SIT Group 9957035 GTMF System Instruction Manual
- June 11, 2024
- SIT Group
Table of Contents
PROFLAME GTMF
SYSTEM
USE AND INSTALLATION INSTRUCTIONS
The Proflame GTMF is a modular remote control system that directs the functions of a hearth appliance. The Proflame GTMF is configured to control the on/off main burner operation, its flame levels and provides on/off and Smart thermostatic control of the hearth appliance. The system controls a remotely actuated 120V/60Hz power outlet, fan speed through six (6) levels and has a constantly powered 120V/60Hz power outlet.
TECHNICAL DATA
Remote Control
Supply voltage| 4.5 V (three 1.5 V AAA batteries)
Ambient temperature ratings| 0 – 50 °C (32 – 122 °F)
Radio frequency| 315 MHz
Receiver
Supply voltage| 6.0 V (four 1.5 V AA batteries)
Ambient temperature ratings| 0 – 60 °C (32 – 140 °F)
Radio frequency| 315 MHz
Fan Control Module
Supply voltage/frequency:| 120 V / 60 Hz
Ambient temperature ratings:| 0 to 60 °C (32 to 140 °F)
Three wires bus:| two wires to provide DC voltage to the receiver; one wire
gives uni-directionally signal from the receiver
Output voltage/frequency/current:| 120 V / 60 Hz / 5 A
Aux switched output:| 120 V / 60 Hz / 2 A
Fan speed output:| 120 V / 60 Hz / 1 A
WARNING
THE TRANSMITTER AND RECEIVER ARE RADIO FREQUENCE DEVICES.
PLACING THE RECEIVER IN OR NEAR METAL MAY SEVERELY REDUCE THE SIGNAL RANGE.
ATTENTION!
- TURN “OFF” THE MAIN GAS SUPPLY OF THE APPLIANCE DURING INSTALLATION OR MAINTENANCE OF THE RECEIVER.
- PLACE THE RECEIVER’S 3 POSITION SLIDER SWITCH IN THE “OFF” POSITION DURING INSTALLATION OR MAINTENANCE.
- TURN “OFF” MAIN GAS SUPPLY TO THE APPLIANCE PRIOR TO REMOVING OR REINSERTING THE BATTERIES IN THE RECEIVER.
- DURING APPLIANCE INSTALLATION/MAINTENANCE OR IN CASE OF REMOTE CONTROL MALFUNCTION TURN OFF THE FAN CONTROL MODULE USING THE “ON/OFF” MAIN POWER SWITCH ON THE FRONT PANEL OF THE FCM.
SYSTEM DESCRIPTION
The Proflame Remote Control System consists of three elements:
- Proflame Transmitter.
- Proflame Receiver and a wiring harness to connect the Receiver to the gas valve, stepper motor and Fan Control Module.
- Proflame Fan Control Module (FCM)
TRANSMITTER (Remote Control with LCD Display)
The Proflame Transmitter uses a streamline design with a simple button layout
and informative LCD display (Fig. 1).
The Transmitter is powered by 3 AAA type batteries.
A Mode Key is provided to Index between the features and a Thermostat Key is
used to turn on/off or index through Thermostat functions (Fig. 1 & 2).
Fig. 1: PROFLAME Transmitter.Fig. 2: Transmitter LCD display.
RECEIVER
The Proflame Receiver (Fig. 3) connects directly to the gas valve and stepper motor and Fan Control Module with a wiring harness. The Receiver is powered by 4 AA type batteries. The Receiver accepts commands via radio frequency from the Transmitter to operate the appliance in accordance with with the particular Proflame system configuration. The Receiver three position slider switch can be set to one of three positions: ON (Manual Override), Remote (Remote control) or Off.
Fig. 3: Proflame Receiver body.
FAN CONTROL MODULE
Fan Control Module (FCM) offers the added ability to control the fan speed through six (6) speeds, a remotely actuated 120V outlet and a constantly powered 120V outlet. The FCM provides DC power to the Receiver allowing the batteries to be used only when line power is interrupted or lost (Fig.4).
INSTALLATION
Receiver
The receiver can be placed inside a standard Junction type wall box or a low
temperature area of the appliance.
Wall Mounting
- Connect the wiring harness to the back of the Receiver.
- Install the Receiver in the Junction box using the existing J box screws. (Fig. 4)
- Insert the 4 AA type batteries in the battery compartment with the correct polarity.
- Place the slider into the cover plate.
- Put the Receiver switch in the “OFF” position.
- Make sure the Receiver and cover plate words “ON”and “UP” are on the same side.
- Align the slider with the switch on the Receiver and couple the switch into the slider.
- Align the screw holes.
- Using the two (2) screws provided secure the cover plate to the Receiver.
Hearth Mounting
- Connect the wiring harness to the back of the Receiver.
- Install the 4 AA type batteries in the battery compartment with the correct polarity.
- Make sure the Receiver and cover plate words “ON”and “UP” are on the same side.
- Place the slider into the cover plate.
- Align the slider with the switch on the Receiver and couple the switch into the slider.
- Using the two (2) screws provided secure the cover plate to the Receiver.
Fan Control Module
The FCM can be placed in a low temperature area of the appliance.
Connecting to the Gas Valve and FCM
The wiring harness for the Proflame GTM system has two wires labeled “TH” &
“TPTH”. Connect the wires to the gas valve as labeled. (TH to TH and TPTH to
TPTH). Additionally there are connectors labeled “Motor” and “COM”. Connect
the “Motor” connector to the stepper motor on the gas valve. Connect the “COM”
connector to the Fan Control Module connection labeled “COM” (Fig. 5).
OPERATING PROCEDURE
Initializing the System for the first time
Install the 4 AA batteries into the receiver battery bay. Note the polarity of
the battery and insert into the battery bay as indicated on the Battery cover
(+/-). Place the 3 position slider switch in the “Remote” position. (fig. 3)
Using the end of a paper clip, or other similar object, insert the end of the
paper clip into the hole marked “PRG” on the Receiver front cover (fig 3).
The Receiver will “beep” three (3) times to indicate that it is ready to
synchronize with a Transmitter. Install the 3 AAA type batteries in the
Transmitter battery bay, located on the base of the Transmitter. With the
batteries already installed in the Transmitter, push the On button. The
Receiver will “beep” four times to indicate the Transmitter’s command is
accepted and sets to the particular code of that Transmitter. The system is
now initialized.
Temperature indication Display
With the system in the “OFF” position, press the Thermostat Key and the Mode
Key at the same time. Look at the LCD screen on the Transmitter to verify that
a C or F is visible to the right of the Room Temperature display. (Fig.
6)
Turn on the Appliance
Press the ON/OFF Key on the Transmitter. The Transmitter display will show all
active Icons on the screen. At the same time the Receiver connects the
thermopile to the gas valve millivolt coil and the appliance main burner
turns on. A single “beep” from the Receiver will confirm reception of the
command.
Turn off the Appliance
Press the ON/OFF Key on the Transmitter. The Transmitter LCD display will only
show the room temperature and Icon (Fig. 7). At the same time the Receiver
disconnects the thermopile from the gas valve millivolt coil and the
appliance burner turns off. A single “beep” from the Receiver confirms
reception of the command.
Remote Flame Control
The proflame GTMF has six (6) flame levels. With the system on, and the flame
level at the maximum in the appliance, pressing the Down Arrow Key once will
reduce the flame height by one step until the flame is turned off.
The Up Arrow Key will increase the flame height each time it is pressed. If
the Up Arrow Key is pressed while the system is on but the flame is off, the
flame will come on in the high position. ( Fig. 8 & 9 ) A single “beep” will
confirm reception of the command.
ROOM THERMOSTAT ( Transmitter Operation)
The Remote Control can operate as a room thermostat. The thermostat can be set
to a desired temperature to control the comfort level in a room.
To activate this function, press the Thermostat Key (Fig. 1). The LCD display
on the Transmitter will change to show that the room thermostat is “ON” and
the set temperature is now displayed (Fig. 10). To adjust the set
temperature, press the Up or Down Arrow Keys until the desired set temperature
is displayed on the LCD screen of the Transmitter.
Smart Thermostat (Transmitter Operation)
The Smart Thermostat function adjusts the flame height in accordance to the
difference between the set point temperature and the actual room temperatures.
As the room temperature gets closer to the set point the Smart Function will
modulate the flame down.
To activate this function, press the Thermostat Key (Fig. 1) until the word
“SMART” appears to the right of the temperature bulb graphic (Fig. 12). To
adjust the set temperature, press the Up or Down Arrow Keys until the
desidered set temperature is displayed on the LCD screen of the Transmitter
(Fig. 13).
Fan Speed Control
If the appliance is equipped with a hot air circulating fan, the speed of the
fan can be controlled by the Proflame system. The fan speed can be adjusted
through six (6) speeds. To activate this function use the Mode Key (fig.1) to
index to the fan control icon (Fig. 14). Use the Up/Down Arrow Keys (Fig.1) to
turn on, off or adjust the fan speed (fig. 15). A single “beep” will confirm
reception of the command.
Remote Actuated 120V Auxiliary Outlet
The auxiliary function controls the AUX power outlet on the Fan Control
Module. To activate this function use the Mode Key (fig. 1) to index to the
AUX icon (fig. 16 & 17).
Pressing the Up Arrow Key will activate the outlet. Pressing the Down Arrow
Key will turn the outlet off. A single “beep” will confirm the reception of
the command.
Key lock
This function will lock the keys to avoid unsupervised operation.
To activate this function, press the MODE and UP Keys at the same time (fig.
18).
To de-activate this function, press the MODE and UP Keys at the same time.
LOW BATTERY P0WER DETECTION
Transmitter
The life span of the remote control batteries depends on various factors:
quality of the batteries used, the number of ignitions of the appliance, the
number of changes to the room thermostat set point, etc.
When the Transmitter batteries are low, a Battery Icon will appear on the LCD
display of the Transmitter (Fig. 19) before all battery power is lost. When
the batteries are replaced this Icon will disappear.
Receiver
The life span of the Receiver batteries depends on various factors: quality of
the batteries used, the number of ignitions of the appliance, the number of
changes to the room thermostat set point, etc.
When the Receiver batteries are low, No “beep” will be emitted from the
Receiver when it receives an On/Off command from the Transmitter. This is an
alert for a low battery condition for the Receiver. When the batteries are
replaced the “beep” will be emitted from the Receiver when the ON/OFF Key is
pressed (See Initialization of The System).
MANUAL BYPASS OF THE REMOTE SYSTEM
If the batteries of the Receiver or Transmitter are low or depleted, the
appliance can be turned on manually by sliding the three position slider
switch on the Receiver to the ON position.
This will bypass the remote control feature of the system and the appliance
main burner will come on if the gas valve is in the “On” position.
WARNING
Fire Hazard. Can cause severe injury or death
The Receiver causes ignition of the appliance. The appliance can turn on
suddenly. Keep away from the appliance burner when operating the remote system
or activating manual bypass of the remote system.
WARNING
Shock Hazard. Can cause severe injury or death
This device is power by line voltage. Do not try to repair this device.
In no way is the enclosure to be tampered with or opened.
Disconnect from line voltage before performing any manteinance.
WARNING
Devices rated more than 5A shall not connected to the FCM OUT receptacle.
Devices rated more than 1A shall not connected to the FCM FAN receptacle.
Devices rated more than 2A shall not connected to the FCM AUX receptacle.
CAUTION
Property Damage Hazard.
Excessive heat can cause property damage.
The appliance can stay lit for many hours. Turn off the appliance if it is not
going to be attended for any lenght of time.
Always place the Transmitter where children can not reach it.