SKU# 170600, 170601, 170602, 170603, 170604, 170605, 170606, 170607
Rated Voltage 220-240V~ 50Hz.
Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all instructions carefully before assembly, installation and use. Please keep instructions for future reference.

Warranty

  • This light fitting is covered by a 5-year warranty. The warranty is from the date of purchase, not the date of installation. Please retain the proof of purchase.
  • The use of non-compatible dimmers may damage your LED light fitting and will void your warranty.
  • The warranty will be void if there is any damage due to improper usage or modification to the fitting.
  • Failure to comply with the instructions in this manual may increase the risk of damage or injury and will void the warranty.

Installation Requirements

  • Before installation, check the installation location in the ceiling has access to a socket outlet which is connected to a wall light switch and dimmer. If it does not, please contact a licensed electrician to arrange the installation of the socket outlet, wall light switch and dimmer before continuing.

  • All wiring and installation of the light fitting must adhere to local and national wiring rules. eg. AS/NZS 3000:2007/Amendment 2:2012 Electrical installations. If unsure, please contact a licensed electrician.

  • The fitting is rated IP44 only after it is fully installed, this must be maintained during installation.
    NOTE: The LED driver and the back part of the fitting is rated IP20.

  • Select a suitable location for installation: – The mounting point must support 2 times the weight of the fitting. – This fitting is suitable for indoor or outdoor use, provided that it is installed under cover or under eaves.

  • This fitting is dimmable and has been tested at the date of publication with the dimmers listed in the specification section. The use of a LED dimmer such as the Lucci LEDlux SKU# 290998 or SKU# 290997 dimmer is highly recommended.
    NOTE: For the best dimming range, use the Lucci LEDlux SKU# 290998 dimmer and adjust the variable resistor at minimum and maximum dimming positions on the dimmer during the installation.
    NOTE: Dimming may cause buzzing sounds or a slight flicker. There may be slight delays with the LED light start-up or slight uneven light performance when more than one LED light fitting is linked together, switched ON or dimmed. This is not a product fault and as such is not covered under warranty.
    NOTE: Some dimmers have a minimum load of 20W. Ensure the dimmer position is on the maximum setting before turning on the LED light and adjust the dimmer down to your desired light level.

  • This fitting has an insulating ceiling type IC-4 rating. Building insulation material can safely be exposed continuously to temperatures up to 90°C may abut and cover the luminaire. (Please refer to the Clearance Information section and the IC-4 Rating section in this instruction manual for further details.)

  • If loose-fill insulation or thermal insulation is not fixed into position or if there are loose combustible materials (e.g. leaves or combustible materials stored in the roof space), a barrier or guard is required as per the Clearance Information section in this instruction manual.

  • The LED driver must be placed at least 100mm away from the LED downlight module to allow for cooling.

  • The LED driver can be placed under the insulation. (Please refer to the Clearance Information section in this instruction manual for further details.)

  • The LED downlight module is only suitable for use with Lucci LED Driver model#: ES0091D-E022.

  • The fitting must not be used if the diffuser on the LED downlight module has been damaged or cracked.

  • Take care not to pull any electrical wires during unpacking as this may damage the connection.

  • Lay out all the components on a smooth surface and make sure there are no components missing before assembling. If parts are missing, return the complete product to the place of purchase for inspection or replacement.

  • Check whether the fitting has been damaged during transport. Do not operate/install any product which appears damaged in any way. Return the complete product to the place of purchase for inspection, repair, or replacement.

  • Ensure power to the circuit you are working on has been switched OFF before commencing any electrical work.

Lucci decor 170600 City II Dimmable LED Downlight -
Fig

Clearance Information – AS/NZS 3000 Wiring Rules

Lucci decor 170600 City II Dimmable LED Downlight - Fig
1

LOCATION DISTANCE DESCRIPTION
A 50 mm(Minimum) Clearance between the top of the recessed luminaire and any

combustible materials, building elements or objects above it.
B| 50 mm (Minimum)| Clearance between the side of the recessed luminaire and any combustible materials, building elements or objects.
C| 0 mm(Abutted)| Insulation can be abutted against the side of the recessed luminaire and covered as per the IC-4 Rating. See the IC-4 Rating section for more details.
D| 100mm| Auxiliary equipment/driver/transformer must be placed 100mm away from the luminaire. It can be placed under thermal insulation and covered.

