SEAGATE G265 VSS Hardware Provider Installation Guide
- June 10, 2024
- Seagate
Table of Contents
- SEAGATE G265 VSS Hardware Provider
- Product Information
- Product Intended Audience
- Product Prerequisites
- Product Document Conventions and Symbols
- Product Usage
- About this guide
- The VSS Hardware Provider and the CAPI Proxy
- Installing and using the VSS Hardware Provider
- Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SEAGATE G265 VSS Hardware Provider
Product Information
VSS Hardware Provider Installation Guide
The VSS Hardware Provider Installation Guide provides installation and
usage instructions for the VSS Hardware Provider that works with Microsoft
Windows Server and Seagate storage systems. It also includes installation
instructions for the CAPI Proxy that must be installed to enable support for
the VSS Hardware Provider.
Product Intended Audience
This guide is intended for system administrators and storage administrators.
Product Prerequisites
Before using this product, users should have knowledge of:
- Hardware Installation and Maintenance Guide
- Release Notes
Product Document Conventions and Symbols
Convention | Description |
---|---|
Colored text | Important information |
Black, underlined text | Links to important information |
Colored, underlined text | Links to additional information |
Bold text | Instructions and important notes |
Italic text | Emphasis on specific words or phrases |
Monospace text | Commands, paths, and file names |
Monospace, italic text | User input or output |
Monospace, bold text | Error messages or warnings |
CAUTION: | Indicates that failure to follow directions could result in |
damage to equipment or data.
IMPORTANT:| Provides clarifying information or specific instructions.
NOTE:| Provides additional information.
TIP:| Provides helpful hints and shortcuts.
Product Usage
VSS Hardware Provider Installation Guide
Step 1: Installing the CAPI Proxy
Before installing the VSS Hardware Provider, you must first install the
CAPI Proxy on all hosts that will run the VSS Hardware Provider. Follow these
steps:
- Download the CAPI Proxy installation file.
- Run the installation file.
- Follow the on-screen instructions to install the CAPI Proxy.
- Restart your computer after installation is complete.
Step 2: Installing and Using the VSS Hardware Provider
After installing the CAPI Proxy, you can now install and use the VSS
Hardware Provider. Follow these steps:
- Download the VSS Hardware Provider installation file.
- Run the installation file.
- Follow the on-screen instructions to install the VSS Hardware Provider.
- To use the VSS Hardware Provider, refer to the Seagate storage systems documentation for information on how to configure VSS.
Note: For more detailed information on installation and usage of the VSS Hardware Provider and CAPI Proxy, refer to the VSS Hardware Provider Installation Guide.
Abstract
This document provides installation and usage instructions for the VSS
Hardware Provider that works with Microsoft Windows Server and Seagate storage
systems. It also includes installation instructions for the CAPI Proxy, which
must be installed to enable support for the VSS Hardware Provider.
About this guide
This document provides installation and usage instructions for the VSS Hardware Provider that works with Microsoft Windows Server and Seagate storage systems. It also includes installation instructions for the CAPI Proxy that must be installed to enable support for the VSS Hardware Provider.
Intended audience: This guide is intended for system administrators and
storage administrators.
Prerequisites: Prerequisites for using this product include knowledge of:
- Server system administration
- Microsoft Windows servers
- Storage system configuration
- Storage area network (SAN) management
- Fibre Channel (FC) protocol
- Serial Attached SCSI (SAS) protocol
- Internet SCSI (iSCSI) protocol
Before you begin to follow procedures in this guide, you must have already installed enclosures and learned of any late-breaking information related to system operation, as described in the Hardware Installation and Maintenance Guide and in Release Notes.
Document conventions and symbols
Table 1 Document conventions
Convention | Element |
---|---|
Colored text | Cross-reference links |
Black, underlined text | Email addresses |
Colored, underlined text | Website addresses |
Bold text | • Keys that are pressed |
• Text typed into a GUI element, such as a box
• GUI elements that are clicked or selected, such as menu and list items, buttons, and check boxes
Italic text| Text emphasis
Monospace text| • File and directory names
• System output
• Code
• Commands, their arguments, and argument values
Monospace, italic text| • Code variables
• Command variables
Monospace, bold text| Emphasis of file and directory names, system output, code, and text typed at the command line
- CAUTION: Indicates that failure to follow directions could result in damage to equipment or data.
- IMPORTANT: Provides clarifying information or specific instructions.
- NOTE: Provides additional information.
- TIP: Provides helpful hints and shortcuts.
The VSS Hardware Provider and the CAPI Proxy
The VSS Hardware Provider and CAPI Proxy described in this document are used with Seagate 5005/4005 Series storage systems in Microsoft Windows Server environments. They are available for download as separate installation files:
- A VSS Hardware Provider for FC, iSCSI, and SAS storage systems.
