Product Information
- Model No.: [insert model number here]
- Serial No.: [insert serial number here]
- Dealer: [insert dealer name here]
- Date of Purchase: [insert date of purchase here]
- Invoice No.: [insert invoice number here]
The product specifications are subject to change without prior notice. Please
contact customer service for details if necessary.
In case of any inconsistency or ambiguity between the English version and the
Chinese version of the user manual, the English version shall prevail.
Product Usage Instructions
To register your product for warranty, please visit the website
www.dchtoolbox.com.
If you need assistance or have any questions about the product, please contact
the DCH ToolBox Customer Service Centre at the following:
- Address: 204 4/F, DCH Building, 20 Kai Cheung Road, Kowloon Bay, Hong Kong
- Customer Service Hotline: (852) 8210 8210
- E-mail: 8210service@gilman-group.com
- Website: www.gilman-group.com
For further information on how to use the product, please refer to the user manual provided with the product.
Important Safe Guard
Do not operate the unit before carefully reading this instruction guide.
Please keep this manual for product warranty and future reference.
- Please be sure your electricity is correct
- Please do not place the device near a window or in the bathroom to prevent of electrical shock
- Please ensure the unit is not placed close to the high-temperature appliance in prevent of plastic destruction and fire.
- Never operate this unit in an explosive or corrosive atmosphere.
- Always guide if children operate. Never disassemble the unit, and never try to carry out repairs or adjust the unit yourself.
- Operate the unit on a stable surface to avoid vibration and noise.
- If toppled over, please pull out the plug at once.
- Make sure outlet ventilation is not blocked at all times.
9) Ensure air intake and air outlet ventilation is not blocked at all times.
- Do not spray water on the unit, spraying water may cause malfunctioning and electric shock.
- Never pull the socket by using damp hands.
12) Always switch off at the socket before unplugging to avoid electric shock
or arcing.
13) Switch off and unplu the unit, and empty and clean the water tank when not
using the unit for a long time.
14) Do not pull the power wire by force because it will cause damage to the
power wire.
- Never put fingers or other objects in any openings of the unit.
- You must pay attention when using the unit, and unplug the appliance during cleaning.
Ambient Environment For Operating
- Working condition: Ambient temperature: 5°C – 35°C.
- This device is only for indoor use e.g.: living room, bedroom, etc. Never use it in wet environment or outdoors.
- For the best efficiency and energy saving, make sure the door and window are closed before turning on the unit.
- Ensure that the unit is placed on a stable and flat floor surface. If the floor surface is not stable there is a risk that the unit may be unstable and toppled to cause excessive vibration and noise
Components Diagrams
Operating Introduction
Operation of Key Pads
Main Unit and Control Panel
- (On/Off): Switch on/off the power.
- Mode: Press the button to set automatic drying or dehumidification.
- Lock: Press the button for 3 seconds continuously to switch on/off all the lock functions of the keypads.
- Set: Press the button to set up humidity ranges of performance.
- Ion: Press the button to turn on/off the ionizer function.
- Swing: Press the button to switch on/off the swing performance.
- Speed: Press the button to set up the air speeds.
- Timer: Timer On/Off time settings.
Operation of Key Pads
-
When user plugs the device into power socket, 3 beep signals can be heard. ON/OFF: Press “ON/OFF” button to turn on the unit and the machine work at default mode –constant dehumidifying and high-speed running. And press the “ON/OFF” again to turn off the unit
-
Press ” Mode” to set dehumidifying or drying. (1) When the user presses the button of “Mode”, the device will enter “Dry” mode.-.the device works continue regardless of indoor humidity and the indicator light of “Dry ” and “High-speed fan” will illuminate. (Note: In the model of “Dry”, there is no response when the user presses the button of humidity and fan speed unless the user switch model into “Dehu”). (2) When user press “Mode” again, the device will switch into “Dehu” mode–. —the device works under setting humidity (40% ×50%-›60%-›70% -CO) and setting fan speed(High and Low) the indicator light will illuminate and the light of the high-speed fan will illuminate.
-
Press the button of “Lock” for 3 seconds to activate lock function,—there is no response to press any other buttons unless deactivating lock function by pressing “Lock” again by 3 seconds.
