u-blox G7 Blackline Safety User Manual
- June 10, 2024
- u-blox
Table of Contents
G7 Blackline Safety
G7 Technical User Manual
The G7 is a safety device that connects to the Blackline Safety
Network and is available in two models: G7c and G7x. The G7c
connects to the network via cellular coverage, while the G7x uses a
portable satellite base station for remote locations outside
cellular coverage. The device comes with one of four cartridge
types: Standard, Single-gas, Multi-gas diffusion, and Multi-gas
pump cartridges. The device has an LCD display and a three-button
menu system for interaction.
Device Comparison
Feature | Standard | Single-gas | Multi (diffusion) | Multi (pump) |
---|---|---|---|---|
Text messaging | ✓ | ✓ | ✓ | ✓ |
Fall detection | ✓ | ✓ | ✓ | ✓ |
No-motion detection | ✓ | ✓ | ✓ | ✓ |
SOS alert | ✓ | ✓ | ✓ | ✓ |
Check-in timer | ✓ | ✓ | ✓ | ✓ |
Configuration modes | ✓ | ✓ | ✓ | ✓ |
Receive voice calls* | ✓ | ✓ | ✓ | ✓ |
Push-to-talk enabled* | ✓ | ✓ | ✓ | ✓ |
Single gas detection | ✓ | |||
Multi-gas detection | ✓ | ✓ | ||
Pump enabled | ✓ | |||
Low warning alarm for gas | ✓ | ✓ | ✓ | |
Under limit alarm for gas | ✓ | ✓ | ✓ | |
High alert for gas | ✓ | ✓ | ✓ | |
STEL alert for gas | ✓ | ✓ | ✓ | |
TWA alert for gas | ✓ | ✓ | ✓ | |
Over limit alert for gas | ✓ | ✓ | ✓ |
What’s in the Box
The device comes with either a Single-gas or Multi-gas
cartridge, along with a calibration cap (depending on cartridge)
and calibration gas tubing.
Hardware Details
The device has a latch that can be pulled down to call for help
and pushed in to check-in and indicate safety. The device can be
charged using the removable charging clip and micro USB plug.
Usage Instructions
-
Identify your G7 model by referring to the logo on the front of
the device. -
Familiarize yourself with the interaction buttons on the
device: OK, Up and down arrow buttons, Latch pull, and Latch push
button. -
Charge your G7 using the provided charging clip and micro USB
plug. -
Select the appropriate cartridge for your needs (Standard,
Single-gas, Multi-gas diffusion, or Multi-gas pump cartridges) and
install it into your device. -
If you have a Single-gas or Multi-gas cartridge, calibrate it
using the calibration cap and calibration gas tubing provided. -
To call for help, pull down the latch. To check-in and indicate
safety, push in the latch. -
If you have a G7c model device with voice capabilities, you can
receive voice calls and use push-to-talk functionality. -
If you have a G7x model device, ensure that it is within 2km of
the G7 Bridge portable satellite base station to maintain
connectivity.
G7
Technical User Manual
CONTENTS
OVERVIEW ……………………………………………………………………………………………………………………………………….6 BLACKLINE
SAFETY CLOUD…………………………………………………………………………………………………………6 BLACKLINE LIVE WEB
PORTAL…………………………………………………………………………………………………….6 G7 MODELS
…………………………………………………………………………………………………………………………………8 DEVICE COMPARISON
…………………………………………………………………………………………………………………9 WHAT’S IN THE BOX
…………………………………………………………………………………………………………………. 10 HARDWARE
DETAILS………………………………………………………………………………………………………………… 11
INTERACTION……………………………………………………………………………………………………………………………….. 12 HOW IT
WORKS………………………………………………………………………………………………………………………… 12
OPERATION ………………………………………………………………………………………………………………………………….. 13 CHARGING
……………………………………………………………………………………………………………………………….. 13 WEARING
………………………………………………………………………………………………………………………………….. 13 POWER
ON……………………………………………………………………………………………………………………………….. 13 POWER
OFF………………………………………………………………………………………………………………………………. 14 CONNECTIVITY
LIGHT………………………………………………………………………………………………………………. 14 USING G7’S CONVENIENCE
FEATURES …………………………………………………………………………………… 15
Time………………………………………………………………………………………………………………………………………. 15 Timer
…………………………………………………………………………………………………………………………………….. 17 Stopwatch
…………………………………………………………………………………………………………………………….. 18 VIEWING G7’S ASSIGNED
USER……………………………………………………………………………………………….. 20
GAS DETECTION…………………………………………………………………………………………………………………………… 21 BUMP TEST
………………………………………………………………………………………………………………………………. 21
CALIBRATION……………………………………………………………………………………………………………………………. 23 BUMP TEST AND
CALIBRATION REMINDER WINDOW……………………………………………………………. 24 BUMP TEST AND
CALIBRATION LOCK …………………………………………………………………………………….. 24 ZERO
SENSORS………………………………………………………………………………………………………………………… 25 PID TARGET GASES
………………………………………………………………………………………………………………….. 25
3 ||G7 TECHNICAL USER MANUAL
GAS ALERT COUNTDOWN……………………………………………………………………………………………………….. 26 USING G7
SENSORS IN COLD WEATHER………………………………………………………………………………… 27 GAS ALARMS AND
ALERTS ………………………………………………………………………………………………………….. 28 YELLOW WARNING ALARM GAS
FEATURES ……………………………………………………………………………. 28
Low Warning Alarm for Gas …………………………………………………………………………………………………. 28 Sensor
Under Limit………………………………………………………………………………………………………………. 29 Sensor Error
…………………………………………………………………………………………………………………………. 29 Pump
Block…………………………………………………………………………………………………………………………… 29 RED ALERT GAS
FEATURES………………………………………………………………………………………………………….. 30 HIGH ALERT FOR
GAS………………………………………………………………………………………………………………. 30 CONFIGURATION
MODES……………………………………………………………………………………………………………. 32 AVAILABLE
MODES…………………………………………………………………………………………………………………… 32 ENTERING A MODE
………………………………………………………………………………………………………………….. 33 EXITING A
MODE………………………………………………………………………………………………………………………. 33 CARTRIDGES
………………………………………………………………………………………………………………………………… 35 GAS CARTRIDGE REPLACEMENT
PROGRAM …………………………………………………………………………… 35 CHANGING CARTRIDGES
…………………………………………………………………………………………………………. 35 CARTRIDGE
CARE……………………………………………………………………………………………………………………… 35 LEL SENSOR PRECAUTIONS
…………………………………………………………………………………………………….. 36 LEL LATCHING
ALARM……………………………………………………………………………………………………………… 37 MULTI-GAS PUMP
CARTRIDGE………………………………………………………………………………………………… 38 PUMP OPTIONS
…………………………………………………………………………………………………………………………… 40 REAL-TIME FEATURES
………………………………………………………………………………………………………………….. 41 LOWER URGENCY ALARMS
……………………………………………………………………………………………………… 41 YELLOW WARNING ALARM FEATURES
……………………………………………………………………………………. 43 YELLOW PENDING ALARM FEATURES
…………………………………………………………………………………….. 45 RED ALERT FEATURES
……………………………………………………………………………………………………………… 46 LIVERESPONSE LIGHT
……………………………………………………………………………………………………………… 48 PUSH-TO-TALK (PTT)
………………………………………………………………………………………………………………… 48
Transmitting………………………………………………………………………………………………………………………….. 48 Receiving
………………………………………………………………………………………………………………………………. 49
4 ||G7 TECHNICAL USER MANUAL
Available Channels ……………………………………………………………………………………………………………….. 49 Changing
Channels ………………………………………………………………………………………………………………. 49 Changing Volume
…………………………………………………………………………………………………………………. 50 PTT Audio
accessories………………………………………………………………………………………………………….. 50 OVER-THE-AIR (OTA)
FIRMWARE UPDATES …………………………………………………………………………….. 52 SUPPORT
……………………………………………………………………………………………………………………………………… 53 LEARN MORE
……………………………………………………………………………………………………………………………. 53 CUSTOMER
CARE……………………………………………………………………………………………………………………… 53
SPECIFICATIONS…………………………………………………………………………………………………………………………… 54 DETAILED
SPECIFICATIONS ……………………………………………………………………………………………………… 54 LEGAL NOTICES AND
CERTIFICATIONS ………………………………………………………………………………………. 56 LEGAL NOTICES
……………………………………………………………………………………………………………………….. 56 INTRINSICALLY SAFE
CERTIFICATION………………………………………………………………………………………. 58
5 ||G7 TECHNICAL USER MANUAL
OVERVIEW
BLACKLINE SAFETY CLOUD
How am I connected? The Blackline Safety Network is a cloud-hosted system
comprised of 3G/4G cellular networks, satellite networks, our Blackline LiveTM
web portal application, your monitoring account and your G7. G7 devices
require an active service plan in order to connect to the Blackline Safety
Network. Depending on your needs and requirements, various service plan
options are available such as 24/7 safety monitoring by Blackline’s Safety
Operations Center and two-way voice communication. Contact your organization’s
safety professional for more information regarding the details of your service
plan.
