newform NFR69771 Wall-Mounted Bath Group Instruction Manual

June 9, 2024
newform

newform NFR69771 Wall-Mounted Bath Group Instruction Manual
newform NFR69771 Wall-Mounted Bath Group

WARNINGS FOR THE USE AND MAINTENANCE

  • This manual is an integral part of the product.
  • Keep it in good conditions and at hand throughout product’s life.
  • We recommend reading carefully this manual and all the instructions contained before using and installing the product.
  • The installation should be made by qualified staff in compliance with regulations in force.
  • As concerns the built-in items, test the system (inlets/ outlets) before completing the external covering.
  • The manufacturer is not liable in case of use of the product with purposes other than those provided for.
  • Do not leave the residues of the packaging in the home environment.
  • Do not hinder the water flow.
  • Totally avoid using metallic or abrasive sponges and detergents or abrasive products in order not to damage the surfaces.
  • Especially with new installations, in order to prevent impurities or debris penetrating into the tap and causing working problems, purge the system before activating the mixer.
  • Clean only with water and soap. Carefully rinse and dry with a soft cloth.
  • In order to maintain the mixer and its cartridge in the best and long-lasting conditions, we suggest to fit under-top valves with filter.

REFERENCES

REFERENCES

INSTALLATION PROCEDURE

INSTALLATION

Mixer fastening and connection.
Install the mixer be sure that the concealed part is perfectly lined up and parallel to the wall.

INSTALLATION

Mixer fastening and connection.
Tile paying attention to guarantee system safety shutting water off. Remove the protections as shown in the picture.

Respect the embedding limits in reference to the external wall facing line

INSTALLATION

Fastening external parts.
Install the decor plate (1) by interposing the sponges (2) and inserting the spout into the wall fitting. Screw the connection (3), insert the wall union (4) and fixin everything with the screw (5). Then screw the diverter button (6). Finally mount the handle to the cartridge (7) fixing it with the hexagon screw (8) and placing on its cover (9).

MAINTENANCE

OVERVIEW

CARTRIDGE REPLACEMENT
Remove the plug (1), unscrew the fastening screw (2) and remove the handle (3). Unscrew the fastening ring nut (4) and remove the cartridge (5).

AERATOR FILTER CLEANING
Unscrew the aerator filter (6) and blow into it to remove any dirt residues. We recommend cleaning after the first use and periodically repeating this operation in order to avoid flow rate reductions.

MAINTENANCE
In addition we recommend cleaning the taps exclusively with water and soap, avoiding using abrasive detergents (in powder or liquid), abrasive sponges or other products containing alcohol, acids or other aggressive substances. Newform s.p.a. will not respond to any damages caused by failure to observe the above rules.

SPARE PARTS

OVERVIEW

1 29571
2 10698
3 11902
4 16951
5 14720
6 10403
7 27578
8 24522
8.1 10698
8.2 10604
9 22248
10 38
11 13302
12 10972
13 23129
14 355
15 25025
16 17322

FLOW RATES

bar l/min
0 0
1 8,95
2 12,60
3 15,41
4 17,79
5 19,91

DIAGRAM

bar l/min
0 0
1 7,45
2 10,62
3 13,07
4 15,19
5 17,11

DIAGRAM

PACKAGING DISPOSAL

QR CODE

DISPOSAL OF THE EOL COMPONENTS

NEWFORM S.p.A.
via Marconi, 25/A – Frazione Vintebbio – 13037 Serravalle Sesia – (VC) Italy
Tel. +39/0163452011 (r.a.) www.newform.it newform@newform.it

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals