Instruction for use
About the manual
The instructions contain all the information needed for debugging and using the controller. Only the staff with electrical technology can debug the controller.
Validity range of this manual
This manual is valid for all parts of the charging pile controller.
This product is based on international standards IEC61851 and SAEJ1772.
Note: SAEJ1772 is a standard for electric vehicle chargers proposed by
the Society of Automotive Engineers.
Recycle and treatment
The material of the controller has environmental compatibility and can be
recycled.
In order to meet the environmental protection requirements, please contact a
certified professional company that specializes in handling such waste to deal
with electronic waste
Safety Instruction
Precautions and hazards
Note: please follow the safety instructions and legal guidelines.
Due to the different installation requirements in different countries and
regions, the installation personnel are responsible for ensuring that the
product installation can meet the local legal requirements.
Danger: voltage hazard
Contact with live components will cause serious injury. Please cut off the
power supply of all systems and devices before operation.
Fuse
Warning: improper fusing may cause heat or fire The internal self- resetting fuse is only used to protect the controller, and the installation personnel are responsible for the safety of the circuit.
Repair
It is not allowed to repair, and the defective device shall be disposed
(abandoned) under the condition of meeting the environmental protection
requirements.
Warning: opening the device without permission can cause danger
Opening the device without permission may cause harm to the user or cause
significant damage or property loss.
Note: if the device is changed in violation of regulations, the
manufacturer’s warranty will be invalid. Any unauthorized changes will void
the warranty.
Description
Controller Features
The controller is a kind of product suitable for charging pile of electric vehicle.
(1) Software correction instructions, such as EKEPC1 or EKEPC2
(2) Maximum charging capacity indication 10A, 16A, 20A, 25A, 32A, Through
the internal dial switch (The factory default setting is 32A).
(3) “C” for the cable version and” S” for the socket (without cable)
version
Select controller additional functions: Switch the DIP switch to “ON” which corresponding to the functions you need The functions of the corresponding positions are described as follows: In the “ON” position
- Socket version working mode
- Added RCMU(DC6mA) module function
- Function with IC card
- With electronic lock function
- DBL current balance working mode
External can connection LCD mode The functions of the corresponding positions are described as follows: In the “OFF” position
1: Cable version working mode
2: None RCMU(DC6mA) function
3: Lost(without) IC card working mode
4: Without electronic lock function
5: Normal working mode
6: External can connection LCD
External can connection LCD
Scope of use
The communication to control the charging procedure of electric vehicle
conforms to electric vehicle
standard IEC61851 or SAEJ1772.
According to DIN EN60715 installation requirements.
The output of the relay is used to connect the switching load contactor.
The operation status of vehicle interface is displayed by LED.
The controller can be connected to the following external functions:
contactless IC card connection module, DC leakage detection module (rcmu),
RS485 communication
interface equipment, gun head lock device (DC12V), external emergency stop
button. These functions need to be explained when ordering
Application cases
The following is a schematic diagram of an application case.
For example, item C with 1 pcs type B circuit breaker and 1 pcs contactor;
item A、B with 1pcs typ A circuit breaker plus RCMU module and 1 contactor.
Application cases
Function description
Charging process of controller with cable type (only CP signal is needed) After switching on the working voltage, the module starts to initialize and perform the function self test (LED light flashes circularly), waiting for the car to connect. The controller waits for the charging cable to connect to the vehicle (status a), and the LED flashes blue continuously. If the cable matching with the controller has been connected (state B), the LED turns to stable blue light and turns on the electromagnetic lock switch. After the gun head interlock, if the vehicle is in State C, the controller will make P1/ P2 in closed state (connected state), and the LED will turn to stable green light. If status D (ventilation required) is displayed, because the controller has no heat dissipation function, the controller makes P1 / P2 in the open state (off state) and turns off the electromagnetic lock switch at the same time, the gun head interlock will be invalid, and the controller will turn off the charging procedure, and the LED will turn into a stable red light
Function description
Charging process of controller without cable type(socket type)(connecting CP
and CS signals)
Before the power is turned on, the CS signal port of the controller can not be
connected to any device ,after the working voltage is turned on, the module
starts to initialize and perform function self-test (LED lights flash
circularly), waiting for the connection of the car cable, this lights flash
circularly), waiting for the connection of the car cable, this process takes
about 10 s.e. The controller waits for the charging cable to connect to the
vehicle (status A), and the LED flashes blue continuously. If the cable
matching with the controller has been connected (state B), the LED turns to
stable blue light and turns on the electromagnetic lock switch(if have). After
the gun head interlock(if have), if the vehicle is in State C, the controller
will make P1 / P2 in closed state (connected state), and the LED will turn to
stable green light. If status D (ventilation required) is displayed, because
the controller has no heat dissipation function, the controller makes P1 / P2
in the open state (off state) and turns off the electromagnetic lock switch(if
have) at the same time, the gun head interlock will be invalid, and the
controller will turn off the charging procedure, and the LED will turn into a
stable red light. In E and f States, the LED will not be on again when the
electromagnetic lock switch is off and the controller turns off the charging
procedure.
In the fault state, the controller turns P1 / P2 on (off) and turns off the
electromagnetic lock switch. The LED turns red and flashes continuously.
Ventilation requirements
In the absence of ventilation, the risk of asphyxiation may be caused due to
the accumulation of some battery related gases when charging indoor. If the
charging process is carried out indoor, forced ventilation shall be installed,
the charging pile controller does not have forced ventilation function.
Connection confirmation line (CS) current, resistance correspondence
information. current resistance/ current resistance/ current resistance /
current resistance/ current resistance 32A 732Ω / 25A 536Ω / 20A 432Ω / 16A
348Ω / 10A 249Ω When the input resistance (minimum) is lower than 100Ω, it
cannot be charged or interlocked. The controller will reduce the current load
to 7a within 5S, and the controller will enter Status A until the resistance
value of the input current rises.
LED display and troubleshooting
LED Display
There are three colors of display, the specific working status and functions
are as follows:
Controller connection status
on
No.
| State Code| LED Color| LED State| PE、CP、PP state| Controller state| Remark
Power self-check failed!
---|---|---|---|---|---|---
0| K| Red| 5Hz flashing| Power self detect failed| Fault–1#| Please turn the
power back on!
1| A| Blue| 1Hz flashing| CP disconnection| Ready|
2| I| Blue| 2Hz flashing| Waiting for IC card| RFID Waiting|
3| B| Blue| Stabilization| CP connect to diode+2.7KΩ| Connected|
4| B| Blue| Stabilization| CP connect to diode+1.3KΩ| Connected|
5| C| Green| Green brightening| CP connect to diode+2.7KΩ
parallelconnect1.3KΩ| Charging|
6| D| Red| Stabilization| CP connect to diode+2.7KΩparallelconnect1.3KΩ
parallel connect 270R Or CP connect to
diode+270R Or CP connect to diode+270R parallel connect 2.7KΩ Or CP connect
to diode+270R parallel connect 1.3KΩ| Fault–2#| Need Ventilation! PClP- PE
short ctihrcuit!
7| F| Red| 1Hz flashing| CP line short circuit with PE line| Fault–3#| ease
check e CP line
8| H| Red| 5 Hz flashing| RCMU occurs residual current or self detect failed|
Fault–4#| sReClMf-iUnslepaekcatgioenofrailure
9| E| Red| 2Hz flashing| Diode short circuit
(Requirement waiting the CP disconnected)
| Fault–5#| EV-Charing Socket Fault PSPLIsT PP wciret,
10| G| Blue+Red| 2Hz flashing| PP line disconnection| Fault–6#| lea e che k he
PP line
11| J| Red+Green+Blue| 2Hz flashing| Electromagnetic Lock failed| Fault–7#|
Electronic Lock Disabled
12| L| Blue| 5Hz flashing| IC card failed| Fault–8#| RFID card is not valid
DCirBcuit ovearcloiad,
13| M| Red+Green| 1Hz flashing| Circuit overload,DLB Mode activated 11| Fault–9#| L Mode t vated
Installation
Installing to DIN rail
- Install the controller (a) vertically on the horizontal DIN rail (b).
- Rotate the device down until the slider on the DIN rail snaps in.
(Note: DIN rail: rail in accordance with German industrial standards)
Wiring
Warning: improper (connection) fuses can cause heat or fire.
