Instruction for use

About the manual

The instructions contain all the information needed for debugging and using the controller. Only the staff with electrical technology can debug the controller.

Validity range of this manual

This manual is valid for all parts of the charging pile controller.
This product is based on international standards IEC61851 and SAEJ1772.
Note: SAEJ1772 is a standard for electric vehicle chargers proposed by the Society of Automotive Engineers.

Recycle and treatment

The material of the controller has environmental compatibility and can be recycled.
In order to meet the environmental protection requirements, please contact a certified professional company that specializes in handling such waste to deal with electronic waste

Safety Instruction

Precautions and hazards

Note: please follow the safety instructions and legal guidelines.
Due to the different installation requirements in different countries and regions, the installation personnel are responsible for ensuring that the product installation can meet the local legal requirements.
Danger: voltage hazard
Contact with live components will cause serious injury. Please cut off the power supply of all systems and devices before operation.

Fuse

Warning: improper fusing may cause heat or fire The internal self- resetting fuse is only used to protect the controller, and the installation personnel are responsible for the safety of the circuit.

Repair

It is not allowed to repair, and the defective device shall be disposed (abandoned) under the condition of meeting the environmental protection requirements.
Warning: opening the device without permission can cause danger
Opening the device without permission may cause harm to the user or cause significant damage or property loss.
Note: if the device is changed in violation of regulations, the manufacturer’s warranty will be invalid. Any unauthorized changes will void the warranty.

Description

Controller Features

The controller is a kind of product suitable for charging pile of electric vehicle.

(1) Software correction instructions, such as EKEPC1 or EKEPC2
(2) Maximum charging capacity indication 10A, 16A, 20A, 25A, 32A, Through the internal dial switch (The factory default setting is 32A).
(3) “C” for the cable version and” S” for the socket (without cable) version

Select controller additional functions: Switch the DIP switch to “ON” which corresponding to the functions you need The functions of the corresponding positions are described as follows: In the “ON” position

  1. Socket version working mode
  2. Added RCMU(DC6mA) module function
  3. Function with IC card
  4. With electronic lock function
  5. DBL current balance working mode
    External can connection LCD mode The functions of the corresponding positions are described as follows: In the “OFF” position
    1: Cable version working mode
    2: None RCMU(DC6mA) function
    3: Lost(without) IC card working mode
    4: Without electronic lock function
    5: Normal working mode
    6: External can connection LCD

External can connection LCD

Scope of use

The communication to control the charging procedure of electric vehicle conforms to electric vehicle
standard IEC61851 or SAEJ1772.
According to DIN EN60715 installation requirements.
The output of the relay is used to connect the switching load contactor.
The operation status of vehicle interface is displayed by LED.
The controller can be connected to the following external functions:
contactless IC card connection module, DC leakage detection module (rcmu), RS485 communication
interface equipment, gun head lock device (DC12V), external emergency stop button. These functions need to be explained when ordering

Application cases

The following is a schematic diagram of an application case.
For example, item C with 1 pcs type B circuit breaker and 1 pcs contactor; item A、B with 1pcs typ A circuit breaker plus RCMU module and 1 contactor.

Application cases

Application cases
Application cases
Application cases

Function description

Charging process of controller with cable type (only CP signal is needed) After switching on the working voltage, the module starts to initialize and perform the function self test (LED light flashes circularly), waiting for the car to connect. The controller waits for the charging cable to connect to the vehicle (status a), and the LED flashes blue continuously. If the cable matching with the controller has been connected (state B), the LED turns to stable blue light and turns on the electromagnetic lock switch. After the gun head interlock, if the vehicle is in State C, the controller will make P1/ P2 in closed state (connected state), and the LED will turn to stable green light. If status D (ventilation required) is displayed, because the controller has no heat dissipation function, the controller makes P1 / P2 in the open state (off state) and turns off the electromagnetic lock switch at the same time, the gun head interlock will be invalid, and the controller will turn off the charging procedure, and the LED will turn into a stable red light

Function description

Charging process of controller without cable type(socket type)(connecting CP and CS signals)
Before the power is turned on, the CS signal port of the controller can not be connected to any device ,after the working voltage is turned on, the module starts to initialize and perform function self-test (LED lights flash circularly), waiting for the connection of the car cable, this lights flash circularly), waiting for the connection of the car cable, this process takes about 10 s.e. The controller waits for the charging cable to connect to the vehicle (status A), and the LED flashes blue continuously. If the cable matching with the controller has been connected (state B), the LED turns to stable blue light and turns on the electromagnetic lock switch(if have). After the gun head interlock(if have), if the vehicle is in State C, the controller will make P1 / P2 in closed state (connected state), and the LED will turn to stable green light. If status D (ventilation required) is displayed, because the controller has no heat dissipation function, the controller makes P1 / P2 in the open state (off state) and turns off the electromagnetic lock switch(if have) at the same time, the gun head interlock will be invalid, and the controller will turn off the charging procedure, and the LED will turn into a stable red light.  In E and f States, the LED will not be on again when the electromagnetic lock switch is off and the controller turns off the charging procedure.
In the fault state, the controller turns P1 / P2 on (off) and turns off the electromagnetic lock switch. The LED turns red and flashes continuously.

Ventilation requirements

In the absence of ventilation, the risk of asphyxiation may be caused due to the accumulation of some battery related gases when charging indoor. If the charging process is carried out indoor, forced ventilation shall be installed, the charging pile controller does not have forced ventilation function.
Connection confirmation line (CS) current, resistance correspondence information. current resistance/ current resistance/ current resistance / current resistance/ current resistance 32A 732Ω / 25A 536Ω / 20A 432Ω / 16A 348Ω / 10A 249Ω When the input resistance (minimum) is lower than 100Ω, it cannot be charged or interlocked. The controller will reduce the current load to 7a within 5S, and the controller will enter Status A until the resistance value of the input current rises.

LED display and troubleshooting

LED Display
There are three colors of display, the specific working status and functions are as follows:

Controller connection status

on

No.

| State Code| LED Color| LED State| PE、CP、PP state| Controller state| Remark Power self-check failed!
---|---|---|---|---|---|---
0| K| Red| 5Hz flashing| Power self detect failed| Fault–1#| Please turn the power back on!
1| A| Blue| 1Hz flashing| CP disconnection| Ready|
2| I| Blue| 2Hz flashing| Waiting for IC card| RFID Waiting|
3| B| Blue| Stabilization| CP connect to diode+2.7KΩ| Connected|
4| B| Blue| Stabilization| CP connect to diode+1.3KΩ| Connected|
5| C| Green| Green brightening| CP connect to diode+2.7KΩ
parallelconnect1.3KΩ| Charging|
6| D| Red| Stabilization| CP connect to diode+2.7KΩparallelconnect1.3KΩ parallel            connect             270R Or     CP     connect     to diode+270R  Or CP connect to diode+270R parallel connect 2.7KΩ Or CP connect to diode+270R parallel connect 1.3KΩ| Fault–2#| Need Ventilation! PClP- PE short ctihrcuit!
7| F| Red| 1Hz flashing| CP line short circuit with PE line| Fault–3#| ease check   e CP line
8| H| Red| 5 Hz flashing| RCMU occurs residual current or self detect failed| Fault–4#| sReClMf-iUnslepaekcatgioenofrailure
9| E| Red| 2Hz flashing| Diode short circuit

(Requirement waiting the CP disconnected)

| Fault–5#| EV-Charing Socket Fault PSPLIsT PP wciret,
10| G| Blue+Red| 2Hz flashing| PP line disconnection| Fault–6#| lea e che k he PP line
11| J| Red+Green+Blue| 2Hz flashing| Electromagnetic Lock failed| Fault–7#| Electronic Lock Disabled
12| L| Blue| 5Hz flashing| IC card failed| Fault–8#| RFID card is not valid

DCirBcuit ovearcloiad,

13| M| Red+Green| 1Hz flashing| Circuit overload,DLB Mode activated 11| Fault–9#| L Mode t vated

Installation

Installing to DIN rail
  1. Install the controller (a) vertically on the horizontal DIN rail (b).
  2. Rotate the device down until the slider on the DIN rail snaps in.
    (Note: DIN rail: rail in accordance with German industrial standards)
    Installation

Wiring

Warning: improper (connection) fuses can cause heat or fire.
The internal self-reset fuse is designed only for the protecting device itself, and it is the responsibility of the controller’ S user or factory operator to protect the circuit related to the control. This device does not include the contactor of load output. Improper use of the contactor of load output will cause heat or fire when the line is overloaded. The contactor of load output is installed from outside by the factory operator.
Warning: through the controlling signal, the maximum charging current borne by the vehicle shall not exceed the maximum charging current specified by the EPC controller, otherwise personal injury or property loss will be caused.

Notice

L/N is connected to the main board’ s line.
5.1 Connecting terminal blocks and terminal assignment
Wiring

“C: with cable version”means that the charging cable is permanently connected to the controller; P1 / P2 terminal is connected to the AC contactor providing the charging load. The rated value of Curve B circuit breaker shall be selected within the maximum current range circuit breaker shall be selected within the maximum current range.
Wiring

Notice

When selecting the cable, its temperature resistance needs to be at least 75°C. If the temperature resistance fails to meet the requirements, personal injury or property loss will be caused. Warning: The conductor sections should be designed to conform to the standard system construction. The cable must conform to the type of line, otherwise it will cause personal injury or property loss.

Terminals arragemnet specification

Terminal function specification

Serial
number| Mark| function| Specification
---|---|---|---
| L| Live line| Product working power supply:AC230V±10% 50Hz
2| N| Neutral line
3| P1| Relay coil A1|

AC contactor connected to the connection load of charging station

4| P2| Relay coil A2
5| FB| Reflect signal of the
electromagnetic lock| This is the feeback signal on the electromagnetic lock directly to the passive contact output terminal of the electromagnetic lock
6| FB
7| LK+| Electromagnetic lock positive voltage| Provide positive and negative pulse voltage of electromagnetic lock, duty cycle of  output pulse (1: 3) and total pulse output maximum driving capacity of 500ms
8| LK-| Electromagnetic lock negative voltage
9| 0V| Earth terminal| External indicator light, DC5V/10mA drive capability
10| RED| Red LED
11| GRE| Blue LED
12| BLU| Green LED
13| IC| IC card – controlled input signal| The signal of external non-contact IC card reading module, input is TTL voltage signal,DC 3.3V/

5.2 AC 230V

Wiring example 230V AC

5.2 AC 230V

Wiring instructions

Controller signal line P1 : Blue 2.5 mm2
Controller signal line N : Blue 2.5 mm2
Contactor coiling opening and closing line N : Blue 2.5 mm2
Power output line N: Blue 4mm2
Continuous output line N: 2.5 mm2
Contactor coiling opening and closing line L: Brown 2.5 mm2
Controller signal line L : Brown 2.5 mm2
Continuous output line L: 2.5 mm2
Power output line L: 4 mm2 WAGO 1 WAGO 2 Curve B RCCB Controller Contactor Terminal blocks Input line Input line of charging plug Two colors signal grounding wire 2.5 mm2 Black signal wire 0.5 mm2
Brown outgoing line L: 6 mm2
Blue outgoing line N: 6 mm2
Two colors grounding wire: 6 mm2

Functional grounding Vehicle interface shall conform to IEC61851

  1. Connect“CP”directly to the interface of vehicle charging terminal.
  2. Firstly connect the ground wire (PE line) of the vehicle charging terminal interface to the OV control point of the EPC controller, and then connect other lines in order. Do not use terminal blocks or EPC controller to connect the device from the outside at OV control point.
    OV control point shall be consiste nt with the expected current of the factory. The connection of EPC controller to OV is functional grounding, and the reliability of connection must be guaranteed,otherwise personal injury or property loss will be caused.
Relay output

We recommend connection with 230 / 400V 10kA curve B RCCB. Cutting off the power branchAccording to IEC61851, it is required to cut off the power branch when the charging process is completed within 100ms.
The EPC controller will stop the relay output after detecting that the power branch is cut off.
Warning: To cut off the power branch, especially the contactor, the total power-off time shall not exceed the required 100ms.

Replacement device

Maintenance
EPC charging controller is maintenance free.
Warning: There is no replaceable fuse inside EPC When replacing, make sure that the device and the components associated with the device are not energized.
Danger: Voltage hazard Touching any running parts will cause serious injury. Please cut off the power before operation.

Process

  1. Cut off the line from the EPC controller terminal.
  2. Pull the latch down from the back of the unit and rotate until it is free of the DIN rail and removed.
  3. Installation: connect the rear lock clipper to the DIN rail and swing until the lock clipper was put in.
  4. Reconnect the line (On).
  5. Turn on the switch and the main power.Cleaning Cleaning of the unit is not allowed

Dimensional drawings(mm)

Dimensional drawings\(mm\)

RS485 Communication description

Modbus-RTUmodel , Baud rate: 38400, fixed , address: 1-255 default : 255( Broadcast address )

Register address number| Data description (power failure protection)| Read and write| Type of data| Defaults
---|---|---|---|---
100| Device address number| Read and write| 16-bit integer| 255
101| DLB maximum starting current| Read and write| 16-bit integer| 9000
102| DLB maximum current (100.00A)| Read and write| 16-bit integer| 10000
103| Reference current: DLB/current transformation ratio (100.00A)| Read and write| 16-bit integer| 10000
104| Reference current calibration value input| Read and write| 16-bit integer| 1270
105| Charging pile current transformation ratio 50-200A| Read and write| 16-bit integer|
106| Charging pile current value correction 0-100.0A| Read and write| 16-bit integer|
107| Charging pile voltage value correction 0-500.0V| Read and write| 16-bit integer|
108| Charging pile power value correction 0-22000W| Read and write| 16-bit integer|
109| Maximum output PWM duty cycle of charging pile| Read and write| 16-bit integer| 90%
110| RCMU function selection 0 disabled 1 enabled, other values are selected by DIP switch| Read and write| 16-bit integer| 3
111| RFID function selection 0 disabled 1 enabled, other values are selected by DIP switch| Read and write| 16-bit integer| 3
112| Lock function selection 0 disabled 1 enabled, other values are selected by DIP switch| Read and write| 16-bit integer| 3
113| Cable function version selection 0 disable 1 enable, other values are selected by DIP switch| Read and write| 16-bit integer| 3
114| DLB function selection 0 disable 1 enable, other values are selected by DIP switch| Read and write| 16-bit integer| 130

0

115| PID control parameter P of DLB| Read and write| 16-bit integer| 1
116| PID control parameters of DLB I| Read and write| 16-bit integer| 100
117| DLB PID control parameter D| Read and write| 16-bit integer|
118-119| Controller ID number up to 9 digits| Read and write| 32-bit integer|
120-139| spare| Read and write| 16-bit integer| 1002
140| Software version| Read only| |
141| Current working status: Corresponding status 0-13| Read only| 16-bit integer|
142| PWM value of cable specification| Read only| 16-bit integer|
143| RCMU status 00 Not selected 01 Normal operation 02 Self-check failed 03 There is leakage in the charging circuit| Read only| 16-bit integer|
144| RFID status 00 not selected 01 IC card not operating 02 IC card closed 03 IC card open| Read only| 16-bit integer|
145| Lock status 00 not selected 01 locked 02 unlocked 03 fault| Read only| 16-bit integer|
146| The current current, the decimal place is determined by the value of the reference current| Read only| 16-bit integer|
147| Current value of charging pile 0-200.0A| Read only| 16-bit integer|
148| Current voltage value of charging pile 0-500.0V| Read only| 16-bit integer|
149| Current power value of charging pile 0-22000W| Read only| 16-bit integer|
150| Calibration value AD value of reference current| Read only| 16-bit integer|
151| The PWM duty cycle corresponding to the current set by the rotary switch| Read only| 16-bit integer|
152| Current output PWM duty cycle| Read only| 16-bit integer|
153-160| spare

22

| Read only| 16-bit integer|

WALLBOX24 ist ein eingetragenes Markenzeichen der HALOGENKAUF LIGHTECH® GMBH.

Customer Service

CLE, plentino, Gaga Lamp, LED-Retroshop und Wallbox24 sind Produktlinien der HALOGENKAUF LIGHTECH® GMBH.
Halogenkauf LIGHTECH GmbH Schlehenweg 4
29690 Schwarmstedt
info@wallbox24.de
www.wallbox24.de

WALLBOX24 Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals