Immax NEO Smart Zigbee Thermostatic Head
PRODUCT SPECIFICATIONS
Power supply: 2 x AA1.5 V, alkaline batteries
Temperature measurement accuracy: +-0.5°C
Sensor: NTC (10k)1%
Max. extension: 4.5 mm
Temperature setting range: 5~35°C -10~60°C (-10~60°F)
Size (mm):5389.5mm
Temperature display range: 1 ~ 70 °C
Thread size: M30 1.5
Protocol: Zigbee
Frequency: 2400MHz~2483.5MHz
Maximum RF output power: 10dBm – max 19dBm
Download the “Immax NEO PRO” app from Google Play and App Store or scan the attached QR code.
https://smartapp.tuya.com/immaxneosmart
Password to set advanced functions: 123456
- After the ZigBee gateway is configured, enter the gateway to add sub-devices,and wait for the actuator to be powered on and the system self-check is completed.
- long press and to active flashing access network connected mode .
- In the Immax NEO PRO app, confirm that the WiFi connection symbol flashes quickly and continue following the instructions in the app.
For information on setting up the Immax NEO PRO, please refer to the Smart Gateway User Guide.
DISPLAYS & BUTTONS
| Icon
---|---
A| Auto Mode; Manual mode Energy saving mode Low battery; Children lock;
Boost mode; Open Window function Comfort mode Auto mode period Holiday mode
B| Room temperature Time setting Zigbee connection status Set
temperature/Advanced options Valve status
Icons | Description |
---|---|
1. Short press to switch between Auto and Manual mode |
2. Long press to enter Advanced Settings
| 1. Short press to switch between Comfort Mode and ECO Energy Saving Mode
2. Long press for 3 seconds to display the valve open status
| 1. Long press within 3 seconds to start the BOOST function: the BOOST rapid
heating mode is started, a short press of any key will end this function and
return to the previous operating mode
2. Press the key for more than 3 seconds to activate the Lock/Unlock function
Rotation| 1. Clockwise, the value increases
2. Counterclockwise value decreases
INSTALLATION AND INITIAL COMMISSIONING
When the thermostatic head is switched on, all icons are displayed for 3
seconds.|
---|---
Setting the time: when the icon flashes press and rotate to set the desired
hour, then press again
and rotate to set the desired minute, another press and rotate to set the day
of the week. The last press will save your settings. Note: If you need to set
the time when the thermostatic head is operating normally, long press (more
than 3 seconds) to enter the Advanced Settings. Then press to select and short
press to enter the time setting. Then follow the instructions above.|
If the “Ad” icon appears, press the button to start the control system. When
“1” is displayed, this is the first step of self-testing. When “2” is
displayed, the head has entered the second phase of testing. If the check is
successful, the thermostatic head will return to normal operation. If an error
message appears after testing, correct the evaluated problem first and then
the head will return to normal operation.|
E1 Engine failure
E2 Sensor failure
Flashing icon indicates low battery
SPECIAL FEATURES
Holiday mode| Long press (more than 3 seconds) to enter Advanced Settings.
Then press to select Holiday mode. A short press will enter the temperature
setting option, another press will access the days setting. Rotate to set the
desired values and press again to save . Press to exit the holiday mode .
---|---
Open window function| Open window detection is disabled by default. If you
want to enable the feature, you can do so in Advanced Settings.
Comfort mode| Long press (more than 3 seconds) to enter Advanced Settings.
Then press to select and short press to proceed to Comfort Mode settings.
Rotate and then confirm to save the set values.
ECO energy saving
mode| Long press (more than 3 seconds) to enter Advanced Set- tings. Then
press to select and short press to proceed to the ECO Power Saving Mode
setting. Rotate and then confirm to save the set values.
SETTING THE AUTOMATIC MODE
Long press (more than 3 seconds) to enter Advanced Settings. Then press to select and short press to proceed to Auto mode setting. Short press to select which mode you want to set: 5 = 5+2 days, 6 = 6+1 days, or 7 = 7 separate days. Press to confirm the selected mode and then rotate to set the desired temperature, time and day. Press to save. If you do not press anything, the values are automatically saved in 10 seconds.
