Altronix VR6 Voltage Regulator Installation Guide
- June 4, 2024
- Altronix
Table of Contents
Altronix VR6 Voltage Regulator
Overview
Altronix VR6 voltage regulator is designed to convert a 24VDC input into a regulated 5VDC or 12VDC output. For use with Maximal, eFlow, ULX, and Trove series of power supplies.
Specifications
Agency Listings:
- UL 294 6th Edition: Access Control System Units.*
- ULC-S319: Electronic Access Control Systems.**
Power Input / Output:
- Input: 24VDC @ 1.75A – Output: 5VDC @ 6A.
- Input: 24VDC @ 3.5A – Output: 12VDC @ 6A.
Output:
- 5VDC or 12VDC regulated output.
- Output rating 6A max. non-power-limited.
- Surge suppression.
LED Indicators:
- Input and output LEDs.
Electrical:
- Operating temperature: 0º C to 49º C ambient.
- Humidity: 20 to 85%, non-condensing.
Mechanical:
- Product weight (approx.): 0.4 lb. (0.18 kg).
- Shipping weight (approx.): 0.5 lb. (0.23 kg).
UL 294 Levels: Attack: I, Endurance: IV, Line security: I, Stand-by power: I. **ULC-S319: Class 1.
Installation Instructions
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, with Canadian Electrical Code CSA C22.1, and with all local codes and authorities having jurisdiction. The product is intended for indoor use only and should be installed by qualified personnel.
-
Mount VR6 in the desired location/enclosure.
Note: If VR6 needs to be elevated above the mounting surface, use included spacers (regular for VR6 only, male/female for mounting with PDS8/PDS8CB). Make sure to use a metal spacer under the mounting hole with a star pattern (Fig. 2b, pg. 3). -
Connect the 24VDC power source to the terminals marked [+ IN –] (Fig. 1 pg. 2).
-
Select output voltage 5VDC or 12VDC using a switch [S1].
-
Connect the power distribution module to the terminals marked [+ OUT –] (Fig. 1 pg. 2).
Connecting PDS8/PDS8CB Board to VR6
Refer to PDS8/PDS8CB Installation Guide Rev. 070116
-
Mount VR6 in the desired location/enclosure.
-
Plug in the male 8-pin connector to the female 8-pin receptacle on the VR6 board (Fig. 2a, pg. 3).
-
Fasten spacers (Fig. 2, pg. 3). Use metal spacers over the mounting hole with star pattern (Fig. 2b, pg. 3).
-
Align the 8-pin male connector with the female receptacle of PDS8/PDS8CB, then mount (Fig. 2, pg. 2, Fig. 3a, pg. 4).
-
Connect the 24VDC power supply to the terminal marked [+ IN1 –] of PDS8/PDS8CB (Fig. 2, pg. 3).
-
Set each output (OUT1-OUT8) on PDS8/PDS8CB to route power from power supply 1 or 2 (jumper positions <1 OFF 2>) (Fig. 3, pg. 4).
Note: Measure output voltage before connecting devices. This helps avoid potential damage. -
Turn the power off before connecting devices.
-
Connect devices to terminal pairs 1 to 8, marked [P (Positive) – OUT1-OUT8, N (Negative)] (Fig. 3, pg. 4). Note: For DC devices carefully observe polarity.
-
After all devices have been connected turn the power on.
Input/Output Chart
Input | 5VDC Output | 12VDC Output |
---|---|---|
24VDC @ 1.75A | 6A max. | N/A |
24VDC @ 3.5A | N/A | 6A max. |
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone:
718-567-8181 | fax:
718-567-9056. website:
www.altronix.com | e-mail:
info@altronix.com | Lifetime Warranty IIVR6 F23U.