KENT Prime Star-B RO Water Purifiers Instruction Manual

June 9, 2024
Kent

KENT Prime Star-B RO Water Purifiers

Product Information: Overhead Water Tank Purifier

The Overhead Water Tank Purifier is a device designed to purify water from an overhead tank. It has three outlets – Tank Water, Pure Water, and Rejected Water. The rejected water can berecirculated to the overhead tank, reducing water wastage. It is recommended to avoid exposure to direct sunlight and installation in damp areas. The maximum distance between the water source and the purifier should not be more than 3 meters. To ensure optimum performance, genuine KENT spares should be used.

Product Usage Instructions

  1. Installation Procedure: Follow the below steps Lfor installation:
  2. Refer to the wall hanging diagram for installation.
  3. Install the purifier according to figures 1-4.
  4. Connect the water source to the purifier inlet.
  5. Connect the purifier outlet to the overhead tank.
  6. Water Temperature: Make sure that the temperature of the water entering the purifier is within 10 C – 40 C.
  7. Pipe Installation: Avoid sharp bends in the pipe. Do not bend or block the reject water pipe.
  8. Power Supply: In case of not using the purifier for more than two days, kindly switch off the power supply and drain the storage tank.
  9. Cleaning: To keep the storage tank clean, it should be drained once every 15 days.
  10. Service: Do not try to service the purifier on your own. Instead, call a service technician for help.

Dear Customer,
At the outset, allow us to thank you for your truest in KENT water purifiers We take pride in our reputation for product quality and industry proven
performance. We are certain that your decision to own a KENT Prime Star-B Mineral RO™M Water Purifier will go a long way towards keeping you and your family in good health. We are confident that you will be satisfied with its performance and that it will serve your need for safer and cleaner drinking water without any compromise. This guide will help you in getting the best out of your water purifier. Please go through this booklet to familiarize yourself with its operation and maintenance. You can look forward to years of trouble free service. To ensure that the warranty of your water purifier is effective, it is important that you fill up the enclosed warranty card and mail us the installation report within 15 days of purchase. In case you need any further information, contact your nearest KENT dealer or branch.
Best Wishes,
KENT RO SYSTEMSLTD.

KENT TECHNOLOGY – A Breakthrough in Water Purification*

Presenting the KENT Prime Star-B Mineral ROT Water Purifier. It uses futuristic and state-of-the-art technology to provide purer and healthier drinking water.
At the heart of the KENT Prime Star-B Mineral RO™M Water Purifier is a Reverse Osmosis membrane having capillaries as small as 0.0001 microns, which reduce dissolved impurities (salts and heavy metals) and convert hard water to sweet and pure drinking water. With a patented mineral retention system, the KENT Prime Star-B Mineral ROT Water Purifier allows the user to control the Total Dissolved Solids (TDS) level in the purified water.
KENT is pleased to introduce Zero Water Wastage Technology™ that recirculates rejected water to overhead tank with its own pump to make it Zero Water Wastage RO. This unique technology helps you make water 100% pure, without wasting any water while retaining essential minerals.

Salient Features of KENT Prime Star-B Mineral RO™M Water Purifier

  • Water purifier with UV Disinfection in tank to purity and long life keep purified water pure
  • Zero Water Wastage**
  • RO membrane fused inside membrane housing to prevent tampering
  • Purification by RO+UV+UF+TDS Control+UV in Tank makes water
  • Vertically mounted SMPS for protection from water
  • Real time monitoring and display of purity on a digital screen.
  • Use of push-fit fittings for leakage and a digital screen maintenance free performance
  • Suitable for purification of brackish, tap water & municipal corporation water supply
  • An aesthetically appealing design
  • ABS construction for corrosion free use
  • Wall mounted design, best suited for Indian homes and offices
  • Inbuilt Auto-flushing system
  • 9 L storage tank with water level indicator
  • Fully automatic operation, with auto-on and auto-off function
  • High purification capacity of 20 L/hr.
  • Computer controlled operation for enhanced

Items in the Box

  1. KENT Prime Star-B Mineral RO Water Purifier :1 N
  2. 3-Way Connector :1 N
  3. S.S. Ball Valve :1 N
  4. Food Grade Pipe 0.635 cm (White) : 20 Meters
  5. Food Grade Pipe 0.635 cm (White) : 2.5 Meters
  6. Bulk Head Union : 1 N
  7. Fixing Clips : 25N
  8. Tie Wire 4 inch : 4N
  9. Union Connector  : 1N
  10. Warranty card    :  1N
  11. Screws & Plastic Inserts : 2N
  12. Sticker Center Drill  :   1N

Important Instructions

  • Avoid exposure to direct sunlight and installation in damp areas.

