Product Information

The Magnetic Mounting Optional accessory MM-HDPQ (118329-G1) is designed to allow the Dranetz HDPQ Xplorer, Xplorer 400, Guide, or Visa to be attached to ferromagnetic metallic surfaces. The accessory uses neodymium magnets, so individuals with pacemakers or internal medical devices should not handle strong rare-earth magnets as magnetic fields can affect the operation of these devices. The magnetic mount is only for use with the equipment described in the instructions and can only support this equipment in a safe manner.

INTRODUCTION

The Magnetic Mounting Optional accessory MM-HDPQ allows the Dranetz HDPQ Xplorer, Xplorer 400, Guide, or Visa to be attached to ferromagnetic metallic surfaces.
This instruction guide contains procedures on how to mount the MM-HDPQ accessory to the instrument and its use.
Read all Warning and Safety Precautions before attempting to connect and operate the instrument.

Product Usage Instructions

  1. Read all warning and safety precautions before attempting to connect and operate the instrument.
  2. Remove the hanger bracket from the instrument by removing two #6-32 x 5/16 long Phillip screws and two flat washers from the hanger bracket. Store the screws with the hanger bracket if used in the future.
  3. Replace the hanger bracket with shoulder plate (P/N 118312-G1) that is a standard HDPQ accessory and is part of the Keyhole Mounting Kit. The screws supplied with the Keyhole Mounting Kit are not used when installing the Magnet Housing, set them aside and store them if used in the future.
  4. Secure the Magnet Housing Assembly (P/N 118329-G1) to the unit using the two A Phillip screws (P/N 902248-LF, #6-32, 7/8 in.) that are attached to the magnet housing.
  5. Follow all Warning and Safety Precautions before attempting to connect and operate the Xplorer, Xplore 400, Guide, or Visa. Refer to the User’s Guide for circuit connection and operation instructions.

When removing the instrument with the attached magnetic mount from a metal surface, lift up from the bottom of the instrument and pull toward you to avoid any scratches to the surface. Keep all magnets away from any type of magnetic storage media as magnetic fields may cause damage to magnetic storage media.

The information in the manual has been reviewed and is believed to be entirely reliable, however, no responsibility is assumed for any inaccuracies. All material is for informational purposes only and is subject to change without prior notice. By accepting and using this manual, you agree that the information contained herein will be used solely for the purpose of operating equipment of Dranetz.

CAUTION STATEMENTS

  • Neodymium magnets are used in this mounting option. Individuals with pacemakers or internal medical devices should not handle strong rare-earth magnets. Studies have shown that magnetic fields can affect the operation of these devices. These magnets should be kept at a safe distance from individuals with these devices.

  • This magnetic mount is for use with the equipment described in these instructions only and can only support this equipment in a safe manner.
    DO NOT use this option to support any additional equipment.

  • When removing the instrument with the attached magnetic mount from a metal surface lift up from the bottom of the instrument and pull toward you to avoid any scratches to the surface.

  • Magnetic fields may cause damage to magnetic storage media. Keep all magnets away from any type of magnetic storage media.

INSTRUCTIONS

  1. Remove the hanger bracket from the instrument by removing two #6-32 x 5/16” long Phillip screws and two flat washers from the hanger bracket.
    Note: The screws used with the hanger bracket are not used with the magnetic mount, so please store them with the hanger bracket if used in the future.

  2. Replace the hanger bracket with shoulder plate (P/N 118312-G1) that is a standard HDPQ accessory and is part of the Keyhole Mounting Kit. The screws supplied with the Keyhole Mounting Kit are not used when installing the Magnet Housing, set them aside and store them if used in the future.DRANETZ-118313-G1-Keyhole-Mounting-Kit-1

  3. Secure the Magnet Housing Assembly (P/N 118329-G1) to the unit using the two “A” Phillip screws (P/N 902248-LF, #6-32, 7/8 in.) that are attached to the magnet housing.DRANETZ-118313-G1-Keyhole-Mounting-Kit-2DRANETZ-118313-G1-Keyhole-Mounting-Kit-3

  4. Follow all Warning and Safety Precautions before attempting to connect and operate the Xplorer, Xplore 400, Guide, or Visa. Refer to the User’s Guide for circuit connection and operation instructions.

Statement of Warranty

All Dranetz manufactured portable instruments and accessories are warranted to the original purchaser against defective material and workmanship for a period of three years from the date of invoice. User replaceable instrument batteries are warranted for a period of one year from the date of invoice. Certain Dranetz branded accessories, such as current transformers and other accessories not manufactured by Dranetz, are warranted to the original purchaser against defective material and workmanship for a period of one year from the date of invoice. Warranties for products and accessories sold by, but not branded as Dranetz, are covered by their respective manufacturer’s warranties and are not warranted by Dranetz. Dranetz will repair or replace, at its option, all defective equipment that is returned, freight prepaid, during the warranty period. There will be no charge for repair, provided there is no evidence that the equipment has been mishandled or abused. This warranty shall not apply to any defects resulting from improper or inadequate maintenance, buyer-supplied hardware/software interfacing, unauthorized modification or misuse of the equipment, operation outside of environmental specifications, or improper site preparation or maintenance.

Statement of reliability
The information in this manual has been reviewed and is believed to be entirely reliable, however, no responsibility is assumed for any inaccuracies. All material is for informational purposes only and is subject to change without prior notice.

Notice regarding proprietary rights
This publication contains information proprietary to Dranetz. By accepting and using this manual, you agree that the information contained herein will be used solely for the purpose of operating equipment of Dranetz.

This publication is protected under the Copyright laws of the United States, Title 17 et seq. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form, by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior written consent of Dranetz.
Copyright © 2016 Dranetz
All Rights Reserved. Printed in the United States of America.

Trademarks
Dranetz HDPQ® is a registered trademark of Dranetz.

Test Equipment Depot – 800.517.8431 – 5 Commonwealth Ave, Woburn, MA 01801 TestEquipmentDepot.com

5 Commonwealth Ave
Woburn, MA 01801
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmenDepot.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals