PLANET SGS-6310 Series Layer 3 Gigabit/10 Gigabit Stackable Managed Switch Installation Guide

June 9, 2024
PLANET

Layer 3 Gigabit/10 Gigabit Stackable Managed Switch
SGS-6310 Series
Quick Installation Guide

Package Contents

Thank you for purchasing Layer 3 Gigabit/10 Gigabit Stackable Managed Switch, SGS-6310-16S8C4XR/SGS-6310-24T4X/SGS-6310-24P4X
Unless specified, “Managed Switch” mentioned in this Quick Installation Guide refers to the SGS-6310-16S8C4XR/SGS-6310-24T4X/SGS-6310-24P4X.

Model Description
SGS-6310-16S8C4XR Layer 3 16-Port 100/1000X SFP + 8-Port Gigabit TP/SFP +

4-Port 10G SFP+ Stackable Managed Switch
(Dual 100r-,240V AC)
SGS-6310-24T4X| Layer 3 24-Port 10/100/1000T + 4-Port 10G SFP+
Stackable Managed Switch
SGS-6310-24P4X.| Layer 3 24-Port 10/100/1000T 802.3at PoE + 4-Port 10G
SFP+ Stackable Managed Switch

Open the box of the Managed Switch and carefully unpack it. The box should contain the following items:

| SGS-6310-16S8C4XR| SGS-6310-24T4X| SGS-631024P4X
---|---|---|---
Quick Installation Guide| | |
DB9 to RJ45 Interface
RS232 Console Cable| | |
Rack-mount Accessory
Kit| | |
AC Power Cord| 2| 1| 1
SFP Dust Cap| 28| 4| 4

If any item is found missing or damaged, please contact your local reseller for replacement.

Switch Management

To set up the Managed Switch, the user needs to configure the Managed Switch for network management. The Managed Switch provides two management options:
Out-of-Band Management and In-Band Management.

  • Out-of-Band Management
    Out-of-band management is the management through console interface.
    Generally, the user will use out-of-band management for the initial switch configuration, or when in-band management is not available.

  • In-Band Management
    In-band management refers to the management by logging in to the Managed Switch using Telnet or HTTP, or using SNMP management software to configure the Managed Switch. In-band management enables the management of the Managed Switch to attach some devices to the Switch. The following procedures are required to  enable in-band management:
    1. Log on to console
    2. Assign/Configure IP address
    3. Create a remote login account
    4. Enable HTTP or Telnet server on the Managed Switch
    In case in-band management fails due to Managed Switch configuration changes, out-of-band management can be used for configuring and managing the Managed Switch.

The Managed Switch is shipped with VLAN1 interface IP address 192.168.0.254/24 assigned by default. User can assign another IP address to the Managed Switch via the  console interface to be able to remotely access the Managed Switch through Telnet or HTTP.

Requirements

Workstations running Windows XP/2003/Vista/2008/7/8/10, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols.
Workstations are installed with Ethernet NIC (Network Interface Card)
Serial Port Connection (Terminal)

  • The above Workstations come with COM Port (DB9) or USB-to-RS232 converter.
  • The above Workstations have been installed with terminal emulator, such as Tera Term or PuTTY.
  • Serial cable — one end is attached to the RS232 serial port, while the other end to the console port of the Managed Switch.

Management Port Connection

  • Network cables — Use standard network (UTP) cables with RJ45 connectors.
  • The above PC is installed with Web browser

Note
It is recommended to use Internet Explorer 8.0 or above to access the Managed Switch. If the Web interface of the Managed Switch is not accessible, please turn off the anti- virus software or firewall and then try it again.

Terminal Setup

To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to serial (console) port of the Managed Switch. The console port of the  Managed Switch is DCE already, so that you can connect the console port directly through PC without the need of Null Modem.PLANET
SGS-6310 Series Layer 3 Gigabit 10 Gigabit Stackable Managed Switch -
setup

A terminal program is required to make the software connection to the Managed Switch. Tera Term program may be a good choice. The Tera Term can be accessed from the Start menu.

