CONFETTI & STREAMER FX
PART01839 rev 01-02
STADIUMSHOT III Confetti and Streamer Fx
DISCLAIMER
Read this manual carefully before installing and/or using this product. Failure to read the manual and to follow the printed instructions may lead to personal injury and/or damage to the product.
© 2022 MAGICFX®
All rights reserved.
Nothing from this publication may be copied, reproduced and/or published by
means of printing, photocopying or by any other means, without the prior
written approval of MAGIC FX.
MAGIC FX reserves the right to modify specifications stated in this manual.
TRADEMARKS
Any brand names mentioned in this manual are registered trademarks of their
respective owners.
LIABILITY
MAGIC FX accepts no liability for claims from third parties arising from
unauthorised use, use other than that stated in this manual, and use other
than in accordance with the General Conditions registered at the Chamber of
Commerce.
We further refer to the General Conditions. These are available on request,
free of charge.
Although considerable care has been taken to ensure a correct and
comprehensive description of all relevant components, the manual may
nonetheless contain errors and inaccuracies.
Should you detect any errors or inaccuracies in the manual, we would be
grateful if you would inform us. This helps us to further improve our
documentation.
INTRODUCTION
Congratulations! You have bought a great new product from MAGIC FX.
This manual contains all information required for the intended use of the
equipment.
Deviation from the described intended use can result in a hazardous situation
and/or property damage.
This manual includes notes and warnings on safe operation of the equipment.
These notes and warnings are accompanied by the following icons. Read them
attentively!
Indicates a hazardous situation that, if not avoided, will result in earth or
serious injury. This signal word is to be limited to the most extreme
situations.
Indicates a hazardous situation that, if not avoided, could result in death or
serious injury.
Indicates a hazardous situation that, if not avoided, could result in minor or
moderate injury.
NOTICE Indicates information considered important, but not hazard related
(e.g. messages relating to property damage).
TARGET GROUP
This manual is targeted at authorised personnel in the event industry that
install and operate the STADIUMSHOT III and the required ARM SYSTEM.
Authorised personnel are those who:
- Are appointed by their supervisor to install and/or operate STADIUMSHOT III and the related ARM SYSTEM at the event.
- Are trained in recognizing and avoiding hazards related to SFX applications at events.
- Are familiar with the safety instructions of each involved ARM SYSTEM component.
- Are familiar with and abide by the applicable local, national and international laws and regulations.
LANGUAGE
This document contains the original instructions in English. In case you
require other languages please contact MAGIC FX.
ABBREVIATIONS
Abbreviation | Description |
---|---|
SFX | Special effects |
DMX | Digital Multiplex |
RDM | Remote Device Management |
ARM SYSTEM | MAGICFX® SFX SAFETY ARM SYSTEM |
ARM CONTROLLER | MAGICFX® SFX SAFETY ARM CONTROLLER |
E-STOP | MAGICFX® SFX SAFETY E-STOP |
TERMINATOR | MAGICFX® SFX SAFETY TERMINATOR |
STADIUMSHOT III | MAGICFX® STADIUMSHOT III |
Abbreviations |
REVISION TABLE
Doc nr| Revision| Date| Description| Author|
Approved
---|---|---|---|---|---
PART01839| 01-00| 05-03-2020| Initial release| CSK| PvdW
PART01839| 01-01| 02-10-2020| Accessories| NvE| LL
PART01839| 01-02| 10-11-2022| Updated ARM SYSTEM| TF| PvdW
DESCRIPTION
The STADIUMSHOT III is a special effects machine that shoots confetti or
streamers into the air. The STADIUMSHOT III is intended for outdoor use. At
the desired moment the air flows from the tank via the barrel out of the
machine. This results in the confetti or streamers leaving the output pipe at
high velocity into the air up to 40 metres far*.
The machine is equipped with an onboard compressor to pressurize the air tank.
The pressure can be set via the machine’s display to accommodate different
venues. When the machine is loaded with MAGICFX CONFETTI or STREAMERS, a
single push on the physical button on the STADIUMSHOT III will charge the air
tank to the set pressure, and maintain the pressure at the set value until the
shot is fired. If for any reason the pressure drops, and cannot be
compensated, the system will block the shot for safety reasons.
The STADIUMSHOT III is operated with DMX and RDM, or with an external low
voltage pyro controller (24 V). The STADIUMSHOT III can be operated in
sequence with multiple machines. Furthermore, the STADIUMSHOT III is
configured for safety control with an ARM SYSTEM.
- The output distance depends on input material, air pressure and environmental conditions.
1.1 MAIN PARTS
1.2 TECHNICAL DATA
Product | Product Name | STADIUMSHOT III |
---|---|---|
Product Code | MFX0408 | |
Product Type | CONFETTI & STREAMER FX | |
Main Dimensions | Length | 600 mm |
Width | 400 mm | 15.8 in |
Height | 870 mm | 34.3 in |
Weight | Weight | 86 kg |
Environment | Minimum Temperature | -10 °C |
Maximum Temperature | 70 °C | 158 °F |
Humidity (Relative) | 20 % to 90 % (non condensing) | |
Electrical | Voltage Input (Vac) | 100 – 250 Vac |
Voltage Frequency | 50 – 60 Hz | |
Power Consumption (Vac) | 350 W | |
Power Connector (Vac) | Neutrik® power CON TRUE1 (in & out) | |
Controlling | Control Options | DMX / 24 Vdc |
Control Protocols | DMX512-A (ANSI E1.11) RDM (ANSI E1.20) | |
Control Connectors | Neutrik® 5-pole male / female XLR / 4 mm banana socket | |
Safety controlling | ARM Connector | Neutrik® ether CON, RJ45 (in&out) |
Configuring | Configure Options | On Device & RDM |
Pressure tank | Maximum Pressure | 8 bar |
Volume | 10.9 L | 2.9 gal |
Usage | Consumable(s) | MAGICFX® CONFETTI & STREAMERS |
1.3 PRODUCT IDENTIFICATION
1.4 ARM CONTROL
NOTICE The STADIUMSHOT III cannot be operated without connection to an ARM CONTROLLER in an ARM SYSTEM.
The STADIUMSHOT III is configured for safety control with an ARM SYSTEM. The
STADIUMSHOT III cannot be operated without the safety signal from the control
unit of the ARM SYSTEM: The ARM CONTROLLER. When there’s no signal, the air
valve from the tank is switched off. The pressurized air can’t leave the tank,
revenging the STADIUMSHOT III from producing any high-risk SFX output. As a
result, any related hazard/or property damage is stopped and prevented.
The ARM CONTROLLER is equipped with a key switch to arm/disarm the connected
SFX machine(s), an emergency stop button, and a reset button. The ARM SYSTEM
is wired with EtherCON cables that carry the safety signal from the ARM
CONTROLLER.
For more information about the ARM SYSTEM and to learn how to configure a
complete safety system, refer to the ARM SYSTEM Configuration Manual
(PART02323).
For more information about the ARM CONTROLLER and to learn how to correctly
set up and use the ARM SYSTEM, refer to the ARM CONTROLLER User and
Installation Manual (PART01882).
1.5 DMX CONTROL
The STADIUMSHOT III is controlled with 1 enable address and 1 operational
address.
DMX Address | Address range |
---|---|
Enable address | 1 – 512 |
Start address (Trigger) | 1 – 512 |
DMX addresses |
The enable address cannot be the same as the operational address. Operating of these addresses results in the following:
DMX Address | DMX Value (decimal) | Result |
---|---|---|
0 | 99 | Device disabled |
Enable address | 100 | 154 |
155 | 255 | Device disabled |
Start address (Trigger) | 0 | 199 |
200 | 255 | Fire |
Operation of the DMX addresses |
When you link multiple machines with DMX, we advise you to use the same enable address for all machines.
Always plug in a DMX Terminator into the DMX output of the final unit in the control sequence. Using a DMX Terminator improves signal reliability.
1.6 DISPLAY PANEL
The display panel is located on the backside of the STADIUMSHOT III. Check the following menu structure for all options in the menu. Use the buttons for navigation and selection. The left-hand LED blinks red when DMX is active. The right-hand LED continuously lights red when an error is present.
Menu function | Explanation |
---|---|
Lock/Unlock Controller | Holding the Lock button for more than 5 seconds will |
“lock” the display functions. Meaning buttons will not respond. This to avoid
accidental change of parameters via display.To unlock, hold the Unlock button
for more than 5 seconds.
Reset Errors| In case there is a locking error present, this button will reset
the appliance. If the fault does not persist, the locking error will not
reappear.
DMX Start Address (1-512)| Setting the DMX start address. DMX Enable Address
(1-512) Setting the DMX Enable Address. DMX Footprint This parameter indicates
the DMX footprint, in other words the amount of sequential channels used by
the appliance. This does not include the enable channel.
DMX input (XLR/ARM)| Make sure that the DMX/RDM settings on your machine match
your wiring setup. If the DMX signal runs separately over 5-pole XLR cables,
make sure that XLR is selected. If a combined DMX and ARM signal runs over the
ARM data (EtherCON) cables, make sure that ARM is selected.
RDM (On/Off)| Use this function to turn on/off the RDM functionality.
Pressure (4-8 Bar)| Use this function to set the pressure between 4 and 8 bar.
Pyro Input Control (On/Off)| Use this function to switch between the powered
control modes DMX and pyro.
Display Dimmer (On/Off)| Turn display dimmer on or off. If turned on, the
display is dimmed automatically 30 seconds after the last button push.
Factory Defaults (Yes/No)| Restores the appliance factory default settings.
---|---
Type (Alarm/Error)| Toggle between the occurred locking error (Alarm) list,
and blocking error (Error) list. Locking errors need intervention by user,
although they are “auto-reset” 3 times before the appliance remains in error
until reset by user. Blocking errors clear when the triggering fault
disappears. 16 locked, and 16 blocked errors are logged. Top of the list shows
the last occurring error.
Serial Number (DDDDD)| Appliance serial number as also printed on the
appliance label.
Unique ID (HHHHHHHHHHHH)| UID number as the appliance appears in the RDM
device list after running discovery.
Software Version| Installed software version.
Software CRC| CRC of the functional software.
Bootloader CRC| CRC of the bootloader software.
Build Date| Release date of functional software.
Up-Time (DDDD:HH:MM:SS)| Time counter which indicates how long the appliance
has been powered in total.
Shots Fired| Number of shots fired with DMX.
Pump Time (DDDD:HH:MM:SS)| Time counter which indicates how long the pump has
been on in total.
| Menu functions
1.7 RDM CAPABILITY
Remote Device Management Protocol (RDM) is an enhancement of the DMX512
communication protocol. RDM can be used for configuration and status
monitoring while DMX512 takes care of the default controlling. For RDM you
will need a RDM compatible controller. The following RDM parameters are
supported by the STADIUMSHOT III.
Parameter ID | Discovery | GET | SET |
---|---|---|---|
DISC_UNIQUE_BRANCH | X | ||
DISC_MUTE | X | ||
DISC_UN_MUTE | X | ||
DEVICE_INFO | X | ||
SUPPORTED_PARAMETERS | X | ||
SOFTWARE_VERSION_LABEL | X | ||
DEVICE_MODEL_DESCRIPTION | X | ||
MANUFACTURER_LABEL | X | ||
SLOT_DESCRIPTION | X | ||
SENSOR_DEFINTION | X | ||
Parameter ID | Discovery | GET | SET |
--- | --- | --- | --- |
SENSOR_VALUE | X | ||
DMX_START_ADDRESS | X | X | |
IDENTIFY_DEVICE | X | X | |
DEVICE_LABEL | X | X | |
FACTORY_DEFAULTS | X | X | |
RESET_DEVICE | X | ||
RDM parameters |
RDM parameters are subject of change due to software updates. Contact MAGIC FX for the latest information and updates.
1.8 ACCESSORIES
Code | Product | Included |
---|---|---|
MFX0404 | COMPRESSION CAPS TAPE 50 m X 50 mm | |
MFX0407 | 25 CAPS + 25 CORES FOR MAGICFX® STADIUMSHOT | |
MFX0423 | STADIUMSHOT III SECURE STRAP | |
MFX0424 | STADIUMSHOT III RAIN COVER | |
MFX0313 | Schake to Neutrik® power CON TRUE1 – cable 1.5 m | |
Accessories |
For information about the accessories of the ARM CONTROLLER (MFX3220), refer to the ARM CONTROLLER User and Installation Manual (PART01882).
1.9 INPUT & OUTPUT
The output pipe has a payload of 5 litres and can be filled with MAGICFX®
confetti or streamers. The maximum load per shot depends on the type of input
material. The output distance depends on the type of input material and the
load.
Consumable| Amount| Max. Output distance| Min.
Pressure
---|---|---|---
MAGICFX® PAPER CONFETTI| 2 kg| 20 m| 66 ft| 4 bar| 58 psi
MAGICFX® METALLIC CONFETTI| 3 kg| 20 m| 66 ft| 4 bar| 58 psi
MAGICFX® STREAMERS 20 m x 5 cm| 8 Polybags| 40 m| 131 ft| 8 bar| 116 psi
MAGICFX® STREAMERS 20 m x 2.5 cm| 9 Polybags| 40 m| 131 ft| 8 bar| 116 psi
MAGICFX® STREAMERS 10 m x 5 cm| 15 Polybags| 35 m| 115 ft| 8 bar| 116 psi
MAGICFX® STREAMERS 10 m x 2.5 cm| 18 Polybags| 35 m| 115 ft| 8 bar| 116 psi
MAGICFX® STREAMERS 10 m x 1.5 cm| 20 Polybags| 35 m| 115 ft| 8 bar| 116 psi
| Projectile types and related loads and output
NOTICE Wind and other weather circumstances will influence the output distance. The given values are estimated values.
SAFETY
The machine has been designed and constructed in such a manner that it can be
used safely. This applies to the use, the circumstances and the regulations as
described in this documentation. Reading this documentation and following the
instructions are therefore necessary for everyone who is authorised to work
with the machine.
The machine must be used in surroundings that:
- Have a stable temperature of between -10 and 70 °C.
- Have a relative humidity degree between 20 % and 90 % (non condensing).
- Are free of dust, corrosive gases and high concentrations of organic vapours.
- Are not situated in the vicinity of a source of vibration.
2.1 GENERAL SAFETY RULES
- Only authorised persons may carry out work with the STADIUMSHOT III.
- Do not use the STADIUMSHOT III if there are people or animals in the direct output.
- Do not use the STADIUMSHOT III if alterations have been made other than by or on behalf of MAGICFX®.
- Make sure that children, unauthorised people and animals do not obtain access to the STADIUMSHOT III.
- Make sure there are no freestanding objects or objects that can be damaged by the machine within the output distance.
- Make sure that streamers and/or confetti cannot come into contact with high-voltage lines/power pylons, as this can result in electrocution.
- Do not connect more units to a single electrical circuit than the installed fuse is able to handle. (Calculate the summed load with the electrical data from Chapter 1)
- Do not remove any safeguards, safety caps and safety symbols.
- All required safety devices must be in good condition and function properly.
- Ensure sufficient lighting of the surroundings.
- Keep the workplace clean.
2.2 TRANSPORT
- Check the pressure level on the tank pressure meter before every transport. If necessary depressurize the system by opening the vent valve.
Do not transport or move the STADIUMSHOT III when the tank is pressurized. Transporting or moving the machine when pressurized can result in death or serious injury.
2.3 COMPRESSED AIR
- If an external air source is used, always use an inspected and certified professional compressor with an air output of maximum 8 bar to fill the tank. Carefully read the manual of the compressor before use.
- Never leave the tank pressurized for more than 15 minutes.
- The machine is equipped with a pressure relief valve that automatically depressurizes the system when the maximum allowed pressure of 8 bar is exceeded. Nevertheless regularly check the tank pressure meter to make sure the pressure in the tank is stable and does not exceed 8 bar. If necessary depressurize the system by opening the ventilation valve.
2.4 OUTDOOR USE
The STADIUMSHOT III is designed for outdoor use.
The STADIUMSHOT III can be used indoors in large event halls and arenas.
Please refer to page 17.
2.5 RIGGING
Please follow the European and national guidelines for safe rigging and
trussing.
2.6 NOISE LEVEL
The environmental noise level as measured at the ear is greater than 70 dB(A).
This level of noise is only reached during the short instances that the output
is active. Always wear hearing protection when you are within 5 metres of the
machine during operation.
2.7 CONFETTI/STREAMERS
Always shoot streamers at a minimum of 8 bar pressure to unfold them
completely. Shooting streamers at a lower pressure can lead to death or
serious injury.
Using any other objects other then MAGICFX® CONFETTI or STREAMERS or other
approved MAGICFX ® consumables can lead to death or serious injury.
