DSC HS2016 Power Supply Four High Current Output Modules
HSM2300/2204 v1.1 Installation Instructions
The HSM2300 and HSM2204 are power supply modules that provide additional
current to compatible PowerSeries Neo alarm controllers. The HSM2300 can
provide up to 1.0A of additional current, while the HSM2204 can provide up to
1.0A of additional current and add up to four high-current programmable
outputs. This product meets the requirements of Class II, Grade 2 equipment as
per EN501311:2006+A1:2009, EN50131-3:2009 Type B, and EN50131-6:2008 Type A.
Product Usage Instructions
Before installing the HSM2300 or HSM2204, refer to the Installation Manual of the DSC equipment to which it will be connected or powered from (e.g., alarm controller, power supply, etc.).
Power Requirements
The board shall be powered by a transformer. For installations using the
transformer mounted inside the cabinet, replace the fuse only with the same
type (20mm) rated 250V/315mA. For EU installations, a transformer is required,
mounted in the same enclosure and permanently connected. For UL/ULC
installations, use the plug-in adaptor model PTD1640U(UL) /PTD1640(ULC) or
hardwired model FTC3716. Note that the main control panel and power supply
shall be powered from the same AC mains circuit.
Battery Requirements
For EN50131-6:2008 compliant installations, use only one 12V/7Ah battery
for 12 hours of required standby time (500mA output current). Recharge time to
80% is 72 hours. Supervised for loss of primary power source (AC Fail),
battery fail, or battery low voltage (Battery Trouble) with indication
provided on the keypad. For T014 (INCERT) compliant installations, use two
12V/7Ah batteries for 24 hours of required standby time (500mA output current)
and the enclosure model PowerUC1 (INCERT certified). The charging current
shall be high.
Product Terminal Descriptions
Refer to Table 1 for terminal descriptions and ratings.
Current Draw| Max. Aux Current| UL Resi Fire| UL Home| UL Resi Burg| UL Com
Burg| Health Care| ULC Resi| ULC Fire Monitoring| ULC Resi Burg| Fire| ULC Com
Burg| EN50131 Grade 2/Class II
---|---|---|---|---|---|---|---|---|---|---|---|---
HOLISME/2204| 1A| 1A| 0.5A| 0.5A| 0.5A| N/A| 0.5A| N/A| 0.5A| N/A| N/A| N/A
Note that the HSM2204 is not suitable for fire alarm annunciation.
Power Supply/Four High-Current Output Modules
The HSM2300 can provide up to 1.0A of additional current to the compatible
PowerSeries Neo alarm controllers, models HS2016, HS2032, HS2064, and HS2128.
The HSM2204 can provide up to 1.0A of additional current and add up to four
high-current programmable outputs.
This installation sheet shall be used in conjunction with the Installation Manual of the DSC equipment to which the HSM2300 or HSM2204 is connected or powered (e.g. alarm controller, power supply, etc.).
General
This product meets the requirements of Class II, Grade 2 equipment as per
EN50131- 1:2006+A1:2009, EN50131-3:2009 Type B and EN50131-6:2008 Type A.
Specifications
- Power supply Type A as per EN50131-6 Standard
- Temperature range: – 10°C to + 55°C (14°F to 131°F); for UL/ULC listed installation: 0 to +49°C (32°F to 122°F)
- Relative Humidity: 5% to 93% R.H. non-condensing
- Input rating: EU: 220V- 240Vac, 50Hz, 200mA; NA: 120V, 60Hz, 500mA. Only one board shall be powered by a transformer.
Note:
For installations using the transformer mounted inside the cabinet, replace
the fuse only with the same type (20mm) rated 250V/315mA.
- Transformer required, mounted in the same enclosure and permanently connected (EU); for UL/ULC installations, use the plug-in adaptor model PTD1640U(UL) /PTD1640(ULC) or hardwired model FTC3716.
Note:
For UL/ULC listed installations, do not connect the transformer to the
receptacle controlled by a switch.
- Transformer secondary ratings: 16.5Vac, 40VA
- Board current draw: 40mA (set and unset state/alarm and non-alarm state)
- Board dimensions: 145mm x 83mm
- AUX output ratings: 10.8 to 12.5VDC
- Resettable fuse (PTC) used on circuit board instead of replaceable fuses
- Output ripple voltage: 600mVp-p max.
- No overvoltage protection devices are required on the outputs
- Storage device: rechargeable battery, rated 12Vdc. Replace the battery every 3-5 yrs.
- Battery capacity: 4Ah, 7Ah, or 14Ah (2 x 7Ah) max.
