Overview
Product Information
The BP 1 Barrel is a water pump designed for use in private households to remove rainwater from collection containers. It has a maximum flow rate of 3800 liters per hour and a maximum pressure of 0.11 MPa (1.1 bar). The pump is powered by a 230-240V, 50Hz motor with a power consumption of 400 watts. It has a noise level of 44 dB(A) and weighs 5.6 kg. The pump comes with a hose connection and a drum holder for secure placement.
Product Usage Instructions
- Prior to initial use, read the operating instructions and safety instructions carefully.
- Ensure that the pump is placed on a stable and level surface.
- Connect the hose to the pump and attach it to the drum holder.
- For manual operation, move the level switch upwards. For automatic operation, ensure that the switch is in the correct position.
- To stop the pump, turn off the power supply.
- The pump requires no maintenance.
- When transporting the pump, ensure it is secured to prevent slipping.
- Store the pump by tilting the drum holder forward and placing it in a safe and dry location.
Note that the BP 1 Barrel is not intended for commercial use and is suitable only for pumping water with impurities up to a maximum grain size of 1mm, water from swimming pools (provided the dosing of additives is proper), and washing lye. The packaging material is recyclable and should be disposed of appropriately. Please refer to the warranty terms published by the relevant sales company in your country for information on warranty coverage and repair procedures.
General information
Please read these original operating in-structions and the enclosed safety in- structions prior to the initial use of your device. Proceed accordingly. Keep both booklets for future reference or subsequent owners. Please keep in mind that the label “100% tested” may not be removed from the pump. If the label is removed, there will be no more warranty for the tightness of the pump.
Proper use
This appliance has been designed for use in private households and is not intended for commercial use. The manufacturer is not responsible for any damages that may occur on account of improper use or wrong op-erations. The appliance is mainly intended to remove rain water from collection containers.
Approved fluids
- Water with impurities up to a maximum grain size of 1mm
- Water from swimming pool (provided the dosing of additives is proper)
- Washing lye
Environmental protection
The packaging material can be recycled. Please do not place the packaging into the or-dinary refuse for disposal, but arrange for the proper recycling. Old appliances contain valuable materials that can be recycled. Please arrange for the proper recycling of old appliances. Please dispose your old appliances using appropriate collec-tion systems.
Notes about the ingredients (REACH)
You will find current information about the ingredients at:
www.kaercher.com/REACH
Operation
Description of the Appliance
- Power cord with plug
- Drum edge holder
- Locking valve
- O ring
- Housing bowl for level switch
- Housing cover for level switch
- Hose coupling
- Pressure hose
- Hose clamp
- Level sensor
- Level switch attachment
- Carrying handle
- Hose connection G3/4 (24.4 mm) for hose coupling
Before Startup
- Screw the hose connection on to the pump
- Connect the hose connection to the hose coupling of the drum edge holder.
DANGER
Risk of mortal danger on account of electric shock!Do not touch the feed fluid
and the rope fastened to the carrying handle during operation.
NOTICE
- The liquid level must at least be 3 cm for the pump to suck in liquids independently.
- If the prerequisites for the pump operation are met (wa-ter level, position / level switch), the pump will start im-mediately after the mains plug has been plugged in.
Comfort operation
In order to run the pump independently of the water lev-el, the level
switch must be mounted inside the housing. Illustration
- Screw the housing bowl and the O-ring onto the drum edge holder.
- Place the level switch into the housing bowl.
- Press the housing cover down onto the housing bowl until it locks. Illustration
- Slide the drum edge holder onto the container edge until it is properly seated.Illustration
- Place the pump on a stabil surface in the liquid to be transported. Immerse it using a rope tied to the handle or hang it into the container by the hose. The suction area should not be blocked fully or par-tially through the impurities.Illustration
- Close locking tap (arrow horizontal).
- Insert the mains plug into the socket.
- Rotate the housing with the level switch in the ar-row direction “ON”.
- The pump will turn on.
- Open the locking tap to remove water (arrow verti-cal).
Automatic operation
In the automatic mode, the level switch automatically controls the pumping
operations. The pump switches on or off when the fluid level reaches the
height that has been set.
Ensure that the level sensor is not obstructed in any way. Illustration
- In automatic operation, set the required switching height by clamping the level switch cable into the stopper.
- Open the locking tap to remove water (arrow vertical).
- Insert the mains plug into the socket.
Manual operation
In manual operations the pump remains switched on continuously. Illustration
- In manual operations mode, align the level sensor upward (cable pointing downward). Tip: Push the cable of the level sensor like a loop through the handle.
- Open the locking tap to remove water (arrow vertical).
Insert the mains plug into the socket.
NOTICE
Dry running leads to increased wear and tear; do not leave the pump unattended
during manual operation. Switch off the pump within 3 minutes of dry running.
Finish operation
NOTICE: Soiling can deposit and lead to malfunctions.
- Rinse the pump with clean water after use. This especially applies after pumping chlorinated water or other liquids that leave residue.
- Rotate the housing with the level switch in the ar-row direction “OFF”. The pump will turn off.
- Disconnect the main plug from the socket.
Maintenance
The pump is maintenace-free.
Transport
CAUTION: In order to prevent accidents or injuries, keep in mind the weight of the appliance during transport (see Spec-ifications).
- Lift and carry the pump on the carrying handle.
- If you want to transport the appliance on a vehicle secure it from slipping.
Storage
CAUTION In order to prevent accidents or injuries, keep in mind the
weight of the appliance when selecting a storage lo-cation for it (see
Specifications).
Storing the Appliance
- Tip the drum edge holder forward and take out to-ward the top.
- Completely drain the pump and allow it to dry.
- Store the appliance in a frost free area.
Special accessories
2.645-193.0/| Universal hose coupling Plus, for 1/| Recessed grips made of
soft plastic ensure easy han-
---|---|---
2.645-203.0| 2″, 5/8″ and 3/4″ hoses| dling. Universally useable for all
common garden hoses.
2.645-148.0| Hose PrimoFlex plus, 25 m, 3/4″| Phthalate-free 3/4″ garden hose
for connecting the pump with the application equipment.
Troubleshooting
Caution
- To avoid risks, all repairs and replacement of spare parts may only be carried out by authorized customer service personnel.
- First pull out the plug from the mains before carrying out any tasks on the machine.
Fault | Cause | Remedy |
---|---|---|
Pump runs but does not transport | Air in the pump | Plug in/ pull out the mains |
plug of the pump a few times till the fluid gets sucked
Suction area blocked| Pull out the mains plug and clean the suction area
(only in manual mode) Water level be- low the minimum water level| Immerse the
pump deeper into the liquid, if possible.
Pressure hose is blocked| Pull out the mains plug and clean the pressure hose
Locking tap is closed (arrow horizontal).| Open the locking tap (arrow
vertical).
Pump does not run or suddenly comes to a standstill during opera- tions| Power
supply interrupted| Check fuses and electrical connections
Thermal protection switch in the motor has switched off the pump as it was
overheated.| Pull out the mains plug, let the pump cool down, clean the
suction area, prevent dry running
Dirt particles have got jammed into the suction area| Pull out the mains plug
and clean the suction area
Pump operation stopped by sensor| Check position of level sensor
Pumping capacity is re- ducing| Suction area blocked| Pull out the mains plug
and clean the suction area
Pumping capacity too low| The pumping capacity depends on the flow height,
hose diameter and hose length.| Keep max. flow height, see technical data. If
neces- sary, select a different hose diameter or hose length.
Our Kärcher branch will be pleased to help you further in the case of questions or faults. See address on the reverse.
Specifications
BP 1 Barrel | ||
---|---|---|
Voltage | V | 230 – 240 |
Current type | Hz | 50 |
Output Pnom | W | 400 |
Max. flow rate | l/h | 3800 |
Max. pressure | MPa (bar) | 0.11 |
(1.1)
Max. flow height| m| 11
Max. immersion depth| m| 7
Max. grain size of the dirt particles that can be transported| mm| 1
Weight| kg| 5.6
Sound levels (EN 60704-1)| dB(A)| 44
Mains cable length (EN 60335-2-41)| m| 10
Reason for exception according to regulation (EU) 2019/1781 Annex I Section 2
(12): (j)
Subject to technical modifications.
The possible delivery rate is even larger:
- the smaller the suction and delivery heights are.
- the larger the diameter of the hoses used are.
- the shorter the hoses used are.
- the less loss of pressure is caused by the connected accessories.
Warranty
The warranty terms published by the relevant sales company are applicable in each country. We will repair potential failures of your appliance within the warranty period free of charge, provided that such failure is caused by faulty material or defects in manufacturing. In the event of a warranty claim please contact your dealer or the nearest authorized Customer Service center. Please submit the proof of purchase.
QR SCAN
http://www.kaercher.com/dealersearch
Alfred Kärcher GmbH & Co. KG
- Address: Alfred-Kärcher-Str. 28 – 40 71364 Winnenden (Germany)
- Tel.: +49 7195 14-0
- Fax: +49 7195 14-2212
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>