  1. Click START menu, then Programs, and then Tera Term.
  2. When the following screen appears, make sure that the COM port should be configured as:
    • Baud: 9600
    • Parity: None
    • Data bits: 8
    • Stop bits: 1
    • Flow control: None

4.1 Logging on to the Console
Once the terminal is connected to the device, power on the Managed Switch, and the terminal will display “running testing procedures”.
Then, the following message asks for the login user name and password. The factory default user name and password are as follows as the login screen in Figure 4-3 appears.

Username: admin
Password: adminPLANET SGS-6310 Series Layer 3 Gigabit 10 Gigabit
Stackable Managed Switch - code 1

The user can now enter commands to manage the Switch. For a detailed description of the commands, please refer to the following chapters.

Note

  1. For security reason, please change and memorize the new password after this first setup.
  2. Accept command in lowercase or uppercase letter under console interface.

4.2 Configuring IP Address
The IP address configuration commands for VLAN1 interface are listed below.
Before using in-band management, the Managed Switch must be configured with an IP address by out-of-band management (i.e. console mode). The configuration commands are as follows:

Switch#config
Switch_config#interface vlan 1
Switch_config_v1)#ip address 192.168.1.254 255.255.255.0

The previous command would apply the following settings for the Managed Switch.
IPv4 Address: 192.168.1.254
Subnet Mask: 255.255.255.0

To check the current IP address or modify a new IP address for the Managed Switch, please use the procedures as follows:
Show the current IP address

  1. On “Switch#” prompt, enter “show ip interface brief”.
  2. The screen displays the current IP address, subnet mask and gateway as shown in Figure 4-5.
    PLANET SGS-6310 Series Layer 3 Gigabit 10 Gigabit Stackable Managed Switch -
code 2

If the IP is successfully configured, the Managed Switch will apply the new IP address setting immediately. You can access the Web interface of Managed Switch through the  new IP address.

Note
If you are not familiar with console command or the related param- eter, enter “help” anytime in console to get the help description.

4.3 Setting 1000BASE-X for 10G SFP+ Port
The Managed Switch supports both 1000BASE-X and 10GBASE-X SFP transceivers by manual setting and the default SFP+ port speed is set in the fiber auto mode, so the  end-user can plug the transceiver directly.
In another example, the end-user has to force the fiber connection with 1000BASE-X SFP transceiver in the togetherness 0/1. The following command configuration is required:PLANET SGS-6310 Series Layer 3 Gigabit 10 Gigabit
Stackable Managed Switch - code 3

4.4 Changing Password
The default password of the switch is “admin”. For security reason, it is recommended to change password and the following command configuration is required:PLANET SGS-6310 Series Layer 3 Gigabit 10 Gigabit Stackable Managed
Switch - code 4

4.5 Saving the Configuration
In Managed Switch, the running configuration file stores in the RAM. In the current version, the running configuration sequence running-config can be saved from the RAM to FLASH by write command, so that the running configuration sequence becomes the start-up configuration file, which is called configuration save.

Switch#write
Switch#write
Saving current configuration.
OK!
Switch#Jan 2 00:56:04 /startup-config is wrote, TID:85bd29c0
Figure 4-8 Write Screen

Starting Web Management

The Managed Switch provides a built-in browser interface. You can manage it remotely by having a remote host with Web browser, such as Microsoft Internet Explorer,  Mozilla Firefox, Google Chrome or Apple Safari. PLANET SGS-6310
Series Layer 3 Gigabit 10 Gigabit Stackable Managed Switch -
diagram

The following shows how to start up the Web Management of the Managed Switch. Please note the Managed Switch is configured through an Ethernet connection. Please  make sure the manager PC must be set to the same IP subnet address.
For example, the IP address of the Managed Switch is configured with 192.168.0.254 on Interface VLAN 1, then the manager PC should be set to 192.168.0.x (where x is a  number between 2 and 253, except 1 or 254), and the default subnet mask is 255.255.255.0.
The factory default user name and password are as follows:

Default IP of Interface VLAN 1: 192.168.0.254
Username: admin
Password: admin

5.1 Logging in to the Managed Switch from copper ports

  1. Use Internet Explorer 8.0 or above Web browser and enter IP address http://192.168.0.254 (that you have just set in console) to access the Web interface.

  2. When the following dialog box appears, please enter the configured username “admin” and password “admin” (or the username/password you have changed via  console). The login screen in Figure 5-2 appears.

  3. After entering the password, the main screen appears as shown in Figure 5-3.
    PLANET SGS-6310 Series Layer 3 Gigabit 10 Gigabit Stackable Managed Switch -
swtich

  4. The Switch Menu on the left of the Web page lets you access all the commands and statistics the Switch provides.
    Now, you can use the Web management interface to continue the Switch management or manage the Managed Switch by console interface. Please refer to the user  manual for more.

5.2 Saving Configuration via the Web
The configuration area is to show the content that is selected in the navigation area. The configuration area always contains one or more buttons, such as “Refresh”, “Apply” and “Reset”.
The “Apply” button indicates applying the modified configuration to the device. The application of the configuration does not mean that the configuration is saved in the  configuration file.
To save the configuration, you have to click “Save All” on the top control bar.
“Save All” function is equivalent to the execution of the write command.PLANET SGS-6310 Series Layer 3 Gigabit 10 Gigabit Stackable Managed
Switch - configuration

LED Indicators

6.1 SGS-6310-24T4X
System

LED Color Function
PWR Green Lights to indicate that the Switch has power.
Off Power is off.
SYS Green Slow blinks to indicate the system is normally starting up.

Interfaces

LED Color Function
LNK/ACT Green Lights

successfully established.
Blinks| Indicating that the switch is actively sending or
receiving data over that port.

10G Status LED

LED Color Function

LNK/ACT
(Ports 25-28)| Green| Lights| Indicating the port is running and the connection is
successfully established.
Blinks| Indicating that the switch is actively sending or
receiving data over that port.

System

LED Color Function
PWR Green Lights to indicate that the Switch has power.
Off Power is off.
SYS Green Slow blinks to indicate the system is normally starting up.

Interfaces

LED Color Function

1000 LNK/
ACT| Green| Lights| Indicating the port is running at 1000Mbps speed
and successfully established.
Blinks| Indicating that the switch is actively sending or
receiving data over that port.
10/100 LNK/
ACT| Amber| Lights| Indicating the port is running at 10/100Mbps
speed and successfully established.
Blinks| Indicating that the switch is actively sending or
receiving data over that port.
LED| Color| Function
---|---|---
10G LNK/
ACT| Amber| Lights| Indicating the port is running at 10Gbps speed
and successfully established.
Blinks| Indicating that the switch is actively sending or
receiving data over that port.
1000 LNK/
ACT| Green| Lights| Indicating the port is running at 1000Mbps speed
and successfully established.
Blinks| Indicating that the switch is actively sending or
receiving data over that port.

System

LED Color Function
PWR Green Lights to indicate that the Switch has power.
Off Power is off.
SYS Green Slow blinks to indicate the system is normally starting up.

Interfaces

LED Color Function
LNK/ACT Green Lights

successfully established.
Blinks| Indicating that the switch is actively sending or
receiving data over that port.

10G Status LED

LED Color Function

LNK/ACT
(Ports 25-28)| Green| Lights| Indicating the port is running and the connection is
successfully established.
Blinks| Indicating that the switch is actively sending or
receiving data over that port.

Customer Support

Thank you for purchasing PLANET products. You can browse our online FAQ resource at the PLANET Web site first to check if it could solve your issue. If you need more  support information, please contact PLANET support team.
PLANET online FAQs: http://www.planet.com.tw/en/support/faq.php?type=1
Support team mail address: [email protected]
SGS-6310-Series User’s Manual
https://www.planet.com.tw/en/support/downloads?&method=keyword&keyword=SGS-6310&view=3#list

https://www.planet.com.tw/en/support/downloads?&method=keyword&keyword=SGS-6310&view=3#list

Copyright © PLANET Technology Corp. 2022.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PLANET User Manuals

Related Manuals