- Maximum standby time 24h (when using 14Ah battery capacity and AUX current limited to 500mA max.) Refer to Table 1.
- Recharging time: up to 85% in 24 hours (use high charging current setting)
- Low battery trouble indication threshold 11.5VDC, restoral level 12.5VDC
- Corbus (RED terminal) low voltage trouble threshold 9VDC
- Battery deep discharge protection (cut-off at 9.6 VDC)
Note:
- Note: Main control panel and power supply shall be powered from the same AC mains circuit.
- Note: For EN50131-6:2008 compliant installations, use only one 12V/7Ah battery for 12h of required standby time (500mA output current). Recharge time to 80% is 72h Supervision for loss of primary power source (AC Fail), battery fail, or battery low voltage (Battery Trouble) with indication provided on the keypad.
- Note: For T014 (INCERT) compliant installations, use two 12V/7Ah batteries for 24H of required standby time (500mA output current) and the enclosure model PowerUC1 (INCERT certified). The charging current shall be high
Terminal Descriptions
Ratings
HOLISME/2204 Current Draw 40mA| UL Resi Burg ULC Resi Burg| UL Com Burg| UL Resi Fire UL Home Health Care ULC Resi
Fire ULC Com Burg
| ULC Fire Monitoring| EN50131 Grade 2/Class II
---|---|---|---|---|---
Max. Aux Current Loading| 1A| 1A| 0.5A| 0.5A| 0.5A
UL/ULC Listed Enclosure| PC500C| CMC-1 PC4050CAR| PC5003C| PC5003C (when used
with a hardwired transformer in an electrical box) PC4050CR (red/transformer
mounted inside)| PC5003C Power UC1
Transformer Requirements| 16.5V, 40VA (plug-in type) PTC1640U (USA) PTC1640CG
(CND)| FTC3716 (cUL listed) 16.5V/37VA (Hardwired type, mounted inside the
enclosure or outside
using the electrical box)
| 16.5V/40VA (hard-wired type, mounted inside the cabinet)
Battery capacity ****
Requirements
| 7Ah| 7Ah| 14Ah (2x7Ah in parallel)| 14Ah (2x7Ah in parallel)| 7Ah
Standby Time| 4 hours| 4 hours| 24 hours| 24 hours| 12 hours
Alarm Time| 4 minutes| 15 minutes| 4 min (UL resi fire) 5 min (Home Health
Care and ULC Resi
Fire)
| 5 minutes (Alarm Trans- mission only)| N/A
Recharging current **** setting| low (480mA)| low (480mA)| high (700mA)| high
(700mA)| low/high (480/700mA)
- AC – Supervised, the HSM2300/HSM2204 requires a 16.5V/40VA transformer. Connect the primary of the transformer to an unswitched AC source (maximum current draw is 0.5A) and connect the secondary of the transformer (US market only) to these terminals.
- TAM- Used to tamper the cabinet in which the HSM2300/HSM2204 is mounted. Connect a normally closed (NC) switch across TAM and BLK. If the tamper is not being used connect a piece of wire across TAM and BLK to remove the trouble condition. Tamper protection is required for UL/ULC commercial/residential burglary installations.
- AUX+ – Used to provide power for devices. Maximum current draw is not to exceed 1000 mA. Connect the positive lead of powered devices to VAUX and the negative to BLK or any COM terminal (01 to 04 for switched output or to BLK for not switched output).
- CORBUS – The 4-wire Corbus connection is used by the panel to communicate with the module. Connect the RED, BLK, YEL, and GRN terminals to the Corbus terminals on the HS2016, HS2032, HS2064, or HS2128 main control.
O1 to O4 (HSM2204) – Wire the positive lead of the device to the AUX terminal and the negative lead to the required output terminal O1 to O4.
IMPORTANT NOTE:
Output O1 is supervised in the same manner as the Bell Output of the
compatible control panel. If O1 is not used, if no continuous load is
connected, or if a siren is connected, a 1000Ω resistor, DSC model EOLR- 1
must be connected in order to prevent the indication of a trouble condition.
This diagram is an example of how to wire various devices to the outputs.
Note: The HSM2204 is not suitable for fire alarm annunciation.