KENT Prime Star-B RO Water Purifiers 05

  • Avoid sharp bends in the pipe. Do not bend or block the reject water pipe.

KENT Prime Star-B RO Water Purifiers 08

  • In case of not using the purifier for more than two days, kindly switch off the power supply and drain the storage tank.

KENT Prime Star-B RO Water Purifiers 09

  • Use genuine KENT spares for optimum performance.

KENT Prime Star-B RO Water Purifiers 10

KENT Prime Star-B RO Water Purifiers 11

KENT Prime Star-B RO Water Purifiers 12

  • To keep the storage tank clean, it should be drained once every 15 days.

  • Do not try to service the purifier on your own. Instead,  call a service technician for help.

Reverse Osmosis Process

The Reverse Osmosis process, also known as hyper filtration, is the finest filtration process known till date. The process ensures the reduction of particles as small as ions from a solution. Reverse Osmosis uses a semi- permeable membrane to reduce salts from potable/ brackish water. In Reverse Osmosis, water pressure  applied to the concentrated side forces the process of osmosis into reverse. Under enough pressure, treated water is “squeezed” through the membrane from the concentrated side to the diluted side. Salts dissolved in  water as charged ions are repelled by the RO membrane The rejected impurities on the concentrated side of the membrane are washed away in a stream of waste water, and thus do not get accumulated as in a traditional filter.

UV Process

The UV light has shorter wavelength (higher energy) than the visible light. It is called ultra-violet because it is just beyond the violet light in the light spectrum. Technically, the ultra-violet light is defined to be any wavelength of light, which is shorter than 400 nanometer.
UV rays, which penetrate into the micro-organisms, are absorbed by the DNA of the pathogen in the water. The DNA is altered in such a way that the pathogen cannot reproduce. Thus, they are essentially killed and cannot cause infection. This process of DNA modification is called inactivation.

KENT Prime Star-B RO Water Purifiers 16

Note: The purified water stored in the tank is disinfected using UV LED, which automatically switches on for 30 minutes in a two hour cycle.

Auto-flushing System

The purpose of the Auto-flushing system is to help prevent scaling or fouling of the RO membrane by providing a rapid rinse which washes away impurities from the membrane’s  surface and keeps the membrane clean. It offers following benefits:

  • Lowers rejected water out flow
  • Improves “TDS” rejectionrate i.e increases the RO membrane’s efficiency
  • Extends life of RO membrane

Water Flow Diagram

Electrical Circuit Diagram

KENT Prime Star-B RO Water Purifiers 18

KENT Prime Star-B Operations

Screen Explained

  1. RO Flow Indicator
  2. Filter Life Indicator
  3. Power On/Off
  4. ROPumpOn
  5. TankFull
  6. Auto Flushing On
  7. Mineral Content in Purified Water
  8. Warning Signs

Normal Running Conditions
Under normal running conditions and without any fault,  the users would be greeted with a screen as shown in the figure, with Power, Tank Full, Filter Life and Water Quality Indicator On Since the tank is full, the RO flow rate would not be displayed

Emptying of Tank
When water is drawn from the tank, thus emptying it, the water tank sign would turn Off,and instead RO Flow, Purification and Mineral Quality would turn 0 Depending upon the mineral contents in the water, the indicator would display Low, Good or High

Mineral Content – Low
If the TDS level in the purified water is less than the permissible range, the indicator would be in Yellow zonei.e Low
The warning sign would be displayed as shown in the figure

Mineral Content – Good
If the TDS level in the purified water is within the permissible range, the indicator would be in Green zonei.eGood

Mineral Content – High
If the TDS level in the purified water is more thE permissible range, the indicator would be in Red zonE  i.eHigh The warning sign would be displayed as shown in thE  figure

What to do if Mineral Content is Low or High?
Call Customer Care or Login to App
*Mineral Content is displayed based on TDS levels in the purified water

In case of No Water Input, the warning would be displayed, as shown in the figure
The water purifier would automatically shut off and will  remain off till regular water supply is not restored

