MINCO Increased Safety Thermal-RibbonTM RTDs Instructions
- June 10, 2024
- MINCO
Table of Contents
- MINCO Increased Safety Thermal-RibbonTM RTDs Instructions
- Instructions: Increased Safety Thermal-Ribbon™ RTDs
- 1.Description
- 2.Attestation of Conformity
- 3. Installation Instructions
- 4. Special Conditions of Use
- 5. .Electrical Data
- 6. Electrical Connections
- 7. Marking Example
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MINCO Increased Safety Thermal-RibbonTM RTDs Instructions
Instructions: Increased Safety Thermal-Ribbon™ RTDs
II 2 G Ex eb IIC Gb
IECEx Ex eb IIC Gb
SPI 00-0491 Rev. D (Document 1889233)
1.Description
The Thermal-Ribbon™ Resistance Temperature Detectors (RTDs), conforming to the requirements of Minco Design Definition B212716, are intended to be built into the stator slots of rotating electrical machines, or installed within protective locations or enclosures in other equipment, in types of protection Ex eb II, Ex p II or Ex db IIC. Versions for 2-, 3- or 4-wire measurement circuits are available. Operating temperature range: -50°C to +185°C.
2.Attestation of Conformity
This Attestation of Conformity is issued under the sole responsibility of the manufacturer. Thermal-RibbonTM RTD Type: B212716.
The product defined above is in conformity with the following relevant
legislation: ATEX Directive 2014/34/EU
EN IEC 60079-0:2018 Explosive atmospheres – Part 0: Equipment – General
requirements
EN IEC 60079-7:2015+A1:2018 Explosive atmospheres – Part 7: Equipment
protection by increased safety “e” IEC 60079-0:2017-12 Ed7.0 Explosive
atmospheres – Part 0: Equipment – General requirements
IEC 60079-7:2017-08 Ed5.1 Explosive atmospheres – Part 7: Equipment protection
by increased safety “e”
Certificate LCIE 13 ATEX 3022 U Certificate IECEx LCIE 13.0019 U LCIE Bureau
Veritas (0081)
33, avenue du Général Leclerc
92260 Fontenay-aux-Roses, FRANCE
23 June 2020 Rob Bohland, Ex Authorized Person Minco Products, Inc
7300 Commerce Lane Minneapolis, MN 55432 USA
3. Installation Instructions
Type of protection increased safety “eb” for the Resistance Temperature
Detectors is obtained by the construction of the measuring element and its fit
in slots of the stator windings of rotating electrical machines, or within
protective enclosures in other equipment, in type of protection increased
safety “eb” per EN/IEC 60079-7, flameproof enclosure “db” per EN/IEC 60079-1,
or pressurized apparatus “p” per EN/IEC 60079-2.
For type of protection increased safety “eb”, the Resistance Temperature
Detector, mounted in the rotating electrical machine, must be subjected to the
dielectric strength tests, required for the rotating electrical machine.
The temperature detector must be installed in such a way that it is protected
against mechanical danger.
The leads of the Resistance Temperature Detector, for connection to the
measuring circuit, must be connected to suitable Ex eb terminals in a suitable
Ex eb enclosure.
4. Special Conditions of Use
Maximum voltage: £ 30 V
5. .Electrical Data
Measuring current: £ 10 mA Power (under fault conditions): £ 1.5 W
Test voltage dielectric strength test: 500 Vrms, duration 1 minute