Intesis IN485UNI001I100 Universal IR Air Conditioner to BACnet Modbus Instruction Manual

June 10, 2024
Intesis

Intesis IN485UNI001I100 Universal IR Air Conditioner to BACnet Modbus

Product Information

Universal IR Air Conditioner to BACnet/Modbus

The Intesis IN485UNI001I100 is a gateway device that allows communication between a universal infrared air conditioner and BACnet or Modbus systems. The device has an IR receiver and emitter, RS-485 connector, USB port, temperature probe, humidity sensor, and LED indicator. The gateway must be installed by qualified personnel following all safety instructions provided in the manual.

Product Usage Instructions

  1. Record the serial number of the device located at the rear of the gateway for future reference.
  2. Before installation, ensure that the AC unit is completely disconnected from mains power.
  3. Check the emplacement of the device using the AC IR remote controller to ensure proper control of the AC unit.
  4. The device can be wall or desktop mounted using the built-in DIP-switch block.
  5. To access the DIP-switch block, release the back lid and gently bend both frontal click-fit tabs using a plane tool tip.
  6. Connect the device to the AC unit via the IR receiver and emitter.
  7. Connect the device to BACnet or Modbus systems via the RS-485 connector and USB port.
  8. Use the temperature probe and humidity sensor to monitor and control environmental conditions.
  9. Refer to the LED indicator for status updates on the device.

Safety Instructions

Improper installation of the device may lead to serious harm and damage to the device and other connected equipment. The device must be installed by qualified personnel following all safety instructions provided in the manual. The device must not be installed outdoors or exposed to direct solar radiation, moisture, or dust.

Owner’s Record
The serial number is located at the rear of the gateway.
Record this information in the space provided below.
Refer to it whenever you contact upon your gateway dealer or support team regarding this product.
Serial No. …………..

PRODUCT OVERVIEW

Intesis IN485UNI001I100 Universal IR Air Conditioner to BACnet Modbus-
FIG2

SAFETY INSTRUCTIONS

WARNING – Follow this safety and installation instructions carefully. Improper work may lead to serious harm to your health and may seriously damage the Intesis gateway and/or any other equipment connected to it.
This Intesis interface must be installed by qualified personnel, following all the safety instructions given here and in accordance with local regulations for electrical equipment. The Intesis gateway cannot be installed outdoors or exposed to direct solar radiation, moisture or dust.
Before manipulating the indoor AC unit, be sure it is completely disconnected from mains power.

DIP-switch block

To access the built-in DIP-switch block, open the enclosure by releasing the back lid. Gently bend both frontal click-fit tabs by inserting a plane tool tip (size <5 mm). This operation must be performed by qualified personnel only

INSTALLATION

Intesis IN485UNI001I100 is intended for wall / desktop mount.

  1. Check device emplacement using your Air Conditioner IR remote controller. Make sure that you can control the AC unit properly with the IR remote controller from that location. Different emplacements are acceptable, as shown in figures below

  2. Connect the RS-485 bus cable to built-in RS-485 3-pin screw terminal block. Notice terminals A (+), B (-) and SG (ground)

  3. Connect supplied USB cable to USB built-in connector (mini B type), for power supply and communication with config tool

TECHNICAL SPECIFICATIONS

Enclosure

| Plastic, type PC (UL 94 V-0)

Net dimensions (dxwxh): 93 x 58.5 x 21 mm / 3.7” x 2.3” x 0.83”

Color: Light Grey. NCS S 1002-B

|

Operating Temperature

|

0ºC to +60ºC

---|---|---|---

Weight

| 55 g.| Storage Temperature| -20ºC to +85ºC

Mounting

| Wall

On a clean surface (desktop…)

| Operating Humidity| 5% to 95% RH, non-condensing

Terminal Wiring

| For terminal: solid wires or stranded wires (twisted or with ferrule)

1 core: 0.25mm2… 1mm2

2 cores: 0.25mm2… 0,75mm2 3 cores: 0.25mm2… 0,75mm2

|

Storage Humidity

|

<95% RH, non-condensing

EIA-485

| 1 x EIA485 Plug-in screw terminal block (3 poles):

Signal Ground: SG / SGND Data positive: A/+

Data negative: B/-

|

Protection

|

IP20 (IEC60529)

USB port| 1 x Standard mini USB, 5VDC. Consumption max. 400mA|

LED indicators

|

1 x external LED – Operational status

Buttons| 1 x button|
Power Supply| 5VDC 0,4A NEC Class 2 or Limited Power Source (LPS) and SELV rated Power supply|

This marking on the product, accessories, packaging or literature (manual) indicates that the product contains electronic parts and they must be properly disposed of by following the instructions at https://intesis.com/weee- regulation

© HMS Industrial Networks S.L.U. – All rights reserved
This information is subject to change without notice

https://www.intesis.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Intesis User Manuals

Related Manuals