period | Default period | Default temperature |
---|---|---|
1 | 6:00 | 20°C |
2 | 8:00 | 15°C |
3 | 11:30 | 15°C |
4 | 12:30 | 15°C |
5 | 17:30 | 20°C |
6 | 22:00 | 15°C |
ADVANCED SETTINGS
Long press (more than 3 seconds) to enter Advanced Settings. Then press to select and short press to enter the Advanced settings. Press the icon to cycle through the functions and rotate to change the values for the functions. Press to save. If you do not press anything, the values are automatically saved in 10 seconds.
| Item| Parameter settings| default
---|---|---|---
1| Correction of measured temperature| -9+9°C (then the temperature with
this correction is displayed)| -1°C
2| Open window
function:value: temperature and time| 1: if displayed, the function is
disabled. Rotate to set the temperature by how much the temperature on the
sensor must drop to activate the function (temperature
setting range: 5-25°C).
2. detection time: 5-60 min (the time it takes for the temperature to drop
for the function to be activated) Press to save changes.| —
3| Automatic lockout if no one does anything to the thermostatic head for 10
minutes| 0: off
1: on| 0
4| Minimum temperature setting| 1-15°C| 5°C
5| Maximum temperature setting| 16-70°C| 35°C
6| Duration of BOOST mode| 100s-900s Steps 100 seconds| 300
7| Start/stop setting of the difference from the desired temperature| 0,5 –
1,5| 1
8| Valve control type| 0: PID
1: on/off| 0
9| Reset| Set the display to 88 and then clockwise or counterclockwise to
00. Press the button to reset the thermostatic head.|
10| Valve type| 0: easy to close
1: hard to close (higher energy consumption)| 0
VALVE CONTROL TYPE
0: The thermostatic head controls the valve based on a learning algorithm that
works with the thermodynamic properties of the object (cooling rate, etc.)
1: The valve behaviour is set as follows:
- If the desired room temperature is 2 degrees higher than the actual temperature measured by the thermostatic head, the valve opens 100%.
- If the desired room temperature is 1 degree higher than the actual temperature measured by the thermostatic head, the valve opens at 75%.
- if the desired room temperature is 0.5 degrees higher than the actual temperature measured by the thermostatic head, the valve opens to 50%.
- if the desired room temperature is 1 degree lower than the actual temperature measured by the thermostatic head, the valve opens to 25%.
- if the desired room temperature is 2 degrees lower than the actual temperature measured by the thermostatic head, it closes the valve (0%).
CONNECTOR COMPATIBILITY
SAFETY INFORMATION
WARNING: Keep out of reach of children. This product contains small parts that
may may cause suffocation or injury if swallowed.
WARNING: Each battery has the potential to leak harmful chemicals that can
damage skin, clothing or the area where the battery is stored. To avoid the
risk of injury, do not allow any substance from battery come into contact with
your eyes or skin. Any battery can rupture or even explode if exposed to fire
or other forms of excessive heat. Use caution when handling batteries. To
reduce the risk or injury caused by improper handling of batteries, take the
following precautions:
- Do not use different brands and types of batteries in the same device.
- When replacing batteries, always replace all batteries in the device.
- Do not use rechargeable or reusable batteries.
- Do not allow children to install batteries without supervision.
- Follow the battery manufacturer’s instructions for proper battery handling and disposal.
NOTE: The product and batteries should be disposed of at a recycling
center. Do not dispose of with regular household waste.
WARNING: To ensure safe use of the product, wires must be routed at the
point of installation according to Installation must only be carried out by a
person with appropriate electrical certification.
During installation or when a fault is detected, the supply cable must always
be disconnected from the socket (in the case of direct connection, the
relevant circuit breaker must be switched off). Improper installation can lead
to product damage and injury.
WARNING: Do not disassemble the product, possibility of electric shock.
WARNING: Use only the original power adapter supplied with the product.
Do not put the device into operation if the power cord shows signs of damage.
WARNING: Follow the instructions in the instructions in the enclosed
manual.
MAINTENANCE
Protect the equipment from contamination and dirt. Wipe the unit with a soft
cloth, do not use rough or coarse material.
DO NOT use solvents or other aggressive cleaners or chemicals.
A Declaration of Conformity has been issued for this product, for more
information please visit www.immax.cz
Manufacturer and importer:
IMMAX, Pohoří 703, 742 85 Vřesina, EU | www.immax.cz
Made in China
Documents / Resources
|
Immax Neo Lite Smart Thermostatic Head
Zigbee
[pdf] User Manual
Smart Thermostatic Head Zigbee, Smart Thermostatic, Head Zigbee, Zigbee
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>