KENT Prime Star-B RO Water Purifiers 25

Auto-flushing
Auto Flush sign as shown in the figure indicates that RO Membrane is getting flushed automatically Once Auto-flushing is complete, the light would turn Off

UV Lamp Failure/LED Failure
If UV Lamp fails, machine will display a blinking  warning signal of UV failure and an alarm with a single beep. will be audible The purifier would stop
purifying water till the UV lamp is replaced If UV LED fails, machine will display a blinking  warning signal of UV failure and an alarm with two beeps will be audible If the interface shows a UV failure message, switch  off the purifier and call a service technician for help

Filter Replacement
On exhaustion of filter life, ‘Replacement Filter message’ will be displayed on screen with a continuous buzzer and the purifier will stop purifying water till filters are not replaced. If the interface shows ‘Replace Filter Message’, switch off the purifier and call a service technician for help.

Low RO flow warning sign indicates reduced capacit~ of RO Membrane
– A LOW RO FLOW –
Although the water purifier will continue working till the membrane failure happens, it is recommended to call the KENT Customer Care and ask for Membrane Replacement

KENT Prime Star-B RO Water Purifiers 29

Computer Controlled Operation

To ensure delivery of purer and healthier water, a micro-processor is installed in the purifier that performs the
following functions:-

  • UV Stabilization Delay: To ensure that the UV lamp is pre-heated and is working at its optimum level before i1 starts disinfecting water, the controller provides a two second delay to the UV lamp when the purifier is switched on. During this period, only the UV lamp is switched on and other electrical devices of the purifier are switched off.

  • Purification Delay: To ensure that the idle water lying in the internal pipes and in the UV chamber is disinfected before being passed into the storage tank, the system provides a 5 second delay when the purifier is switched on
    During this time, the UV lamp kills all micro-organisms that may be in the water inside the UV chamber. After this delay, all other electrical devices such as the booster pump and solenoid valve are switched on to start normal purification process.

  • Alarm: To ensure delivery of purer water, KENT Prime Star-B Mineral RO™ in-built micro controller controls and senses various vital components and displays their status on the digital interface.

Automatic Operation

  • The purifier automatically shuts off when the storage tank is full
  • The purifier does not start if the inlet water supply pressure falls below 0.3 kg/cm’
  • The purifier automatically restarts when the water level drops below the maximum
  • The purifier does not allow any water rejection in absence of electricity /when tank is full

Installation Instructions

The KENT Prime Star-B Mineral RO™ Water Purifier is a product of advanced technology, which ensures safe and clean drinking water. The purifier is easy and convenient to install.

Recommended Site Preparations:

  • Single Phase 100-250 V AC, 50-60 Hz. connection not more than 3m away from the point of installation of the purifier
  • Raw water supply with ½ inch nipple not more than 3m away
  • Space as per the dimensions of the purifier
  • Wall/plane surface for mounting two screws and holding the machine
  • The system and installation mustcomplywith state and local laws & regulations

Specific Instructions:

  • KENT Prime Star-B Mineral RO™ Water Purifier is a wall mountable purifier. Make sure that it is only mounted on a wall.Avoid installation on wooden and metallic stands
  • For optimum performance and minimum inlet pressure required, ensure that the raw water supply tank is at least 10 ft.above the purifier

Installation Procedure:

Wall Hanging Diagram

KENT Prime Star-B RO Water Purifiers 30

  1. Paste the central drill sticker on a wall at 3.6 Feet to 4.0 Feet from the ground as per your convenience.
  2. Ensure that the sticker is pasted straight on the wall, then drill holes as per the space provided on the sticker
  3. Now, insert the puff up with the help of a hammer
  4. Screw in two 10X50 self-taping screws, 5.4 inches (138 mm) apart horizontally
  5. Carefully hang the purifier on the wall with the help of wall-mounting slot holes provided on the back side of the purifier

Note:

  1. If the wall is not straight or the screws are not properly drilled in an even position, it will damage your purifier

  2. Keep the device away from heat or direct sunlight

  3. First fix the SS ball valve (marked no. 4) to the 1/4 inch port of the 3-way connecter (marked no. 2) shown in figure 2.

  4. Connect the 3-way connector to the raw water supply (marked as no. 1) as shown in the figure 3. The 3-wayconnector is fitted in line with the rawwatersupply.
    KENT Prime Star-B RO Water Purifiers 33

  5. The other end of the 3-way connector can be connected to a tap (marked no.3) as shown in figure 4 or can be plugged off if not required.

Step-3

  1. Now connect one end of the white pipe to the SS ball valve and the other end to the upper push-fit elbow fitting to the left hand side of the purifier labelled WATER IN,asshown in figure 1.

  2. Similarly, connect one end of the white pipe to the lower elbow fitting connector in the tank labelled REJECT WATER and leave the other end in the overhead tank, as shown in fig 2.

Step-4
Before connecting the power supply, it is important that you perform the following functions:

  1. Open the SS ball valve (handle parallel to the ball valve) to start the flow of water into the purifier.as shown in the figure.
  2. Waitfor2-3 minutes to ensure that the filters are soaked in water.

Step-5

  1. Connect the power supply.
  2. Installation is complete.

TDS Adjustment*

The uniqueTDS Control System enables customers to retain the contents of natural minerals (TDS) in purified water, as per their requirement.

  • Turning the screw of the valve anti-clockwise results in increased mineral content
  • Turning the screw of the valve clockwise results in decreased mineral content

We recommend keeping the TDS at lowest but not below 50mg/l.

Starting Up the Purifier

  • Switch on the power supply
  • Wait till the storage tank completely fills up**
  • Switch off the power supply
  • Drain the storage tank by opening the drain plug present at the bottom of the storage tank, so as to remove any dust particles present in the pipes and storage tank
  • Close the drain plug and switch on the power supply
  • The purifier is ready to use

Maintenance

To ensure that the purifier operates at its optimum level, routine maintenance must be performed. The frequency of the maintenance will greatly depend upon the raw water quality and consumption of treated water.

  • The storage tank must be drained once in 2 weeks.

  • To do so, switch off the power supply, open the drain plug at the bottom of the tank and allow the water to drain.Then, screw back the plug and switch on the power supply

  • Replace the sediment, activated carbon and post carbon filter when the filter change alarm is audible, or after every 12 months. It is recommended to change the FRTwhen the filters are replaced

  • Replace the RO membrane once every year

  • Replace the UV Lamp once in a year

  • If you are not going to use the purifier for a long time (in case you are on a holiday, tour or out of home), make sure that you disconnect the power supply, turn off the raw water supply and drain the storage tank

  • Tested & certified by TUV-SUD South Asia (P) Ltd.
    ** Tested or certified flushing time – 24hrs.

The Reverse Osmosis system contains a replaceable treatment component critical for the effective reduction of total dissolved solids and that product water shall be tested periodically to verify that the system is performing properly.
Replacement of spare parts are as under:-

  • 20010 SP In line Sediment Filter 8″
  • 20529 SP RO Membrane
  • 20009 SP In line Carbon Filter 8″
  • 20015 SP Post Carbon Filter (Blue)
  • 20003 SP Hollow Fibre Membrane
  • 20020 SP FRT 450

Note: Filters and membrane are consumables. Their replacement time is dependent on the quality of raw water and water consumption. They are not covered under the warranty. However, if a filter chokes within six  months and a membrane within a year, it will be cleaned/repaired/replaced free of cost. Changing the filters and system inspection is available on call. The treatment capacity of the RO membrane will reduce with time  due to clogging of pores of membranes.
“This Reverse Osmosis system contains a replaceable component critical to the efficiency of the system. Replacement of the reverse osmosis component should be with one of identical specifications as defined by the manufacturer, to ensure the same efficiency and contaminant reduction performance.”

Important Safety Instructions

  • If the supply cord is damaged, it must be replaced by the original part in order to avoid hazard
  • Children should be supervised to ensure that they do not play with the appliance
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety

Warning

  • Do not operate the UV-C emitter when it is removed from the appliance enclosure
  • Read the maintenance instructions before opening the appliance
  • The appliance must be disconnected from the supply before replacing the UV-C emitter

Technical Specifications

KENT-Prime-Star-B-RO-Water -Purifiers-39

KENT-Prime-Star-B-RO-Water -Purifiers-40

  • Treatment capacity tested for tap water having TDS level of 750ppm at room temperature.

Testing Information
The System has been tested according to IS 10500:2012 (Standards for drinking water as per Bureau of Indian Standards) for reduction of the hazardous substances.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals