SAWO SAV-90N SAVONIA Electric Heater Instruction Manual

June 11, 2024
SAWO

SAWO-LOGO

SAWO SAV-90N SAVONIA Electric Heater

Product Information SAVONIA Heater

The SAVONIA Heater is an electric heating device that provides warmth to indoor spaces. It comes with a separate control unit that allows users to adjust the temperature and power settings.

Installation Diagram for Separate Control NS

The installation diagram shows the recommended placement of the heater and sensors. The sensor location should be at least 1000mm away from air ventilation or 500mm away from air ventilation that is directed away from the sensors. The minimum safety distances for each model are also provided in the diagram.

SAWO-SAV-90N-SAVONIA-Electric-Heater-FIG-1

NOTE:
Please refer to the control unit manual for maximum power rating. Contactor unit is needed if heater’s power rating exceeds separate control units capacity. Additional contactor unit needs to be used when heater is 15kW or more.

NOTE
Do not place the sensors too near to air ventilation (not under 1000mm) or not under 500mm from air ventilation, which is directed away from sensors

Power Controller

The power controller regulates the amount of electricity that flows to the heater. The maximum power rating is specified in the control unit manual. If the heater’s power rating exceeds the capacity of the separate control unit, an additional contactor unit is needed. For heaters with a power rating of 15kW or more, multiple contactor units may be required.

Sensor Location

The sensor location depends on the distance between the heater and the wall. If the heater is placed more than 200mm away from the wall, the sensor should be located at least 150mm away from the heater. If the heater is placed less than 200mm away from the wall, the sensor should be located at least 1m away from the heater.

Product Usage Instructions

  1. Choose a suitable location for the SAVONIA Heater based on the installation diagram.
  2. Install the heater and sensors according to the recommended placement.
  3. Connect the power supply to the separate control unit.
  4. Refer to the control unit manual to determine the maximum power rating.
  5. Adjust the temperature and power settings using the separate control unit.
  6. If the heater’s power rating exceeds the capacity of the separate control unit, install an additional contactor unit.

Minimum Safety Distances

A B C D.

SAV-90N 110 50 1200 1900
SAV-105N 120 60 1200 1900
SAV-120N 130 70 1400 2100
SAV-150N 160 100 1400 2100
SAV-180N 160 100 1400 2100
SAV-180NV12 160 100 1400 2100
SAV-210NV12 160 100 1400 2100
SAV-240NV12 160 100 1400 2100

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>