Enclosures
The HSM2300 or HSM2204 shall be installed in the metal enclosures listed below. Tamper protection switches can be installed on all enclosures, including door opening protection and/or removal from the mounting position. Doors shall be secured using screws or a keylock. For EN50131-1 Grade 2 compliant installations, all holes on the side of the cabinets shall be covered (plugged) if no accessories are installed in the cabinet that will use these mounting holes
- Model PC500C made of 22Ga steel, painted. 213mm(L) x 235mm(W) x 78 mm(H)
- Model CMC- 1 made of 18Ga steel, painted. 287mm(L) x 298mm(W) x 80mm(H)
- Model PC4050CAR is made of 18Ga steel, and painted. 376mm(L) x 305mm(W) x 125mm (H)
- Model PC4050CR is made of 18Ga steel, and painted. 376mm(L) x 305mm(W) x 128mm(H)
- Model Power UC1 is made of 18Ga steel, painted. 356mm(L) x 319mm(W) x 115mm(H)
- Weight: 6.15Kg (PCB, Battery, XFRM)
- Model PC5003C is made of 22Ga steel, and painted. 288mm(L) x 298mm(W) x 78mm(H),
- Weight: 4.5Kg (PCB, Battery, XFRM)
Battery Setting
A battery charge current setting in the panel is used to enable high charge current for the battery. Normally the battery charge current can be 240mA max, but when this option is enabled the module can charge the battery with up to 480mA of current. Section [982] [010] Options 1-4 can enable/disable the high current battery charge option for HSM2204 modules 1- 4 and [982] [020] Options 1-4 for the HSM2300.
Status LED
The HSM2300 and HSM2204 are equipped with status LEDs to indicate the current status of the module. If the HSM2300/2204 is operating correctly, the status LED will flash briefly every 10 seconds. When a trouble condition is present, the status LED will display a series of flashes then remain blank for 2 seconds. The number of flashes between blank periods indicates the trouble condition present as outlined in Table 2.
Trouble Conditions
Number of Flashes
|
Trouble Condition
---|---
1| Module not enrolled
2| Panel supervision trouble
3| Corbus low voltage
4| Battery trouble
5| AC trouble
6| AUX trouble
7| Output 1 Trouble – HSM2204 only
Enroll Modules
- Enter Installer Programming [] [8][Installer Code] [].
- Enter section [902] to enroll in the module. Modules can be enrolled automatically or manually. In either case, the serial number of the device is used as an identifier. Select one of the enrollment options described below:
000 Auto Enroll
When this mode is selected, the total number of modules currently enrolled is
displayed on the keypad.
- After entering subsection [000], press the [*] key to begin the auto-enrollment of all new modules. As each device is enrolled, the keypad displays the model type, serial number, and slot assignment. Devices are assigned to the next available slot.
- Use the < > keys to view the enrolled modules.
001 Manual Enroll
- After entering Installer Programming and section [902], enter subsection 001. Then enter [003] for HSM2204 or subsection [009] for HSM2300.
- When prompted, key in the serial number of the module, which is found on the back of the device. An error tone is sounded if an invalid serial number is received. Modules are enrolled into the next available slot for the device.
- To cancel the enrollment of a module, press [#].
Deleting Modules
- Enter Installer Programming [] [8][Installer Code] [].
- Enter section [902] then subsection [109] for HSM2300 and subsection [110] for HSM2204.
- Scroll to the specific module you want to delete.
- Press [] to select the module then, when prompted, press [] again to delete.
Confirming Modules
To confirm enrollment of individual modules and to locate them physically:
- After entering section [903], scroll to the module type you want to confirm (109 for HSM2300, 110 for HSM2204). To view all modules, enter [000] after entering section [903].
- Press [*] to select the module type then scroll to the specific module you want to confirm.
- Press [*] to enter confirmation mode. The module’s serial number and slot number are displayed on the keypad and the status LEDs on the device flash. This continues until confirmation mode for the device is exited via the [#] key.
Limited Warranty
DigitalSecurity Controls (DSC) warrants that for a period of twelve months from the date of purchase, theproduct shall be free of defects in materials and workmanship under normal use and that in fulfillment of any breach of such warranty, DSCshall, at its option, repair or replace the defective equipment upon the return of the equipment to its factory. This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or handling, or damage due to causes beyond the control of DSC such as lightning, excessive voltage, mechanical shock, water damage, or damage arising out of abuse, alteration or improper application of the equipment.
The foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any other warranties, whether expressed or implied, and other obligations or liabilities on the part of DSC. This warranty contains the entire warranty. Digital SecurityControls neither assumes responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. In no event shall DSL be liable for any direct or indirect or consequential damages, loss of anticipated profits, loss of time, or any other losses incurred by the buyer in connection with the purchase, installation or operation, or failure of this product.
Warning:
Digital Security Controls recommends that the entire system be completely
tested on a regular basis. However, despite frequent testing, and due to, but
not limited to, criminal tampering or electrical disruption, it is possible
for this product to fail to perform as expected.
