 1| 0
Digital output point 32| 7| 3| Digital output point 16| 7| 1
Digital output point 31| 6| Digital output point 15| 6
Digital output point 30| 5| Digital output point 14| 5
Digital output point 29| 4| Digital output point 13| 4
Digital output point 28| 3| Digital output point 12| 3
Digital ioutput point 27| 2| Digital output point 11| 2
Digital output point 26| 1| Digital output point 10| 1
Digital output point 25| 0| Digital output point 9| 0
- E. g: The input start address assigned in the configuration project is 64, then the first point address is 64.0
- The 32nd point address is 67.7.
parameter data/request data
As shown in Figure 4.
DPP | SPDU | Object name | len gth | Scope | Defaults | |
---|---|---|---|---|---|---|
Index | Inde x | Subi ndex | ||||
Supplier ID | 2 | |||||
Device ID | 3 | 0x099CE9 | ||||
0x10 | 0 | Supplier name | 19 |
Read only
| FAS(Fujian)Co.,LTD
0x11| 0| Supplier text| 16| www.fas-elec.com
0x12| 0| Product name| 13| FNI IOL-106-006-K20
0x13| 0| Product ID| 6| 00BS14
0x14| 0| Product text| 44| IO-Link IP20 NPN 32DO
0x16| 0| Hardware version| 8| 20200615
0x17| 0| Firmware version| 4| 2.00
Mistake
As shown in Figure 5.
Error code | Additional code |
---|---|
Device app error 0x80 | Index unavailable 0x11 |
Subindex unavailable 0x12
Value out of range 0x30
Event
As shown in
Class/Qualifier|
Code(High Bit + Low Bit)
---|---
Pattern| Type| Instance
Appear| Error| AL| Hardware| Powered by| Power supply low voltage| U2=Power
supply+24V
0xC0| 0x30| 0x03| 0x5000| 0x0100| 0x0010| 0x0002
0xF3| 0x5112
Disappear| Error| AL| Hardware| Powered by| Power supply low voltage| U2=Power
supply+24V
0x80| 0x30| 0x03| 0x5000| 0x0100| 0x0010| 0x0002
0xB3| 0x5112
Appear| Error| AL| Hardware| Powered by| Peripheral power supply
0xC0| 0x30| 0x03| 0x5000| 0x0100| 0x0060
0xF3| 0x5160
Disappear| Error| AL| Hardware| Powered by| Peripheral power supply
0x80| 0x30| 0x03| 0x5000| 0x0100| 0x0060
0xB3| 0x5160