BOSSPAC EA000406 DarkRail Communication Gateway Instruction Manual
- June 4, 2024
- BOSSPAC
Table of Contents
BOSSPAC EA000406 DarkRail Communication Gateway Instruction Manual
VISIT OUR WEBSITE FOR MORE INFORMATION. WWW.BOSSPAC.COM
BOSSPAC ENGINEERING TECHNOLOGY, CALGARY HEAD OFFICE
PHONE: 403-216-1226 FAX:
403-216-5557 E-MAIL:
INFO@BOSSPAC.COM
1450 – 28 STREET NE BAY 8, CALGARY, ALBERTA, CANADA T2A 7W6
Introduction
This manual provides basic information on how to commission or join a border router to any device:
- Commission a Border Router onto an existing network
- Joining a Border Router onto a network
Required Tools:
- Computer (Run on Windows)
- DRC Gateway
- 10 to 24V Power Supply
- 915 MHz Antenna
- Ethernet Cable
o Physical connection to Personal Internet router.
1. Installation
The DRC Gateway must be installed by a professional or certified technician
conversant
with the certification requirements of the installation site.
The DRC Gateway requires a voltage between 10 VDC and 24 VDC capable of
supplying up
to 2A. Unless otherwise specified the DRC Gateway ships with a 3 dBi antenna
(EA002058). The DRC Gateway is compatible with the following antennas.
2. Commissioning
2.1 Set-up & Power On
- Connect one end of the Ethernet cable to your ethernet router.
- Connect the other end of the Ethernet cable to the border router (Figure 1)
Figure 1
- Connect the Power Supply corresponding wires to Border Router power port (Figure 2)
Figure 2
- Connect to the 915 MHz Antenna to Border Router (Figure 3)
Figure 3
- Power on/ Plug in the power Supply
2.2 SSH to Border Router
-
On your laptop open Command prompt
-
On command prompt type “ssh pi@###.###.##.##” “#” = Border Router IP address
-
If connecting to the border router for the first time, command prompt will print “Are you
sure you want to continue connecting (yes/no)?” -
Type on command prompt “yes”
-
If the border has a password, command prompt will ask you for a password in which then
you type password and then press enter. -
Command prompt will print “pi@###.###.##.##:~ $”
2.3 Joining, Commissioning and Starting a Network
2.3.1 Joining Ethernet Gateway to an existing network:
- On command prompt type “sudo ot-ctl” then press enter
- Command prompt will print “>”
- On command prompt type “ifconfig up” then press enter
- Command prompt will print “up”
- On command prompt type “joiner start 123456” then press enter’
- Command prompt will print “Done”, and if joining with the device is successful, command prompt will print “joiner successful”
- On command prompt type “thread start” then press enter
- Command prompt will print “Done”
2.3.2 Commission a device to the network
- On command prompt type “sudo ot-ctl” then press enter
- Command prompt will print “>”
- On command prompt type “Commissioner start” then press enter
- Command prompt will print “Done” and “> Commissioner: active”
- On command prompt type “commissioner joiner add * 123456” then press enter
- Command prompt will print “Done”
- To close commissioner type on command prompt “commissioner stop” then press enter
- Command prompt will print “Commissioner: disabled” and “Done”
2.3.3 Start a Network
- On command prompt type “sudo ot-ctl” then press enter
- Command prompt will print “>”
- On command prompt type “dataset init new” then press enter
- Command prompt will print “Done”
- On command prompt type “dataset channel x”; where x represents the desired channel. Valid numbers are between 1 and 10. then press enter
- Command prompt will print “Done”
- Type “dataset commit active”
- Command prompt will print “Done”
- Type “ifconfig up”
- Type “thread start”
FCC & IC Statements
FCC Class B Part 15
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Changes or
modifications not expressly approved by BossPac Engineering Technology Inc.
may void the user’s authority to operate the equipment.
ISED RSP-100 Statement
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
FCC/IC RF Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. The antenna(s) used for this equipment must be
installed to provide a separation distance of at least 8 inches (20cm) from
all persons.
For further Technical Assistance
Email support@bosspac.com
Or call 866-616-1226 or
403-216-1226