BLACKLINE LIVE WEB PORTAL
What is Blackline Live? G7 utilizes the cloud-hosted Blackline Live web portal
to monitor and manage all your workers and devices, as well as deliver reports
and business analytics insights. With Blackline Live’s real-time alerting and
live map with employee locations, you can quickly locate and respond to a
worker in distress. Real-time alerts show the employees’ location on the map
with the type of alert, enabling your team to efficiently send help. Blackline
Live also allows you to create and customize configuration profiles that
determine how a device or a group of devices operates in the field.
6 ||G7 TECHNICAL USER MANUAL
Similarly, alert profiles are set up to determine what contacts should be
notified in the event of an incident and what response protocol monitoring
personnel will follow to ensure your team gets the help it needs. Blackline
Live keeps track of alert history, calibrations and bump tests, eliminating
the need to manually retrieve data logs from the field. Blackline Live allows
you to tailor user access depending on employee roles: employee, supervisor,
administrator and monitoring team. This ensures that everyone has access to
the right tools to accommodate their role in a comprehensive monitoring
program. What is Blackline Analytics? With Blackline Analytics, review data
collected from your device fleet to make decisions, follow up with your team
and ensure everything is running smoothly. Choose from a number of different
reports and filters to explore your data. Blackline Analytics is built
directly into the Blackline Live portal, allowing anyone with login access to
see their own organization’s data, as well as client data. If users have only
been given access to specific groups of devices, they will only see data
attached to those particular devices.
7 ||G7 TECHNICAL USER MANUAL
G7 MODELS
There are two G7 models: G7c and G7x. The main difference between them is how
they connect to the Blackline Safety Network. If you are unsure of which G7
model you have refer to the logo on the front of your device.
G7c works anywhere with 3G/4G cellular coverage in over 200 countries to connect you directly to the Blackline Safety Network. Depending on your service plan, your G7c may have two-way voice capabilities.
G7x works in conjunction with Blackline’s G7 Bridge — a portable satellite base station that keeps you connected in remote locations outside cellular coverage. G7x uses a 900 MHz radio to communicate with G7 Bridge up to 2km away. One G7 Bridge can link up to five G7x devices to the Blackline Safety Network through Iridium satellite or cellular data.
8 ||G7 TECHNICAL USER MANUAL
DEVICE COMPARISON
G7c and G7x are customized with one of four cartridge types. Cartridge
selections include Standard, Single-gas, Multi-gas diffusion and Multi-gas
pump cartridges. The following comparison chart summarizes the features of
each cartridge.
Text messaging Fall detection No-motion detection SOS alert Check-in timer
Configuration modes Receive voice calls Push-to-talk enabled Single gas
detection Multi-gas detection Pump enabled Low warning alarm for gas Under
limit alarm for gas High alert for gas STEL alert for gas TWA alert for gas
Over limit alert for gas
*G7c devices only
Standard
Single
Multi (diffusion)
Multi (pump)
9 ||G7 TECHNICAL USER MANUAL
WHAT’S IN THE BOX
All devices G7 personal safety monitoring device Pre-installed cartridge
(Standard, Single-gas or multi-gas cartridge) Getting started guide Optional
real-time features guide · Charging system Removable charging clip · USB cable
· USB power adapter Certification and support card
Single-gas or Multi-gas cartridges If you have a single-gas or multi-gas
cartridge you will also receive:
Single-gas or multi-gas calibration cap (depending on your cartridge)
Calibration gas tubing
10 ||G7 TECHNICAL USER MANUAL
HARDWARE DETAILS
E
11 ||G7 TECHNICAL USER MANUAL
INTERACTION
HOW IT WORKS
Interacting with G7 is easy with its high-visibility LCD display and three-
button menu system.
OK button
Press OK to enter the main menu on the LCD screen and to confirm a menu
selection.
Up and down arrow buttons
Press up or down to navigate the menu. Press and hold both simultaneously to
mute a yellow warning alarm or red alert.
Latch pull
Pull down the latch to call for help when assistance is required.
Latch push button
Push the latch in to check in and tell your G7 that you are safe.
12 ||G7 TECHNICAL USER MANUAL
OPERATION
CHARGING
Insert the micro USB plug into the removable charging clip, then slide the
clip onto the charging port at the bottom of your G7.A solid red light at the
bottom of the device confirms your G7 is charging. The LCD screen will let you
know when it is fully charged, which can take up to four hours. Blackline
recommends that you fully charge your device after every shift.
NOTE: If you have G7 PowerPack accessory attached to your device, simply slide
the charging clip into PowerPack’s charging port. Both PowerPack and G7 will
be charged simultaneously.
WEARING
G7 monitor you best when clipped to your belt or chest pocket.
POWER ON
How do I power on G7c? Press and hold the power button and wait for the
blinking green connectivity light to turn solid. When connected, the green
light will remain solid.
13 ||G7 TECHNICAL USER MANUAL
How do I power on G7x? Press and hold the power button on your G7 Bridge to
turn it on first and wait for the blinking green connectivity light to turn
solid, it takes approximately two minutes for G7 Bridge to connect to the
Blackline Safety Network. When connected, the green light will remain solid.
Press and hold the power button on your G7x.Wait for the blinking green
connectivity light to turn solid. When connected, the green light will remain
solid. NOTE: For best results, ensure your G7 Bridge is turned on before your
G7x.If you are having difficulties connecting your G7x to G7 Bridge, please
refer to your G7 Bridge manual.
POWER OFF
How do I power off G7c? Press and hold the power button. The device will go
into shutdown sequence, once all the lights and vibrations have stopped, you
have been logged off from the Blackline Safety Network. How do I power off
G7x? Press and hold the power button of your G7x.The device will go into
shutdown sequence, sending your log off status to G7 Bridge. When suitably
powered, G7 Bridge can remain on at all times. When G7 Bridge is off, all
connected devices will no longer be monitored. Before powering down, ensure
there are no other G7x devices connected. Once confirmed, press and hold the
power button on the G7 Bridge. The device will go into shutdown sequence. Your
safety is no longer being monitored. NOTE: For more information, please refer
to the G7 Bridge technical user manual.
CONNECTIVITY LIGHT
Are you connected to the Blackline Safety Network? G7 lets you know your
connection status.
14 ||G7 TECHNICAL USER MANUAL
Blinking green light A blinking connectivity light indicates that your G7 is
storing data. It is not currently connected to the network and will send data
when the light is solid green. Solid green light A solid connectivity light
indicates that G7 is actively transmitting data and is connected to the
Blackline Safety Network. Sound and vibration Configurable to sound an alarm
if connection is lost after 5 minutes. NOTE: If you are using real-time
features, your safety is only monitored when the connectivity light is solid.
USING G7’S CONVENIENCE FEATURES
Much like a smartphone, G7 will include convenience features that will make it
easier for device users to do their jobs. If G7 is being used in an area where
cellphones are not permitted, these features will ensure users do not need to
carry multiple devices in the field — G7 can act as an all-in-one solution.
The timer and stopwatch features will be available from the both the main menu
and the quick-select menu. They will always be available on G7 devices using
firmware version 3.450 and higher — it will not be toggleable in the
configuration.
TIME
G7 now provides the option of showing the local time on the LED screen. The
time will be displayed in the top right of the main status screen. Since this
is also where the check-in timer is displayed, the user will have the option
to choose what information they would like to see if they also have the check-
in timer feature enabled.
How to show local time in the banner display The banner can display the check-
in timer or the local time. By default, if your G7 fleet is configured with
the check-in timer enabled, the screen will display the check-in timer to
ensure consistency with previous behavior.
15 ||G7 TECHNICAL USER MANUAL
To change the information displayed in G7’s main status screen banner: 1.
Press the OK button to open the main menu. 2. Use the up and down arrows to
navigate to Settings and press OK to select. Scroll to the “Banner” option.
You should see what the banner is currently set to. 3. To change the banner
display, click the OK button and confirm the change. If the banner was
previously set to “Check-in”, it should now be set to “Time” and vice versa.
4. The new state will be shown in-line with the Banner display option.
How to manually change the time By default, the local time feature will use
information gathered from nearby cell towers to determine the timezone and
current time based on location, similar to how a cell phone operates. However,
a cellular connection may be unavailable, or your physical location might be
on the border between timezones. In these cases, the default settings may
provide inconsistent timezone information. How to manually set a timezone
NOTE: Timezone offsets are relative to Greenwich Mean Time (GMT: 0:00). You
may need to look up the offset of your local timezone with respect to GMT —
remember to consider daylight savings as well if your region uses it.
1. Press OK to open the main menu. Use the up and down arrows to scroll down
to highlight the Time option and press OK to select.
2. Scroll down and select “Time settings”. 3. Select “Custom offset”. 4. On
the “Set time offset” screen, use the up and down arrows to scroll through
offset
options. Determine +/- (relative to GMT) first, then the number of offset
hours, and lastly the offset minutes if applicable 5. Once you have entered
the offset, press the OK button to confirm. Here, you can edit the offset if
needed, or cancel if you no longer want to set an offset.
16 ||G7 TECHNICAL USER MANUAL
Once you have input and confirmed the offset value you would like to use, go
back to the main status screen. The screen should now be displaying time based
on that custom offset value. If you would no longer like to use a manual
offset, select the “Auto” option from the Time settings menu and G7 will go
back to using cellular information to determine the local time. Displaying the
local time on G7x The local time feature on G7x requires a connection to a
bridge running 3.450 or later in order to use the “Auto” setting. If G7x has
not connected to a bridge since starting up, or if it is connected to a bridge
running earlier firmware, a blank time (- -:- -) will be displayed. Manually
enter the correct offset for your local timezone to display the local time on
the device.
TIMER
How to set the timer 1. Press the OK button to open the main menu, scroll down
to the “Time” option and press OK to select. 2. Select the “Timer” option. 3.
Select the unit of time (seconds or minutes), then the amount of time. 4.
Press OK to confirm your time, or select Edit to change your timer if you made
a mistake.
5. Once the timer is set, you will be able to see the remaining time in the
Time menu, inline with the “Timer” option.
6. You can stop the timer early by selecting the “Timer” option and pressing
the up button to clear the current timer.
17 ||G7 TECHNICAL USER MANUAL
How to stop the timer alarm When the timer counts down to 0, G7 will go into
an information alarm to inform the user to check the screen.
· Press and hold the up and down arrows for three beeps to silence the alarm
and clear the timer.
STOPWATCH
How to set the stopwatch 1. Press OK to open the main menu. 2. Scroll to Time
and press the OK button to select. 3. Select Stopwatch option. You will see a
screen with a stopwatch at 00:00:00. 4. To start the stopwatch, press the OK
button.
18 ||G7 TECHNICAL USER MANUAL
Where can I see how long the stopwatch has been running You can see how long
the stopwatch has been running by opening the Time menu. The stopwatch will be
displayed in-line with the “Stopwatch” option. Select the “Stopwatch” option
to open the screen. How to pause or reset the stopwatch
1. While on the “Stopwatch” screen, press the OK button to pause. Press OK
again to resume the stopwatch.
2. To reset the watch back to zero, press OK to stop the stopwatch, and then
the up arrow to reset.
19 ||G7 TECHNICAL USER MANUAL
VIEWING G7’S ASSIGNED USER
What is an assigned user? G7 can be assigned a team member in Blackline Live.
In the G7 configuration profile, there is also the option to display the
assigned user on the device, which allows you to identify which device belongs
to which user. G7 does not have to be assigned a user to function as gas
detector.
Where can I see G7’s assigned user? When the “display assigned user on device”
option is enabled from Blackline Live, G7 will show the assigned team member
in three places (as seen in the figures below):
On startup On the charging screen In G7’s menu, under Advanced info > User
info On the User info screen, you will also see a team member’s employee ID,
if it has been added in Blackline Live.
Startup
Charging screen
Advanced info > user info
20 ||G7 TECHNICAL USER MANUAL
GAS DETECTION
Included with your G7 Single-gas or Multi-gas cartridge is a calibration cap
and tubing for bump tests and calibrations. Alternatively, bump tests and
calibrations can be completed using G7 Dock. Only perform bump test and
calibrations in a safe environment. For more information and instructions on
bumping or calibrating with G7 Dock, refer to the G7 Dock technical user
manual.
BUMP TEST
What is a bump test? It is safe practice to regularly test gas sensors by
applying the target gas. G7’s bump test also tests the operation of light,
sound and vibration indicators. The bump test schedule depends on your
company’s safety policy.G7 automatically communicates bump test data to the
Blackline Safety Cloud, and will remind you when a bump test is overdue. The
bump test schedule is configurable. NOTE: To meet CSA LEL performance
standard, you are required to bump test before each day’s use. Blackline
recommends you do not exceed 30 days without a bump test.
How do I perform a bump test? 1. Attach tubing to the calibration cap. 2.
Ensure the other end of the tubing is attached to a fixed flow regulator on
the gas tank. 3. On your G7, press the OK button to enter the main menu. 4.
Use the arrow buttons to navigate to Gas options, press OK. 5. Use the arrow
buttons to navigate to Bump test, press OK. 6. Press the up arrow to continue.
7. G7 performs an automatic audio and visual assessment to test vibration and
lights. 8. You can individually choose which sensors to test. By default, G7
will test all sensors. 9. Attach the calibration cap to your device. 10. G7
will begin to count down from 60. Apply the gas within this time window. 11.
Turn gas off when prompted on your G7 screen. 12. Press the OK button to
complete bump test. 13. G7 will let you know if the bump test has passed or
failed, and when your next bump test is due.
21 ||G7 TECHNICAL USER MANUAL
14. Remove the calibration cap and let your G7 sit until the readings
stabilize and your G7 has returned to baseline.
NOTE: If you see a bump test fail message on your LCD screen, try the bump
test again. If the error persists, please contact our Customer Care team.
22 ||G7 TECHNICAL USER MANUAL
CALIBRATION
What is calibration? Gas sensors periodically need to be calibrated by
applying a known concentration of gas for a set amount of time. This procedure
ensures the gas sensor can accurately detect gas levels throughout its
operating life. The calibration schedule depends on your company’s safety
policy. Blackline recommends not exceeding 180 days without a calibration.
How do I perform a calibration? 1. Attach tubing to the calibration cap. 2.
Ensure the other end of the tubing is attached to a fixed flow regulator on
the gas tank. 3. On your G7, press the OK button to enter the main menu. 4.
Use the arrow buttons to navigate to Gas options, press OK. 5. Use the arrow
buttons to navigate to Calibration, press OK. 6. Press the up arrow to
continue. 7. G7 performs an automatic audio and visual assessment to test
vibration and lights. 8. You can individually choose which sensors to test.By
default, G7 will test all sensors. 9. Attach the calibration cap to your
device. 10. G7 will begin to count down from 60.Apply the gas within this time
window and continue to apply gas for 2 minutes. 11. Turn gas off when prompted
on your G7 screen. 12. Press the OK button to complete calibration. 13. G7
will let you know if the calibration has passed or failed, and when your next
calibration is due. 14. Remove the calibration cap and let your G7 sit until
the readings stabilize and your G7 is calibrated.
NOTE: If you see a calibration fail message on your LCD screen, try the
calibration again. If the error persists, please contact our Customer Care
team.
Calibration for special cases For gases that require special calibration
steps, see the support articles on the Blackline Support site:
How to calibrate O3 and ClO2 sensors
23 ||G7 TECHNICAL USER MANUAL
BUMP TEST AND CALIBRATION REMINDER WINDOW
What is the bump test and calibration reminder window? A bump test and
calibration reminder window can be customized from G7’s configuration profile
in Blackline Live. This setting will prompt the device to show a bump test or
calibration reminder alarm upon startup if one of these tests is due within
the configured window of time.
How does the bump test and calibration window work? Enabling this feature will
help ensure G7 goes into alarm upon startup instead of while it is in use in
the field. If you have a daily bump interval, your bump test will be due in 24
hours. However, if you start your shift 2 hours early the following day, you
will not be prompted to bump your device as 24 hours has not elapsed. When it
becomes due, you may already be out in the field without bump test materials.
If you have a 2-hour bump test/calibration reminder window, G7 will go into
yellow warning alarm for bump test due on startup when the bump is due within
this 2-hour window.
BUMP TEST AND CALIBRATION LOCK
What is the bump test and calibration lock? In the case that an organization
wants to make the device unusable when it is out of compliance, the
calibration or bump test lock can be enabled from G7’s configuration profile
in Blackline Live. This feature locks the device’s screen and all
functionality when a bump test or calibration is due on startup. This means
the user cannot use their device in any capacity (including gas readings, SOS
latch, message sending) until it has been bump tested or calibrated.
What if a bump test or calibration is due during my shift? If a bump test or
calibration becomes due during your shift (not on startup), the device will
not lock. This is a safety hazard, since the user will not be able to use G7
to call for help. The device will go into a yellow warning alarm for bump test
or calibration due, and the message will display in the banner, but the device
will remain fully functional. For more details, see the support article on the
Blackline Support site:
Bump test and calibration on G7
24 ||G7 TECHNICAL USER MANUAL
ZERO SENSORS
What is zeroing? If G7 is not reading zero and you know you are in an
atmosphere with no gas, your gas sensor readings may have shifted. If this
happens, it is best to calibrate your sensors. If you are unable to preform a
calibration, you can zero your sensors to reset the baseline. G7 can be
configured to automatically or manually zero on start-up when you turn on your
device from the configuration profile in Blackline Live. NOTE: The baseline
reading for oxygen is 20.9.
How do I zero sensors? 1. On your G7, press the OK button to open the main
menu 2. Press the arrow buttons to navigate to Gas options, press OK 3. Use
the arrow buttons to navigate to Zero sensors, press OK 4. Press the up arrow
to begin zeroing. Do not apply any gas. 5. The LCD screen will let you know
once zero is complete
NOTE: If you see a zero incomplete message on your LCD screen you may be in an
environment with gas levels, or your cartridge may need replacement.
PID TARGET GASES
What are target gases? Photoionization (PID) sensors can be used to detect a
large range of gases. A target gas refers to the specific gas you are using
trying to detect. G7’s readings will be adjusted based on the target gas it is
configured to detect.
