KARCHER BP 4.500 Garden Booster Pump Instruction Manual
- June 11, 2024
- Karcher
Table of Contents
- BP 4.500 Garden Booster Pump
- General notes
- Environmental protection
- Accessories and spare parts
- Startup
- Operation
- Care and maintenance
- Troubleshooting guide
- Specifications
- **Declaration of Conformity
- Optional Special Accessory
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BP 4.500 Garden Booster Pump
Instruction Manual
BP 4.500 Garden Booster Pump
Register your product
www.kaercher.com/welcame
General notes
Read these original operating instructions and the enclosed safety
instructions before using the device for the first time. Proceed accordingly.
Keep both books for future reference or for future owners.
Intended use
Please observe the requirements of EN 1717 when con- necting this product to
the drinking water network and contact your sanitation specialists if you have
any questions. This device has been developed for private use and is not
intended for the load imposed by commercial use. The device is primarily
intended for use in the garden and provides constant pressure for garden
watering. When connecting sprinklers, a maximum of the following areas can be
irrigated:
- BP 4.500 Garden: 400 m²
- BP 5.000 Garden: 550 m²
- BP 6.000 Garden: 900 m²
- BP 7.000 Garden: 1000 m²
CAUTION
Risk of injury! Risk of injury from toxic substances. Do not drink water that
has been pumped by the pump! Permissible feed fluids Permissible feed fluids:
- Processed water
- Well water
- Spring water
- Rain water
- Swimming pool water with intended dosage of additives The temperature of the delivered liquid must not exceed 35 °C.
Improper use
Note
The manufacturer accepts no liability for possible damage caused by improper
use or incorrect operation.
Hazard levels
DANGER
-
Indication of an imminent threat of danger that will lead to severe injuries or even death.
WARNING -
Indication of a potentially dangerous situation that may lead to severe injuries or even death.
CAUTION -
Indication of a potentially dangerous situation that may lead to minor injuries.
ATTENTION -
Indication of a potentially dangerous situation that may lead to damage to property.
Environmental protection
The packing materials can be recycled. Please dispose of packaging in
accordance with the environmental regulations.
Electrical and electronic appliances contain valuable, recyclable
materials and often components such as batteries, rechargeable batteries or
oil, which – if handled or disposed of incorrectly – can pose a potential
threat to human health and the environment. However, these components are
required for the correct operation of the appliance. Appliances marked by this
symbol are not allowed to be disposed of together with the household rubbish.
Notes on the content materials (REACH)
Current information on content materials can be found at:
www.kaercher.com/REACH
Accessories and spare parts
Only use original accessories and original spare parts. They ensure that the
appliance will run fault-free and safely. Information on accessories and spare
parts can be found at www.kaercher.com.
Scope of delivery
The scope of delivery for the appliance is shown on the packaging. Check the
contents for completeness when unpacking. If any accessories are missing or in
the event of any shipping damage, please notify your dealer.
Warranty
The warranty conditions issued by our sales company responsible apply in all
countries. We shall remedy possible malfunctions on your device within the
warranty period free of cost, provided that a material or manufacturing defect
is the cause. In a warranty case, please contact your dealer (with the
purchase receipt) or the next authorised customer service site. (See overleaf
for the address)
Description of the device
The maximum amount of equipment is described in hose operating instructions.
Depending on the model used, there are differences in the scope of delivery
(see packaging).
For the illustrations, refer to the graphics page
Illustration A
- Cap, 2-way connection adapter 2
- way connection adapter for pumps G 1 (not included with BP 4.500 Garden)
- Connection adapter for pumps G 1 (included twice with BP 4.500 Garden)
- Sealing plug
- Connection G 1 (33.3 mm) suction line (inlet)
- Filling nozzle with cap
- Connection G 1 (33.3 mm) pressure line (outlet)
- ON/OFF switch
- Water drain valve
- **Tap connection G 1
- **Coupling with Aqua Stop
- **Coupling
- **Syringe
- *Suction hose set incl. 3.5 m ready-to-connect, vacuum-proof spiral hose with suction filter and backflow stop
- **Garden hose 1/2″ 20 m
- Power supply cable with plug * Only accessories included with Set and Set Plus. ** Only accessories included with Set Plus.
Startup
We recommend using only original Kärcher suction hoses, filter components and hose connections. Using components from other manufacturers can lead to malfunctions when sucking the feed fluid, especially when using bayonet connection systems. Before initial startup Preparation
-
Remove the sealing plug.
-
Screw the connection adapter into the suction connection of the pump (inlet). Manually tighten.
-
Connect a vacuum-tight suction hose Illustration B Note If the water is dirty, we recommend fitting a pre-filter (see Special accessories) between the check valve and the suction hose.
Illustration
Note To shorten the re-suction time, use a suction hose with backflow stop. This prevents the suction hose from emptying after use (see Special accessories). -
Screw the connection adapter into the pressure connection of the pump (outlet). Manually tighten. Illustration D
-
Open the filling nozzle cap. Illustration E
-
Fill the pump with water until it overflows. Illustration F
Operation
-
Plug the mains plug into a mains socket.
-
Switch the device on with the ON/OFF switch.
-
To shorten the suction time, raise the pressure hose approx. 1 m. Illustration I
-
Wait until the pump simultaneously sucks and delivers.
CAUTION Danger due to dry running Dry running damages the pump. Do not let the pump run dry! -
Do not leave the pump unattended during operation.
ATTENTION Risk of injury. The system is pressurized! Risk of injury. (for pressure see chapter “Technical data”)
Ending operation
1. Switch off the device at the ON/OFF switch. 2. Pull the mains plug out of
the socket.
Care and maintenance
DANGER
Danger of electric shock. Always switch the device off and disconnect the
mains plug before working on the device. The device is maintenance-free.
Rinse
Note Rinse the pump with clear water after each use when pumping water
with additives.
Transport
CAUTION
Risk of injury
Risk of injury from falling device.
When transporting the device, observe the weight of the device (see chapter
Specifications) and secure it accordingly when transporting it in vehicles.
Manual transport
- Roll up the cable.
- Lift and carry the device by the carrying handle.
Transport in vehicles
- Secure the device against slipping and tipping over.
CAUTION
Risk of injury
Risk of injury from falling device.
When transporting the device, observe the weight of the device (see technical
data) and secure it accordingly when transporting it in vehicles.
Storage
CAUTION Risk of injury and damage! The device may tip over on sloping
surfaces. Be aware of the weight of the device during storage.
- Store the device in a frost-protected place.
Storing the device
- Depressurize the device by opening the water removal connected to the pressure side (e.g. opening the garden sprayer).
- Empty the hoses.
- Remove suction line and pressure line.
- Drain the pump via the water drain valve. Illustration H
- Store the device in a frost-protected place.
Special accessories
You will find the possible special accessories on the last page of these
operating instructions.
Troubleshooting guide
Malfunctions often have simple causes that you can remedy yourself using the following overview. When in doubt, or in the case of malfunctions not mentioned here, please contact your authori sed Customer Service.
Fault | Cause | Rectification |
---|---|---|
Pump is running, but not delivering | Air is in the pump. | 1. Check for |
correct startup (see chapter Preparation and Operation).
Dirt particles block the suction area.| 1.Pull the mains plug out of the
socket.
2.Clean the suction area.
The suction hose or the connection adapter is not correctly screwed in.|
1.Check that the seals are fitted correctly.
2.Manually tighten the suction hose and connection adapter.
The pre-filter is clogged.| 1. Clean the pre-filter.
The pump does not start up, or stops suddenly during operation| The power
supply is disconnected.| 1. Check the fuses and the electrical connections.
The pump capacity drops or is too low| The suction area is clogged.| 1.Pull
the mains plug out of the socket.
2.Clean the suction area.
The delivery rate of the pump depends on the delivery head and the connected
periphery.| 1. Observe the max. delivery head (see chapter Specifications),
select a different hose diameter or a different hose length if necessary.
The cross-section on the pressure side is narrowed, e.g. due to the valve/ball
tap not being fully open.| 1. Open the valve/ball tap completely.
The hose is kinked on the pressure side.| 1. Eliminate the kink points in the
hose.
The pre-filter is clogged.| 1. Clean the pre-filter.
Specifications
BP 4.500 Garden | BP 5.000 Garden | BP 6.000 Garden | BP 7.000 Garden |
---|---|---|---|
BP 4.500 Garden Set Plus | BP 5.000 Garden Set Plus | BP 6.000 Garden Set Plus | |
Mains voltage | V | 230-240 | 230-240 |
--- | --- | --- | --- |
Power frequency | Hz | 50 | 50 |
Nominal power | W | 550 | 650 |
Maximum flow rate | l/h | 4500 | 5000 |
Suction height (max.) | m | 8 | 8 |
Pressure (max.) | MPa (bar) | 0,36 (3,6) | 0,40 (4,0) |
Delivery height (max.) | m | 35 | 40 |
Delivery temperature (max.) | °C | 35,0 | 35,0 |
Particle size (max.) of permissible feed fluids | 1 | 1 | |
Pump type | Jet | Jet | |
Sound pressure level LpA | dB(A) | 56 | 58 |
--- | --- | --- | --- |
Guaranteed sound power level LWA | dB(A) | 71 | 73 |
Dimensions and weights | |||
--- | --- | --- | --- |
Weight (without accessories) | kg | 6,4 | 7,0 |
Note
Reason for exception according to regulation (EU)
2019/1781 Annex I Section 2 (12): (j) Subject to technical modifications!
Characteristic curves
**Declaration of Conformity
**
EU Declaration of Conformity
We hereby declare that the machine described below complies with the relevant
basic safety and health requirements in the EU Directives, both in its basic
design and construction as well as in the version placed in circulation by us.
This declaration is invalidated by any changes made to the machine that are
not approved by us.
Product: Pump Type: 1.645-xxx
Currently applicable EU Directives
2006/42/EC (+2009/127/EC)
2014/30/EU
2000/14/EC
2011/65/EU
2009/125/EC
Commission Regulation(s)
(EU) 2019/1781
Harmonised standards used
EN 60335-1
EN 60335-2-41
EN 62233: 2008
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 1997+A1: 2001+A2: 2008
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN IEC 63000: 2018
Conformity evaluation procedure used
2000/14/EC: Annex V
Sound power level dB(A)
BP 4.500 Garden
Measured: 68
Guaranteed: 71 BP 5.000 Garden
Measured: 70
Guaranteed: 73 BP 6.000 Garden
Measured: 81
Guaranteed: 84 BP 7.000 Garden
Measured: 81
Guaranteed: 83
The signatories act on behalf of and with the authority of the company
management.
Documentation supervisor: S. Reiser
Alfred Kircher SE & Co. KG
Alfred-Kircher-Str. 28 – 40 71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2021/06/01
Declaration of Conformity (UK)
We hereby declare that the product described below complies with the relevant
provisions of the following UK Regulations, both in its basic design and
construction as well as in the version put into circulation by us. This
declaration shall cease to be valid if the product is modified without our
prior approval. Product: Pump Type: 1.645-xxx
Currently applicable UK Regulations
S.I. 2008/1597 (as amended)
S.I. 2016/1091 (as amended)
S.I. 2001/1701 (as amended)
S.I. 2012/3032 (as amended)
S.I. 2010/2617 (as amended)
Commission Regulation(s)
(EU) 2019/1781
Designated standards used
EN 60335-1
EN 60335-2-41
EN 62233: 2008
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 1997+A1: 2001+A2: 2008
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN IEC 63000: 2018
Applied conformity assessment procedure
S.I. 2001/1701 (as amended): Schedule 8
Sound power level dB(A)
BP 4.500 Garden
Measured: 68
Guaranteed: 71 BP 5.000 Garden
Measured: 70
Guaranteed: 73 BP 6.000 Garden
Measured: 81
Guaranteed: 84 BP 7.000 Garden
Measured: 81
Guaranteed: 83
The signatories act on behalf of and with the authority of the company
management.
Documentation supervisor: S. Reiser
Alfred Kircher SE & Co. KG
Alfred-Kircher-Str. 28 – 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2021/06/01
Optional Special Accessory
THANK YOU!
MERCI! DANKE! GRACIAS!
Register your product and benefit from many advantages.
www.kaercher.com/welcome
Rate your product and tell us your opinion.
www.kaercher.com/dealersearch
Alfred
Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28-40
71364 Winnenden (Germany)
Tel.: +49 7195 14-0
Fax: +49 7195 14-2212http://kaer.ch/er/?l=TwSoJtl9IUOwZyAe1rHDyw
References
- Cher - Official Site
- Cleaning equipment and pressure washers | Kärcher International
- Cleaning equipment and pressure washers | Kärcher International
- Dealer Search | Kärcher International
- Home and Garden Warranty Registration USA - Kärcher
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>