IMPORTANT – READ CAREFULLY:
DSC Software purchased with or without Products and Components is
copyrighted and is purchased under the following license terms:
ThisEnd-User License Agreement (“EULA”) is a legal agreement between You (the
company, individual, or entity who acquired the software and any related
Hardware)and DigitalSecurity Controls, a division of Tyco Safety Products
Canada Ltd.(“DSC”), the manufacturer of the integrated security systems and
the developer of the software and any related products or components
(“HARDWARE”) which You acquired. If the software product (“SOFTWARE PRODUCT”
or “SOFTWARE”) is intended to be accompanied by hardware and is NOT
accompanied by new HARDWARE, You may not use, copy or install the software
PRODUCT. TheSOFTWARE PRODUCT includes computer software and may include
associated media, printed materials, and“online” or electronic documentation.
Any software provided along with the software PRODUCT that is associated with
a separate end-user license agreement is licensed to you under the terms of
that license agreement.
By installing, copying, downloading, storing, accessing, or otherwise using the SOFTWARE PRODUCT, You agree unconditionally to be bound by the terms of this EULA, even if this EULA is deemed to be a modification of any previous arrangement or contract. If you do not agree to the terms of this EULA, DSC is unwilling to license the SOFTWARE PRODUCT to You, and you have no right to use it.
SOFTWARE PRODUCT LICENSE
TheSOFTWARE PRODUCT is protected by copyright laws and international copyright treaties, as well as other intellectual property laws and treaties. The SOFTWARE PRODUCT is licensed, not sold.
-
GRANT OF LICENSE This EULA grants you the following rights:
-
Software Installation and Use – For each license you acquire, You may have only one copy of the SOFTWARE PRODUCT installed.
-
Storage/Network Use- The SOFTWARE PRODUCT may not be installed, accessed, displayed, run, shared, or used concurrently on or from different computers, including a workstation, terminal, or another digital electronic device (“Device”). In other words, if You have several workstations, You will have to acquire a license
for each workstation where the SOFTWARE willbeused. -
Backup Copy- You may make backup copies of the software PRODUCT, but You may only have one copy per license installed at any given time. You may use the
backup copy solely for archival purposes. Except as expressly provided in this EULA, You may not otherwise make copies of theSOFTWARE PRODUCT, including the printed materials accompanying theSOFTWARE.
-
-
DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS
-
Limitations on Reverse Engineering, Decompilation, and Disassembly – You may not reverse engineer, decompile, or disassemble the SOFTWARE PRODUCT, except and only to the extent that such activity is expressly permitted by applicable law notwithstanding this limitation. You may not make any changes or modifications to the software, without the written permission of an officer of DSC. You may not remove any proprietary notices, marks, or labels from the Software Product. You shall institute reasonable measures to ensure compliance with the terms and conditions of this EULA.
-
Separation of Components – TheSOFTWARE PRODUCT is licensed as a single product. Its component parts may not be separated for use on more than one
-
Single INTEGRATED PRODUCT – If You acquired this SOFTWARE with HARDWARE, then the SOFTWARE PRODUCT is licensed with the HARDWARE as a single integrated product. In this case, the software PRODUCT may only be used with the HARDWARE as set forth in this EULA.
-
Rental – You may not rent, lease, or lend the SOFTWARE PRODUCT. You may not make it available to others post it on Onaserver or the website.
-
Software Product Transfer – You may transfer all of Your rights under this EULA only as part of a permanent sale or transfer of the hardware, provided You retain no copies, You transfer all of the SOFTWARE PRODUCT (including all component parts, the media, and printed materials, any upgrades and this EULA), and provided the recipient agrees to the terms of this EULA. If the software PRODUCT is an upgrade, any transfer must also include all prior versions of the SOFTWARE PRODUCT.
-
Termination- Without prejudice to any other rights, DSC may terminate this EULA if You fail to comply with the terms and conditions of this EULA. In such
the event, You must destroy all copies of the SOFTWARE PRODUCT and all of its component parts. -
Trademarks – This EULA does not grant You any rights in connection with any trademarks or service marks of DSC or its suppliers.
-
-
COPYRIGHT – All title and intellectual property rights in and to the SOFTWARE PRODUCT (including but not limited to any images, photographs, and text into-ported into the SOFTWARE PRODUCT), the accompanying printed materials, and any copies of the SOFTWARE PRODUCT, are owned by DSC or its suppliers. You may not copy the printed materials accompanying the SOFTWARE PRODUCT. All title and intellectual property rights in and to the content which may be accessed through the use of the software PRODUCT are the property of the respective content owner and may be protected by applicable copyright or other intellectual prop-outlaws and treaties. ThisEULA grants Younorights touse suchcontent. All rights not expressly granted under this EULA are reserved by DSC and its suppliers.
-
EXPORT RESTRICTIONS – You agree that You will not export or re-export the software PRODUCT to any country, person, or entity subject to Canadian export
restrictions. -
CHOICE OF LAW – This Software License Agreement is governed by the laws of the Province of Ontario, Canada.
-
ARBITRATION – All disputes arising in connection with this Agreement shall be determined by final and binding arbitration in accordance with the Arbitration Act, and the parties agree to be bound by the arbitrator’s decision. The place of arbitration shall be Toronto, Canada and the language of the arbitration shall beEng-lish.
-
LIMITED WARRANTY
- NO WARRANTY – DSC PROVIDES THE SOFTWARE “AS IS” WITHOUT WARRANTY. DSCDOES NOT WARRANT THAT THE SOFTWARE WILL MEET YOUR REQUIREMENTS OR THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE.
- CHANGES IN OPERATING ENVIRONMENT – DSC shall not be responsible for problems caused by changes in operating characteristics of the HARDWARE or for problems in the interaction of theSOFTWARE PRODUCT with non-DSC- SOFTWAREor HARDWARE PRODUCTS.
- LIMITATION OF LIABILITY; WARRANTY REFLECTS ALLOCATION OF RISK – IN ANY EVENT IF ANY STATUTEIMPLIES WARRANTIES OR CONDITIONS NOT STATED IN THIS LICENSE AGREEMENT, DSC’S ENTIRE LIABILITY UNDER ANY PROVISION OF THIS LICENSE AGREEMENT SHALL BE LIMITED TO THE GREATER OF THE AMOUNT ACTUALLY PAID BY YOU TO LICENSE THE SOFTWARE PRODUCT AND FIVE CANADIAN DOLLARS (CAD$5.00). BECAUSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
- DISCLAIMER OF WARRANTIES – THIS WARRANTY CONTAINS THE ENTIRE WARRANTY AND SHALL BE IN LIEU OF ANY AND ALL OTHER WARRANTIES, WHETHER EXPRESSED OR IMPLIED (INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FORA PARTICULAR PURPOSE), AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF DSC. DSC MAKES NO OTHER WARRANTIES. DSC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON PURPORTING TO ACT ON ITS BEHALF TO MODIFY ORTO CHANGE THIS WARRANTY, NORTO ASSUMES FOR ANY OTHER WARRANTY OR LIABILITY CONCERNING THIS SOFTWARE PRODUCT.
- EXCLUSIVE REMEDY AND LIMITATION OF WARRANTY – UNDER NO CIRCUMSTANCES SHALL DSCBE LIABLE FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR INDIRECT DAMAGES BASED UPON BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, STRICT LIABILITY, OR OTHER LEGAL THEORY. SUCH DAMAGES INCLUDE, BUT ARE NOT LIMITED TO, LOSS OF PROFITS, LOSS OF THE SOFTWARE PRODUCT ASSOCIATED EQUIPMENT, COST OF CAPITAL, COST OF SUBSTITUTE ORREPLACEMENT EQUIPMENT, FACILITIES OR SERVICES, DOWNTIME, PURCHASERS’ TIME, THE CLAIMS OF THIRD PARTIES, INCLUDING CUSTOMERS, AND INJURY TO PROPERTY.
WARNING:
DSC recommends that the entire system be completely tested on a regular basis.
However, despite frequent testing, and due to, but not limited to, criminal
tampering or electrical disruption, it is possible for this SOFTWARE PRODUCT
to fail to perform as expected.
FCC COMPLIANCE STATEMENT
CAUTION:
Changes or modifications not expressly approved by Digital Security Controls
could void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception. It has been typing tested and found to comply with the limits for ClassBdevice in accordance with these certifications in Subpart “B” of Part 15 of FCCRules, which are designed to provide reasonable protection against such interference in any residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to television or radio reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Re-orient thereceiving antenna
- Relocate the alarm control with respect to the receiver
- Move the alarm control away from thereceiver
- Connect the alarm control to a different outlet so that the alarm control and receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the
FCCuseful:
“How to Identify and Resolve Radio/Television Interference Problems”. This
booklet is available from the U.S. Government Printing Office, Washington
D.C.20402, Stock# 004-000-00345- 4.
Industry Canada
CAN ICES-3(B)/NMB-3(B)
EN CERTIFICATION
The TheModels HSM2204 and HSM2300 Power supplies have been certified by
Telefication according to EN50131- 1:2006 +A1:2009 andEN50131- 6:2008, for
Grade 2, Class II, TypeA when installed inPC5003C enclosure.