How do I set G7’s target gas? G7’s PID sensor’s target gas is set from the
configuration profile in Blackline Live. Under the photoionization detector
section of the gas sensor settings card, you can choose an existing target gas
or set a custom target gas.
Where do I see which target gas G7 is detecting? The target gas G7 is
configured to use can be seen in two places:
On startup In the gas options menu, under gas info > VOC target
25 ||G7 TECHNICAL USER MANUAL
In both of these places, G7’s screen will display the target gas’ name, as
well as its correction factor.
GAS ALERT COUNTDOWN
This feature will make it easier to prevent false alarms from being delivered
to monitoring services. Gases like CO and O2 can spike and dip very quickly,
setting G7 into high gas alarm even when gas levels go back to normal. The gas
alert countdown is an optional gas feature that creates a time buffer before a
high gas alert is delivered to Blackline Live and to monitoring personnel.
How does the countdown work? Typically, when a device’s high gas threshold —
determined in the configuration profile — is crossed, the device will
immediately send an alert to Blackline Live. This is done so that monitoring
personnel can investigate the incident and follow up with the device user to
ensure their safety.
Since the alert is sent immediately, it can create false alarm scenarios where
monitoring personnel will be alerted even though the exposure was momentary
and the device user is back in a safe area. When the gas alert countdown
feature is enabled, the device will wait a configured amount of time before
sending the alert. G7 will still display red lights and an alert sound so that
the user knows to leave the immediate area. With the gas alert countdown
enabled, the banner at the top of the screen will show the remaining time
before an alert is sent to Blackline Live. If gas levels return to normal
before this time has elapsed, the alert will be cleared. The gas exposure will
still be visible in the device history view on Blackline Live but will not
appear as an alert in the Alerts list.
How do I set up the gas alert countdown feature? The gas alert countdown
feature will be turned off by default. To set up this feature:
1. Log into Blackline Live and go to the G7 configuration profile. In the gas
sensor settings section under each individual sensor, there will be two new
settings: a toggle labeled “Gas alert countdown” and a dropdown field labeled
“Gas alert timeout”.
26 ||G7 TECHNICAL USER MANUAL
2. Flip the toggle on for each sensor you want the countdown enabled for and
determine the length of buffer time from the “Gas alert timeout” dropdown.
After the configuration is saved and the devices successfully receive the new
settings, the gas alert countdown feature will be enabled. For instructions,
see the Blackline Support Centre website and search for Gas Alert Countdown.
USING G7 SENSORS IN COLD WEATHER
G7 is rated to operate down to -20°C (-4°F). G7 will function in temperatures
colder than this for short periods of time, but Blackline does not recommend
letting the device’s internal temperature drop below -20°C (-4°F). Electrolyte
sensors At temperatures below -20°C (-4°F), the sensor electrolyte inside CO,
H2S and other electrochemical sensors can freeze over time, reducing the
ability of the sensor to give a meaningful output. Storing G7 in a warm and
humid (60% relative humidity) environment when not in use will help keep
electrochemical sensors running longer. Shocking an electrochemical sensor
from room temperature to extreme cold and vice versa can also cause temporary
drifts in sensor readings. These readings typically resolve in less than 60
seconds.
Infrared (IR) LEL sensors Sudden temperature and humidity changes may cause
condensation within the LEL-IR sensor, which can affect its optics and trigger
a temporary baseline drift. Typically, they last less than 60 seconds, after
which point the readings will recover and G7 will function as normal. Shocking
the IR sensor from room temperature to an extremely cold environment can cause
a temporary baseline drift, typically less than 10% LEL. If this drift
persists, you can manually zero the sensor in the cold environment. Shocking
the IR sensor from an extremely cold environment to room temperature can cause
a temporary baseline drift, sometimes reaching overlimit. For more details,
see the Blackline Support Centre website and search for Operating G7 in cold
weather.
27 ||G7 TECHNICAL USER MANUAL
GAS ALARMS AND ALERTS
Once you have completed a bump test and calibration, G7 is ready to monitor
and notify you of gas exposure. Gas detection alarms will notify you with
either a yellow warning alarm or a red alert depending on the gas level
measured. All settings are customizable in Blackline Live. Speak to your
safety supervisor to learn about how your gas features are configured.
YELLOW WARNING ALARM GAS FEATURES
LOW WARNING ALARM FOR GAS
When does G7 trigger a low yellow warning alarm for gas? When gas levels reach
the low concentration threshold configured by your safety supervisor, G7 will
inform you with a yellow warning alarm. NOTE: A G7 with an O2 sensor will
trigger low warning alarms in both oxygen-deficient and oxygen-enriched
atmospheres. An oxygen-deficient atmosphere poses a risk of insufficient
oxygen for breathing. An oxygen-enriched atmosphere presents an increased risk
of explosion. Muting low warning alarms for gas You can choose to mute the
sound and vibration portion of an alarm, but the lights will stay active.
Persistent lights and recurring sound and vibration are there to encourage you
to leave, and help emergency responders to locate you in the event that you
pass out or are unable to remove yourself from the area. To mute the sound and
vibration portion of an alarm:
Press and hold the up and down arrows for three seconds and move to an area
where gas is not present
If you do not leave the area and gas levels remain above the low threshold,
the vibration and sound will restart in two minutes
28 ||G7 TECHNICAL USER MANUAL
SENSOR UNDER LIMIT
If a gas sensor’s baseline shifts, its reading will shift accordingly and
become unreliable. When this happens, the presence of gas can still be
measured, but cannot be converted into an accurate reading.G7 will inform you
of a sensor under limit with a yellow warning alarm. Your options to correct
reset the sensor’s baseline:
If you are in a clean atmosphere, you can zero your sensors to reset the
baseline You may need to perform a calibration to ensure the sensors are
accurately detecting
gas levels NOTE: Not all sensors can be zeroed, example: LEL sensor.
SENSOR ERROR
If a gas sensor stops working for any reason, G7 will inform you with a yellow
warning alarm. An X on your LCD screen will indicate which sensor or sensors
are generating the error message. Power off and restart your G7. If this does
not correct the problem, you will need to replace your cartridge.
PUMP BLOCK
If your pump inlet is blocked, G7 will inform you with a yellow warning alarm.
What do I do in the case of a yellow warning alarm?
Read your G7 screen. Press and hold the up and down arrow buttons at the same
time to let your G7 know you have read the message. Yellow warning alarms are
between you and G7, and will not notify any monitoring personnel if your
device is monitored.
29 ||G7 TECHNICAL USER MANUAL
RED ALERT GAS FEATURES
HIGH ALERT FOR GAS
When does G7 trigger a high alert for gas? If a gas sensor detects gas levels
above the high gas concentration threshold configured by your safety
supervisor. NOTE: A G7 with an O2 sensor will trigger red alerts in both
oxygen-deficient and oxygen-enriched situations. SHORT TERM EXPOSURE LIMIT
(STEL) ALERT An alert will be triggered when G7 detects you have reached the
STEL configured by your safety supervisor. STEL refers to the gas
concentration that you can be continuously exposed to for a configurable time
frame without suffering adverse health effects. TIME WEIGHTED AVERAGE (TWA)
ALERT An alert will be triggered if a toxic sensor detects you have exceeded
the average allowable amount of gas during a configured period of time,
informed by your TWA calculation method. NOTE: The two TWA measuring methods
available for use on your G7 are:
OSHA (United States Department of Labor Occupational Safety and Health
Administration) or
ACGIH (American Conference of Governmental Industrial Hygienists) OSHA is
defined as a rolling average of gas exposure accumulated over an eight-hour
period of operation. If the worker is in the field longer, the most recent
eight-hour cumulative value is used. ACGIH is defined as the total accumulated
average, from four to 16 hours as configured by your safety supervisor.
30 ||G7 TECHNICAL USER MANUAL
OVER LIMIT (OL) ALERT An alert is triggered when a gas sensor detects an
excessive amount of gas and can no longer give you an accurate reading. NOTE:
STEL, LEL and peak readings are reset on power cycle. To have G7 resume
readings instead, this setting can be configured in G7’s configuration profile
in Blackline Live.
What do I do in the case of a red alert?
Evacuate the area and follow your emergency safety protocol. Read the
information on your G7 screen. Press and hold the up and down arrow buttons at
the same time to mute the sound and vibration. If high gas levels are still
present, the sound and vibration will return after one minute. Sound and
vibration will return until gas levels and averages have reduced or returned
to acceptable concentrations. Red alerts are immediately communicated to any
monitoring personnel. Muting sound and vibration does not cancel the remote
alert sent to monitoring personnel.
31 ||G7 TECHNICAL USER MANUAL
CONFIGURATION MODES
Configuration modes are customized in the G7 configuration profile on
Blackline Live. Each profile supports up to a total of five modes. These modes
allow G7 to temporarily change its behavior for different situations, and can
be turned on and off through G7’s interface. Modes can be configured in the
portal so that they are only available when a pump cartridge is installed. To
enter a mode, you must complete a successful pump block test.
AVAILABLE MODES
Normal This mode is the configuration you determine for everyday operation. G7
will operate using this mode as a default.
