VISTA 1051KM Architectural Series Linear LED Floodlight Instruction Manual

June 10, 2024
VISTA

VISTA 1051KM Architectural Series Linear LED Floodlight

VISTA-1051KM-Architectural-Series-Linear-LED-Floodlight-PRODUCT-
IMG

Product Information

The 1051KM / 1052KM / 1054KM Architectural Series is a luminaire designed for outdoor installation. The product comes with a knuckle stem that can be attached to a junction box for mounting. The luminaire is designed to be used with wet location-rated J-Box and is supplied with conduit supply conductors (by others) to connect with the luminaire conductors. The package includes a fixture body, knuckle stem, knuckle aiming screw, knuckle set screw, knuckle flange, junction box lid screws (4), and junction box.

Product Usage Instructions

  1. Ensure that the electrical supply is off at the circuit breaker before starting luminaire installation or servicing the luminaire.
  2. Thread the stainless steel (SS) knuckle stem into the junction box lid and tighten it fully.
  3. Loosen the knuckle aiming screw and rotate the knuckle stem to align with the SS knuckle stem.
  4. Route the luminaire supply conductors into the wet location rated J-Box (by others) and attach conduit supply conductors (by others) to the luminaire conductors observing polarity, the line to black, neutral to white, and ground to green. Connect the supply/luminaire conductors using approved wiring methods.
  5. Secure the junction box lid onto the junction box using the junction box lid screws and tighten them.
  6. Position the knuckle to stem over the SS knuckle stem and lock it in place with the knuckle set screw(s).
  7. Adjust the aim of the fixture and firmly re-tighten the knuckle aiming screw(s).
  8. Supply power to the luminaire and check for proper operation.

INSTALLATION INSTRUCTIONS

IMPORTANT NOTE

  • Luminaire must be installed and grounded in accordance with the National Electrical Code (NEC) and local codes.
  • Luminaire is UL listed for above-grade installation only.
  • Always use UL-recognized wire connectors for connections.

MAINTENANCE: To assure proper operation and efficiency, the lens must be kept clean and free of dirt, dust, leaves, trash, and mineral deposits from water. A regularly scheduled maintenance program is recommended.
SAFETY WARNING: Luminaire can become hot. Take care when locating luminaires.
NOTE: Save these instructions for future reference.

LUMINAIRE MOUNTING (KNUCKLE) TO JUNCTION BOX(ES)

  1. Make sure the electrical supply is off at the circuit breaker before starting luminaire installation or servicing the luminaire.
  2. Thread SS Knuckle Stem into Junction Box Lid. Tighten fully.
  3. Loosen the Knuckle Aiming Screw, and rotate the Knuckle Stem to align with SS Knuckle Stem.
  4. Route luminaire supply conductors into wet location rated J-Box (by others). Attach conduit supply conductors (by others) to the luminaire conductors observing polarity, the line to black, neutral to white, and ground to green. Connect the supply/luminaire conductors using approved wiring methods.
  5. Secure the Junction Box Lid onto the Junction Box using the Junction Box Lid Screws. Tighten.
  6. Position the Knuckle Stem over the SS Knuckle Stem. Lock in place with Knuckle Set Screw(s).
  7. Adjust the aim of the fixture and firmly re-tighten the Knuckle Aiming Screw(s).
  8. Supply power to the luminaire and check for proper operation.

VISTA-1051KM-Architectural-Series-Linear-LED-Floodlight-
FIG-1

Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture shown without further notification.

1625 Surveyor Avenue • Simi Valley, CA 93063 • 805-527-0987 • (800) 766-VISTA (8478) • FAX: (888) 670-VISTA (8478) • email@vistapro.comwww.vistapro.com