Fixture Assembly and Installation

The HINKLEY fixture comes with different stem lengths that can be used to achieve the desired height. Follow the steps below for fixture assembly and installation:

  1. Determine the desired height the chandelier will be installed at.
  2. Choose the appropriate combination of stems to achieve the desired length. Slip stems over wire and thread first stem onto the top of the chandelier. Repeat this process until all required stems are threaded together. See Drawing 1 for reference.
  3. After the last stem is threaded on, slip wire through the center hole in loop (L). See Drawing 2 for reference.
  4. Thread loop (L) onto the top of the last stem and tighten. Now slip wire through the center hole of the loop (T) that is attached to the canopy.
  5. The fixture is now ready for installation. Follow the instructions on I.S.18 instruction sheet provided for wire connections and safety precautions.

Fixture Installation Junction Box
The fixture installation junction box requires two long 8-32 screws, a mounting strap, and two short 8-32 screws. Follow the steps below for installation:

  1. Thread two long 8-32 screws provided into the mounting strap.
  2. Attach mount strap to junction box with two short 8-32 screws (not provided).
  3. Make wire connections following the instructions on I.S.18 instruction sheet provided.
  4. Slip canopy/fixture over screws and secure fixture to ceiling with ball knobs.

Glass Installation
Follow the steps below for glass installation:

  1. Find a clear area to work in and unpack the fixture and glass from the carton.
  2. Carefully review instructions prior to assembly.
  3. Follow instruction sheet IS 29307 supplied for fixture assembly. Make sure to read through all instruction sheets supplied prior to assembling and installing the fixture.
  4. After the fixture is installed, return to this sheet for glass installation instructions.

SAFETY WARNING:
Read wiring and grounding instructions (I.S.18) and any additional directions. Turn power supply off during installation. If new wiring is required, consult a qualified electrician or local authorities for code requirements.

IS 29307 Mounting Instructions

SAFETY WARNING:
READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

  1. Shut off electrical current before starting. If the fixture you are replacing is turned on and off by a wall switch, simply turn the switch off. If not, remove the appropriate fuse (or open the circut breakers) until the fixture is dead.
    DO NOT restore current – either by fuse, breaker or switch – until the new fixture is completely wired and in place.

Fixture Assembly

  1. Determine the desired height the chandelier will be installed at.
  2. The fixture is supplied with a variety of stem lengths. Determine what combination of stems are needed to achieve desired length – see Drawing 1.
  3. Slip stems over wire and thread first stem onto top of chandelier. Repeat this process until all required stems are threaded together.
  4. After last stem is threaded on slip wire through center hole in loop (L) – see Drawing 2.
  5. Thread loop (L) onto top of last stem and tighten. Now slip wire through the center hole of the loop (T) that is attached to the canopy.
  6. Fixture is ready for installation.

Fixture Installation

  1. Thread two long 8-32 screws (1) provided into the mounting strap (2).
    Note: the two screws should be threaded into the gull wing shaped part of the mounting strap with the flat part of the strap facing up. Make sure screws are threaded into holes that line up with the holes in the canopy (3) – see Drawing 3.HINKLEY-29307-Rhodes-1-Light-Outdoor-Hanging-Lantern-
fig-4

  2. Attach mount strap (2) to junction box with two short 8-32 screws (5) (not provided).

  3. Make wire connections following the instructions on I.S.18 instruction sheet provided.

  4. Slip canopy/fixture over screws (1) and secure fixture to ceiling with ball knobs . (4)

Assembly Instructions

  1. Find a clear area in which you can work.

  2. Unpack fixture and glass from carton.

  3. Carefully review instructions prior to assembly.
    Assembly of this fixture will be accomplished by first assembling the main body, then making all necessary electrical connections, hanging the fixture from the ceiling, and then installing the glass.

  4. To assembly your fixture follow instruction sheet IS 29307 supplied. Make sure to read through all instruction sheets supplied prior to assembling and installing your fixture.

  5. After fixture is installed return to this sheet for glass installation instructions.

SAFETY WARNING:
READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

GLASS INSTALLATION
Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections. Then refer back to this sheet to complete installation of this fixture.

  1. To install glass (1) slip small hole in top of class over socket (S) after slipping through bottom of fixture body – see DRAWING 1.
  2. Next slip spacer (3) over socket and then thread on threaded socket ring (2). Making sure threaded top portion of socket ring (2) is facing toward socket spacer (3).
  3. Fixture installation is complete and power can be restored.HINKLEY-29307-Rhodes-1-Light-Outdoor-Hanging-Lantern-fig-5

I.S. 18 wiring grounding instructions

SAFETY WARNING:
READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

wiring instructions
  • Indoor Fixtures
1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
3. Please refer to the grounding instructions below to complete all electrical connections
  • Outdoor Fixtures
1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3.
2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
3. Cover open end of connectors with silicone sealant to form a watertight seal.  

If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.

  • Please refer to the grounding instructions below to complete all electrical connections.
grounding instructions
  • Flush Mount Fixtures
    For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) – see Drawing 1.
    Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.

  • Chain Hung Fixtures
    Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2.

  • Post-Mount Fixtures
    Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.

Outdoor Living Instructions

  • Your Outdoor Living xture will be exposed to the elements.
  • The following steps are to be taken after the xture is installed.
    1. Using an appropriate caulk run a bead around the canopy to seal any gaps between the canopy and the ceiling. – See drawing 1.
    2. Also, add a bead of caulk at the top of the stem where the wire exits from the loop and where the wire enters the loop on the canopy -see drawing 2.