SAFETY PRECAUTIONS

  1. NOTE: Read instructions carefully for safe installation and fan operation.

  2. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and  knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
    Cleaning and maintenance shall not be undertaken by children without supervision.

  3. Children should be supervised to ensure that they do not play with the appliance.

  4. An all-pole disconnection switch must be incorporated into the fixed wiring, in accordance with local wiring rules.

  5. Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
    Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous  substances can leak into the ground water and get into the food chain, damaging your health and well-being.

  6. The structure to which the fan is to be mounted must be capable of supporting a weight of 21 kg.

  7. The fan should be mounted so that the blades are at least 2.3 m above the floor.

  8.  This fan is suitable for indoor and alfresco areas where the fan is fully undercover with a minimum of 2 wall. This fan is not waterproof. When installed in an alfresco or  coastal area, the ceiling fan must be positioned in a location protected from water, wind, dust and salt. Exposure to these elements will void the warranty. Mounting the  fan in a situation where it is subject to water or moisture is dangerous and may increase the risk of damage, injury or electrical shock and will void the warranty.

  9. Electrical installation should be performed by a qualified licensed electrician

  10. WARNING: If unusual wobbling or oscillating movement is observed, immediately stop using the ceiling fan and contact the manufacturer, its service agent or suitably  qualified persons.

  11. The replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent or suitably qualified persons.

  12. The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a sufficient strength to withstand 4 times the weight of the ceiling fan;  that the mounting of the suspension system shall be performed by the manufacturer, its service agent or suitably qualified persons.

  13. NOTE: This fan hanging system supports a maximum 6 degree angled ceiling installation.

  14. NOTE: The bracket screws provided are for use with wooden structures only. For structures other than wood, the appropriate screw type MUST be used. Ensure the  screws used are suitable for the mounting surface and the surrounding environment.

  15. NOTE: If there are two or more DC ceiling fans installed in the one location, an Isolation switch is required for each ceiling fan, this is required when programming the  remote and receiver to pair together.

  16. NOTE: Don’t run the motor without blades installed!

  17. NOTE: when use with extension down rod, use the light kit extension cable (J).

  18. NOTE: Fan installation step 15, if no lamp(N) is required, install the bottom cover(O) on the fan assembly. If lamp(N) is requited, install the lamp(N) on the fan  assembly.

PARTS LIST

LUCCI Airfusion Slipstream Dc Ceiling Fan - figLUCCI Airfusion Slipstream Dc Ceiling Fan - fig
2LUCCI Airfusion Slipstream Dc Ceiling Fan - fig
3LUCCI Airfusion Slipstream Dc Ceiling Fan - fig
4LUCCI Airfusion Slipstream Dc Ceiling Fan - fig
5LUCCI Airfusion Slipstream Dc Ceiling Fan - fig
6LUCCI Airfusion Slipstream Dc Ceiling Fan - fig
7LUCCI Airfusion Slipstream Dc Ceiling Fan - fig
8LUCCI Airfusion Slipstream Dc Ceiling Fan - fig
9LUCCI Airfusion Slipstream Dc Ceiling Fan - fig
10

USING YOUR CEILING FAN

NOTE: The remote and receiver will need to be paired after the installation of the ceiling fan.
PAIRING REMOTE & RECEIVER – WHEN 1 DC CEILING FAN IS INSTALLED IN ONE LOCATION
NOTE: Ensure that you have installed a single pole disconnection switch in the fixed wiring for the fan.
NOTE: Ensure power to the receiver is ON prior to pairing the remote with the receiver.

  • Turn OFF the mains supply to the fan by on/off wall switch.
  • Install the batteries into the remote. Please make sure the polarity of the battery is correct.
  • Turn ON the power to the receiver.
  • Press and hold the button on the remote for 3-5 seconds within 30 seconds of switching the power ON to the receiver of the ceiling fan.
  • There will be a notification ‘beep’ sound from the receiver to indicate that the paring process is successful.
  • Turn ON the fan and change the speed of the ceiling fan via the remote to check the operation and successful paring.
  • If pairing has been unsuccessful, repeat these set of steps again.

PAIRING REMOTE AND RECEIVER – WHEN 2 OR MORE DC CEILING FANS ARE INSTALLED IN ONE LOCATION

NOTE: Ensure that you have installed a single pole disconnection switch in the fixed wiring for each fan.

  • If you want to control 2 or more ceiling fans with one remote, do as explained in the normal pairing process, but make sure all ceiling fans wall switches are turned ON.
  • If you want to control them with individual remotes, do as explained in the normal pairing process, but make sure the other ceiling fans wall switches are turned OFF.  After the first fan is paired turn the wall switch OFF and continue the normal pairing process with the next fan.

REMOTE CONTROL

LUCCI Airfusion Slipstream Dc Ceiling Fan - fig 11

  1. Reverse control
  2. Natural wind (The fan speed automatic cycle between 1 to 6 speed)
  3. Speed control
  4. Light On/Off
  5. Fan On/Off
  6. 1.5V AAA battery x 2 pcs (Included)

LUCCI Airfusion Slipstream Dc Ceiling Fan - fig 12

The remote has memory function. If the fan or light is turned off by the isolating switch, it will memories and recover the last status when turned on next.
REPAIRING THE REMOTE & RECEIVER PAIRING – WHEN 1 CEILING FAN IS INSTALLED

  • If the remote and receiver lose control after installation or during use, the pairing of the remote and the receiver must be repaired.
  • Below are the operating symptoms and the steps to repair the pairing of the remote and receiver.

Symptoms:

  • Loss of control – Fan is only running at high speed after installation

AIRFUSION SLIPSTREAM

  • Loss of control – No reverse function after installation
  • Loss of control – Remote cannot communicate with the receiver

Repairing Steps:

  • Switch OFF the main power to the ceiling fan for 30 seconds.
  • Switch ON the main power of the ceiling fan. Follow the same process as described in the ‘Paring remote & receiver’ section to repair the pairing.
  • Turn on and select the different speed of the ceiling fan to check the operation of the fan.

AFTER INSTALLATION

WOBBLE:
NOTE: ceiling fans tend to move during operation due to the fact that they are mounted on a rubber grommet.
If the fan was mounted rigidly to the ceiling it would cause excessive vibration. Movement of a few centimeters is quite acceptable and DOES NOT suggest any problem.

TO REDUCE THE FAN WOBBLE:
Please check that all screws which fix the mounting bracket and down rod are secure.
BALANCING KIT: A balancing kit is provided to balance the ceiling fan on initial installation. Please refer to the instruction on how to use the balancing kit. The balancing  kit can be used to assist re-balancing should the ceiling fan become un-balanced again. Store your balancing kit away after installation for future use if required.

NOISE:
When it is quiet (especially at night) you may hear occasional small noises. Slight power fluctuations and frequency signals superimposed in the electricity for off-peak hot  water control, may cause a change in fan motor noise. This is normal. Please allow a 24-hour “settling-in” period, most noises associated with a new fan disappear during this  time.
Please note that this is not a product fault and as such is not covered under warranty – All electric motors are audible to some extent.

CARE & CLEANING

NOTE: Always turn OFF the power at the mains switch before performing any maintenance or attempting to clean your fan.

  • Every 6 months periodic cleaning of your ceiling fan is the only maintenance required. Use a soft brush or lint free cloth to avoid scratching the paint finish. Please turn  off electricity power when you do so.
  • Do not soak or immerse your ceiling fan in the water or other liquids. It could damage the motor or the blades and create the possibility of an electrical shock.
  • Ensure that the fan does not come in contact with any organic solvents or cleaners.
  • To clean the fan blade, wipe with only a damp clean cloth with NO organic solvents or cleaners.
  • The motor has a permanently lubricated ball bearing so there is no need to oil.

SAFETY PRECAUTIONS FOR BATTERY

– WARNING – Keep new and used batteries away from children.
– CAUTION – Do not ingest battery—Chemical burn hazard.
– Always use 2 x AAA battery type with this ceiling fan remote controller.
– Ensure the batteries are inserted with the correct polarity.
– To prevent false operation during battery insertion or replacement, this ceiling fan must be disconnected from the supply mains.
– Remove batteries from the product when not in use for long periods of time.
– Batteries must be removed from the remote transmitter before it is discarded.
– Dispose of exhausted batteries immediately and safely (so they cannot be retrieved by children).
Batteries can still be dangerous. Contact your local council to safely dispose of the battery.
– Regularly check the product and make sure the battery box lid is correctly secured. If the battery compartment does not close securely, stop using the product and keep it  away from children.
– If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention. If you suspect your child has swallowed or inserted a button battery, call the emergency number of your country if you are in Europe for fast, expert advice.
– Battery Leaks: Battery contains chemicals and should be treated as any chemical would. Take precautions when handling leaked battery chemicals. Battery chemicals should  not be placed near the eyes or ingested. call the emergency number of your country if you are in Europe for fast, expert advice.

TECHNICAL INFORMATION

Fan 42″ & 48″ &52″ DC fan – SLIPSTREAM
Fan Models SLIPSTREAM-42″ – 4B WH, SLIPSTREAM-42″ – 4B BLK,

SLIPSTREAM-48″ – 4B WH, SLIPSTREAM-48″ – 4B BLK,
SLIPSTREAM-52″ – 4B WH, SLIPSTREAM-52″ – 4B BLK
/ SKU#213302, SKU#213303, SKU#213304, SKU#213305, SKU#213306, SKU#213307
Rated Voltage| 220-240V– 50Hz
Rated Wattage (Motor)| 42″ Slipstream – 22W / 48″ & 52″ Slipstream – 26W
Lighting source| This product contains a light source of energy efficiency class < F >
Rated wattage (Lamp)| GX53 (SKU#121354 / SKU#121359), Max.12W (SKU#121354 Included)
Battery for remote| 2 x AAA (Included)
Weight| 5.18kg
Canopy Dimensions| H:51mm Dia:138mm

WARRANTY INFORMATION

IN EUROPE – If you are a European customer, please contact the retail outlet where the fan was purchased for warranty service.