QUICK 959D+ SMD Rework Station Instruction Manual

June 11, 2024
QUICK

QUICK 959D+ SMD Rework Station

QUICK 959D+ SMD Rework Station

Thank you for purchasing our products. Please keep the instruction manual properly for future reference.

Safety Instruction

  • During the installation and use of the product, you need to observe the electrical
    safety regulation of location.

  • Please power off the product during disassembly.

  • If the product is not working properly, please contact the supplier or manufacture, do not disassemble or modify without notice. We will not be liable for any problems caused by unauthorized maintenance or modification of the product.

WARNING

  • Products should be used away from magnetic field.
  • Do not place the product where the surface is vibrated or subject to shocks.
  • Do not install the product where it maybe wet.
  • Do not use the product near flammable materials.
  • The product should be keep ventilation during operation. Turn off the product when resting or after completion..
  • Do not use the product when it is damaged, inspection and maintenance regularly.
  • The handle is placed on the holder, the system will sleep automatically when the temperature is less than 100 ℃.
  • Please unplug the power cable when the product is not used for a longtime.

Product Introduction

This product is suitable for de-soldering and soldering, such as SMD, SOP, SOG. Heat shrinkage, drying, paint removal, adhesive removal, thawing, preheating & disinfection are available. Adjustable air volume is suitable for small or large air volume heater.

Product Features

  • Closed loop sensor, microcomputer control temperature, with high power and rapid temperature heat.
  • Air volume adjustable, digital display and easy to adjust temperature.
  • There is a magnetic sensor in handle. The handle is placed on the holder, the system will sleep automatically. And when picked up from holder, it will enter work mode quickly.
  • Cooling fan extends heater lifetime.
  • Compact design.

Product Specifications

Product type

|

959D+

---|---

Display

| LCD
Power| 500W(Max)|

580W(Max)

**** Input voltage

| 110V AC| 220V AC
Temperature range|

100~500℃

**** Air volume

| 1~100 Level (Adjustable)
**** Airflow|

**** 40L/min (Max)

Dimensions(LWH)

| *** 110180*151mm
Weight|

About 1.6 Kg

Function Descriptions

Dimensions

Dimensions

Part Descriptions

Part Descriptions

Button Descriptions

Button

|

Function Descriptions

---|---
**** CH1~CH3|

  1. Click coordinate button to select Channel numbers.
  2. Press and hold the Channel button to store the airflow and temperature of the current Channel.

**** ▲/▼|

  1. Temperature regulation
  2. Press and hold ▲&▼ buttons simultaneously to enter the temperature calibration menu.
Main Menu

Main Menu

**Icon**

|

**Descriptions**

---|---
****|

**** Air volume

**** CH0

|

**** Temporary channel

**** COOL

|

**** Cooling status

Installation and Connection

Installation

The handle holder must be installed when the product is used for the first time, as shown below.

  1. Remove two screws on the left side of the holder.
  2. Place the mounting hole of the handle holder on the two screw holes on the product and install two screws and tighten them.
  3. Install the handle holder and put the handle on the holder, then check whether they are well fit.

Installation

Note: The handle holder can be installed on the left or right side of the product according to actual needs.

Connection

Connect the AC power supply, and power on it to start work.

Operation

Air volume

Adjust the knob clockwise to increase air volume, and otherwise to decrease do reverse operations and the air volume will be decreased. Adjust the knob for a large scope and the air volume can be quickly increased or decreased.

Temperature

Click the “▲” or “▼” button to increase or decrease the temperature by1℃, and hold down the “▲” or “▼” button to rapidly increase or decrease the temperature.

Channel

Click CH1, CH2, CH3 to select Channel 1, Channel 2, Channel 3 respectively. Long press the Channel button to store the parameters of the current Channel.

Sleeping

Place the handle on the holder to cool. The station will enter the sleeping mode when the temperature is less than 100℃.

Operation

Password Setup

The initial password is “000”. The temperature can be set under this state. If you want to limit temperature adjustment, the password must be changed.

Enter password setting mode

  1. Turn off the station press the “▲” and “▼” keys at the same time, and then turn on the station.
  2. Press the “▲” and “▼” keys, and you will hear a sound “Di” before Cis displayed ,then a symbol “–” appears.
  3. Enter the right password to enter the parameter setting menu.

Enter the initial password

  1. The window displays “–” and the left hundred-digit flashes. At this time, the hundred-digit number can be adjusted (you can enter the initial password).
  2. Input the initial password: Adjust the middle knob to change the hundred-digit number; press “▲” key to move the digits and then ten-digit number began to flash, indicating that it can be set in the same way as before. After the single-digit number is set, hold down the“▲” and “▼” keys at the same time to confirm it.
  3. If the first password is wrong: then directly enter the second password, andthe input method is same as the first time. (There are two chances of password input. If the first password input is wrong, you can directly enter the second input.)
  4. If the password entered twice is wrong: the window will show “ERR”, and then directly enter the main interface.
  5. If the first or the second password is correct: then directly enter the parameter settings, and the window shows “-1-”.

Parameter Setup

  1. The password is entered correctly to access the parameter menu, and the sequence of changes is shown in the following figure.
    Parameter Setup

  2. Click “▲” or “▼” button, select parameter menu-1, and return to the main interface directly; after selecting parameter menu-2, press “▲” and “▼” buttons at the same time to enter the new password setting.

New Password Setup

  1. After entering the new password setting, the window displays “—” and the hundreds’ digit blinks.
  2. Then adjust the middle knob to change the hundreds’ digit, press the “▲” button to move the digit, and then the tens’ digit starts flashing to be set. When the digit is set,  press and hold the “▲” and “▼” button at the same time to confirm. The second setting method of password is the same as the first setting method of password.

Note: If the numbers of the password entered twice before and after are not the same, the window shows “ERR”, indicating that the password setting is not successful. Return to the parameter setting, and the password remains unchanged.
If the same number is entered twice, the window will show “OK”, which means the password is set successfully and return to the parameter setting. Turn off and restart the product, and the password will take effect.

Temperature Calibration

  1. Set the product temperature to 300℃. Use QUICK196 to test the temperature of the air outlet and write down the readings.
  2. Press and hold the “▲”and “▼” button about 2s, the display will show “CAL” and enter the temperature calibration mode.
  3. Press “▲” or “▼” to adjust the temperature to the measured value.
  4. Press and hold the “▲” and “▼” button about 2s, and return to the main interface with a beep. That is, the temperature calibration is successful.Temperature Calibration

Note: If there is no QUICK196, it is recommended that the temperature measuring head of the external sensor of the thermometer be placed 3~5mmaway from the nozzle for temperature test.

Replacement of the Heater

Replacement of the Heater

Steps of removing the Heater
  1. Remove the spring.
  2. Unscrew the three Screws .
  3. Pull out Steel pipe & Holder from Handle.
  4. Remove the orange and yellow cables connected in the Heater.
  5. Remove a screw of Steel pipe, plug the grounding cable and remove the Steel pipe. Check whether the quartz tube is damaged or not.
  6. Remove the Heater from Plug.
  7. Remove the heater

NOTE: :The steps need to be operated in the OFF status, and the handle should be cooled in the room temperature.

Steps of replacing the Heater
  1. Insert the Heater, and connect it into green plug.

  2. Connect the yellow cable into the heater of the yellow cable , and the orange into the red.

  3. Connect the Plug into Holder, then cover the Heater with the ②Steel pipe and lock it.

  4. Connect grounding cable and tighten it.

  5. Install the replaced Heater into the Handle, lock the three Screws.

  6. Turn the spring counterclockwise until the handle is installed.

  7. After replacing the heater, test the following parameters:
    Steps of replacing the Heater

  8. Calibrate the temperature, refer to Soldering temperature calibration.

Troubleshooting

No.

| Error Message|

Fault Descriptions

---|---|---

**** 1

| **** H-E|

Indicates that there is a problem with the heater and the heater needs to be checked or replaced.

**** 2

| **** S-E|

Indicates that there is a problem with the sensor and the sensor needs to be checked or replaced.

**** 3

| **** ERR|

**** Indicates that the fan is faulty and needs to be checked or replaced.

Nozzles

Nozzles

Consumable List

**** Nozzle

| A1124
---|---

A1130

A1300

**** Heater|

**** A1147-(220V)

Steel pipe

| 857
Mica paper|

857/74x18mm

**** ceramic packing

| /
Handle|

**** 857

Holder

| 957D+
The handle sheath|

/

**** Fuse

| **** 3A/5x20mm/40003228
Pump components|

/

Fan module

| 959D+
Sucking pad|

/

LOGO

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>