Omnitron Systems iConverter GX/TM2 Industrial Gigabit Media Converter
Product Information
The product is a network module that has several DIP-switches that control different settings for the module. The DIP-switches are located on Bank 1 and can be set to either Up or Down positions. The different DIP-switches control the following settings: – SW1: Fiber Negotiation AN/Man – SW2, SW3, SW4, and SW5: RJ-45 Mode of Operation – SW6, SW7, and SW8: Link Modes The module has additional settings that can be controlled via Serial Console/Telnet Console, NetOutlook Management Software or other third-party SNMP-based clients. Product UsageInstructions To use the product, follow these instructions:
- Locate the DIP-switch Bank 1 on the module. 2. Set the different DIP- switches to either Up or Down positions according to your desired settings. 3. For SW1, if the connecting fiber optic device cannot provide the proper signal to indicate its mode of operation, set the DIP-switch to the Up Man position. When Port 1 is set tothe Man position, no capabilities are advertised. 4. For SW2, SW3, SW4, and SW5, set the DIP-switches to appropriate positions based on the desired mode of operation. Refer to the table on Page 2 of the user manual for details on different modes of operation. 5. For SW6, SW7, and SW8, it is recommended to have link modes Down (default) during the initial installation. After the circuit has been tested and operational, configure the module for the desired mode. Refer to the table on Page 3 of the user manual for details on different link modes. 6. For additional settings that can be controlled via Serial Console/Telnet Console, NetOutlook Management Software or other third- party SNMP-based clients, refer to Page 4 of the user manual.
Product Overview
The iConverter GX/TM2 media converter and Network Interface Device (NID)
provides 10BASE-T, 100BASE-TX or 1000BASE-T copper to 1000BASE-X fiber media
conversion.
The GX/TM2 has built-in Operation, Administration and Maintenance (OAM)
functionality enabling the GX/TM2 to operate as a managed demarcation point at
the customer premises and network edge, offering Quality of Service
capabilities.
The GX/TM2 supports IPv4 addressing, IP-Less protocol using the 802.3ah OAM
channel, SNMPv1/v2c/v3, Telnet and serial console port.
See data sheet for available models.
- DIP-Switches
- DIP-Switch Bank 1
- The location of the DIP-switches is shown in below.
The functions of DIP-switch Bank 1 are outlined in below.
DIP-switch BANK 1 Definitions
SW1 – Fiber Negotiation “AN/Man”
When this DIP-switch is in the Down “AN” position (factory default), the fiber
optic port automatically determines the pause modes of the connecting fiber
optic device. If the connecting fiber optic device cannot provide the proper
signal to indicate its own mode of operation, the DIP-switch should be set to
the Up “Man” position. When Port 1 is set to the “Man” position, no
capabilities are advertised. Gigabit fiber always operate in Full-Duplex mode.
SW2, SW3, SW4 and SW5 – RJ-45 Mode of Operation
DIP-switches SW2, SW3, SW4 and SW5 control the setting of the RJ-45 port.
When SW2 is set to MAN and SW3 is set to 1000, the module is operating per the IEEE specification in Auto-Negotiation mode.
SW6, SW7, SW8 – Link Modes
These three DIP-switches configure the link mode settings. It is recommended
to have link modes Down (default) during the initial installation. After the
circuit has been tested and operational, configure the module for the desire
mode.
For detailed information on the operation of the different Link Modes, download the application note “iConverter Link Modes”.
Software Controlled Switch Settings
Additional settings are available via software control.
The following software settings can be controlled via Serial Console/Telnet
Console, NetOutlook Management Software or other third-party SNMP-based
clients:
- DIP-switch Configuration
- Port 1 and Port 2 Configuration
- 802.1ad Q-in-Q, QoS and Port Access Control
- MIB statistics
- Bandwidth control (rate limiting)
- Configurable Link Fault Propagation modes
The module can be configured by attaching the serial port to a DB-9 serial (RS-232) equipped computer with terminal emulation software such as ProComm or Putty. The Serial Console Port (DCE) is a mini DIN-6 female connector which can be changed to a DB-9 connector with the included adapter. Attach the ends of a serial cable to the serial port of the PC and the Serial Console Port of the module. The port is a standard RS-232 asynchronous serial interface with the following settings.
- Bits Per Second: 57,600
- Stop Bits: 1
- Data Bits: 8
- Parity: NONE
- Hardware Flow Control: NONE
The default password is public.
When using Telnet or SNMP, the default IP address for the module is
192.168.1.220.
For more information on using and configuring the Advanced Features, register
for access to the NetOutlook Management Software user manual or the GX/TM2
full user manual.
Mounting and Cable Attachment
Caution: Use proper ESD protection to reduce the risk of damage to your
equipment.
-
a. The module is available as a standalone module with integrated wall-mount brackets. Attach the unit to a wall, backboard or other flat surfaces. Make sure the unit is placed in a safe, dry and secure location.
For AC models:
To power the unit using the AC/DC adapter, connect the AC/DC adapter to an AC outlet. Then connect the barrel plug at the end of the wire on the AC/DC adapter to the 2.5mm DC barrel connector (center-positive) on the unit. Confirm that the unit has powered up properly by checking the power status LED located on the front of the unit.