- A CAPI Proxy that enables in-band management from host-based applications. The CAPI Proxy is necessary to enable the VSS Hardware Provider. It must be installed on all hosts that will run the VSS Hardware Provider.
Version 3.8 of the VSS Hardware Provider and CAPI Proxy are to be used with
Seagate 5005/4005 Series and newer storage systems.
If any of the providers on a host are upgraded to 3.8, all other Hardware
Providers and the CAPI Proxy installed on the host must be upgraded to the
same version.
IMPORTANT: In environments with Seagate 5005/4005 Series systems using FC and iSCSI host interface ports in combination, do not connect both iSCSI and FC ports from the same controller to the same host.
Table 2 Compatible versions of software
VSS and CAPI Proxy versions: | Applies to product family: |
---|---|
Seagate v.3.8 | Seagate 5005 Series |
Seagate 4005 Series
Installation requirements
Each of the software components described in this document can be
downloaded from the support website seagate.com/support-
home.
All VSS/CAPI packages are typically included in a single archive file, such as
seagate-vss-3.8.x.xx.zip, which in turn contains .zip files for each
individual component. Several server-specific files might be available on the
support website. If multiple versions are available, they will be identified
by a filename suffix such as x64 or x86. Be sure to download the appropriate
.zip file for the server on which you will be installing the VSS Hardware
Provider.
The VSS Hardware Provider requires the following software:
- A supported operating system:
- Microsoft Windows Server 2012 x64 Edition
- Microsoft Windows Server 2012 R2 x64 Edition
- Microsoft Windows Server 2016
- CAPI Proxy 3.8 or later
About VSS
Microsoft Windows Server operating systems provide enhanced services for
managing storage area networks, including Volume Shadow Copy Service (VSS).
VSS, with its standard set of extensible APIs, provides the backup
infrastructure for Windows Server, as well as a mechanism for creating
consistent point-in-time copies of data known as shadow copies. VSS provides
interfaces to ensure that volume shadow copies are in a consistent state.
The VSS Hardware Provider installs on a server running Windows Server and enables VSS to create hardware-resident shadow copies on any storage system attached to the server. With the VSS Hardware Provider and VSS, you can create a shadow copy of the source data volume on one server and then import the shadow copy onto another server, or back to the same server. Before creating the shadow copy, determine whether it will be imported back to the same host, because a snapshot created with the transportable option should not be imported back to the original host.
The VSS Hardware Provider does not include user interfaces or standalone functionality. Instead it enables other applications to manage Seagate storage products. vshadow.exe and diskshadow.exe are useful command-line tools for creating, deleting, querying, and managing shadow copies in a Microsoft Windows environment. Diskshadow is included in Windows Server, while VShadow is available from Microsoft as part of the Windows SDK.
Supported VSS features
The VSS Hardware Provider supports the following features provided by the
Windows VSS subsystem:
-
Creating shadow copies/snapshots.
NOTE: Before you can create shadow copies, a license key must be installed in the storage system to enable snapshot functionality for virtual volumes. Then you must enable shadow copies for a volume by using your configuration management tool. See “Creating shadow copies” (page 8) for more information. -
Exporting shadow copies/snapshots: prepare for use in another Windows Server system.
-
Importing snapshots: prepare for local use after export from another Windows Server system.
-
Determining when snapshots can be deleted and deleting them.
-
Reverting snapshots using the diskshadow resync command or vshadow -resync option.
Installing the CAPI Proxy
The CAPI Proxy is a prerequisite for the VSS Hardware Provider. Install it before installing the VSS Hardware Provider.
-
Download the single archive file described above.
-
Extract and open the CAPI Proxy setup file to begin the installation.
NOTE: The CAPI Proxy setup.exe can be launched directly from within the archive file without extracting the other files if desired. -
Follow the on-screen prompts to install the software.
On 32-bit operating systems, the software program is installed in:
C: \Program Files\Seagate\Seagate CAPI Proxy
On 64-bit operating systems, the software program is installed in:
C: \Program Files(x86)\Seagate\Seagate CAPI Proxy
If a previous version of the CAPI Proxy is already installed, a message informs you that the software is installed, but not up to date. -
Press Yes to continue with the installation process, or No to exit setup.
Installing and using the VSS Hardware Provider
This section describes how to install the VSS Hardware Provider.
NOTE: In a cluster environment the VSS Hardware Provider cannot be installed unless a Microsoft Distributed Transaction Coordinator (MS DTC) cluster resource is configured. If the host part of a cluster and MSDTC is not running, installation will fail. Refer to http://support.microsoft.com/kb/301600 for instructions on configuring MS DTC.
-
Double-click the downloaded Hardware Provider file to launch the installation.
-
Press the Install button.
-
Follow the onscreen prompts to install the software.
The provider is installed in this directory:
C: \Program Files\Seagate\Seagate VSS Provider
If a previous version of the VSS Hardware Provider is already installed, a message tells you that the software is installed, but not up to date.
NOTE: Overwriting an existing VSS Hardware Provider will not overwrite previously installed hardware providers used with earlier storage systems. -
To verify the installation, run the list providers command, and make sure that the VSS Hardware Provider is displayed in the list of providers.
Creating shadow copies
VSS functionality includes creating, deleting, and managing shadow copies. To create a shadow copy of a volume in a virtual pool, create the shadow copy using a VSS requester such as Diskshadow (included in Windows Server 2012 and Windows 2016) or VShadow (available as a download from microsoft.com as part of the Windows SDK).
NOTE: After the VSS Hardware Provider is installed, your backup software may take advantage of it to create temporary hardware snapshots on the system when your backups are run.The VSS Hardware Provider takes shadow copies quickly (less than 5 seconds), but the Microsoft VSS subsystem can take a long time to recognize and import the new shadow copies. It may take up to 90 seconds to create and import a shadow copy. It takes longer if multiple RAID partitions are included in the same shadow copy set.
LUN 0 mapping
For best performance, avoid mapping any storage system volumes to the host
using LUN number 0, which is used by the VSS Hardware Provider to monitor and
manage the system. The VSS Hardware Provider automatically assigns LUN numbers
starting at LUN 1, but if you have manually mapped LUNs to the host using LUN
number 0, the providers have to compete with I/O traffic and this may cause
commands to run more slowly or time out.
64-bit VSS clients
When creating snapshots on a 64-bit OS, you must use a 64-bit VSS client
application. Microsoft’s VSS framework does not support 32-bit requestors on
64-bit operating systems.
Ensuring read-write access of VSS shadow copies
When VSS creates a shadow copy, it maps the LUN with the shadow copy data
back to the host. Because this is generally used for backup, the volumes on
the LUN are read-only. The LUN is mapped read-write; only the volumes are
read-only. You can restore read-write access of the volumes on the server, as
shown below.
NOTE: Multiple terms for the same or similar storage elements can include disks, volumes, snapshots and LUNs, depending on whether the storage element is being referenced by an operating system, a storage device, or an application.
The read-only or read-write attribute may also be influenced by the SAN policy
of Windows Server systems. The SAN policy in place on the server affects the
access level for newly discovered disks, but volumes on the disks for VSS
shadow copy snapshots are always initially discovered as read-only, regardless
of the SAN policy or version of Windows operating system.
See “LUN 0 mapping” (page 9) for more information.
Restoring read-write access
On the server, clear the read-only status of the imported snapshots’ disks and
volumes using the commands below. Select the disk that corresponds to the LUN
with the snapshot data. After selecting the disk and clearing the disk’s read-
only status, select the volume and clear the volume’s read-only status.
Relative to the tables below, invoke the Microsoft DiskPart utility by typing
diskpart at the command line. Once invoked, DISKPART> appears as a prompt for
entering the commands listed in the tables below. Type exit to quit the
Microsoft DiskPart utility.
Table 3 DiskPart utility – disk commands
Command/sequence | Description |
---|---|
1 | list disk |
following command.
2| select disk x| Selects a disk where x refers to the disk number from the
list disk command.
3| detail disk| Use command to verify the disk is in an offline and/or read-
only state.
4| online disk| Use command to bring the selected disk online.
Command/sequence| Description
---|---
5| attributes disk clear readonly| Clears the readonly attribute, allowing
this host to write to the disk.
6| list volume| Allows you to get a list of volumes residing on disk, if any.
The volume number displayed will be used in the select volume command.
The commands in the following table are repeated for each volume on the LUN; typically, there will be only one volume—or none—for a newly-provisioned LUN.
Table 4 DiskPart utility – volume on LUN commands
Command/sequence | Description |
---|---|
1 | select volume y |
the list volume
command.
2| detail volume| Use command to verify the volume is read-only.
3| attributes volume clear readonly| Clears the readonly attribute for the
volume.
Troubleshooting
This section contains troubleshooting information for the VSS Hardware Provider.
Table 5 Troubleshooting the VSS Hardware Provider
Issue | Description |
---|
The VSS Hardware Provider cannot create a snapshot.
The following error is reported:
VSS_E_PROVIDER_VETO
| • The maximum number of snapshots allowed by the snapshot license has
already been created.
• The storage system has failed to execute the commands from the VSS
Hardware Provider, or the communication between the VSS Hardware Provider and
the system is broken, due to any of the following conditions:
¢ The serial number cannot be obtained for the controller owning the volume.
¢ The snapshot cannot be found in the VSS Hardware Provider’s snapshot list.
¢ The partition is not a snapshot.
¢ The LUN assignment to the newly created snapshot failed.
¢ The snapshot that will be deleted is not a Seagate snapshot.
¢ A firmware upgrade operation may temporarily prevent VSS from managing the system.
The shadow copy does not exist on the controller.| • The backup utility
automatically deletes the shadow copy when the backup is complete.
• You might have used the Windows Explorer shadow copy shell extension
context menu to create a shadow copy, which is to be used for creating a
Windows software shadow copy, not hardware shadow copies.
• Make sure you have created the shadow copy using the persistent (-p)
attribute.
Issue| Description
---|---
| • If you use the Vssadmin tool from Microsoft to create shadow copies,
it is not designed to work with the VSS Hardware Provider. Vssadmin create
shadow only works with the Microsoft software shadow copy provider built into
Windows.
An application error in the Windows event log states:
ssproxy requires that the HBA can handle 256-Kbyte transfers. You might need to set the MaximumSGList to a value of 65 or higher if using a SCSIPort driver.
| The CAPI Proxy requires the maximum data for the CAPI command to be 256 Kbyte. This does not apply to Storport HBA drivers.
• For SCSIport HBA drivers, create a MaximumSGList registry entry if it does not already exist and set it to a value of 65 or higher, if it has not already been set.1
Note: The SCSIport host-bus adapter driver has been removed in Windows Server 2012. Instead, use either a Storport driver or a different host-bus adapter.
• To set the registry for Qlogic cards using the SCSIport driver, double-
click qla2300.reg in the following directory: C:\Program Files\Seagate\Seagate
VSS Provider\ qla2300.reg
It is taking a long time to create the shadow copy.| The VSS Hardware Provider
takes shadow copies quickly (less than 5 seconds), but the Microsoft VSS
subsystem can take a long time to recognize and import the new shadow copies.
It may take up to 90 seconds to create and import a shadow copy. It takes
longer if more RAID partitions are included in the same shadow copy set.
Not Implemented or 0x80004001 error when revert command used in VShadow or
Diskshadow.| The revert option is meant for host-based snapshots and is not
supported for storage system-based snapshots. Use the resync command instead.
VSS_E_MISSING_DISK error when using the
RESYNC command
| This error can occur if the target volume is in use when the RESYNC command
is issued. The target volume may be left in an offline state; use Disk
Management or DISKPART to bring the target volume back online. To minimize the
likelihood of this error occurring, stop the VSS subsystem with the
command NET STOP VSS prior to performing the RESYNC operation; the VSS
subsystem will automatically restart when you launch a VSS client. If
necessary, use MOUNTVOL to unmount the volume prior to issuing the RESYNC
command to ensure that other applications are not accessing the volume.
VSS_E_PROVIDER_VETO error when using the
RESYNC command
| This error can occur if a previous operation in the system is still in
progress and the resync operation cannot proceed. The target volume may be
left in an offline state; use Disk Management or DISKPART to bring the target
volume back online. Review the event log in the system and wait for any
operation in progress to complete before retrying the operation.
A “0mb” volume may appear in the Disk Management applet after creating a
hardware snapshot of a GPT-formatted volume.| The Disk Management Control
Panel applet may display an unnamed volume with a capacity of 0mb after a
snapshot is created on a GPT disk. These are associated with special metadata
partitions that Windows creates as part of the snapshot process and may safely
be ignored. If they are bothersome, they can be deleted using the DISKPART
command, by looking for a 256KB partition with an “Unknown” partition type.
Volumes formatted with a traditional MBR partition table are not affected.
Uninstalling the VSS Hardware Provider
To uninstall the VSS Hardware Provider, perform the following steps.
- Choose Start > Control Panel > Add/Remove Programs or Start > Control Panel > Programs and Features.
- Choose VSS Hardware Provider and click Change/Remove.
- Respond appropriately to the prompts.
- You can also select the CAPI Proxy from the Add/Remove Programs list if you do not need it to enable the VSS Hardware Provider for which it is a prerequisite, and uninstall it now.
References
- Microsoft Corporation
- Registry Entries for SCSI Miniport Drivers - Windows drivers | Microsoft Learn
- Seagate Support | Support Seagate US
- Seagate Support | Support Seagate US
Read User Manual Online (PDF format)