Syvecs LTD GDI12 Channel GDI Driver Owner’s Manual

June 9, 2024
Syvecs LTD

Syvecs LTD GDI12 Channel GDI Driver Owner’s Manual

GDI12 Driver

This document is intended for use by a technical audience and describes a number of procedures that are potentially hazardous. Installations should be carried out by competent persons only.
Syvecs and the author accept no liability for any damage caused by the incorrect installation or configuration of the equipment.
Please Note that due to frequent firmware changes certain windows might not be the same as the manual illustrates. If so please contact the Syvecs Tech Team for Assistance.Support@Syvecs.com

The Syvecs 12 Channel GDI Driver allows 12 GDI Injectors to be driven all from one box, designed to work with all GDI
Solenoid injectors including parts from VAG Group, Ford, GM and Bosch via Updatable Software which can be flashed to the
Unit via a USB in the field BUT as the unit is sealed on shipping its best best done at build-time before shipping.
Designed to work with all types of Engine Management system, the input stage of the driver for each GDI Injector output can receive either IGBT (Pull to Ground) or TTL (5v).
Packaged in a lightweight CNC billet aluminium case with a waterproof 35way AMP Connector.
Default Configuration = 10Amps Boost @ 65v, 6Amps Peak, 4Amps Hold
Maximum available current 20Amps
Adjustment of any of the following parameter can be done to suit any Solenoid Injector.

Parameter Description
Boost Current threshold in Boost Phase
Peak Current threshold in Peak Phase
Hold Current threshold in Hold Phase
Peak_Off Fixed time for high side switch off in Peak phase
Peak_TOT Fixed time for end of Peak phase
Bypass Fixed time for Bypass phase
Hold_Off Fixed time for high side switch off in Hold phase
Hold_TOT Fixed time for end of Hold Phase (timeout)

Each High Side Driver output has a current sensor present in the circuit which means that 2 injectors can’t be driven at the same time on each High Side output so it’s important to assign the firing points of each Injector carefully.

Example1: V10 Engine with Firing order – 1, 6, 5, 10, 2, 7, 3, 8, 4, 9
Best to Assign as below where the spacing between each Injector on one High side is 360 which is more than enough required injection time for a Direct injection engine.

HS1,2 – Injector 1 and 7
HS3,4 – Injector 6 and 3
HS5,6 – Injector 5 and 8
HS7,8 – Injector 10 and 4
HS9,10 – DI Pump1 & 2 as Default HS11, 12 – – Injector 2 and 9
Example2: V6 Engine with Firing Order – 1, 2, 3, 4, 5, 6
HS1,2 – Injector 1 & 4 HS3,4 – Injector 2 HS5,6 – Injector 3 HS7,8 – Injector 5
HS9,10 – DI Pump1 & 2 as Default HS11, 12 – Injector 6

Pinouts

Pin Name Notes
1 LS1 Injector Low Side Output 1
2 LS2 Injector Low Side Output 2
3 LS3 Injector Low Side Output 3
4 LS4 Injector Low Side Output 4
5 LS5 Injector Low Side Output 5
6 LS6 Injector Low Side Output 6
7 LS12 Injector Low Side Output 12
8 LS11 Injector Low Side Output 11
9 LS10 DI Pump2 Low Side Output / Injector Low Side Output 10
10 LS9 DI Pump1 Low Side Output / Injector Low Side Output 9
11 LS8 Injector Low Side Output 8
12 LS7 Injector Low Side Output 7
13 Input 1 Output 1 Input Signal (IGBT Signal Required as Default)
14 Input 2 Output 2 Input Signal (IGBT Signal Required as Default)
15 Input 3 Output 3 Input Signal (IGBT Signal Required as Default)
16 Input 4 Output 4 Input Signal (IGBT Signal Required as Default)
17 Input 5 Output 5 Input Signal (IGBT Signal Required as Default)
18 KLINE Diagnostics for Internal Use
19 Input 11 Output 11 Input Signal (IGBT Signal Required as Default)
20 Input 10 Di Pump2 Input Signal / Output 10 Input Signal
21 Input 9 Di Pump1 Input Signal / Output 9 Input Signal
22 Input 8 Output 8 Input Signal (IGBT Signal Required as Default)
23 Input 7 Output 7 Input Signal (IGBT Signal Required as Default)
24 VBAT1 12V Supply for HS Outputs 1-6
25 HS1,2 High Side Injector + to Pair with Outputs 1,2 Low Side
26 PWRGND Ground – Must be Connected
27 HS3,4 High Side Injector + to Pair with Outputs 3,4 Low Side
28 HS5,6 High Side Injector + to Pair with Outputs 5,6 Low Side
29 Input 6 Output 6 Input Signal (IGBT Signal Required as Default)
30 Input 12 Output 12 Input Signal (IGBT Signal Required as Default)
31 HS11,12 High Side Injector + to Pair with Outputs 11,12 Low Side
32 HS9,10 DI Pump2 High Side / High Side Injector + to Pair with Outputs

9,10 Low Side
33| PWRGND| Ground – Must be Connected
34| HS7,8| High Side Injector + to Pair with Outputs 7,8 Low Side
35| VBAT2| 12V Supply for HS Outputs 7-12

Read More About This Manual & Download PDF: