escea EW5000 Outdoor Wood Cooking Fireplace Instruction Manual
- June 10, 2024
- escea
Table of Contents
EW5000 Outdoor Wood Cooking Fireplace
Product Information
- The EW5000 is a wood-burning barbecue and outdoor fire designed for outdoor use only.
- The appliance dimensions are 996mm in width, 758mm in height, and 548mm in depth. It weighs 90.3kg.
- The flue has a diameter of 250mm OD and the minimum internal cavity dimensions for a concrete or concrete block structure are 1077mm in width and 835mm in depth.
- The minimum AAC heat cell dimensions for a timber or combustible structure are 1200mm in width, 950mm in height, and 735mm in depth. The minimum cavity dimensions are 1270mm in width, 1550mm in height, and 770mm in depth.
- For installations with a fascia, the firebox must be flush with the front face of the concrete structure to allow the fascia to engage with the fascia brackets. The user should ensure that the installation complies with all local and national codes.
Product Usage Instructions
-
The EW5000 is designed for outdoor use only.
-
The firebox and flue system can be installed into a remote, free-standing, fully non-combustible fireplace construction on all surfaces surrounding the fireplace and flue. Example materials that can be used include solid concrete, concrete/masonry blocks, bricks, or Hebel blocks/panels. Do not use timber framing.
-
Any cladding over the front of the structure (not including the chimney chase structure) must consist of a heat-resistant material.
Cladding over any other surface of the structure can consist of a combustible material (e.g. plywood). -
Depending on the material choice, some heat may be conducted through the surrounding cavity, and consequently, no combustible materials should come into contact with these hot surfaces.
-
For concrete or concrete block structure, the minimum cavity dimensions are 1077mm in width and 835mm in depth. For timber or combustible structure, the minimum AAC heat cell dimensions are 1200mm in width, 950mm in height, and 735mm in depth.
-
For installations with a fascia, the firebox must be flush with the front face of the concrete structure to allow the fascia to engage with the fascia brackets. Use the provided holes in the base to fix the firebox firmly down.
-
Ensure that the installation complies with all local and national codes.
-
For further information or specifications, visit the technical section of our website www.escea.com to view the latest product Installation Manual.
Appliance Information
Specifications
- Appliance Dimensions(mm) 996W x 758H x 548D
- Appliance Weight 90.3kg
Concrete or Concrete Block Structure
Minimum Internal Cavity Dimensions (mm):| 1077W x 835D
Timber or Combustible Structure
Minimum AAC Heat Cell Dimensions (mm):| 1200W x 950H x 735D
Minimum Cavity Dimensions (mm):| 1270W x 1550H x 770D
NOTE: For Concrete or Concrete Block Structure Height dimension depending on the installation method, please see the Installation Manual for details.
Cavity Construction
Minimum Requirements of Concrete | Concrete Block Structure
This appliance is designed for outdoor use ONLY.
The firebox and the flue system can be installed into a remote, free-standing, fully non-combustible fireplace construction on all surfaces surrounding the fireplace and flue. Example materials that can be used include: solid concrete, concrete/masonry blocks, bricks, or Hebel blocks/panels. Do not use timber framing.
For installations with a fascia, the position of the firebox must be located so that the appliance base is flush with the front face of the concrete structure. This is to allow the fascia to engage into the fascia brackets. Use the provided holes in the base to fix the firebox firmly down.
Depending on material choice, some heat may be con-ducted through the surrounding cavity and consequently no combustible materials should come into contact with these hot surfaces. This is completely dependant on the chosen material and design of installation. The user should satisfy themselves that the installation is fit for purpose and complies with all local and national codes.
Corner installation
Minimum Requirements of the Timber | Combustible Structure
This appliance is designed for outdoor use ONLY.
It can also be installed within a free-standing timber/combustible cavity. The cavity structure must be free-standing and must not be connected to the envelope of a building. However, the cavity can penetrate through a combustible roof structure. The roof structure may be attached to a building.
For this scenario, the appliance must be enclosed within an Autoclaved Aerated Concrete (AAC) heat cell with a minimum thickness of 75mm thick panels having a thermal resistance/ R-value of no less than 0.59m2 K/W. Additionally, the appliance must be installed with the EW Heat Cell Dropbox.
This scenario must be supplied with the triple skinned EW5000 Timber Cavity Flue Kit. The appliance must be frameless for this install scenario as the optional fascia is not compatible with this installation type.
Any cladding over the front of the structure (not including the chimney chase structure) must consist of a heat resistant material. Cladding over any other surface of the structure can consist of a combustible material (eg. plywood).
Flue Information
Flue Specifications for the Concrete | Concrete Block Structure
Flue Specifications for the Timber | Combustible Structure
NOTE: The appliance & flue system shall be installed in accordance with
AS/NZS 2918 and these specifications.
NOTE: The flashing requirements must comply with the Installation Manual
relevant section D3 on page 12 or E4 on page 21, depending on the installation
method of choice.
Venting & Sealing Requirements
The venting and sealing requirements must comply with the Installation Manual
relevant section D1 and D2 on page 11 or section E2 and E3 on page 16,
depending on the installation method of choice.
Clearances
External Clearances to Combustible Surfaces
The cavity structure must comply with the minimum requirements as stated on
the previous page depending on the installation method of choice.
SIDE VIEW
TOP VIEW
630472_4 EK1550 Builders and Architects Sheet