Medical Facility Responsibility
WARNING: It is the responsibility of the end user to ensure all aspects
of installation are covered by following the full manual found at
https://www.amico.com/products/equipment-mounts/patient-monitor/capsule-
monitor-mounts/capsule-neuron-mounts.
Installation Tools
Installation
Reference NOTE: Tools for installation not provided by Amico
Accessories. Verify the weight of the monitor to be mounted. This product is
rated at 20 lbs total, including 5 lbs in the basket. The CAPSULE NEURON 2
must be mounted with the NIBP PACK as shown in Figure 2. The CAPSULE
NEURON 2 can only be mounted to CS-SLVP-ADA-00 without the NIBP PACK in a non-
flush configuration.
Mounting to AHM-4-/SSM-4-
Insert 3x FLAT HEAD SCREWS through the top of the MOUNTING PLATE and into
the DISK as shown in Figure 1 using a 1/8″ Hex Key/bit. Use the provided 3/16″
Hex Key to tighten and secure.
For Use with Capsule
Neuron 2 (Vitals Plus)
Insert 4x PAN HEAD SCREWS through 4x LOCK WASHERS through the back of the
MOUNTING PLATE and into the device (CAPSULE NEURON 2 and NIBP PACK) as shown
in Figure 2.![Amico CS-SLVP-ADA-00 Accessory Basket with Capsule Neuron 2
-
Mounting 1](https://manuals.plus/wp-content/uploads/2023/04/Amico-CS-SLVP- ADA-00-Accessory-Basket-with-Capsule-Neuron-2-Mounting-1.png) For Use with Power Supply Mount
-
Release the STRAP by opening the BUCKLE and pulling the STRAP out and ensuring that the LOOP is still on the STRAP as shown in Figure 3.
-
Place the POWER SUPPLY within the STRAP as shown in Figure 3.
-
Hold the POWER SUPPLY in position and insert the end of the STRAP into the BUCKLE and pull out to tighten the POWER SUPPLY before closing the BUCKLE
as shown in Figure 4. -
Dress the end of the STRAP through the LOOP and the CABLE into the CABLE CLIP as shown in Figure 4.
-
Repeat steps 3 and 4 for the second STRAP.
-
Troubleshooting Guide
Symptom | Possible Cause | Solution |
---|---|---|
Capsule Neuron 2 Vitals Plus is loose | Improper or loose mounting | |
configuration to Amico mount | Tighten set screws and refer to instructions |
(For Use with
Capsule Neuron 2 Vitals Plus)
The basket is loose| Improper or loose mounting configuration to Amico mount|
Refer to instructions (Mounting to AHM/SSM)
Maintenance
It is recommended that once every three (3) months, all locks, bolts, and screws are visually inspected for signs of product wear and tear or damage. Check the product for looseness in the mount or orientation, and ensure the adapter is secured to the rail or wall channel system. Ensure the set screws on the channel and (2) thumb screws are fastened to the tightest possible position and ensure the device is secure.
Warranty
During the term of warranty: Within the first twelve (12) months from the date
of shipment, Amico Accessories will repair or replace any part which is proven
to be defective at no cost. After the twelve (12) month period, Amico
Accessories will send the parts to the customer free of charge, however,
shipping and installation will be borne by the customer.
The warranty is valid only when the product has been properly installed
according to Amico Accessories specifications, used in a normal manner, and
serviced according to factory recommendations. It does not cover failures due
to damage which occurs in shipments or failures which resulted from accidents,
misuse, abuse, neglect, mishandling, alteration, misapplication or damage that
may be attributable to Force Majeure.
AMICO ACCESSORIES DOES NOT HONOR VERBAL STATEMENTS CONCERNING THE
WARRANTY.
The distributor and/or dealer are not sanctioned to create verbal warranties
about the product described in this agreement. Any statements will not be
honored or be made part of the agreement of sale. This document is the final
complete and exclusive terms of the agreement.
THIS WARRANTY IS INCLUSIVE AND REPLACES ALL OTHER WARRANTIES.
Amico Accessories shall not, under any circumstances be liable for incidental
or consequential damages including, but not limited to, profit, loss of sales
or injuries to person(s) or property.
Correction of non-compliance as noted above will result in completion of all
liabilities of Amico Accessories whether based on agreement, neglect or
changed materials, designs or specifications without notice.
All claims for warranty must first be approved by Amico Accessories Customer
Service Department: (info@amico-accessories.com or 1-877-264-2697). A
valid Return Goods Authorization number must be obtained from Amico
Accessories prior to commencement of any warranty claim.
Amico Accessories Inc.
85 Fulton Way, Richmond
Hill, ON L4B 2N4, Canada
www.amico.com
Toll Free Tel: 1.877.264.2697
Tel: 905.763.7778
Fax: 905.763.8587
Email: info@amico-accessories.com
AA-QG-CAPSULE-NEURON2-BASKET-MOUNT 09.06.2018
References
- Accessories.com is for sale | www.plmp.com
- Amico Group of Companies | Home Page
- Capsule Neuron Mounts | Amico Group of Companies
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>