PHILIPS BVP281 Flood Lighting Luminaire Instruction Manual
- June 11, 2024
- Philips
Table of Contents
BVP281 Flood Lighting Luminaire
Installation Instruction
BVP 281 Flood Lighting Luminaire
Type : BVP281
Light Source : LED’s
Voltage : 240V, 50-60 Hz
IP Classification : IP-66
Net Weight : 2.0 kg
Application : Outdoor use only
Warning
-
The luminaire shall be installed by a qualified electrician.
-
Turn power off before inspection, maintenance, installation or removal.
-
Refer to technical datasheet for additional electrical properties to ensure safe
installation. -
Luminaire installed must not be in contact with combustible materials.
-
Ensure power supply cables (L-N-E) are connected correctly before
Switching on. -
The connection of power cable on luminaire is type Y. If the external flexible
cable or cord of the luminaire is damaged, it shall be exclusively replaced by
the manufacturer or his service agent or a similar qualified person in order to
avoid hazard. -
The light source of this luminaire is not replaceable, when the light source
reaches its end of life the whole luminaire shall be replaced. -
Warranty void if earthing is not connected.
Maintenance
-
Periodic cleaning of the luminaire glass cover will ensure max. optical
Efficiency. -
Luminaire glass cover shall be cleaned with water and non-abrasive
soap, cleaner or detergent solution.
Caution
1. The luminaire must be used within the applicable product specifications,
installation instructions and environmental conditions for storage &
operations
according to applications guidelines provided by Philips for product Warranty
to be valid.
2. In case the front glass is found broken/ damaged, it should not be powered
on and is to be replaced before using the luminaire.
All the pictures in the MI sheet are representative only and may vary from the actual product.
Installation
1
Red/ Brown- Live
Grn- Yel- Earth
Black/ Blue- Neutral
Use proper junction box of IP66
protected for termination of the wire
to ensure electrical safety and
product performance.
(Junction Box is not part of the supply)
2
Adjust the aiming of the luminaire
and tighten the mounting screws on
the side for locking in position using
a torque of 8 N-m.
3
Caution: Gland shall never be
above the centre line.
All the pictures in the MI sheet are representative only and may vary from the actual product.
Read User Manual Online (PDF format)