Altronix AL624ET Linear Power Supply-Charger Installation Guide
- June 4, 2024
- Altronix
Table of Contents
Altronix AL624ET Linear Power Supply-Charger Installation Guide
Overview:
Altronix AL624ET Linear Power Supply / Charger converts a 115VAC 60Hz input to a low voltage DC output. This general purpose power supply has a wide range of applications for access control, security and CCTV system accessories that require additional power.
Specifications:
**Agency Listing:
**
- CE European Conformity.
Input:
- 115VAC, 60 Hz 1.2A.
Output:
- 12VDC @ 1.2A supply current.
- Filtered and electronically regulated output.
- Short circuit and thermal overload protection.
Battery Backup:
- Built-in charger for sealed lead acid or gel type batteries.
- Maximum charge current 300mA.
- Automatic switchover to stand-by battery when AC Fails.
- PTC battery protection.
Visual Indicators:
- AC input and DC output LED indicators.
Features:
- Power supply/charger with enclosure and TP1620 plug-in transformer (16.5VAC/20VA).
- Fits one (1) 12VDC/7AH or two (2) 12VDC/4AH batteries.
Mechanical:
- Enclosure Dimensions (H x W x D approx.): 8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm)
- Board dimensions (W x L x H): 3” x 2.5” x 1.125” (76.2mm x 63.5mm x 28.6mm)
Voltage Output/Transformer Selection Table:
Installation Instructions:
- Mount AL624 board in the enclosure (Fig. 1, pg. 2).
- Unit is factory set for 12VDC.
- Connect TP1620 plug-in transformer to the terminals marked [AC] (refer to voltage output/transformer selection table). Use 18 AWG or larger for all power connections (Battery, DC output). Keep power-limited wiring separate from non power-limited wiring (115VAC / 60Hz Input, Battery Wires). Minimum 0.25” spacing must be provided.
- Measure output voltage before connecting devices. This helps avoiding potential damage.
- Devices to be powered should be connected to the terminals marked [+ DC] and [DC – BAT], carefully observing polarity.
- Connect battery to the terminals marked [BAT +] and [DC – NEG] (battery leads included)
Note: When batteries are not used, a loss of AC will result in a loss of output voltage.
LED Diagnostics:
Terminal Identification:
Fig. 1
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone:
718-567-8181 | fax:
718-567-9056
website: www.altronix.com | e-mail:
info@altronix.com | Lifetime Warranty
IIAL624ET – Rev. 110599 F21U
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>