2.8 SAFETY SYMBOLS
Symbol
| Meaning
---|---
| Read the manual carefully before use!
| Wear certified ear protection!
| Safety symbols
2.9 PRECAUTIONS FOR OPERATION
Using a damaged or an improper installed machine can lead to death, serious
injury or property damage. Always inspect the machine thoroughly before
operation.
Unauthorized operation of the machine can lead to death, serious injury or
property damage. Never leave the machine and the power switch unattended when
the machine is ready for use.
Do not use the STADIUMSHOT III if alterations have been made other than by or
on behalf of MAGICFX®.
Make sure that streamers and/or confetti cannot come into contact with high-
voltage lines/power pylons, as this can result in electrocution.
Missing or obscured safety symbols on the machine can lead to death, serious
injury or property damage. Make sure all safety symbols are correctly in place
and visible, see Section 2.7.
Always install the output pipe before operating the machine.
Make sure there are no objects near the output that can be damaged or
overthrown by the STADIUMSHOT III.
Always keep the output zone as shown in the image below clear of all people,
animals and objects. Not doing so results in death or serious injury.
Always create a safety zone around the machine with a radius of 5 meters / 16.5 feet. Make sure unauthorized personnel, animals and objects are clear of this area. Not doing so can result in death or serious injury.
INSTALLATION AND USE
3.1 INSTALL THE MACHINE
-
Bring the cased machine to the desired location.
-
Place the machine in its final position and set the brakes.
-
Apply a lashing ratchet to the strap plates on the side of the machine to fixate the machine and prevent it from moving.
Always make sure to properly fixate the machine on a stable and suited surface. Not doing so can result in death or serious injury.
NOTICE Do not apply more than 100 kg on the strap plate. The flight case may break down. -
Unlock and remove the flight case cover.
-
Remove the output pipe.
-
Pull the locking clamps downwards to unlock and rotate them upwards.
-
Place the output pipe in the coupling while holding the locking clamps upwards.
-
Lock the output pipe in place with the locking clamps.
-
Pull the clamps outwards to check if the locking pins are properly locked in place. If not: remove the output pipe and repeat step 5 and 6.
Never use the machine when the clamps are not locked or working properly. Not doing so can result in death or serious injury. -
Pull the index plunger and set the tank in the desired position. Make sure the index plunger is properly in place.
Never use the machine when the index plunger is not properly in place or working properly. Not doing so can result in serious injury or death. -
Take the necessary safety precautions, see Section 2.8.
3.2 CONNECT THE MACHINE
-
Install the ARM CONTROLLER in compliance with the instructions from the ARM CONTROLLER User and Installation Manual (PART01882).
-
Connect the Power Con TRUE1 power cable to the power input of the STADIUMSHOT III. Connect the other end to a 100-250 Vac (50-60 Hz) power source.
-
Connect the correct cables between the ARM CONTROLLER, the STADIUMSHOT III, the control equipment, and other ARM SYSTEM components and machines
(if applicable). Check the following variants for connection details.
A The STADIUMSHOT III is controlled with DMX. The DMX signal and the ARM signal have separate cables.B The STADIUMSHOT III is controlled with pyro (24V).C The STADIUMSHOT III is controlled with DMX. The DMX signal and the ARM signal are combined. -
If controlled with DMX: Use the display and buttons or a RDM controller to assign DMX addresses, see Chapter 1.
For more connection and configuration options, refer to the ARM SYSTEM Configuration Manual (PART02323).
It is possible to fire the machine without connecting the Power Con TRUE1
female connector. Note that the compressor will not work without connecting
power and the warning LED will not light up when enabling the ARM CONTROLLER.
Pressure safety checks will not work and it is possible to shoot confetti and
streamers at an unsafe pressure. See Section 1.8.
Do not connect more units to a single electrical circuit than the installed
fuse is able to handle. (Calculate the summed load with the electrical data
from Chapter 1)
NOTICE Insert a TERMINATOR in the last ARM output of each line to close
the safety circuit. The ARM SYSTEM will not work when a line remains open.
NOTICE Always plug in a DMX Terminator into the DMX output of the final
unit in the control sequence. Using a DMX Terminator improves signal and
reliability.
3.3 FILL WITH CONFETTI AND/OR STREAMERS
Make sure the vent valve is open and the gauge pressure is 0 bar. Not doing so
can result in death or serious injury.
-
Place a lifting core in the bottom of the output pipe.
Make sure the lifting core lies flat and closes off the hole in the output pipe! -
Fill the output pipe with confetti and/or streamers.
Check Chapter 1 for the maximum amount per approved type of input. -
Place a pressure cap on top of the output pipe.
-
Secure the pressure cap to the output pipe with special pressure cap tape.
3.4 FILL WITH PRESSURIZED AIR
Always keep the shooting direction clear of persons, animals or objects. Not
doing so will result in death or serious injury.
Always make sure unauthorized persons, animals or objects are not able to get
in front of the shooting direction. Not doing so will result in death or
serious injury.
If the internal compressor of the STADIUMSHOT III is used, follow the next steps:
- Power the machine.
- Close the vent valve.
- Set the desired pressure in the menu, see Section 1.5.
- Press the compressor on/off button on top of the machine. The compressor on/off button starts blinking.
- After a maximum of 2.5 minutes, the pressure will be at the maximum pressure of 8 bar. The compressor will automatically stop at the set pressure and the compressor on/off button turns red.
If an external air source is used for the first time, follow the next steps. If an external air source is used when the desired quick connector is installed, follow step 5 only:
- Remove the top cover, see Section 4.1.
- Remove the elbow part of the 3-way coupling with an adjustable open-ended spanner.
- Replace the end plug in the elbow with the desired quick connector suitable for the desired quick connector.
- Close the top cover, see Section 4.1
- Connect the hose from an external air source to the quick coupling. Only use an air source with an air filter with a maximum output of 8 bar.
3.5 SHOOT WITH DMX OR PYRO
Make sure that the described safety zone is clear of people, animals and
objects. Not doing so results in death or serious injury.
If DMX is used, follow the next steps:
- Make sure that the prescribed safety zone is free from persons and objects.
- Set the safety key on the ARM CONTROLLER in the ON position. The FX LED lights in red, indicating the system is now armed and the STADIUMSHOT III and other connected SFX machines are ready to be operated.
- Activate the enable address. The FX LED begins to flash.
- Set the DMX value for the effect channel between 200 and 255 to shoot.
- Enjoy the view!
- Turn the enable address and the effect channel back to 0.
- Set the safety key in the OFF position to disarm the ARM SYSTEM and disable operation of the STADIUMSHOT III and other connected SFX machines.
If pyro is used, follow the next steps:
- Make sure that the prescribed safety zone is free from persons and objects.
- Set the safety key on the ARM CONTROLLER in the ON position. The FX LED lights in red, indicating the system is now armed and the STADIUMSHOT III and other connected SFX machines are ready to be operated.
- Activate the pyro controller.
- Enjoy the view!
- Deactivate the external low voltage pyro controller (24V).
- Set the safety key in the OFF position to disarm the ARM SYSTEM and disable operation of the STADIUMSHOT III and other connected SFX machines.
3.6 USE THE EMERGENCY STOP
- When an emergency occurs or is about to occur with the STADIUMSHOT III, you press the emergency stop button on the ARM CONTROLLER or on an external E- STOP (if present). As a result the pressurized air can’t leave the tank and any related hazard/or property damage is stopped and prevented.
- Set the safety key on the ARM CONTROLLER to the OFF position.
- Resolve the emergency situation and inspect the STADIUMSHOT III.
- Release the emergency stop and perform a reset. For instructions, refer to the ARM CONTROLLER User and Installation Manual (PART01882).
- If DMX is used, set the enable and effect channel back to 0.
The machine is ready to be used again.
3.7 CLEAN UP
- Open the vent valve to release the pressure and make sure the gauge pressure is 0 bar.
- Disconnect the cables.
- Rotate the tank to the vertical (0) position.
- Pull the locking clamps downwards to unlock and rotate them upwards.
- Remove the output pipe from the coupling.
- Store the output pipe in the flight case.
- Remove the lashing ratchet.
- Place and lock the flight case cover.
- Release the brakes.
MAINTENANCE
To achieve the maximum service life of the machine you must regularly clean
the machine, replace the air-in filter and test if it is functioning
correctly. Regularly clean dust and dirt from the compressor cooling fins and
motor housing.
Contact MAGIC FX if the machine is not functioning correctly.
Do not replace parts yourself other than specified in this chapter; always
consult MAGIC FX.
Never clean the machine or do maintenance to the machine with the tank
pressurized. Always make sure the vent valve is open.
4.1 CLEANING
- Remove the top cover by removing the six screws of the top cover with a TORX20 screwdriver.
- Clean the machine with air or a vacuum cleaner.
- Attach the top cover to the machine with the TORX20 screws.
4.2 REPLACE THE AIR-IN FILTER
NOTICE Do not run the machine without using an air-in filter. The
compressor may be seriously damaged.
NOTICE Replace the air-in filter element periodically. The replacement
frequency depends on operating frequency and operating environment. For
frequent use in dusty environments, MAGIC FX recommends to replace the air-
infilter element once a month.
- Remove the handle of the machine by removing the ten imbues 3 screws of the handle.
- Remove the air-in filter housing from the machine by rotating clockwise.
- Open the plastic housing of the air-in filter.
- Replace the air-in filter.
- Close the plastic housing of the air-in filter.
- Screw the air-in filter housing back into the machine.
- Attach the handle of the machine with the imbues 3 screws.
TROUBLESHOOTING
In case the display shows one of the following error or alarm codes, act accordingly:
Code | Meaning | Solution |
---|---|---|
016 | Tank does not reach the set pressure | • Make sure the vent valve is |
entirely closed.
• If the problem is not solved contact MAGIC FX.
018| Pressure keeps dropping| • Make sure the vent valve is entirely closed.
• If the problem is not solved contact MAGIC FX.
019| Misfire (system error)| • Open the vent valve and make sure the gauge
pressure is 0 bar.
• Close the vent valve.
• Press the compressor on/off button to pressurize again.
• Wait until the STADIUMSHOT III has built up the set pressure.
• Fire again.
• If the problem is not solved contact MAGIC FX.
121| Orientation of device out of safe bounds| • The machine is tilted more
than allowed. Turn the machine to a level position.
123| Pressure too high| • Open the vent valve.
• Close the vent valve when the warning has disappeared.
206| Pressure not rising| • Make sure the vent valve is entirely closed.
• Press the compressor on/off button to pressurize again.
• If the problem is not solved contact MAGIC FX.
Always contact MAGIC FX if any malfunctions or errors occur that cannot be solved with the instructions as described in this manual.
CORRECT DISPOSAL
This symbol on the product and / or accompanying documents means that used electrical and electronic products should not be mixed with general household waste. For proper treatment, recovery and recycling, please take this product to designated collection points where it will be accepted free of charge. Alternatively, in some countries you may be able to return your products to your local retailer upon purchase of an equivalent new product. Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please contact your local authority for further details of your nearest designated collection point. Penalties may be applicable for incorrect disposal of this waste, in accordance with your national legislation.
EC DECLARATION OF CONFORMITY
According to Annex III A Machinery Directive 2006/42/EC
MAGIC FX B.V. declares as manufacturer and composer of the technical
construction file that the product with the following specifications:
Name machine | : STADIUMSHOT III |
---|---|
Type | : MFX0408 |
Voltage | : 100-250 Vac 50-60 Hz/24 Vdc |
Max. working pressure | : 8 bar / 116 psi |
Volume | : 10.9 L |
Serial number | : on product |
Year of construction | : on product |
Is in conformity with the minimal safety regulations as stated in the following directive(s):
- LVD (2014/35/EU) Low Voltage Directive
- EMC (2014/30/EC) Electro Magnetic Compatibility
- RoHS (2011/65/EU) Restriction of the use of certain Hazardous Substances
- WEEE (2012/19/EU) Waste Electrical & Electronic Equipment
- PED (2014/68/EU) Pressure Equipment
The following harmonized standards were applied:
- NEN-EN-ISO 12100:2010, Safety of machinery – General principles for design – Risk assessment and risk reduction.
- NEN-EN-IEC 60204:2018, Safety of machinery – Electrical equipment of machines – Part 1: General requirements.
- NEN-EN-IEC 61000-6-3:2007/A1:2011/C11:2012, Electromagnetic compatibility (EMC) – Part 6-3: Generic standards – Emission standard for residential, commercial and light-industrial environments.
- NEN-EN 13445-1:2014, Unfired pressure vessels.
Original declaration of conformity
Translation of the original declaration of conformity
Name manufacturer | : MAGIC FX B.V. |
---|---|
Address | : Schoolroom 27, 5281 RE BOXTEL |
Country | : The Netherlands |
CEO | : B. Froude |
Date | : 11-2-2020 |