ortofon 2M Moving Magnet Cartridge System

Technical specifications

2M models
2M Verso models
2M Remounted models| ortofon 2M Moving Magnet Cartridge System -
Fig1
---|---
Model| 2M Red| 2M Blue| 2M Bronze| 2M Black| 2M Black LVB 250| 2M 78| 2M Mono
---|---|---|---|---|---|---|---
Output voltage at 1 kHz, 5 cm/sec.|  5.5 mV| 5.5 mV| 5 mV| 5 mV| 5 mV| 4 mV| 4 mV
Tracking ability at 315 Hz| 70 µm| 80 µm| 80 µm| 80 µm| 80 µm| 70 µm| 70 µm
Compliance, dynamic, lateral| 18 µm/mN| 18 µm/mN| 20 µm/mN| 20 µm/mN| 22 µm/mN| 22 µm/mN| 22 µm/mN
Stylus type| Elliptical| Nude Elliptical| Nude Fine Line| Nude Shibata| Nude Shibata| Spherical| Nude Spherical
Tracking force recommended| 1.8 g (18 mN)| 1.8 g (18 mN)| 1.5 g (15 mN)| 1.5 g (15 mN)| 1.6 g (16 mN)| 1.8 g (18 mN)| 1.8 g (18 mN)
Load resistance| 47 kOhm| 47 kohm| 47 kOhm| 47 kohm| 47 kOhm| 47 kOhm| 47 kohm
Load capacitance| 150 – 300 pF| 150 – 300 pF| 150 – 300 pF| 150 – 300 pF| 150 – 300 pF| 150 – 300 pF| 150 – 300 pF
Weight, Cartridge| 7.2 g| 7.2 g| 7.2 g| 7.2 g| 7.2 g| 7.2 g| 7.2 g
Weight, Remounted| 16.7 g| 16.7 g| 16.7 g| 16.7 g| 16.7 g| 16.7 g| 16.7 g

**All specs at recommended tracking force


About the Oroton 2M Series cartridges

Thank you for choosing the Oroton 2M magnetic cartridge system for high performance sound reproduction of your favourite analogue records.
Our company has been working with sound reproduction since 1918. Oroton developed its first phono cartridge in 1948, since then more than 300 different phono cartridges have been developed and manufactured. Reflecting our extensive experience in industrial design and technological know-how we have become the global leader in the manufacture and supply of phono cartridges.
The 2M Series has been engineered in accordance with the highest standards and is congruent with Oroton’s unrelenting commitment to providing the most precise and accurate reproduction possible without coloration.
The 2M Series comprises of three configurations: 2M for top mounting, 2M Verso for bottom mounting, and 2M Remounted for direct mount on s-shaped arms with universal mount. Each configuration consists of 2M 78, Mono, Red, Blue, Bronze, Black and Black LVB 250, which weight and size have been optimized to fit the most common turntables on the market to-day.
As a result of reviewer listening tests we feel confident that you will appreciate and enjoy the unique qualities of these cartridges.

| |
---|---|---
2M
Standard model for top mount heads ells. We have optimized the design  for ease of mounting the cartridge; the weight and
dimensions fit the most common turntables on the market today.| 2M Verso
For bottom mount heads ells. 2M Verso
allows for easy mounting on tonearms which do not allow the screws to pass through the top of the headshield.| 2M Remounted
Designed for direct mount on s-shaped arms with universal mount. 2M Remounted provides correct Baer Wald alignment with the majority of
tonearms with universal mount.

Mounting the 2M cartridge

  1.  Remove stylus unit with stylus guard before working with leads and screws. Handle all parts carefully. (fig. 1-2)ortofon 2M Moving Magnet Cartridge System - Fig5

  2. Note colours and channel indications on rear side of the body for correct connection of the tone arm leads. (fig. 3)ortofon 2M Moving Magnet Cartridge System - Fig6

  3. The Oroton packing contains a pair of screws with a thread length of 5 mm. The screws are to be used with headshield thicknesses of max. 3.5 mm. The 2M threaded
    mounting plate has a thickness of 3 mm.ortofon 2M Moving Magnet Cartridge
System - Fig7To check that you are using the right length of screws – please observe that screws must not touch the body under the mounting plate – look into the small openings on each side of the body. (fig. 4)
    Do not tighten screws completely before the stylus unit has been remounted (fig. 1) – to adjust stylus overhang refer to the record player or tone arm manual and cartridge
    dimensions. (fig. 5)
    Never overtighten screws and never use aluminium screws, as they can get stuck in the threaded holes of the mounting plate.
    Note: If excessively long screws are used and are pressing against the body material, this may influence channel separation and could damage the cartridge body. In case
    of such damage the Oroton warranty will be void.

  4. Adjust tone arm parallel to record surface, adjusting anti-skating and stylus pressure according to cartridge recommended data and record player manual.

Stylus care and maintenance

To obtain optimal sound reproduction, remove dust from stylus regularly by using the enclosed small brush.
If the headshield can be easily removed from the tone arm, we recommend that you turn the diamond upwards and brush gently forward in the direction of the diamond tip along the cantilever.
We do not recommend the use of propyl alcohol (or other cleaning fluids) for cleaning the cartridge, as the diamond cement as well as the suspension system could be
seriously damaged and thereby ruin the cartridge. Fig. 6

Stylus guard

Remove the stylus guard before use by holding at the front and rear of the guard and gently pressing the rear while tilting it downwards. (fig. 7-8)

ortofon 2M Moving Magnet Cartridge System - Fig10

How to replace M2.0 mm screws on 2M Verso

  • Remove the stylus with the stylus protection guard from the cartridge body to avoid any damage to the diamond
  • Using Torx 8 key, unscrew the black screw from the Verso top plate
  • Remove the top plate from the cartridge body by pulling the screws off
  • Remove the two countersunk screws from the top plate
  • Insert the two M2.0 mm screws in the top plate
  • Mount the top plate on the cartridge body. Hold the top plate with screw-threads hanging down and turn the cartridge body 180 degrees. Mount from above
  • Mount the black screw in the top plate and tighten with appropriate force
  • Mount the cartridge on the tonearm using the enclosed tool
  • Mount the stylus with the stylus protection guard on the cartridge body

2M Remounted features

  • Universal mount fitting matching S-shaped tonearms with standard H-4 bayonet mount.
  • Provides correct Baer Wald alignment with the major part of tonearms with universal mount.
  • Gold-plated connectors for optimal audible connection.
  • Distance to connector 52 mm.
  • 2M Remounted cartridge weight: 16.7 g.

ortofon 2M Moving Magnet Cartridge System - Fig11

Warning
This phono cartridge is only for mounting on tonearms and must not be used for other purposes.

Scan and follow the QR code for setup
and support or find more information on
www.ortofon.com/support

accuracy in sound
Oroton A/S
Stavangervej 9
DK-4900 Askov
Tel. +45 54 91 19 15
www.ortofon.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals