Product Information

  • Product Name: BIOBEETM SEE-SAW ROCK system
  • Model Numbers: ROCK-I, ROCK-II, ROCK-III
  • Description: Gel rocker/ platform rocker designed for 24-hour use with smooth, jerk-free rocking action. IC controlled motor provides uniform movements at low speeds. Rubber mat is removable for easy washing and rubber bushes provide stable surface placement.
  • Technical Specifications:
    • Input Voltage: 230 V +/- 10% AC 50 Hz.
    • Platform size: 300 X 300mm
    • Speed: Variable, 10-60 oscillations/minute
    • No of Platforms: One Platform (ROCK-I), Two-platform (ROCK-II), One platform (ROCK-III)
    • Platform mat: Rubber mat with stripes
    • Max weight: Single platform 3.5 Kgs, Double platform, 2.5 Kgs each
    • Action: See-saw movement
    • Timer: NO (ROCK-I and ROCK-II), YES, 0-60 min digital (ROCK-III)

INTRODUCTION
Gel rocker/ platform rocker, which is designed to work for 24-hrs. Its jerk free movement gives smooth rocking action. The IC controlled motor gives uniform movements at very low speed also. It has rubber mat which is removable to ease washing. It has rubber bushes, which makes unit to stand firmly on the / table surface.

Product Usage Instructions

  1. Place the BIOBEETM SEE-SAW ROCK system on a stable surface.
  2. Select the appropriate model number based on your needs (ROCK-I, ROCK-II, ROCK-III).
  3. Ensure that the input voltage matches the specifications listed (230 V +/- 10% AC 50 Hz).
  4. Place the sample(s) to be rocked onto the rubber mat(s) on the platform(s).
  5. Turn on the unit and select the desired speed (variable, 10-60 oscillations/minute).
  6. If using the ROCK-III model, set the timer for up to 60 minutes if desired.
  7. The unit will begin to rock in a see-saw motion.
  8. When finished, turn off the unit and remove the sample(s).
  9. Remove the rubber mat(s) for easy washing if necessary.

Technical Specifications

Parameter Value: ROCK-I Value ROCK-II Value ROCK-III
Input Voltage 230 V +/- 10% AC 50 Hz. 230 V +/- 10% AC 50 Hz. 230 V +/- 10%

AC 50 Hz.
Platform size| 300 X 300mm| 300 X 300mm| 300 X 300mm
Speed| Variable,10-60  oscillations /minute| Variable, 10-60 oscillations /minute| Variable, 10-60 oscillations / minute
No of Platforms| One Platform| Two-platform| One platform
Platform mat| Rubber mat with stripes| Rubber mat with stripes| Rubber mat with stripes
Max weight| Single platform 3.5 Kgs,| Double platform , 2.5 Kgs each| Single platform 3.5 Kgs
Action| See-saw movement| See-saw movement| See-saw movement
Timer| NO| NO| YES, 0-60 min digital

Ordering Information

ROCK-I| BIOBEETM Gel rocker – SEE-SAW –Single platform
Gel platform size: 300 X 300mm,Analog Speed : 10-60 oscillations / minute, continuous usage/ cold room operation and user manual, Hsn Code:8479
---|---
ROCK-II| BIOBEETM Gel rocker – SEE-SAW -Double platform
Gel platform size: 300 X 300mm, Analog Variable speed : 10-60 oscillations / minute, continuous usage/ cold room operation and user manual, HSN Code:8479
ROCK-III| BIOBEETM Gel rocker – SEE-SAW -single platform- with Timer
Gel platform size: 300 X 300mm, Analog Variable speed : 10-60 oscillations / minute,
Digital Timer 0- 999 mins. and User Manual, HSN Code:8479

Vijaynagar, Bangalore-560 040
Tel: +91-80-23149608,080-23149602,
M: +91-0-9845264202,
E-Mail:sales@biobee.net,
URL: www.biobee.net

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals