Whynter MSFS-036H23016-01NEF Ductless AC and Heat Pump Mini Split System Instruction Manual
- June 11, 2024
- Whynter
Table of Contents
- MSFS-036H23016-01NEF Ductless AC and Heat Pump Mini Split System
- Product Information
- Product Usage Instructions
- DISPOSAL INFORMATION
- SAFETY PRECAUTIONS
- INTRODUCTION
- TECHNICAL DATA
- PARTS IDENTIFICATION
- OPERATING TEMPERATURE
- USING THE REMOTE CONTROL
- FEATURES OF THE REMOTE CONTROL
- MODES OF OPERATION
- SPECIAL FUNCTION FEATURES
- DISPLAY PANEL / SPECIAL FUNCTION FEATURES
- MANUAL OPERATION (WITHOUT REMOTE CONTROL)
- CARE AND MAINTENANCE
- OPERATION TIPS
- TROUBLESHOOTING
- ONE YEAR LIMITED PARTS WARRANTY & THREE YEAR WARRANTY ON COMPRESSOR
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MSFS-036H23016-01NEF Ductless AC and Heat Pump Mini Split System
Product Information
The Whynter Inverter Ductless Mini Split System Wireless Air Conditioner & Heat Pump Full Set is an air conditioning unit that provides both cooling and heating functions. It comes in four different models: MSFS-009H11519-01NEFa, MSFS-012H11519-01NEFa, MSFS-024H23019-01NEFa, and MSFS-036H23016-01NEF. It features a remote control, special function features, and a display panel. The unit has sensitive components that are protected by a fuse installed on the electronic card located in the indoor unit. The system power should be attached to the outdoor unit through a properly rated independent power circuit protected by a properly rated circuit breaker and a service disconnect switch box located near the outdoor unit.
Product Usage Instructions
Before using the Whynter Inverter Ductless Mini Split System Wireless Air Conditioner & Heat Pump Full Set, please read the instruction manual carefully and keep it in a safe place for future reference. To ensure proper operation, please follow these safety precautions:
- Properly position and install the appliance as detailed in the manual.
- Read the manual entirely before installing and using the appliance and follow all instructions and general safety rules carefully.
- Installation must be performed by an authorized certified HVAC contractor only.
- Installation must be performed according to all applicable and current national and local codes, regulations, and laws.
- During installation, the area within the indoor and outdoor sections of this split system must be restricted to all unauthorized personnel to avoid any accidents.
- Both indoor and outdoor units must be firmly fixed to the proper parts of the building’s structure.
- Only replace the fuse with the same rating when needed.
- System power should be attached to the outdoor unit through a properly rated independent power circuit protected by a properly rated circuit breaker and a service disconnect switch box located near the outdoor unit.
For more information on using the remote control, special function features, display panel, and modes of operation, please refer to the instruction manual.
DISPOSAL INFORMATION
Thank you for choosing the Whynter Air Conditioner Inverter Ductless Mini Split System Air Conditioner & Heat Pump. Please follow the instructions provided in this user guide to obtain the very best performance from your split air conditioner and take full advantage of the many features your air conditioner offers you. We trust that your Whynter air conditioner will provide the performance and reliability that we stand for. Please keep this user manual in a safe place for future reference.
This symbol on the product or its packaging indicates that the appliance cannot be treated as normal domestic trash, but must be handed in at a collection point for recycling electric and electronic appliances. Your contribution to the correct disposal of this product protects the environment. Further information about the recycling of this product can be obtained from your local municipal authority.
SAFETY PRECAUTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY WHEN USING YOUR AIR CONDIITIONER, FOLLOW THESE BASIC PRECAUTIONS:
Before the appliance is used, it must be properly positioned and installed as detailed in this manual.
-
Please read this manual entirely before installing and using this appliance and follow all instructions and general safety rules carefully. High voltages and pressures existing within this unit can cause serious harm to persons or property or even death. Installation must be performed in accordance with the requirement of NEC and CEC by authorized certified HVAC contractor only. Improper installation will cause irreversible damages and serious safety risks.
-
Installation must be performed according to all applicable and current national and local codes, regulations and laws.
-
During the installation, the area within the indoor and outdoor sections of this split system must be restricted to all unauthorized personnel to avoid any accidents.
-
Both indoor and the outdoor units must be firmly fixed to the proper parts of the building’s structure.
Sensitive components in this unit are protected by a fuse installed on the electronic card located in the indoor unit. Rating of this fuse is 5 Amps / 250 V. Only replace the fuse with the same rating when needed. -
System power should be attached to the outdoor unit through a properly rated independent power circuit protected by a properly rated circuit breaker and a service disconnect switch box located near the outdoor unit.
-
Ensure that the incoming voltage corresponds with the required power written on the rating plate. Make all connections tightly and waterproof to avoid risk of electrical shocks or fire due to insufficient contact.
-
All power wires, breakers and other components used to supply power to the unit must be approved for such use and properly rated for the load.
-
Always disconnect power before servicing.
-
This unit contains no user-serviceable parts. Always consult authorized service personnel for installation, repairing, and relocation of this product. Improper installation or handling will cause leakage, electrical shock, or fire.
-
If any parts such as the power cord is damaged, replacement or repair work shall be performed by authorized personnel only.
-
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by persons responsible for their safety.
-
Children should be supervised to ensure that they do not play with the appliance.
-
In the event of a malfunction such as burning smell, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult authorized HVAC service personnel.
-
In the event of refrigerant leakage, be sure to keep away from fire or any flammables, and consult authorized HVAC service personnel.
-
Ensure that any electronic equipment is at least 1 meter / 3 feet away from either the indoor unit or outdoor unit.
-
Do not climb on, place objects on, or hang objects from the unit.
-
Do not expose the unit directly to water.
-
Do not insert your fingers or any other objects into outlet port, open panel, or intake grille.