IC Rating – AS/NZS 60598.2.2: 2016

  1. A closed luminaire that allows building insulation to come into contact with its sides and to cover it.
  2. Type IC-4 recessed luminaire can be used together with building insulation that can safely be exposed continuously to temperatures up to 90°C may abut and cover the luminaire;
  3. The declared IC-4 rating is based on the default testing ambient temperatures 25°C according to the standard.

RISK OF FIRE – Required clearance from structural members and building elements
SCB = 50 mm HCB = 50 mm

Safety Tips

  • Always ensure the power is OFF and the fitting has cooled down before performing any maintenance, cleaning or making any adjustment to the fitting.
  • To avoid injury or damage to the fitting, ensure that power leads and screws are secure before connecting the power.
  • Select a suitable location away from liquids and hazards.
  • Ensure that the fitting does not come in contact with corrosive chemicals, etc.
  • To clean, wipe with a damp clean cloth. Never soak the fitting with water.

Troubleshooting

PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION
Does not work. (New installation) Wiring loose or no power to the downlight.

Check your circuit breaker/safety switch box and turn on power to your circuit.
Unplug the downlight and test in a functional socket outlet with power. If the downlight does not switch on then contact your nearest Beacon Lighting store. If the downlight is working, have your licensed electrician check the wiring or socket outlet to the downlight.
Does not work. (Existing installation)| No power to the downlight.| Check your circuit breaker/safety switch box and turn on the power to your circuit.
Contact your nearest Beacon Lighting store.
Flickers when dimming. (New installation)| Non-compatible dimmer used.| Check the dimmer used. Ensure the dimmer used is on the list of compatible dimmers in this manual.
Some dimmers have a variable loading adjustment function. eg. Lucci LEDlux SKU# 290998 dimmer.
This may not have been adjusted during the installation of the dimmer.| The variable resistor needs to be adjusted to suit the downlight load to reduce the flickering.
Flickers when dimming. (Existing installation)| Dimmer position on low.| Ensure the dimmer position is on the maximum setting before turning on the downlights and adjust the dimmer down to your desired light level.
Buzzing sound.| Non-compatible dimmer used.| Check the dimmer used. Ensure the dimmer used is on the list of compatible dimmers in this manual.
Uneven light start-up.| Dimmer position on low when switched on.| Ensure the dimmer position is on the maximum setting before turning on the downlights and adjust the dimmer down to your desired light level.

Specifications – V5.1

SKU # 170600 170601 170602 170603 170604 170605 170606 170607
Colour White Black Brushed
Brass Brushed
Chrome White Black Brushed
Brass Brushed

Chrome
Rated Voltage| INPUT: 220-240V~ 50Hz,
OUPUT: 33-40VDC, 0.22A, constant current,
Rated Wattage| 10W
LED Specs| HONGLI LED, 3000K, 800 lumens| HONGLI LED, 4000K, 800 lumens
Dimmer Information| Highly Recommended Dimmers| Compatible Dimmers
Lucci LEDlux SKU# 290998, SKU# 290997| LUMEX Load Smart LT1D450LS; DIGINET LED Smart MEDM; Clipsal 31E2RUDM, 32E450TM, 32E450UDM, 31E2PUDM and 32ELEDM; HPM: Cat. 400T
Weight| 0.42kg
Cut-out Size| Φ92mm
IP Rating| IP44 for LED downlight module
Dimensions| D:104mm x H:67mm
Serviceable Parts| The LED downlight module and LED driver are both serviceable.
LED Driver Model #| ES0091D-E022

Documents / Resources

| Lucci decor 170600 City II Dimmable LED Downlight [pdf] Instruction Manual
170600, 170603, 170602, City II Dimmable LED Downlight, Dimmable LED Downlight, LED Downlight, 70600, Downlight
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Lucci decor User Manuals

Related Manuals