Pre-entry Pre-entry mode is used before entering a space that could
potentially contain dangerous gas. This mode can be used with or without a
pump cartridge, which will actively draw surrounding air to its sensors and
test gas levels.
SCBA This mode is meant to be used when the device user is wearing a self-
contained or supplied air breathing apparatus (SCBA/SABA) and is entering an
area that is known to have high gas levels.
Leak check Leak check mode can be used when checking for gas leaks in a
particular area. This mode like pre-entry mode can be used with or without
a pump cartridge.
High risk This mode is unique in that it is meant for general high-risk
situations, such as an evacuation or travelling through a dangerous area.
Unlike the other modes, you will never be timed out and must exit it manually.
Pump run This mode is unique in that a multi-gas pump cartridge is required to
use this mode, and it runs the pump continuously such as for use in a hole-
watch situation. Unlike the other modes, you will never be timed out and must
exit it manually.
32 ||G7 TECHNICAL USER MANUAL
ENTERING A MODE
To use a mode, it must first be enabled in G7’s configuration profile on
Blackline Live. Enter a mode from G7’s main menu or main status screen.
How do I enter a mode from the modes menu? 1. Press OK to enter G7’s main
menu. 2. Use the up and down arrows to navigate to Modes. 3. Press OK to enter
the Modes menu. 4. Select the mode you wish to enter. 5. Confirm that you want
to enter the mode by selecting Yes. 6. G7’s screen will invert and your
information banner will display your current mode.
How do I enter a mode from the main status screen? 1. Press the up or down
arrow to open G7’s secondary menu. 2. Continue to press the up or down arrow
until you reach your desired mode. 3. Press OK to enter the mode. 4. G7’s
screen will invert and your information banner will display your current mode.
EXITING A MODE
How do I exit a mode? When you’d like to return the device to normal
operation, you will need to exit the configuration mode you are currently in.
Exiting a mode can be done from G7’s main menu or main status screen. To exit
from the modes menu:
1. Press OK to enter G7’s main menu. 2. Use the up and down arrows to
navigate to Modes. 3. Press OK to enter the modes Menu. 4. Select Normal mode.
5. Confirm that you want to return to normal mode by selecting Yes. 6. G7 will
return to normal function. To exit from the main status screen: 1. Press the
up or down arrow to open G7’s secondary menu
33 ||G7 TECHNICAL USER MANUAL
2. Press OK to exit the mode 3. G7 will return to normal function What is a
mode timeout? Each configuration mode for use in areas with potential gas
(pre-entry, SCBA and Leak check) has a timeout period. After this time period
has elapsed, you will be asked if you would like to continue in this mode. If
you select Yes, your mode will be extended. If you select No, G7 will return
to normal operation. If you do not make a selection within 30 seconds, G7 will
automatically return to normal operation. If you have a check-in timer
enabled, G7 will immediately ask you to check in.
34 ||G7 TECHNICAL USER MANUAL
CARTRIDGES
GAS CARTRIDGE REPLACEMENT PROGRAM
If you have an uninterrupted service plan for your G7 gas cartridge, Blackline
will replace expired cartridges for you free of charge. To inquire about or
request new cartridges, please contact our Customer Care team or your
distributor.
CHANGING CARTRIDGES
1. Power off G7. 2. Using a Phillips #1 screwdriver,
remove the screws on each side of the device. 3. Pull up on the cartridge. 4.
Slide a new cartridge onto G7, ensuring the cartridge clicks into place. 5.
Replace screws into each side of the device. NOTE: Cartridges should always be
replaced with a manual (not electric) screwdriver in order to avoid damage to
the device’s plastics.
CARTRIDGE CARE
Gas sensors are susceptible to contamination by a variety of common chemicals,
reducing or eliminating their sensitivity. Take care when using silicones,
cleaners, solvents and lubricants in close proximity to sensors as exposure
may cause permanent damage to the sensor. If a device is exposed to a new
chemical or compound, it is best practice to bump test and calibrate units to
ensure proper sensor function is maintained.
Changing filters for cartridges For instructions on how to change filters for
cartridges, visit support.blacklinesafety.com and see the following support
articles:
35 ||G7 TECHNICAL USER MANUAL
Replacing filters Replacing filter for G7 Multi-gas (diffusion) cartridge
LEL SENSOR PRECAUTIONS
For safety reasons this equipment must be operated and serviced by qualified
personnel only. Read and understand the instruction manual completely before
operating or servicing.
High off-scale readings may indicate an explosive concentration. Calibrations
must only be performed in areas free of flammable gases. Blackline supports
three different LEL sensor technologies:
Non-Dispersive Infra-Red (LEL-IR) This is recommended for use in inert
environments without oxygen. This sensor does not detect Hydrogen or
Acetylene.
Molecular Property Spectrometer (LEL-MPS) By default, the calibration process
will validate and ensure accuracy without adjusting the MPS sensor readings.
This sensor is factory calibrated for optimal accuracy and we recommend using
the factory calibration for the lifetime of the sensor. Advanced users can
perform a full calibration with a span adjustment by configuring this in
Blackline Live, but this may negatively impact the accuracy of other gases.
When bump testing or calibrating cartridges containing this sensor, Blackline
recommends applying a gas mixture containing at least 18% oxygen (O2).Less
oxygen than this may impact the MPS sensor’s reading. If a gas mixture with
less than 18% oxygen is applied to this sensor, power cycling the device is
recommended. Oxygen levels below 18% negatively impact accuracy. This sensor
is not intended for inert environments and Blackline does not recommend using
the sensor when oxygen levels are below 10%. The LEL-MPS sensor will auto-zero
at startup, and must be started in clean air.
Catalytic-bead pellistor (LEL-P) Any rapid up-scale reading followed by
declining or erratic reading may indicate a gas concentration beyond upper
scale limit which may be hazardous. Blackline does not offer this LEL sensor
anymore.
36 ||G7 TECHNICAL USER MANUAL
Blackline’s LEL sensors can be calibrated with the following settings:
Gas Methane (CH4)
Calibration concentration (%vol)
2.5%
Calibration concentration (%LEL)
50%±2%
Balance (±5% tolerance)
O2 18% CO 100ppm H2S 25ppm N2 Balance
No known gases desensitize or contaminate Blackline’s LEL sensors. Blackline’s LEL sensors do not cause any EMI interference, and are not negatively affected by EMI of up to 8W.
LEL LATCHING ALARM
Enabling the LEL latching alarm setting means G7 will not stop alarming when
LEL sensor readings return from the high alarm threshold. The device user must
manually cancel the alarm by pressing and holding on the G7’s up and down
arrow buttons for three seconds. If the LEL gas alarm is not canceled by the
device user, it will continue until the battery is depleted.
How do I enable the LEL latching alarm? 1. From the gas status screen, press
OK twice to enter the Main menu 2. Use the up and down arrow buttons to
navigate to Gas info 3. Press OK to enter the Gas info menu 4. Select Gas
options 5. Select LEL latching from the list and confirm your selection
The setting you have chosen for LEL latching alarm will remain in place until
it is changed manually. It will not be affected by power cycling the device or
downloading future firmware updates.
37 ||G7 TECHNICAL USER MANUAL
MULTI-GAS PUMP CARTRIDGE
Using Pump
How do I turn pump on? 1. Ensure G7 is equipped with a multi-pump cartridge
and
pumped modes, such as pre-entry, leak check or pump run 2. From G7’s main or
secondary menu, select the pumped mode you wish to enter 3. Attach tubing, and
perform a block test by following the instructions on G7’s screen 4. G7’s
screen will invert, and the pump icon will show in the info bar to let you
know pump is running
How do I turn pump off? To turn pump off, enter any non-pumped mode, such as
normal, SCBA or high risk mode.
Where do I see my pump details? When a pump cartridge is attached to G7, you
can see the pump status screen by pressing the up or down arrow from G7’s main
screen. Here you can see if pump is on or off, your hose length, flow rate and
sample time (if enabled).
How do I bump test or calibrate my pumped cartridge? Manually bump testing and
calibrating pump cartridges is done using the same calibration cap and method
as G7’s multi-gas cartridge. Please see “How do I bump test?” on page 23 for
stepby-step instructions. G7 cannot be bump tested or calibrated through the
pump itself. Bump testing and calibrating with a G7 Dock requires an updated
G7 Dock unit. You can tell if your Dock is an updated unit by checking that
its unit ID is Dock-P.
How do I perform a block test? You will be asked to perform a block test upon
entering any pumped mode, such as leak check, pre-entry or pump run. Follow
the steps on G7’s screen to complete the block test. If you do not pass the
block test, you will not be able to enter the mode. IMPORTANT: When performing
an automatic block test, G7 is in a safe mode where gas alerts will not be
triggered. This prevents triggering false alerts from residual gas in the
tubing.
38 ||G7 TECHNICAL USER MANUAL
When you are in a pumped mode, you can perform a manual block test at any time
by plugging G7’s inlet. This will cause G7 to go into yellow warning alarm,
and your screen will let you know that your pump is blocked. Unplug your
inlet, and if the warning alarm silences, you know that your equipment is safe
to use. What is flow rate? Flow rate is the speed at which air is passing over
your device’s sensors. In order to provide accurate gas readings, flow rate
needs to be above 150 ml/min. A flow rate less than 150 ml/min will result in
a pump block yellow warning alarm. By default, Blackline’s pump aims to
maintain a flow rate of 300ml/min and G7 will automatically adjust its pump
speed to maintain this rate.
39 ||G7 TECHNICAL USER MANUAL
PUMP OPTIONS
Settings for pump can be found in G7’s main menu, under Settings > Pump
options.
What is the sample timer? The sample timer is the amount of time it takes for
one air sample to be pumped to your sensors. This calculation is based on your
hose length. If sample timer is enabled, the pump status screen will show a
countdown and beep once when a sample cycle has completed. The sample cycle
will repeat continuously until you turn pump off. If disabled, the sample
timer will not show and the device will not beep, and pump will continue to
function normally. Blackline recommends a 120 second sample time for 10 feet
of tubing, with an additional second per foot of tubing.
How do I enable or disable the sample timer? 1. Press OK to enter G7’s main
menu. 2. Use the up and down arrows to navigate to Settings, press OK. 3. Use
the up and down arrows to navigate to Pump options, press OK. 4. The menu will
display the current status of your sample timer. Select Sample timer off or
Sample timer on. 5. Select Yes to confirm that you would like to enable or
disable the sample timer
What is hose length? Hose length is an estimate of how long the tubing
attached to pump is. This value is customizable from the pump options menu,
and factors in to sample time.G7’s multi-gas pump cartridge supports a maximum
of 99 feet of tubing.
How do I change hose length? 1. Press OK to enter G7’s main menu. 2. Use the
up and down arrows to navigate to Settings and press OK. 3. Use the up and
down arrows to navigate to Pump options and press OK. 4. Select hose length.
5. Use the up and down arrows to choose your units, meters or feet, and press
OK. 6. Use the up and down arrow to enter the first digit of your length and
press OK. 7. Use the up and down arrow to enter the second digit of your
length and press OK. 8. Select Yes to confirm your length or select Edit to
make changes to your choice.
40 ||G7 TECHNICAL USER MANUAL
REAL-TIME FEATURES
Your G7 can be equipped with many features to monitor your safety. They are
categorized into the type of notifications they trigger — lower urgency
events, yellow pending alarms, yellow warning alarms, and red alerts. All are
customizable in Blackline Live to best fit your needs. Speak to your safety
supervisor to learn about how G7 features are configured.
LOWER URGENCY ALARMS
The information alarm is used to communicate lower urgency events. The
information alarm includes yellow flashing lights, the information sound,
vibration and an on-screen message specific to each event. The alarm repeats
itself on a loop until it is acknowledged by pressing and holding the up and
down arrows for three beeps.
Low Battery If your battery level goes below a configurable level (example:
20%), G7 will go into an information alarm and display a message on the LCD
screen. Connection Lost If your device loses connection with the Blackline
Safety Network, the green light at the top of the device will blink and G7
will go into an information alarm after a configurable amount of time
(example: five minutes).
Bump Test Reminder When gas sensors are due for a bump test, G7 will go into
an information alarm and display a message on the LCD screen. The bump test
schedule depends on your company’s safety policy. For bump test instructions,
see How do I perform a bump test?
41 ||G7 TECHNICAL USER MANUAL
Calibration Reminder When gas sensors are due for a calibration, G7 will go
into an information alarm and display a message on the LCD screen. The
calibration schedule depends on your company’s safety policy. For calibration
instructions, see How do I perform a calibration? Timer If the timer counts
down to 0, G7 will go into an information alarm to inform the user to check
the screen. Press and hold the up and down arrows for three beeps will silence
the alarm and clear the timer. Pairing Needed (G7x) When G7x doesn’t have a
network key (which is required to connect to G7 Bridge), the device will go
into an information alarm and display “Pairing needed” on the LCD screen. To
resolve:
1. From Bridge, select Menu > Pairing needed > Start. 2. Bridge will scan for
nearby keyless devices for approximately 3 minutes and send its key
to any found devices. If this does not resolve the issue, contact Customer
Care.
What do I do in the case of an information alarm?
1. Read your G7 screen. 2. Press and hold the up and down arrow
buttons at the same time to let G7 know you have read the message. Information
alarms are between you and G7 and will not notify monitoring personnel if your
device is monitored.
42 ||G7 TECHNICAL USER MANUAL
YELLOW WARNING ALARM FEATURES
The yellow warning alarm is used to communicate events that require your
attention. The yellow warning alarm includes yellow flashing lights, the
warning alarm sound, vibration and an on-screen message specific to each
event. The alarm repeats itself on a loop until it is acknowledged by pressing
and holding the up and down arrows.
Messages Where do I see messages? Your device can receive messages from
monitoring personnel via Blackline Live. When there is an incoming message, G7
will inform you with a yellow warning alarm. How do I send a message? You can
choose from a list of 10 pre-programmed messages to send to monitoring
personnel. The messages are customizable from Blackline Live. 1. Press the OK
button to enter the main menu. 2. Press the up or down arrow buttons to
navigate the menu and
highlight your selected message. 3. Press the OK button to send. How do I send
a custom message? At the bottom of the pre-programmed message list is an
option to send a 16-character custom message to monitoring personnel. Press
the up or down arrow buttons to scroll through the alphabet and numbers, press
the OK button to move to the next character, press the OK button again to
send. NOTE: In the confirmation screen of your custom message, you have the
ability to edit the current message by pressing the up arrow button, send
43 ||G7 TECHNICAL USER MANUAL
the message by pressing the OK button or cancel the message by pressing the
down arrow button.
Two-way Voice Calling
How do I use two-way voice calling? If you have a G7c with a voice-enabled
service plan, your speakerphone will automatically answer a call from
monitoring personnel. G7 will inform you of an incoming call with a yellow
warning alarm and you will hear a beep signifying the two-way voice call has
been connected. In a noisy environment, it may be necessary to remove and hold
the device near your ear, as you would a two-way radio.
What do I do in case of a yellow warning alarm?
1. Read your G7 screen.
2. Press and hold the up and down arrow buttons at the same time to let G7
know you have read the message.
Yellow warning alarms are between you and G7 and will not notify monitoring
personnel if your device is monitored.
44 ||G7 TECHNICAL USER MANUAL
YELLOW PENDING ALARM FEATURES
The yellow pending alarm is used to check that you are safe. The yellow
pending alarm includes yellow flashing lights, the pending alarm sound,
vibration and an on-screen message specific to each event. The alarm repeats
itself on a loop until it is acknowledged by pressing and holding the up and
down arrows for three beeps.
Potential Fall Detected If enabled, G7 will be constantly monitoring your
movement for falls. If a potential fall is detected, G7 will initiate a yellow
pending alarm. The fall detection sensitivity is configurable.
Potential No-Motion Detected If enabled, G7 will be constantly monitoring your
motion. It will automatically detect if you do not move within a pre-set
duration and will initiate a yellow pending alarm. The no-motion period and
sensitivity are configurable.
Check-In Request If enabled, you can configure your device to request periodic
check-ins throughout your shift. The check-in countdown is displayed at the
top right of the LCD screen. At the end of the timer, your G7 will initiate a
yellow pending alarm to confirm you are safe. The check-in timer and pending
alarm time are configurable. NOTE: Your device can be configured to check-in
early, before the yellow pending alarm sounds. If enabled, you can push and
hold the red latch button for the duration of three vibrations to reset your
check-in timer before the audible alarm. An early check-in cannot be
configured if Silent SOS alert is enabled.
45 ||G7 TECHNICAL USER MANUAL
What do I do in the case of a yellow pending alarm?
If you are safe, push the red latch button. If you do not push the latch
within the configured amount of time, your yellow pending alarm will
communicate a red alert to monitoring personnel.
NOTE: G7 can be configured to mute pending alarms while driving at speeds
above 35 km/hr (22 mph) or while charging.
RED ALERT FEATURES
Fall Detected If your device detects a fall and you have not responded to the
yellow pending alarm, G7 will communicate a red alert to monitoring personnel.
The fall detection sensitivity is configurable.
No-Motion Detected If you are not moving and you have not responded to the
yellow pending alarm, G7 will communicate a red alert to monitoring personnel.
The nomotion period and sensitivity are configurable.
46 ||G7 TECHNICAL USER MANUAL
Missed Check-In If enabled and you are unable to check-in during the yellow
pending alarm time, your device will communicate a red alert to monitoring
personnel.
SOS Alert If you require assistance, you can manually send an SOS alert to
monitoring personnel and request immediate help to your location by pulling
the red latch. NOTE: Your device can be configured to send a Silent SOS alert
to monitoring personnel without light, sound and vibration.
What do I do in the case of a red alert?
Red alerts are immediately communicated to monitoring personnel.
1. Read the information on your G7 screen.
2. Press and hold the up and down arrow buttons at the same time to mute the
sound and vibration.
This does not cancel the red alert sent to monitoring personnel.
47 ||G7 TECHNICAL USER MANUAL
LIVERESPONSE LIGHT
When monitoring personnel have acknowledged your red alert, the blue
LiveResponse light will shine on your device.