CAUTION: TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY WHEN USING YOUR AIR CONDIITIONER, FOLLOW THESE BASIC PRECAUTIONS:
- Air always contains some level of humidity. Any air left within the system or entering into the system will cause insufficient performance and irreversible internal compressor damage.
- Installer must carry out cycle tests and monitor and record of all related operational data before leaving the scene.
- Do not locate the system components near any inflammable substances, pressurized containers and moisture containing items.
- All packing materials are recyclable, please discard properly.
- Operate and regularly maintain the system as instructed in this manual.
- Warranty is valid only when the equipment is installed properly by licensed HVAC contractors and the warranty registration card must be properly filled out and sent to the manufacturer.
- System components must be installed where they can be accessed for maintenance and repairs easily.
- Sufficient clearances must be provided at all directions for removal of various panels.
- If you see lightning or hear thunder, there might be a lightning strike. To prevent electric shock hazard, turn off the air conditioner by using the remote control, and do not touch the unit or the power plug during thunderstorm.
- Always operate the unit with air filters installed.
- Always turn off the appliance when cleaning the air filter, and transporting.
- Unplug the power supply cable when not using the indoor unit for an extended period.
- Do not block or cover the intake grille and the outlet port.
- Do not place any other electrical products or household items under indoor unit or outdoor unit as dripping condensation from the unit might get them wet, and may cause damage or malfunction of your property.
- Do not abuse, sit on, or stand on the appliance.
- Do not drink or let pet(s) drink the drainage from the air conditioner.
- Do not touch the aluminum fins of heat exchanger built-in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit.
- Do not operate with wet hands.
- The design and specifications are subject to change without prior notice for product improvement.
INTRODUCTION
HOW IT WORKS
Ductless Mini Split system is the newest thing to hit the HVAC industry. This
is a new and energy efficient way to cool and heat a living or working space.
The technology goes by many names ductless air conditioning, mini split air
conditioner, mini ductless ac and others.
Ductless Mini Split system uses 2 Units, One Inside (Indoor unit; the
evaporator) and One Outside (Outdoor unit; the condenser). Essentially, this
is an air conditioner that is split into 2 units, similar to central air
conditioning. The difference is that split air conditioning consists of 2
units that are placed relatively close to each other. Best of all, you do not
need to perform any additional ductwork in your home, because this technology
uses no ducts at all.
The outside unit is the compressor unit, just like you`d see in a central air
conditioner system. The inside unit simply hangs on the wall, and hoses and
wires connect the 2 units together.
There are many advantages to Ductless Mini Split systems:
- The installation is simple and quick.
- The system is energy efficient because:
- Cooled air is not blown through duct work. Energy wasted in long lengths of uninhabited ductwork means higher energy bills.
- With Central Air you must cool an entire home when only one room may need cooling. On the other hand, ductless mini-splits cool only the areas you want and not the areas you don’t.
- The air conditioner is also a mini split heat pump, so you get year -round use of the unit.
- Ultra quiet operation as the louder components like compressors and motors are installed outdoors.
The advanced inverter technology used in the Whynter Ductless Mini Split Air Conditioners is the latest evolution of technology concerning the electro motors of the compressors. An inverter is used to control the speed of the compressor motor, so as to continuously regulate the temperature.
When the inverter air conditioning is switched on, the compressor operates at a high speed in order to cool or heat the room quickly. As the room temperature approaches the set temperature, the compressor slows down, maintaining a constant temperature and saving energy. Any sudden fluctuation in the room temperature will be sensed and instantly adjusted to bring the room temperature back to the set temperature. Below are the advantages of inverter technology.
- At least 30% – 50% cheaper to run as it consumes less power
- Quicker to achieve desired temperature
- Quieter operation
- No temperature fluctuations
- No voltage peaks from compressor
TECHNICAL DATA
Full Set Model#:
|
MSFS-009H11519-01NEFa
|
MSFS-012H11519-01NEFa
|
MSFS-024H23019-01NEFa
|
MSFS-036H23016-01NEF
---|---|---|---|---
Indoor Unit Model#:
|
MSI-009H11519-01NEFa
|
MSI-012H11519-01NEFa
|
MSI-024H23019-01NEFa
|
MSI-036H23016-01NEF
Outdoor Unit Model#:
|
MSO-009H11519-01NEFa
|
MSO-012H11519-01NEFa
|
MSO-024H23019-01NEFa
|
MSO-036H23016-01NEF
Operational Modes:
|
Auto, Cool, Fan, Dry, and Heat
|
Auto, Cool, Fan, Dry, and Heat
|
Auto, Cool, Fan, Dry, and Heat
| Auto, Cool, Fan, Dry, and Heat
Cooling Capacity:
|
9000 BTU
|
12000 BTU
|
24000 BTU
|
36000 BTU
Heating Capacity:
|
10000 BTU
|
12000 BTU
|
24000 BTU
|
36000 BTU
Coverage Area:
|
190 sq. ft
|
250 sq. ft.
|
330 sq. ft.
|
520 sq. ft.
Dehumidifying Capacity:
|
21.6 L
|
28.8 L
|
62.4 L
|
96 L
Fan Speed:
|
3 Fan Speed
|
3 Fan Speed
|
3 Fan Speed
|
3 Fan Speed
Filters:
| Carbon Filter (2)
High Density Filter (2)
| Carbon Filter (2)
High Density Filter (2)
| Carbon Filter (2)
High Density Filter (2)
|
Carbon Filter (2)
High Density Filter (2)
Thermostat Control Range (cooling/heating):
|
62° – 90°F / 32° – 86°F
17° – 32°C / 0° – 30°C
|
62° – 90°F / 32° – 86°F
17° – 32°C / 0° – 30°C
|
62° – 90°F / 32° – 86°F
17° – 32°C / 0° – 30°C
|
62° – 90°F / 32° – 86°F
17° – 32°C / 0° – 30°C
Timer:
|
24 hour programmable timer
|
24 hour programmable timer
|
24 hour programmable timer
|
24 hour programmable timer
Noise Level:| < 40 – 24 dBA| < 40 – 24 dBA| < 45 – 33 dBA| < 52 – 36 dBA
Refrigerant:| R410A| R410A| R410A| R410A
Air Flow
(at high speed):
|
247 CFM
|
294 CFM
|
589 CFM
|
852 CFM
Maximum Power Consumption:
|
782W / 7.0Amps
|
1200W / 10.4Amps
|
2525W / 11.2Amps
|
4235W / 18.5Amps
Power Supply:
|
115 V / 60Hz
|
115 V / 60Hz
|
230 V / 60Hz
|
230 V / 60Hz
EER:| 8.8| 8.8| 8.9| 8.5
SEER:| 16.5| 16.8| 16.5| 16
Unit Dimensions:
|
28.1” W x 7.6” D x 11.2” H
(Indoor Unit)
28.3″ Wx 10.6″ D x 19.5″ H
(Outdoor Unit)
|
31.7” W x 7.6” D x 11.2” H
(Indoor Unit)
28.3″ Wx 10.6″ D x 19.5″ H
(Outdoor Unit)
|
40.9″ W x 12.9″ D x 8.6″ H
(Indoor Unit)
35″ Wx 13.5″ D x 26.5″ H
(Outdoor Unit)
|
50″ W x 11″ D x 14.5″ H
(Indoor Unit)
37.5″ Wx 16.25″ D x 32″ H
(Outdoor Unit)
Package Dimensions:
|
30.7”W x 10.6”D x 14.2”H
(Indoor Unit)
32.6″ W x 11.7″ D x 21.3″ H
(Outdoor Unit)
|
34.3” W x 10.6” D x 14.2” H
(Indoor Unit)
32.6″ W x 11.7″ D x 21.3″ H
(Outdoor Unit)
|
44.1″ W x 15.9″ D x 12.2″ H
(Indoor Unit)
39.2″ W x 15.7″ D x 29.1″ H
(Outdoor Unit)
|
53″ W x 18″ D x 15″ H
(Indoor Unit)
43″ W x 20″ D x 34.5″ H
(Outdoor Unit)
Net Weight:
|
15.9 lbs (Indoor Unit)
54.7 lbs (Outdoor Unit)
|
17.2 lbs (Indoor Unit)
55.1 lbs (Outdoor Unit)
|
28.9 lbs (Indoor Unit)
97.9 lbs (Outdoor Unit)
|
41 lbs (Indoor Unit) 144 lbs (Outdoor Unit)
Gross Weight:
|
21.2 lbs (Indoor Unit)
58.9 lbs (Outdoor Unit)
|
22.9 lbs (Indoor Unit)
59.3 lbs (Outdoor Unit)
|
37.5 lbs (Indoor Unit)
104.5 lbs (Outdoor Unit)
|
54 lbs (Indoor Unit) 158 lbs (Outdoor Unit)
UPC (Full Set)
|
852749006405
|
852749006436
|
852749006689
|
852749006740
UPC (Indoor Unit
|
852749006412
|
852749006443
|
852749006696
|
852749006757
UPC (Outdoor Unit)
|
852749006429
|
852749006450
|
852749006702
|
852749006764
PARTS IDENTIFICATION
NOTE: Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different. The actual shape shall prevail.
OPERATING TEMPERATURE
| __
Cool Mode
| __
Heat Mode
| __
Dry Mode
---|---|---|---
__
Room Temperature
| __
62°F – 90°F / 17°C – 32°C
| __
32°F – 86°F / 0°C – 30°C
| __
50°F – 90°F / 10°C – 32°C
__
Outdoor Temperature
| __
32°F – 122°F / 0°C – 50°C
| __
5°F – 86°F / -15°C – 30°C
| __
32°F – 122°F / 0°C – 50°C
NOTE
- Optimum performance will be achieved within these operating temperatures. If air conditioner is used outside of the above conditions, certain safety protection features might come into operation and cause the unit to function abnormally.
- If the air conditioner runs for a long time in cooling mode and the humidity is high (over 80%), condensed water may drip out of the unit. Please sets the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
USING THE REMOTE CONTROL
Location of the Remote Control
- Keep the remote control where its signals can reach the receiver of the indoor unit (a distance of 26 feet is allowed).
- If you keep the remote control in a position that hinders proper signal transmission, a time lag of up to 15
minutes may occur.
CAUTION: To prevent malfunction or damage of the remote control:
- Do not place the remote control at where will not be exposed to direct sunlight or excessive heat.
- Remove batteries if the product is not going to be used for an extended period.
- Do not drop or apply strong pressure to the remote control.
- Do not pour water on the remote control.
- If leaking battery fluid comes in contact with your skin, eyes, or mouth, immediately rinse with plenty of clean water, and consult your physician.
- Use of other electrical appliances or nearby use of a wireless radio transmitter may cause the malfunction of the remote control.
Replacing batteries
The remote control uses two AAA dry batteries (included)
- Slide the cover of the battery compartment off according to the arrow direction, then replace the old batteries with new ones.
- Insert the new batteries making sure that the(+) and (-) of battery are installed correctly.
- Reattach the cover by sliding it back into position. After replacing the batteries, set the remote control clock.
NOTE: Do not dispose batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary
FEATURES OF THE REMOTE CONTROL
Note: Only use the remote control provided with the unit. If two or more indoor units are installed in proximity to one another, an indoor unit that is not intended to be operated may respond to the remote control.
Remote Control Holder
Install the remote control holder in a place where the signal can be received
by the indoor unit.
1. ON/OFF Button | Press this button to start or stop operation. |
---|---|
2. MODE Button | Press this button to select function mode in the follow |
order: AUTO, COOL, DRY, HEAT, and FAN
__
__
AUTO COOL DRY HEAT FAN
3. FAN Button| Press this button to change Fan Speed in 4 speeds – AUTO
LOW MED or HIGH. The fan speed can not be selected in AUTO and DRY mode .
4. SLEEP Button| Press this button to select the Sleep mode. This
function can only be used in AUTO, COOL and HEAT modes. Press Sleep button
again to can- cel.
NOTE: Changing function mode or fan speed will cancel the Sleep mode.
5. TURBO Button
__
__
__
SELF CLEAN Button
| Press this button in FAN, COOL or HEAT mode, the fan speed will be set at maximum speed.
Push again to cancel the TURBO function. Press this button to activate Self Clean function.
6. LED Button
__
__
__
FOLLOW ME Button
| Press this button to activate indoor unit light display. Press LED button again to turn off in- door unit light display.
__
Press this button to initiate the Follow Me feature and the remote control will display the temperature at its location. The remote control will send this signal to the air conditioner every 3 minutes interval until you press the Follow Me button again. The air conditioner will automatically cancel the Follow Me feature if it does not receive the signal during any 7 minutes interval.
NOTE: The Follow Me feature is not available in DRY and FAN mode. Shifting the operating mode or turning off the unit will cancel the Follow Me feature automatically. The remote control needs to be within 26 feet reach of the in- door unit for the Follow Me mode to work appropriately.
7. UP and DOWN Button| Press the UP button to increase the indoor temperature setting or to ad- just the TIMER (clock time) in a clockwise direction. Press the DOWN button to decrease the indoor temperature setting or to adjust the TIMER (clock time) in a counter-clockwise direction.
NOTE: Pressing and holding the UP and DOWN buttons together for 3 seconds will alternate the temperature display between the C & F
scale.
---|---
8. Silence / FP Button| Press Silence button once activate Silence mode. When
activated, the compressor will operate at low frequency and the indoor unit
will bring faint breeze, which will reduce the noise to the lowest level and
create a quiet and comfortable room for you. Due to low frequency operation of
compressor, it may result in insufficient cooling and heating capacity.
__
Press FP button for 2 seconds to active FP function (Freezing Protection). The unit will operate at a set temperature of 46°F. The display window of the indoor unit will display FP. Press the buttons of ON/OFF, SLEEP, FP, MODE, FAN SPEED UP or DOWN while operating will cancel the FP function.
Note: FP can only be activated only on HEAT mode.
9. TIMER ON Button| Press the Timer On button to program Timer Delayed Switch
ON function
10. TIMER OFF Button| Press the Timer Off button to program Timer Delayed
Switch OFF function
11. DIRECT Button| Press to change the louver movement and set the desired
up/down air flow direction. The louver changes 6° in angle for each press.
12. SWING Button| Press to stop or start horizontal louver auto-swing
feature.
Mode Display
Displays the current operation mode. Including Auto, Cool, Dry, Heat, and Fan.
| Sleep Display
Displays when SLEEP mode is set. Press the SLEEP button again to turn off.
---|---
Transmission Indicator ****
This transmission indicator lights when remote control transmits signals to the indoor unit.
| FOLLOW ME Display
Displays when FOLLOW ME function is activated.
ON/OFF display
Displays when the unit is On. Press the
ON/OFF button again to turn off the unit.
| Temperature/Timer display
Displays the timer set in (H) hourly increments and temperature settings in (°F) degree increments.
When unit is in FAN mode, no temperature setting is displayed.
TIMER ON display
Displays when TIMER ON time is set
TIMER OFF display
Displays when TIMER OFF time is set
| Fan Speed Display
Displays the selected fan speed: AUTO (no display), LOW ,
MED , and HIGH .
The fan speed is automatically set to AUTO when the operating mode on either AUTO or DRY mode.
NOTE: This air conditioner is equipped with a emergency switch which can be accessed by opening the front panel. This switch is used for manual operation in case the remote control fails to operate.
MODES OF OPERATION
AUTO MODE OPERATION
When you set the air conditioner in AUTO mode, it will automatically select
cooling, heating, or fan only operation depending on what temperature you have
selected and the room temperature. The indoor unit has a preset temperature of
76°F when AUTO mode is initially started.
- If the room temperature is 1°F(2°C) higher than the set temperature, the air conditioner will run in Cool mode.
- If the room temperature is 1°F(2°C) lower than the set temperature, the air conditioner will run in Heat mode.
- If the room temperature is 1°F(2°C) within the set temperature, the air conditioner will run in Fan mode.
NOTE: The fan speed is automatically selected and cannot be changed
COOL MODE OPERATION
In this mode, the air conditioner cools and dehumidifies the room. To activate
this function mode, press the MODE button on the remote control until the COOL
indicator display comes on. When the cooling mode is set, the compressor will
start in approximately 3 minutes. The cooling temperature setting range of
this air conditioner is from 62°F-90°F or 17°C-32°C. To set the temperature,
press the UP and DOWN buttons. This air conditioner has a 5°F temperature
cushion which if the set temperature is within 5°F of the ambient temperature,
the unit runs on fan only mode. This saves energy and prolongs the life of the
compressor of the air conditioner. To set the fan speed, press the FAN button.
In cooling mode, the difference in noise level between the 3 fan speeds is not
very noticeable. Try setting the unit to Fan only mode, you should be able to
hear the difference between high and low fan speed settings.
DRY MODE OPERATION
In this mode, the air conditioner only dehumidifies the room, the compressor
will activate intermittently depending on the ambient temperature and the fan
speed is set to LOW. To activate this function mode, press the MODE button on
the remote control until the DRY indicator display comes on. Please note that
when switching function mode, there will be an approximately 3 minute
transition time. NOTE: Fan speed is defaulted to AUTO and cannot be changed in
Dry Mode.
FAN MODE OPERATION
In this mode, the outdoor unit is deactivated and only the indoor unit’s fan
runs without any cooling or heating effect. To activate this function mode,
press the MODE button on the remote control until the FAN indicator display
comes on. Temperature setting buttons are deactivated. However, fan speed can
still be adjusted as desired.
HEAT MODE OPERATION
This air conditioner operates on the heat-pump principle, absorbing heat from
air outdoors and transferring that heat to the indoor unit. In this mode, the
air conditioner heats the room. To activate this function mode, press the MODE
button on the remote control until the HEAT indicator display comes on. When
the heating mode is set, the compressor will start in approximately 3-5
minutes. The heating temperature setting range of this air conditioner is from
32°F – 86°F / 0°C – 30°C . To set the temperature, press the UP and DOWN
buttons. To set the fan speed, press the FAN button. In heating mode, the
difference in noise level between the 3 fan speeds is not very noticeable. Try
setting the unit to Fan only mode, you should be able to hear the difference
between high and low fan speed settings.
TIMER ON SETTING
With the air conditioner is off, press the TIMER button. The TIMER ON light
will come on. Then set the desired time delay ON hours by pressing the UP and
DOWN buttons. The time increments are at 0.5 hour to up to 10 hours, followed
by 1 hour increment up to 24 hours. When the delay time set has elapsed, the
air conditioner switches on. To cancel the delayed switch on function, turn on
the air conditioner or adjust the time setting to 0.0.
TIMER OFF SETTING
With the air conditioner operating in any function mode, press the TIMER
button. The TIMER OFF light will come on. Then set the desired time delay OFF
hours by pressing the UP and DOWN buttons. The time increments are at 0.5 hour
to up to 10 hours, followed by 1 hour increment up to 24 hours. When the delay
time set has elapsed, the air conditioner switches off. To cancel the delayed
switch off function, turn off the air conditioner or adjust the time setting
to 0.0.
NOTE: Timer ON and Timer OFF setting can be set at the same time.
SLEEP MODE FUNCTION
The SLEEP function is used to decrease energy use while you sleep. In this
mode, the air conditioner gradually increases the set temperature in cooling
mode and decreases the set temperature in heating mode. In Sleep mode, the set
temperature is increased (cooling) or decreased (heating) by 1°C/ 2°F in the
first 2 hours. This new temperature will remain the same for 5 hours, after
which the air conditioner will automatically switch OFF. To activate this
function mode, press the SLEEP button on the remote control until the SLEEP
indicator light comes on. This function can only be used in AUTO, COOL and
HEAT modes.
NOTE: Changing function mode or fan speed will cancel the Sleep mode
AIR FLOW DIRECTION CONTROL
Air flow direction can be remotely controlled by pressing the SWING and DIRECT
buttons on the remote control.
- Press the SWING button to activate auto-Swing mode. The horizontal air louvers will start moving up and down. Pressing the SWING button again to cancel the auto-Swing mode and the air louver will stop. Press the DIRECT button to change the louver movement and set the desired up/down air flow direction. The louver changes 6° in angle for each press.
NOTES:
- A fixed louver angle in a high / horizontal angle is recommended for COOL and FAN modes for reaching across the room.
- A fixed louver angle in a low / downward angle is recommended for HEAT and DRY modes to prevent creating air draft effect on people.
- Never adjust the louvers by hand to prevent damage to the delicate driver motors.
- Manually adjust the deflector rods to direct the air to the right or left direction as desired. (see Fig. 1)
CAUTION
- Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dehumidifying mode. Otherwise, condensation may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings. (see Fig. 2).
- When the air conditioner is started immediately after it was stopped, the horizontal louver might not move for approximately 10 seconds.
- Open angle of the horizontal louver should not be set too small, as COOLING or HEATING performance may be impaired due to too restricted air flow area.
- Do not move the horizontal louver manually, otherwise the horizontal louver will be out of sync. Turn off the air conditioner for at least 3 minutes, then restart the unit.
- Do not operate unit with horizontal louver in closed position.
- Do not put your fingers in or near the blower and suction side of the unit. The high-speed fan inside the unit may cause injury.
SPECIAL FUNCTION FEATURES
TURBO FUNCTION
Turbo function will be helpful to cool or heat your room quickly and
effectively by operating at the maximum fan speed.
NOTE: Turbo function is only available in Cool and Heat mode.
LOUVER ANGLE MEMORY FUNCTION
Power failure during operation or pressing the ON/OFF button on the remote
control will stop the unit completely. When the power restores or pressing the
ON/OFF button on the remote control again, the unit restarts automatically
with the previous open angle of the horizontal louver by the louver angle
memory function. Press the AUTO/COOL manual button (on the indoor unit) and
the open angle of the horizontal louver will be restored to the standard
angle.
NOTE: It is highly recommend that the open angle of the horizontal louver
should not be set too small, in case the condensed water forms and drops from
the horizontal louver.
FOLLOW ME FUNCTION
The remote control serves as a remote thermostat allowing for the precise and
comfortable temperature control. With this technology, an efficient
temperature sensor is integrated in the remote control. To activate the Follow
me function, press Follow Me button on the remote control. Once this function
is activated, the remote control will send the temperature signal to the air
conditioner every 3 minutes interval until you press the Follow Me button
again. The air conditioner will automatically cancel the Follow Me feature if
it does not receive the signal during any 7 minutes interval.
NOTE: The Follow Me feature is not available in DRY and FAN mode.
Shifting the operating mode or turning off the unit will cancel the Follow Me
feature automatically. The remote control needs to be within 26 feet reach of
the indoor unit for the Follow Me mode to work appropriately.
SELF-CLEAN FUNCTION
Self Clean function will prevent growth of harmful micro-organisms by
eliminating the moisture inside of the indoor unit. In this function, the
indoor unit will run in fan mode for 11 minutes. Once the time has elapsed, a
low heat operation will run for 1 minute and will then switch to fan mode for
another 2 minutes. The appliance will automatically shut-off once the cycle
completes.
NOTE: It is recommended the use the Self Clean function every 15 days. In
high humidity environment, use it in a weekly basis. This will prevent rusting
of the air conditioner’s evaporator coil.
SILENCE FUNCTION
Press the “Silence” button on the remote control to initiate Silence function.
When the Silence function is activated, the compressor will run at a low
frequency rate and the indoor unit will bring faint breeze, which will reduce
the noise to the lowest level and create a quiet and comfortable environment.
LOW TEMPERATURE HEATING (FP mode)
The FP (Freezing Protection) mode is designed to run at ambient temperature as
low as 46°F / 8°C, which keeps the room temperature at a comfortable level
during the winter season.
NOTE: This unit uses heat pump for heating and the heating mode does not
work when temperature is below 45°F.
REFRIGERANT LEAKAGE DETECTION
With this safety feature, the indoor unit will display “EC” when it detects a
refrigerant leakage.
ANTI-COLD AIR FUNCTION
The unit is designed not to blow cold air on HEAT mode when the indoor heat
exchanger is in one of the following three situations and the set temperature
has not been reached.
- When heating has just started
- Defrosting
- Low temperature heating
To prevent cold air flow, the indoor unit’s fan will stop if the indoor coil temperature is lower than 62°F(17°C). The fan operation will resume once the indoor coil’s temperature is higher than 88F.
DISPLAY PANEL / SPECIAL FUNCTION FEATURES
Temperature and Function Display
- In FAN mode: shows room temperature.
- In other modes, the unit will display your temperature setting in °C or °F and AUTO timer setting.
- Display functions of the air conditioner:
- Displays “ON” for three seconds when Timer ON, Swing, Turbo or Sleep feature is activated.
- Displays “OF” for three seconds when Timer OFF is set and when Swing, Turbo or Sleep feature is cancelled.
- Displays “dF” when air conditioner is running in Defrost mode.
- Displays “cF” when anti-cold air feature is activated in Heating mode.
- Displays “SC” when air conditioner is running in Self-clean mode.
- Displays “FP” when air conditioner is running in Low Temperature Heating.
- Displays and spells “ECO” when ECO function is activated.
- Displays “EC” when air conditioner detects refrigerant leakage.
- Displays “CL” as a reminder clean air filters.
- Displays “nF” as a reminder replace air filters.
MANUAL OPERATION (WITHOUT REMOTE CONTROL)
In the event that your remote control fails to work, your unit can be operated
manually with the manual Auto/Cool button located on the indoor unit. Note
that manual operation is not a long-term solution, and that operating the unit
with your remote control is strongly recommended.
CAUTION: The manual button is intended for testing purposes and emergency
operation only. Please do not use this function unless the remote is lost and
it is absolutely necessary. To restore regular operation, use the remote
control to activate the unit.
Before manual operation, unit must be turned off. To operate your unit
manually:
- Open the front panel of the indoor unit.
- Locate the manual Auto/Cool button on the right-hand side of the unit.
- Press the manual Auto/Cool button one time to activate FORCED AUTO mode.
- Press the manual Auto/Cool button again to activate FORCED COOLING mode.
- Press the MANUAL CONTROL button a third time to turn the unit off.
- Close the front panel.
CARE AND MAINTENANCE
WARNING
- Never operate the air conditioner without the filters in place.
- Before cleaning the indoor unit, ensure the unit is turned off and all the power supply has been disconnected..
- Do not touch the aluminum fins of heat exchanger built-in the indoor unit to avoid personal injury when you maintain the unit.
CAUTION : Only use a soft, dry cloth to wipe the unit clean. If the unit is especially dirty, you can use a cloth soaked in warm water to wipe it clean.
- Do not use chemicals or chemically treated cloths to clean the unit.
- Do not use benzene, paint thinner, polishing powder or other solvents to clean the unit. They can cause the plastic surface to crack or deform.
- Do not use water hotter than 104°F (40°C) to clean the front panel. This can cause the panel to deform or become discolored.
- Do not expose filter to direct sunlight when drying. This can shrink the filter.
CLEANING THE AIR FILTER
Note: The high density filters and 3M carbon filters come pre-installed.
To ensure the air intake is filtered properly and to assure that your air conditioner runs efficiently, it is recommended to clean the washable high density filters at least once every two weeks.
- Lift the indoor unit panel up to an angle until it stops with a clicking sound. (See Fig. 15.1)
- Pull up the handle of the high density filters in direction of the arrow and release from the filter holder. Then pull the filters out with gently sliding it downward. (See Fig. 15.2 and 15.3)
- Use a vacuum cleaner or tap lightly to remove loose dust and dirt from the high density filters. Then rinse them thoroughly under warm or cold running water (no hotter than 100F.) (See Fig. 15.4)
- Remove the two carbon filters from its supporting frames. Cleanthe high density filters least once a month and replace it every 4-5months. Clean it with vacuum cleaner, then dry it in cool place. (See Fig. 15.5)
- Install the two carbon filters back into position.
- Insert the upper portion of air filters back into the unit, taking care that the left and right edges line up correctly and place filters into position. (See Fig 15.6). Close the front panel of the indoor unit.
AIR FILTER CLEANING REMINDER
After 240 hours of use, the display window on the indoor unit will flash “CL.”
This is a reminder to clean your filter. After 15 seconds, the unit will
revert to its previous display. To reset the reminder, press the LED button on
your remote control 4 times, or press the MANUAL CONTROL button 3 times. If
you do not reset the reminder, the “CL” indicator will flash again when you
restart the unit.
AIR FILTER REPLACEMENT REMINDER
After 2,880 hours of use, the display window on the indoor unit will flash
“nF.” This is a reminder to replace your 3M carbon filters. After 15 seconds,
the unit will revert to its previous display. To reset the reminder, press the
LED button on your remote control 4 times, or press the MANUAL CONTROL button
3 times. If you don’t reset the reminder, the “nF” indicator will flash again
when you restart the unit.
CAUTION
- Any maintenance and cleaning of outdoor unit should be performed by an authorized dealer or licensed service provider.
- Any unit repairs should be performed by authorized dealer or licensed service provider.
MAINTENANCE – LONG PERIODS OF NON-USE
- If the indoor unit will not be used for 1 month or more, turn on FAN operation for half a day to dry the internal parts thoroughly.
- Turn off the indoor unit and disconnect from its power source.
- Clean all filters and replace if necessary.
- Remove the batteries from the remote control.
MAINTENANCE – INSPECTION STANDARD CHECKLIST
- Check for damaged wires.
- Clean all filters and replace if necessary.
- Check for leaks.
- Replace batteries if needed.
- Make sure nothing is block all air inlets and outlets.
OPERATION TIPS
The following events may occur during normal operation:
Protection of the air conditioner.
Compressor protection
To prevent damages to the compressor, the compressor will not restart during
the protection circuit for about 3 minutes after sudden off operation.
Defrosting
-
Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low and hu-
midity is high resulting in lower heating efficiency of the air conditioner. -
For frost protection, a microcomputer-controlled automatic defrost function is equipped in this air condi-
tioner. If frost forms, the air conditioner will temporarily stop, and start defrosting automatically. The defrost indicator light on the indoor unit blinks during this operation. -
When unit is running on Defrost mode, the air conditioner will stop heating operation and start defrosting automatically.
-
The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and the amount of frost built up on the outdoor unit.
Mist or steam from the indoor unit
- Mist or steam may be generated due to a sudden and large temperature difference between air inlet and air outlet in COOL or DRY mode. This is common when the relative humidity is high.
- Mist or steam may be generated due to moisture generated from defrosting process in HEAT mode after defrosting.
Noise of the air conditioner
- Air conditioners may make sounds that are not familiar to you. The sounds listed below are normal.
- The compressor may make a pulsating or high-pitched sound.
- Refrigerant flowing may make a gurgling or low hissing sound.
- Fan sound may come from indoor unit.
- In Heat mode, a sizzling sound produced by the automatic defrosting operation may be heard.
Dusty air output
- This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit.
Smell coming from the unit
- This is caused by the smell from the interior, such as furniture, building material or cigarette smoke into the air conditioner.
The air conditioner turns to FAN only mode from COOL or HEAT mode.
- When indoor temperature reaches the set temperature, the compressor will stop automatically and the air conditioner runs in FAN only mode.
- The compressor will start again when the indoor temperature rises above the set temperature in Cool mode or drops below the set temperature in Heat mode.
Dripping water
- Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed.
Heating mode
- The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation. When the outdoor temperature falls, heat drawn in by the air conditioner decreases accordingly. At the same time, heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature. If a comfortable temperature can’t be achieved by the air conditioner, we suggest you use a supplementary heating device.
Malfunctions caused by other devices
- Lightning or wireless radio transmitter operating nearby may cause the unit to malfunction. If you encounter such a malfunction, restart the unit or turn off and restart the circuit breaker.
TROUBLESHOOTING
SAFETY PRECAUTIONS
If ANY of the following conditions occurs, turn off your unit immediately. Please do not attempt to fix these problems yourself. Contact an authorized service provider immediately.
- The power cord is damaged or abnormally warm.
- The unit emits burning odor.
- The unit emits loud or abnormal sounds.
- A power fuse blows or the circuit breaker frequently trips.
- Water or other objects fall into or out of the unit
The following problems are not a malfunction and in most situations will not require repairs.
Issue | Possible Causes |
---|---|
Unit does not turn on when pressing ON/OFF button | · The unit has a |
3-minute protection feature that prevents the unit from overloading. The unit can- not be restarted within three minutes of being turned off.
· Check the plug fuse.
· Timer is set.
The unit changes from COOL/HEAT mode to FAN mode| · The unit may change its setting to prevent frost from forming on the unit. Once the temperature increases, the unit will start operating in the previously selected mode again.
· The set temperature has been reached, at which point the unit turns off the compressor. The unit
will continue operating when the temperature fluctuates again.
The indoor unit emits white mist| · In humid regions, a large temperature
difference between the room’s air and the conditioned air can cause white
mist.
Water drops from the indoor unit| · Dripping water may generate on the
surface of the indoor unit when cooling in a relatively high humidity (RH more
than 80%). Adjust the horizontal louver to the maximum air outlet position and
select HIGH fan speed.
Both the indoor and outdoor units emit white mist| · When the unit
restarts in HEAT mode after defrosting, white mist may be emitted due to
moisture generated from the defrosting process.
The indoor unit makes noises| · A rushing air sound may occur when the
louver resets its position.
· A squeaking sound may occur after running the unit in HEAT mode due to expansion and con- traction of the unit’s plastic parts.
Both the indoor unit and outdoor unit make noises| · Low hissing sound during operation: This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units.
· Low hissing sound when the system starts, has just stopped running, or is defrosting: This noise
is normal and is caused by the refrigerant gas stopping or changing direction.
· Squeaking sound: Normal expansion and contraction of plastic and metal parts caused by tem- perature changes during operation can cause squeaking noises.
The outdoor unit makes noises| · The unit will make different sounds
based on its current operating mode.
Dust is emitted from either the indoor or outdoor unit| · The unit may
accumulate dust during extended periods of non-use, which will be emitted when
the unit is turned on. This can be mitigated by covering the unit during long
periods of inactivity.
The unit emits a bad odor| · The unit may absorb odors from the
environment (such as furniture, cooking, cigarettes, etc.) which will be
emitted during operations.
· The unit’s filters have become moldy and should be cleaned.
The fan of the outdoor unit does not operate| · During operation, the fan
speed is controlled to optimize product operation.
Operation is erratic, unpredictable, or unit is unresponsive| Interference
from cell phone towers and remote boosters may cause the unit to malfunction.
In this case, try the following:
· Disconnect the power, then reconnect.
· Press ON/OFF button on remote control to restart operation.
Issue | Possible Causes |
---|
Poor cooling performance
| Temperature setting may be higher than am- bient room temperature| ·
Lower the temperature setting
The heat exchanger on the indoor or outdoor unit is dirty| · Clean the
affected heat exchanger
The air filter is dirty| · Remove the filter and clean it according to
in- structions
The air inlet or outlet of either unit is blocked| · Turn the unit off,
remove the obstruction and turn it back on
Doors and windows are open| · Make sure that all doors and windows are
closed while operating the unit
Excessive heat is generated by sunlight| · Close windows and curtains
during periods of high heat or bright sunshine
Too many sources of heat in the room (people, computers, electronics, etc.)| ·
Reduce amount of heat sources
Low refrigerant due to leak or long-term use| · Check for leaks, re-seal
if necessary and top off refrigerant
SILENCE function is activated| · SILENCE function can lower product
perfor- mance by reducing operating frequency. Turn off SILENCE function.
The unit is not working
| Power failure| · Wait for the power to be restored
The power is turned off| · Turn on the power
The fuse is burned out| · Replace the fuse
Remote control batteries are dead| · Replace batteries
The unit’s 3-minute protection has been acti- vated| · Wait three minutes
after restarting the unit
Timer is activated| · Turn timer off
The unit starts and stops frequently
| There’s too much or too little refrigerant in the system| · Check for
leaks and recharge the system with refrigerant
Incompressible gas or moisture has entered the system| · Evacuate and
recharge the system with refriger- ant
The compressor is broken| · Replace the compressor
The voltage is too high or too low| · Install a manostat to regulate the
voltage
Poor heating performance
| The outdoor temperature is extremely low| · Use auxiliary heating
device
Cold air is entering through doors and win- dows| · Make sure that all
doors and windows are closed during use
Low refrigerant due to leak or long-term use| · Check for leaks, re-seal
if necessary and top off refrigerant
Indicator lamps continue|
flashing|
| The unit may stop operation or continue to run safely. If the indicator
lamps continue to flash or error
Error code appears in| codes appear, wait for about 10 minutes. The problem
may resolve itself. If not, disconnect the pow-
the window display of| er, then connect it again. Turn the unit on.
indoor unit:|
• E0, E1, E2…| If the problem persists, disconnect the power and contact
an authorized service provider.
• P1, P2, P3…|
• F1, F2, F3…|
ONE YEAR LIMITED PARTS WARRANTY & THREE YEAR WARRANTY ON COMPRESSOR
This WHYNTER Mini Split Inverter Ductless Air Conditioner System includes a one year limited parts warranty and additional two year compressor warranty. The system is warranted to the original owner while the product is still installed in the original place of the first installation. It must be purchased from an authorized Whynter dealer and installed by a certified installer within the 48 U.S. continental states, for one year from the original purchase date against part defects in material and workmanship under normal residential usage. To make a warranty claim on your WHYNTER Mini Split Inverter Ductless Air Conditioner system, the owner must contact the installer to diagnose and determine the cause of the issue. Upon the installer’s determination that the issue is caused by a defect covered under this warranty, the installer may contact Whynter’s Customer Support team with the following documents and information:
- Proof of purchase,
- Proof of installation by a licensed installer or provider,
- The system’s serial number,
- The installer’s service report, indicating the cause of the issue covered under the warranty,
- Whynter may request additional documentation or photos prior to processing he warranty claim.
Under this warranty, Whynter will replace any parts found defective by the installer with new or remanufactured parts or exchange the parts with a new, refurbished, or remanufactured parts at our discretion within one year from the date of purchase. All defective parts covered by this warranty will be installed and repaired by the installer or provider. Shipping costs for any parts are the responsibility of the owner. Return of the original or defective parts to Whynter may be requested in some instances before replacement parts can be provided. The compressor of the system is warranted for an additional two years after the one year limited parts warranty expires from the date of purchase. Should the compressor prove defective in materials or workmanship, under normal residential usage at the installer’s determination, during the two years following the initial one year parts warranty, Whynter will provide a replacement. Cost of labor, materials or other costs for supplies or materials purchased for the replacement of defective parts are the responsibility of the owner. Other costs, such as diagnosis, servicing, repair, replacement, installation, removal, transportation or shipping, etc. are NOT covered by this warranty. This warranty is not transferable. After the expiration of the warranty, all costs will be the responsibility of the original owner.
THIS WARRANTY DOES NOT COVER
- Acts of God or environmental conditions, such as fire, flood, hurricanes, earthquakes and tornadoes, etc.
- Improper power supply such as power surge, low voltage, defective household wiring or inadequate fuses.
- Use in commercial or industrial applications.
- Damage, accidental or otherwise, to the product while in the possession of a consumer not caused by a defect in material or workmanship.
- Damage caused by consumer misuse, tampering, lack of maintenance or failure to follow the care and special handling provisions in the instructions.
- Damage to the finish of the case, or other appearance parts caused by wear.
- Damage caused by repairs or alterations to the product by unqualified persons, installation by unlicensed providers, installers or contractors, installations that do not take place within 30 days of purchase.
- Installation costs, removal, repairs, diagnosis and service fees.
- Under-sizing, over-sizing, improper matching or selection of equipment for the required application.
- Products sold AS IS or from an unauthorized reseller. · Products that have had their serial numbers removed or defaced.
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
CUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE
REPALCEMENT PARTS AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES,
INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE,
ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS
THAN ONE YEAR. WHYNTER SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL
DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY
BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES
AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES,
SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY
GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM
STATE TO STATE.
The warranty, product contents and specifications are subject to change at any time without notice; please refer to www.whynter.com for the most current information.
To register your warranty, please visit
www.whynter.com and fill out the online. Warranty
Registration form. Please be sure to include a copy of your purchase invoice.
To obtain service or information, contact Whynter LLC via email at
support@whynter.com or call 866-WHYNTER
(866-949-6837).
Copyright © 2017 Whynter LLC www.whynter.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>