For DC Models:
To power the unit using a DC power source, prepare a power cable using a two conductor insulated wire (not supplied) with 12AWG to 20AWG thickness. Cut the power cable to the length required. Strip approximately 3/8 of an inch of insulation from the power cable wires. Connect the power cables to the unit by fastening the stripped ends to the DC power connector.
Connect the power wires to the DC power source. The Power LED should indicate the presence of power.
WARNING: Note the wire colors used in making the positive and negative connections. Use the same color assignment for the connection at the DC power source.
NOTE: If mounting with a safety ground attachment, use the safety ground screw at the rear of the unit. -
b. When using a model with a SFP port, insert the SFP fiber transceivers into the SFP receptacles on the module.
NOTE: The release latch of the SFP transceiver must be in the closed (up) position before insertion. -
c. Connect the RJ-45 ports via a Category 5 or better cables to a 10BASE-T, 100BASE-TX or 1000BASE-T Ethernet devices.
-
d. Connect an appropriate multimode or single-mode fiber cables to the fiber ports of the installed module. It is important to ensure that the transmit (TX) is attached to the receive side of the device at the other end and the receive (RX) is attached to the transmit side. Single-fiber (SF) media converter models operate in pairs. The TX wavelength must match the RX wavelength at the other end and the RX wavelength must match the TX wavelength at the other end.
LED Indicators
Secifications
General and Copyright Notice
This publication is protected by U.S. and international copyright laws. All
rights reserved. The whole or any part of this publication may not be
reproduced, stored in a retrieval system, translated, transcribed, or
transmitted, in any form, or by any means, manual, electric, electronic,
electromagnetic, mechanical, chemical, optical or otherwise, without prior
explicit written permission of Omnitron Systems Technology, Inc.
The following trademarks are owned by Omnitron Systems Technology, Inc.:
FlexPointTM, FlexSwitchTM, iConverter®, miConverterTM, NetOutlook®,
OmniLight®, OmniConverter®, RuggedNet®, Omnitron Systems
- Technology, Inc.TM, OSTTM and the Omnitron logo.
- All other company or product names may be trademarks of their respective owners.
- The information contained in this publication is subject to change without notice. Omnitron Systems Technology, Inc. is not responsible for any inadvertent errors.
Warranty
This product is warranted to the original purchaser (Buyer) against defects in material and workmanship for a period of two (2) years from the date of shipment. A lifetime warranty may be obtained by the original purchaser by registering this product at www.omnitron-systems.com/support within ninety (90) days from the date of shipment. During the warranty period, Omnitron will, at its option, repair or replace a product which is proven to be defective with the same product or with a product with at least the same functionality.
For warranty service, the product must be sent to an Omnitron designated facility, at Buyer’s expense. Omnitron will pay the shipping charge to return the product to Buyer’s designated US address using Omnitron’s standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to product malfunctions resulting from
improper or inadequate use and/or maintenance of the equipment by Buyer,Buyer-
supplied equipment, Buyer-supplied interfacing, unauthorized modifications or
tampering with equipment (including removal of equipment cover by personnel
not specifically authorized and certified by Omnitron), or misuse, or
operating outside the environmental specification of the product (including
but not limited to voltage, ambient temperature, radiation, unusual dust,
etc.), or improper site preparation or maintenance.
No other warranty is expressed or implied. Omnitron specifically disclaims the
implied warranties of merchantability and fitness for any particular purpose.
The remedies provided herein are the Buyer’s sole and exclusive remedies.
Omnitron shall not be liable for any direct, indirect, special, incidental, or
consequential damages, whether based on contract, tort, or any legal theory.
Environmental Notices
The equipment covered by this manual must be disposed of or recycled in
accordance with the Waste Electrical and Electronic Equipment Directive (WEEE
Directive) of the European Community directive 2012/19/EU on waste electrical
and electronic equipment (WEEE) which, together with the RoHS Directive
2015/863/EU, for electrical and electronic equipment sold in the EU after July
2019. Such disposal must follow national legislation for IT and
Telecommunication equipment in accordance with the WEEE directive: (a) Do not
dispose waste equipment with unsorted municipal and household waste. (b)
Collect equipment waste separately. (c) Return equipment using collection
method agreed with Omnitron.
The equipment is marked with the WEEE symbol shown to indicate that it must be collected separately from other types of waste. In case of small items the symbol may be printed only on the packaging or in the user manual. If you have questions regarding the correct disposal of equipment go to www.omniton- systems.com/support or e-mail to Omnitron at intlinfo@omnitron- systems.com.
Safety Warnings and Cautions
ATTENTION: Observe precautions for handling electrostatic discharge sensitive devices.
WARNING
- Potential damage to equipment and personal injury.
- Risk of electrical shock.
Customer Support Information
-
Address: Omnitron Systems Technology, Inc. 38 Tesla Irvine, CA 92618, USA
-
Phone: 949-250-6510
-
Fax: 949-250-6514
-
Email: support@omnitron-systems.com
References
- Media Converters, NIDs, T1 and CWDM Multiplexers
- Omnitron Systems | Making Networks Reliable Since 1992
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>