HALCYON R835 Exterior Commercial Recessed Large Low Glare Instruction Manual
- June 10, 2024
- HALCYON
Table of Contents
R835 Exterior Commercial Recessed Large Low Glare
Instruction Manual
R835 Exterior Commercial Recessed Large Low Glare
RISK OF FIRE – Required clearance from structural members and building
elements Side Clearance from heatsink to building element (e.g. timber, joist
or batten) (SCB): 100mm Height Clearance from heatsink to building element
(e.g. timber, joist or batten) (HCB): 100mm
Recessed Luminaire Classification:
NON-IC – A luminaire shall under no circumstances be covered or abutted
with building insulation.
If the external flexible cable or cord of this luminaire is damaged, it shall
be exclusively replaced by the manufacturer or his service agent or a
similarqualified person in order to avoid a hazard.
The light source of this luminaire is not replaceable; when the light source
reaches its end of life the whole luminaire shall be replaced
DO NOT INSTALL THROUGH JOIST, BEAM, RAFTER OR CEILING BATTEN
All exterior luminaires (with the exception of copper) require periodic
cleaning to protect the surface and/or coating from corrosion and ensure tidy
appearance for the lifespan of the product. Wash with care using a soft brush
and warm soapy water using a neutral detergent. Coastal areas require extra
attention, especially fittings which are under eaves/soffits and do not have
any exposure to rain. Do not use a water blaster or high pressure hose, do not
submerge fittings for extended periods of time. 316 stainless steel fittings
will still develop surface rust or “tea staining” if left uncared for.
CLASSIFICATION SHEET / NON-IC
Manufacturer / Supplier | Halcyon Lighting Ltd |
---|---|
Product Code | R835 |
Product Type | LED Recessed Luminaire |
Secondary Voltage | 500mA Constant Current |
Wattage | 17.5W |
Ingress Protection Rating | IP65 |
Classification |
or abutted with building insulation.
---|---|---
DO NOT INSTALL THROUGH JOIST, BEAM, RAFTER OR CEILING BATTEN.
Side Clearance from heatsink to building element (e.g. timber, joist or
batten)| SCB:100mm
---|---
Height Clearance from heatsink to building element (e.g. timber, joist or
batten)| HCB:100mm
Side Clearance from heatsink to insulation| SCI: 100mm
---|---
Height Clearance from heatsink to insulation| HCI: 100mm
Caution: Recessed luminaires and their associated equipment may pose a
risk of fire or damage to property if not installed and maintained correctly.
Halcyon Non IC rated luminaires are completely safe to install in sarked
timber ceiling linings with a gauge of less than 20mm. Halcyon accepts no
responsibility if the timber used is not treated correctly and dries out,
crack or warps over time due to the constant low heat from the aforementioned
“Non IC Rated” LED recessed lighting.
This data sheet contains information necessary to ensure compliance with the
New Zealand Electrical Code of Practice for Installation and Maintenance of
Recessed Luminaires and Associated Equipment AS/NZS 60598.2.2:2001
Documents / Resources
|
HALCYON R835 Exterior Commercial Recessed Large Low
Glare
[pdf] Instruction Manual
R835 Exterior Commercial Recessed Large Low Glare, R835, Exterior Commercial
Recessed Large Low Glare, Large Low Glare
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>