SAITEK BR9N Coffee Machine Mate-Milk Cooler User Manual
- June 6, 2024
- SAITEK
Table of Contents
Milk cooler
Operation Manual
Model: BR9N, BC9N,
BR9CN, BC9CN
To ensure use of this appliance and your safety, please read the following instructions completely before operating this appliance.
GENERAL INFORMATION
1.1 Foreword
The purpose of this document is to provide important information regarding the
installation, use, and maintenance of the cooler. Before any operation, you
should read carefully the information contained in this manual.
The manufacturer assumes no liability for parts or labor coverage for
component failure or other damages resulting from improper usage, installation
or failure to clean and/or maintain the product as set forth in these
instructions.
1.2 GENERAL USE
The cooler is not designed for external (outdoor) placement or environments
that subject it to the actions of atmospheric agents (rain, direct sunlight)
The manufacturer is not responsible for damages resulting from the improper
use of the product.
This appliance can be used by children aged 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning the
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent, or similarly qualified persons in order to avoid a hazard.
– WARNING: Keep ventilation openings, in the appliance enclosure or in the
built-in structure, clear of obstruction.
– WARNING: Do not use mechanical devices or other means to accelerate the
defrosting process, other than those recommended by the manufacturer.
– WARNING: Do not damage the refrigerant circuit.
– WARNING: Do not use electrical appliances inside the food storage
compartments of the appliance, unless they are of the type recommended by the
manufacturer.
Do not store explosive substances such as aerosol cans with a flammable
propellant in this appliance.
Correct Disposal of this product
This marking indicates that this product should not be disposed of with other
household wastes throughout the EU. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources.
To return your used device, please use the return and collection systems or
contact the retailer where the product was purchased. They can take this
product for environmentally safe recycling. If the supply cord is damaged, it
must be replaced by the manufacturer, its service agent, or similarly
qualified persons in order to avoid a hazard.
Caution: risk of fire.
1.3 TESTING
The cooler is shipped ready for use.
The temperature control is preset from the factory.
As needed, the temperature control can be adjusted Clock-wise to make the
product “Colder”, the control can be adjusted Counter
Clockwise to make the product “Warmer”.(for model BR9N, BC9N).
In the touch control screen design, as needed, the temperature control can be
adjusted Press ‘ ‘ button for 0.5 seconds then press the button on the control
panel to decrease the temperature and the button to increase the temperature
inside the cooler. The temperature will lash for confirmation. The temperature
range is from -1°C to 5°C.Press button once to turn the light on/off. (for
model BC9CN,BR9CN). The milk will be under 4 °C
We don’t recommend customers adjust. Because the regulation too cold Setting can cause the freezing of the products. The best cooling performance is achieved if the unit is optimally filled and the air circulation inside the unit is unobstructed by the products inside the refrigerator.
1.4 RESPONSIBILITY OF THE CUSTOMER
Ensure that the electrical outlet is connected effectively to the earth
(ground), suitable to provide the voltage indicated on the data plate. Make
sure that the cooler is placed on a level surface.
TECHNICAL DATA
2.1 MATERIALS AND REFRIGERANTS
Interior or exterior surfaces that come into contact with the products are
made of galvanized steel. Aluminum or non-toxic plastic materials.
The Refrigerant used is approved by government regulations.
The type and quantity of the gas-charged, in the refrigeration unit, are
indicated on the data plate.
INSTALLATION
For safe proper operation, follow the manufacturer´s instructions reported in this section.
3.1 POSITIONING
The cooler must be placed in an adequately ventilated room. Keep away from
heat sources, such as radiators or air conditioning pipes. Allow free air
circulation to the refrigerator unit.
The ambient temperature must not be higher than 40°C.
This appliance climate class is 3,4,5.
Restroom
climate class
| Dry bulb
temperature°C| Relative
humidity%| Dewpoint°C|
Waterweightin
drying/kg
---|---|---|---|---
0| 20| 50| 9.3| 7.3
1| 16| 80| 12.6| 9.1
2| 22| 65| 15.2| 10.8
3| 25| 60| 16.7| 12
4| 30| 55| 20.0| 14.8
5| 40| 40| 23.9| 18.8
6| 27| 70| 21| 15.8
7| 35| 75| 30| 27.3
3.1.1 Cooler Leveling: To provide the best performance the cooler must remain level.
3.2 ELECTRICAL CONNECTION
WARNING DO NOT USE EXTENSION CORDS
The cooler works on a single-phase voltage (220-240V 50/60Hz) power supply.
To switch on the cooler, insert the plug into the outlet.
Ensure that:
The electrical outlet must be provided with an efficient ground, the voltage
and the frequency of the electrical line matches those indicated on the data
plate. If unsure about the efficiency of the ground, have your electrical
circuit checked by a qualified technician.
When the cooler is operating, check that the supply voltage is not dropping
or increasing under/over +10% the rated voltage (187 Volts to 242 Volts)
If the light is damaged, it must be replaced with the same size, power, and
shape. and must be replaced by the manufacturer or its service agent
The manufacturer is not responsible for damages or accidents arising from the
misuse or disregard of electrical laws relevant to the country where the
cooler is used.
MAINTENANCE
- Before cleaning the cooler always remember to unplug it.
- Unplug the cooler at the electrical outlet; never pull the service cord.
- Do not use sharp objects for cleaning.
- Clean the inside cabinet of the cooler with a clean damp cloth or with neutral soap. Avoid damage by never using abrasive or flammable cleaning products.
- Clean the condenser at least once a month with a vacuum cleaner or a brush to eliminate dust accumulation.
- Do not wash the cooler with direct, or high-pressure water jets.
When the relative humidity is more than 55%, there will be condensation on the door glass, it’s normal and unavoidable.
TROUBLESHOOTING
Often problems that occur during normal operation can be resolved without the
assistance of a specialized technician, verify the following:
a) The appliance does not operate.
-Check that the plug is correctly in the electrical outlet.
-Verify that there is the voltage at the electrical outlet
b) The product is too warm.
-Check the setting of the thermostat. (See Testing Section)
-Check the closing of the door, and ensure the door gasket seals.
-Check that the interior fan is operating, and not blocked.
-Check and clean the condenser
c) The appliance is excessively noisy.
-Verify the equipment is level.
-Ensure that the equipment is not touching other equipment that could cause vibration.
Prepare to answer the following:
-The type of problem: (electrical, mechanical)
-The model, code, and a serial number of the cooler can be found on the manufacturer label attached to the interior wall of the cooler.
WIRING DIAGRAM
Read User Manual Online (PDF format)