-
Press the “Set” to set desired humidity to 40%50%-60%-70%-CO. Set the 40%– expectation of environmental humidity value is 40%, when
the appliance detects that the current environment humidity is higher than or equal to 45%RH, the appliance start and fan runs at high speed; when the appliance detects that the current environment humidity is less than or equal to 39%RH, the machine will stop dehumidification and fan runs at low speed, the power indicator light will illuminate. It is similar to another humidity for 50%/60%/70%. -
Press the “lon” button to switch on/off the ionizer function. Meanwhile, the dehumidification starts and the indicator light illuminate.
-
Press the “Swing” button to switch on/off swing performance. Press “Swing” to oscillate the flapping air guide automatically. Press again to fix a stationary angle. When the swing function is activated, the corresponding indicator light illuminates.
-
Press “Speed” to select the fan working at “High speed” level or “Low speed” level. Meanwhile, the high or low-speed indicator light is illuminating.
-
Timer
-
Timer Off:
When the appliance is powered on, press Timer 1H/2H/4H/8H for the reservation of operating, timer symbol is displayed on LED screen. -
Time On:
When the appliance is powered off, press Timer 1H/2H4H/8H for power off, timer symbol is displayed on LED screen. -
Blue and orange decoration light
-
When the machine is on, the blue decoration light is on; when the machine is off, the blue decoration light is off.
-
When the water tank is full, the blue light is off, while the orange light is on. When the water tank is not full, the orange light is off, while the blue light is on.
-
“LIGHT”
-
When the machine is working, pressing the lon button and swing button for 3 seconds at the same time, the buzzer bleeps for one time, the blue decoration light will be off (Note: the “LOCK” light is on, if the machine is at “LOCK” mode).
-
When pressing the “Ion” button and “Swing” button for three seconds again, the buzzer beeps for one time, the blue lights show normally.
Water Full
When the tank is full, the device will automatically shut off and the buzzer
will alarm 10 times.
At the meantime, the LED light of power and “fully” illuminate
Memory function
- If the user turn off the unit and the device is in standby, the device will memory the last setting if user turns it on again.
- If power failure, the machine can not restart automatically and there is no memory function.
- If user set “child lock” and “timer”, the device will shut off when time is up, but no memory on the child lock when turn on unit again.
Automatic Defrosting
If the temperature sensor(NTC detects that the temperature on the copper tube
of the evaporator is <-1°C, the compressor will stop and the dehumidifier
starts to defrost. The light of Defrost is illuminated. The compressor will
only start working again after 10 minutes of defrosting and the temperature on
the copper tube is 22°C, the dehumidifier will work as the same status as
before, the light of Defrost is off.
(Note:1, when the dehumidifier is defrosting under “Dehu” mode then the fan
motor will work in High speed; , when it is defrosting under “Dry” mode then
the fan motor will work in the Turbo speed. 3, when the water tank full alarm
is on during defrosting, then the compressor will start to work for 30
minutes; (4), during such 30 minutes, if NTC detects that the tube’s
temperature is 20°C and last for 2 minutes, then the defrost is canceled; if
the tube’s temperature is 5-1 °C during this 2 minutes, then the defrost will
be started again after the 30 minutes’ working of compressor.).
Compressor protection function
This device is equipped with a compressor protection function–once the
dehumidifier is off, the compressor will delay 3 minutes to start when being
turned on immediately.
Refrigerant leakage detection function
The compressor will detect the temperature of the sensor and the temperature on the tube every 8 minutes; once the detected result being that the difference between these two temperature rates is up to 3°C in the latest 5 times, then it means refrigerant leakage. The compressor and fan motor will stop working, and the LED display will show “C8”. No reaction or sound when you touch any button at this situation. User has to unplug the dehumidifier and then plug it on again. (Note: the compressor will not detect when it is not working.)
Continuous Drainage
When continuous drainage is needed, please connect the included 15mm diameter
tube to the continuous drainage hole. The dehumidifier will keep working and
water will go out directly via the pipe. Then it won’t stop by the water full
situation. Please put the tube evenly on the ground when continuous drainage.
Any folded or uneven situation will be possible to stop the drainage.
Specification Table
The product specifications may be changed without prior notice.
Please contact customer service for details if necessary.
If there is any inconsistency or ambiguity between the English version and the Chinese version, the English version shall prevail.
Warranty Registration
Register your product online
www.dchtoolbox.com
DCH ToolBox Customer Service Centre
4/F, DCH Building, 20 Kai Cheung Road, Kowloon Bay, Hong Kong
Customer Service Hotline: (852) 8210 8210
E-mail: 8210service@gilman-group.com
Website: www.gilman-group.com