This light lets you know that remote monitoring personnel are responding by
following your team’s emergency protocol. Once monitoring personnel have
resolved the red alert, the blue LiveResponse light will shut off. Depending
on your response protocol, a G7c with voice enabled service plan will
automatically connect your speaker phone to monitoring personnel. In the case
that a silent SOS alert is sent, the blue LiveResponse light will not shine.
Instead, G7 can be configured to vibrate to let you know that remote
monitoring personnel are responding by following your team’s emergency
protocol.
PUSH-TO-TALK (PTT)
If you have a G7c with a PTT service plan and PTT is enabled in your device’s
configuration profile, push-to-talk allows you to send and receive voice
messages to other G7c device users, similar to a walkie-talkie. Push-to-talk
is only available on G7c devices.
TRANSMITTING
How do I send a PTT message? 1. Press and hold the red latch. 2. When G7c
finishes beeping, continue to hold and begin talking with the device about 6
inches from your mouth. NOTE: If you are using an O2 sensor, be sure that you
are talking into G7’s microphone, not the cartridge, as this could cause gas
alarms. 3. When you’re finished talking, release the latch. G7 allows PTT
messages up to 30 seconds in length. 4. G7c will beep once more to let you
know it’s done listening.
48 ||G7 TECHNICAL USER MANUAL
RECEIVING
How do I receive a PTT message? 1. G7c will beep twice to signal an incoming
PTT message. 2. G7c will play the message. 3. 3. G7c will beep once more when
the message is done.
NOTE: G7c’s screen will display which channel you are transmitting to or
receiving from.
AVAILABLE CHANNELS
Channel 0-99 Channels 0 through 99 are available for everyday use.When on a
specific channel, you will only be able to communicate with devices that are
on the same channel, and will receive transmissions from all call.
All call All call is a channel where G7c will transmit to all PTT devices in
your organization, and will only hear transmissions from all call.This channel
is recommended for safety supervisors or managers.
Receive only The receive only channel only hears transmissions from all call,
and can’t transmit to other devices.
CHANGING CHANNELS
Go to the PTT channel menu to change your PTT channel.
To change to a specific channel number: 1. Press the OK button to enter G7c’s
main menu. 2. Use the up and down arrows to navigate to PTT channels and
select OK. 3. Select Enter channel #. 4. Use the up and down arrows to enter
the first digit of your channel. For example, for
channel 40, the first digit is 4. 5. Press OK. 6. Use the up and down arrow to
enter the second digit of your channel. For example, for
channel 40, the second digit is 0.
49 ||G7 TECHNICAL USER MANUAL
7. Press OK. 8. Select Yes to confirm and change G7c’s channel or select Edit
to make changes.
To change to receive only or all call: 1. Press the OK button to enter G7c’s
main menu. 2. Use the up and down arrows to navigate to PTT channels and
select OK. 3. Select Receive only or All call. 4. Read the message on the
screen. 5. Select Yes to confirm. NOTE: You can also navigate to the PTT
channels menu by pressing the up or down arrow from the main screen, and
pressing OK when the current PTT channel shows.
CHANGING VOLUME
Changing the volume of incoming calls can be done from G7’s main screen or the
PTT channel menu. Changing your PTT volume only affects incoming calls, and
won’t change the way G7’s alerts sound.
To change volume from the main screen: 1. Press and hold the up or down arrow.
2. Use the up and down arrows to set G7’s volume to the desired level. 3.
Press OK or wait for the screen to timeout to save.
To change volume from the PTT channel menu: 1. Press the OK button to enter
G7c’s main menu. 2. Use the up and down arrows to navigate to PTT channels and
select OK. 3. Use the up and down arrows to navigate to Change volume and
select OK. 4. Use the up and down arrows to set G7’s volume to the desired
level. 5. Press OK or wait for the screen to timeout to save.
PTT AUDIO ACCESSORIES
G7c is equipped with audio pairing in order to use an audio accessory with
push-to-talk. All settings for audio devices can be found in G7’s main menu,
under Settings > Audio pairing.
50 ||G7 TECHNICAL USER MANUAL
How do I pair a new audio device? 1. Press OK to enter the main menu. 2. Use
the up and down arrows to navigate to Accessories. 3. Navigate to Audio
pairing and press OK. 4. Use the up and down arrows to navigate to Pair new
and press OK. 5. Put your audio accessory into pairing mode as per its
instructions. 6. Select your audio accessory from the list. 7. G7 will give
you a successful connection message when your device is connected, and you
will see an audio accessory icon in the info bar of G7c’s main screen. How do
I reconnect to an audio device? G7 will remember your audio accessory and pair
automatically when both are powered on.In the case that it doesn’t, you can
reconnect to your accessory from the audio pairing menu. 1. Press OK to enter
the Main menu. 2. Use the up and down arrows to navigate to Settings. 3.
Navigate to Audio pairing and press OK. 4. Use the up and down arrows to
navigate to Reconnect and press OK. 5. Ensure your accessory is on. 6. G7c
will reconnect to your audio accessory, and you will see an audio accessory
icon in the
info bar of G7c’s main screen when the connection is successful. How do I
forget a paired device? 1. Press OK to enter the Main menu. 2. Use the up and
down arrows to navigate to Settings. 3. Navigate to Audio pairing and press
OK. 4. Use the up and down arrows to navigate to Forget device and press OK.
5. Select Yes to confirm that you would like to forget your accessory. NOTE:
Audio accessories can only be used for push-to-talk purposes, and cannot be
used for early check-ins or confirming pending alarms.
51 ||G7 TECHNICAL USER MANUAL
OVER-THE-AIR (OTA) FIRMWARE UPDATES
To offer new features, Blackline Safety periodically releases over-the-air
(OTA) firmware updates. OTA firmware updates are only available when G7 is on
a cellular network. Firmware updates have two steps:
Automatic download
Automatic installation
Automatic download
When a firmware update is released, G7 will gradually download the update
whenever it is on and connected to a cellular network. G7 will be ready to
install the firmware update when the download is complete. This will not
interfere with normal G7 use.
Automatic installation
The completely downloaded update will automatically be installed the next time
G7 is powered on. This installation will add 30-60 seconds to the startup
sequence.
When the green light is solid and G7 is connected, it will automatically power
down. The user will then see flashing blue and yellow lights on the right side
of the LED screen and the device will be unresponsive. After 30-60 seconds, G7
will power back up and display the new firmware version it has downloaded.
Once completed, G7 will continue to monitor as usual.
SAFETY WARNING: G7 will NOT monitor during the installation process.
Specific information about new updates can be found at Support
BlacklineSafety.com. If you have any questions, please contact our Customer
Care team.
Firmware Update Kits
OTA firmware updates are only available for G7 Bridge when it is brought into
cellular range. If G7 Bridge cannot be removed from satellite-only reception,
contact Customer Care to receive a firmware update kit.
52 ||G7 TECHNICAL USER MANUAL
SUPPORT
LEARN MORE
Visit support.BlacklineSafety.com to find support and training materials for
G7.
CUSTOMER CARE
For technical support, contact our Customer Care team. North America (24
hours) Toll Free: 1-877-869-7212 |
support@blacklinesafety.com United Kingdom (8am-5pm GMT) +44 1787 222684 |
eusupport@blacklinesafety.com International (24 hours)
+1-403-451-0327 |
support@blacklinesafety.com
53 ||G7 TECHNICAL USER MANUAL
SPECIFICATIONS
DETAILED SPECIFICATIONS
Standard G7 safety features
Fall detection and No-motion detection: Tri-axis accelerometer, tri-axis gyro,
software processing, configurable sensitivity, configurable time for
nomotionSOS latch: Pull latch to trigger SOS alert Silent SOS: Press and hold
latch to trigger SOS alert Low-battery: Configurable threshold Worker check-
in: Configurable timer (30 180 min, oroff ), automatic check-in when driving
Additional gas cartridge features
Under limitOver limit Time-weighted average (TWA) Short-term exposure limit
(STEL)High gas alert Low gas alert Bump test and calibration notificationBump
test and calibration failure
Size & weight
G7 with Standard Cartridge Size: 64 mm x 124 mm x 27 mm (2.52″ x 4.88″ x
1.06″) Weight: 162 g (5.7 oz)
G7 with Single-gas Cartridge Size: 64 mm x 128 mm x 27 mm (2.52″ x 5.04″ x
1.06″) Weight: 167 g (5.9 oz)
G7 with Quad-gas Cartridge Size: 66 mm x 150 mm x 27 mm (2.52″ x 5.91″ x
1.06″) Weight: 192 g (6.8 oz)
G7 with Multi-gas pump Cartridge Size: 66 mm x 151 mm x 38.5 mm (2.6″ x 5.95″
x 1.52″) Weight: 238 g (8.4 oz)” Target flow rate: 300ml/min Maximum hose
length: 99ft (30.2 m)
User interface
168 by 144 pixel graphical, high contrast, liquid crystal display with front
lighting, menu system driven by three-button keypad, power button (on/off ),
check-in button (check-in/silent SOS), SOS latch (send SOS alert) Multi-
language support: Yes, EN, FR, ES, NL, DE, IT, PT”
User notification
Green SureSafe® light: Blinking (powered),continuous (connected) Yellow top
and front lights: Yellow pending alarm andyellow warning alarm Red top and
front lights: Red alert communicated Blue LiveResponseTM top and front lights:
Confirmation that a monitoring team has acknowledged the alert Alarm
Indicators: Speaker, LED lights and vibration motorSpeaker sound pressure
level: ~95 dB @ 30 cm (~95 dB @ 11.8″) Voice calling: Speakerphone and phone
modes (G7cmodel only)
G7c wireless radio
Wireless coverage: 100 countries, 200 wireless carriers North America: 3G/4G
radio, 3G UMTS bands 2 and 5; 4G bands 2, 4 and 5 International: 2G/4G radio,
2G G ESM bands E-GSM and PCS; 4G bands 3, 7 and 20 Asia Pacific: 3G/4G radio;
3G UMTS band 1; 4G bands 3, 8 and 28 Antenna: Internal regionally optimised
G7x wireless radio
Works with G7 bridge satellite base station Radio: 902.0928.0 MHz, 1 Watt
Antenna: Internal Radio link range: 2 km (1.25 mi) real-world
Wireless updates
Device configuration changes: Yes, Device firmware upgrade over-the-air
(FOTA): Yes
Location technology
GPS Radio: 48-channel high sensitivity Assisted-GPS: Yes (G7c model only) GPS
Accuracy: ~5 m (16 ft) Outdoors Indoor location technology: Blackline Safety
location beacons Location update frequency: G7c 5 min, G7x 15 min defaults
Power & battery
Rechargeable Li-ion battery: 1100 mAh Li-ion Battery Life: 18 hours at 20°C
(68°F) under normal usage Charge time: 4 hours
Environmental
Storage temperature: -30°C to 60°C (-22°F to 140°F) Operating temperature:
-20°C to 55°C (-4°F to 131°F)Charging temperature: 0°C to 45°C (32°F to 113°F)
Ingress Protection: Designed to meet IP67
Approvals
G7c: SAR, RoHS, CE, RCM Unit ID 3570xxxxxx FCC ID: W77G7C2 IC: 8255A-G7C2
Contains FCC ID: XPY1EIQ24NN IC: 8595A-1EIQ24NN or Unit ID 3567xxxxxx FCC ID:
W77G7C IC: 8255A-G7C Contains FCC ID: XPY1CGM5NNN, IC: 8595A-1CGM5NNN or Unit
ID 3566xxxxxx Contains FCC ID: XPY1CGM5NNN, IC: 8595A-1CGM5NNN Canada & USA:
Class I Division 1 Group A,B,C,D T4;Class I Zone 0 AEx da ia IIC T4; Ex da ia
IIC T4 Ga IECEx: Ex da ia IIC T4 Ga ATEX:Ex da ia IIC T4 Ga LEL: CSA C22.2
No.152; ISA 12.13.01 LEL Pump Cartridge: CSA C22.2 No.152; 0°C Ta 40°C;
ANSI/ISA12.13.01; -10°C Ta 40°C G7x: SAR, RoHS, RCM FCC ID: W77G7X | IC ID:
8255A-G7X Canada & USA: Class I Division 1 Group A,B,C,D T4;Class I Zone 0 AEx
da ia IIC T4; Ex da ia IIC T4 Ga IECEx: Ex ib IIC T4 Gb LEL: CSA C22.2 No.152;
ISA 12.13.01 LEL Pump Cartridge: CSA C22.2 No.152; 0°C Ta 40°C;
ANSI/ISA12.13.01; -10°C Ta 40°C
Warranty
G7: two years limited warranty Cartridges: lifetime with service plan
Blackline Complete: three year operating lease withthree year warranty
Blackline Live web application
Cloud-hosted safety monitoring web application is highly customizable for
every customer requirement.Includes live map, employee address book, user
roles,alert management, device configurations, alert setups and reporting
54 ||G7 TECHNICAL USER MANUAL
Gas sensor specifications
Gas
Sensor type
Ammonia (NH3)
Electrochemical
High-range ammonia (NH3)
Electrochemical
Carbon monoxide (CO)
Electrochemical
High-range carbon monoxide (CO)
Electrochemical
Hydrogen resistant carbon monoxide (CO-H) Electrochemical
Carbon dioxide (CO2)
NDIR
Chlorine (Cl2)
Electrochemical
Chlorine dioxide (ClO2)
Electrochemical
COSH
Electrochemical
Hydrogen (H2) Hydrogen cyanide (HCN) Hydrogen sulphide (H2S) High-range
hydrogen sulphide (H2S) LEL-infrared (LEL-IR) Oxygen (O2)
Ozone (O3) Photoionisation (PID)
Electrochemical Electrochemical Electrochemical
Electrochemical NDIR Pumped electrochemical Electrochemical PID
Sulphur dioxide (SO2)
Electrochemical
Range
0100 ppm 0500 ppm 0500 ppm 02000 ppm 0500 ppm 050,000 ppm 020 ppm 0-2
ppm 0500 ppm CO, 0100 ppm H2S 040,000 ppm 030 ppm 0100 ppm 0-500 ppm
0100% LEL 025% vol
Resolution
0.1 ppm 1 ppm 1 ppm 5 ppm 1 ppm 50 ppm 0.1 ppm 0.01 ppm 1 ppm CO, 0.1 ppm H2S
1% LEL (400 ppm) 0.1 ppm 0.1 ppm 0.5 ppm 1% LEL 0.1% vol
0-1 ppm 06,000 ppm
0100 ppm
0.01 ppm 0.1 ppm (0100 ppm), 2 ppm (1006,000 ppm) 0.1 ppm
55 ||G7 TECHNICAL USER MANUAL
LEGAL NOTICES AND CERTIFICATIONS
LEGAL NOTICES
Information in this document is subject to change without notice. This
document is provided “as is” and Blackline Safety Corp. (“Blackline”) and its
affiliated companies and partners assume no responsibility for any
typographical, technical or other inaccuracies in this document. Blackline
reserves the right to periodically change information that is contained in
this document. However, Blackline makes no commitment to provide any such
changes, updates, enhancements or other additions to this document to you in a
timely manner or at all.
Copyright © 2016 Blackline Safety Corp. All rights reserved.
Except as expressly provided herein, no part of this manual may be reproduced,
copied, transmitted, disseminated, downloaded, or stored in any storage
medium, for any purpose without the express prior written consent of Blackline
Safety Corp (“Blackline” ). Blackline hereby grants permission to download a
single copy of this manual onto some form of electronic storage medium to be
viewed and to print one copy of this manual or any revision hereto, provided
that such electronic or printed copy of this manual must contain the complete
text of this copyright notice. Further, any unauthorized commercial
distribution of this manual or any revision hereto is strictly prohibited.
The Blackline, Alert, Locate, Respond, families of related marks, images and
symbols, including Blackline, G7, G7c, G7x, LiveResponse, Loner, Loner IS,
Loner IS+, Loner M6, Loner M6i, Loner Mobile, Loner 900, and SureSafe are the
exclusive properties and trademarks of Blackline Safety Corp. All other
brands, product names, company names, trademarks and service marks are the
properties of their respective owners.
Warranty
Your G7 device is warranted against defects in materials and workmanship for
up to two years from date of purchase. For further details regarding your
Blackline warranty, please refer to your terms and conditions of service.
FCC Compliance
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC rules.These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
· Reorient or relocate the receiving antenna.
· Increase the separation between the equipment and receiver.
· Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
· Consult the dealer or an experienced radio/TV technician for further
assistance.
Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Note: the grantee is not responsible for any changes or modifications not
expressly approved by the party responsible for compliance. Such modifications
could void the user’s authority to operate the equipment.
RF exposure was tested with the supplied belt clip. Use of third-party
accessories may result in non-compliant exposure.
56 ||G7 TECHNICAL USER MANUAL
Industry Canada Compliance This device complies with Industry Canada licence-
exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept
any interference, including interference that may cause undesired operation of
the device. RF exposure was tested with the supplied belt clip. Use of third-
party accessories may result in non-compliant exposure. Notification
d’Industrie Canada Ce dispositif est conforme au(x) format(s) RSS libre(s)
d’Industrie Canada. Son fonctionnement est assujetti aux deux conditions
suivantes : (1) Cet appareil ne peut causer d’interférences nuisibles, et (2)
cet appareil doit accepter toute interférence reçue, y compris les
interférences pouvant provoquer un mauvais fonctionnement du dispositive.
L’exposition RF a été testée avec le clip de ceinture fourni. L’utilisation
d’accessoires tiers peut entraîner une exposition non conforme. Warning Do not
operate Blackline Safety products where you are not able to safely operate
your mobile/cellular phone. Electrical equipment may be hazardous if misused.
Operation of this product, or similar products, must always be supervised by
an adult. Do not allow children access to the interior of any electrical
product and do not permit them to handle any cables. Do not operate or store
Blackline products outside their specified operating or storage temperatures.
Consult the specifications section for more information. Blackline products
contain a non-replaceable internal lithium-ion battery pack. Seek advice from
your local electronics recycling authority regarding the disposal of your
device. Do not dispose Blackline products in your household trash.
57 ||G7 TECHNICAL USER MANUAL
INTRINSICALLY SAFE CERTIFICATION