The internal self-reset fuse is designed only for the protecting device
itself, and it is the responsibility of the controller’ S user or factory
operator to protect the circuit related to the control. This device does not
include the contactor of load output. Improper use of the contactor of load
output will cause heat or fire when the line is overloaded. The contactor of
load output is installed from outside by the factory operator.
Warning: through the controlling signal, the maximum charging current borne by
the vehicle shall not exceed the maximum charging current specified by the EPC
controller, otherwise personal injury or property loss will be caused.
Notice
L/N is connected to the main board’ s line.
5.1 Connecting terminal blocks and terminal assignment
“C: with cable version”means that the charging cable is permanently connected
to the controller; P1 / P2 terminal is connected to the AC contactor providing
the charging load. The rated value of Curve B circuit breaker shall be
selected within the maximum current range circuit breaker shall be selected
within the maximum current range.
Notice
When selecting the cable, its temperature resistance needs to be at least 75°C. If the temperature resistance fails to meet the requirements, personal injury or property loss will be caused. Warning: The conductor sections should be designed to conform to the standard system construction. The cable must conform to the type of line, otherwise it will cause personal injury or property loss.
Terminals arragemnet specification
Terminal function specification
Serial
number| Mark| function| Specification
---|---|---|---
| L| Live line| Product working power supply:AC230V±10% 50Hz
2| N| Neutral line
3| P1| Relay coil A1|
AC contactor connected to the connection load of charging station
4| P2| Relay coil A2
5| FB| Reflect signal of the
electromagnetic lock| This is the feeback signal on the electromagnetic lock
directly to the passive contact output terminal of the electromagnetic lock
6| FB
7| LK+| Electromagnetic lock positive voltage| Provide positive and negative
pulse voltage of electromagnetic lock, duty cycle of output pulse (1: 3) and
total pulse output maximum driving capacity of 500ms
8| LK-| Electromagnetic lock negative voltage
9| 0V| Earth terminal| External indicator light, DC5V/10mA drive capability
10| RED| Red LED
11| GRE| Blue LED
12| BLU| Green LED
13| IC| IC card – controlled input signal| The signal of external non-contact
IC card reading module, input is TTL voltage signal,DC 3.3V/
5.2 AC 230V
Wiring example 230V AC
Wiring instructions
Controller signal line P1 : Blue 2.5 mm2
Controller signal line N : Blue 2.5 mm2
Contactor coiling opening and closing line N : Blue 2.5 mm2
Power output line N: Blue 4mm2
Continuous output line N: 2.5 mm2
Contactor coiling opening and closing line L: Brown 2.5 mm2
Controller signal line L : Brown 2.5 mm2
Continuous output line L: 2.5 mm2
Power output line L: 4 mm2 WAGO 1 WAGO 2 Curve B RCCB Controller
Contactor Terminal blocks Input line Input line of charging plug Two colors
signal grounding wire 2.5 mm2 Black signal wire 0.5 mm2
Brown outgoing line L: 6 mm2
Blue outgoing line N: 6 mm2
Two colors grounding wire: 6 mm2
Functional grounding Vehicle interface shall conform to IEC61851
- Connect“CP”directly to the interface of vehicle charging terminal.
- Firstly connect the ground wire (PE line) of the vehicle charging terminal interface to the OV control point of the EPC controller, and then connect other lines in order. Do not use terminal blocks or EPC controller to connect the device from the outside at OV control point.
OV control point shall be consiste nt with the expected current of the factory. The connection of EPC controller to OV is functional grounding, and the reliability of connection must be guaranteed,otherwise personal injury or property loss will be caused.
Relay output
We recommend connection with 230 / 400V 10kA curve B RCCB. Cutting off the
power branchAccording to IEC61851, it is required to cut off the power branch
when the charging process is completed within 100ms.
The EPC controller will stop the relay output after detecting that the power
branch is cut off.
Warning: To cut off the power branch, especially the contactor, the total
power-off time shall not exceed the required 100ms.
Replacement device
Maintenance
EPC charging controller is maintenance free.
Warning: There is no replaceable fuse inside EPC When replacing, make
sure that the device and the components associated with the device are not
energized.
Danger: Voltage hazard Touching any running parts will cause serious
injury. Please cut off the power before operation.
Process
- Cut off the line from the EPC controller terminal.
- Pull the latch down from the back of the unit and rotate until it is free of the DIN rail and removed.
- Installation: connect the rear lock clipper to the DIN rail and swing until the lock clipper was put in.
- Reconnect the line (On).
- Turn on the switch and the main power.Cleaning Cleaning of the unit is not allowed
Dimensional drawings(mm)
RS485 Communication description
Modbus-RTUmodel , Baud rate: 38400, fixed , address: 1-255 default : 255( Broadcast address )
Register address number| Data description (power failure protection)| Read and
write| Type of data| Defaults
---|---|---|---|---
100| Device address number| Read and write| 16-bit integer| 255
101| DLB maximum starting current| Read and write| 16-bit integer| 9000
102| DLB maximum current (100.00A)| Read and write| 16-bit integer| 10000
103| Reference current: DLB/current transformation ratio (100.00A)| Read and
write| 16-bit integer| 10000
104| Reference current calibration value input| Read and write| 16-bit
integer| 1270
105| Charging pile current transformation ratio 50-200A| Read and write|
16-bit integer|
106| Charging pile current value correction 0-100.0A| Read and write| 16-bit
integer|
107| Charging pile voltage value correction 0-500.0V| Read and write| 16-bit
integer|
108| Charging pile power value correction 0-22000W| Read and write| 16-bit
integer|
109| Maximum output PWM duty cycle of charging pile| Read and write| 16-bit
integer| 90%
110| RCMU function selection 0 disabled 1 enabled, other values are selected
by DIP switch| Read and write| 16-bit integer| 3
111| RFID function selection 0 disabled 1 enabled, other values are selected
by DIP switch| Read and write| 16-bit integer| 3
112| Lock function selection 0 disabled 1 enabled, other values are selected
by DIP switch| Read and write| 16-bit integer| 3
113| Cable function version selection 0 disable 1 enable, other values are
selected by DIP switch| Read and write| 16-bit integer| 3
114| DLB function selection 0 disable 1 enable, other values are selected by
DIP switch| Read and write| 16-bit integer| 130
0
115| PID control parameter P of DLB| Read and write| 16-bit integer| 1
116| PID control parameters of DLB I| Read and write| 16-bit integer| 100
117| DLB PID control parameter D| Read and write| 16-bit integer|
118-119| Controller ID number up to 9 digits| Read and write| 32-bit integer|
120-139| spare| Read and write| 16-bit integer| 1002
140| Software version| Read only| |
141| Current working status: Corresponding status 0-13| Read only| 16-bit
integer|
142| PWM value of cable specification| Read only| 16-bit integer|
143| RCMU status 00 Not selected 01 Normal operation 02 Self-check failed 03
There is leakage in the charging circuit| Read only| 16-bit integer|
144| RFID status 00 not selected 01 IC card not operating 02 IC card closed 03
IC card open| Read only| 16-bit integer|
145| Lock status 00 not selected 01 locked 02 unlocked 03 fault| Read only|
16-bit integer|
146| The current current, the decimal place is determined by the value of the
reference current| Read only| 16-bit integer|
147| Current value of charging pile 0-200.0A| Read only| 16-bit integer|
148| Current voltage value of charging pile 0-500.0V| Read only| 16-bit
integer|
149| Current power value of charging pile 0-22000W| Read only| 16-bit integer|
150| Calibration value AD value of reference current| Read only| 16-bit
integer|
151| The PWM duty cycle corresponding to the current set by the rotary switch|
Read only| 16-bit integer|
152| Current output PWM duty cycle| Read only| 16-bit integer|
153-160| spare
22
| Read only| 16-bit integer|
WALLBOX24 ist ein eingetragenes Markenzeichen der HALOGENKAUF LIGHTECH® GMBH.
Customer Service
CLE, plentino, Gaga Lamp, LED-Retroshop und Wallbox24 sind Produktlinien der
HALOGENKAUF LIGHTECH® GMBH.
Halogenkauf LIGHTECH GmbH Schlehenweg 4
29690 Schwarmstedt
info@wallbox24.de
www.wallbox24.de
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>