TECNOPLASTIC TAURUS Float Switch Instructions

June 9, 2024
TECNOPLASTIC

TAURUS Float Switch
Instructions

TAURUS Mod.01 H07 RN-F 3G1 +50°C +122°F 20m / 65,6ft
H07 RN8-F 3G1 +50°C +122°F 20m / 65,6ft
H07 RN-F 3G1 OIL RES. +50°C +122°F 20m / 65,6ft
Mod.02 H05 RN-F 3X1![Icon](https://manuals.plus/wp-
content/uploads/2022/05/Screenshot_3-305.png) +50°C +122°F 20m / 65,6ft
Mod.03 H07 RN-F 3X1![Icon](https://manuals.plus/wp-
content/uploads/2022/05/Screenshot_3-305.png) +50°C +122°F 20m / 65,6ft

TAURUS| Drink| ACS + AD8 3X1Icon| +40°C +104°F| 20m / 65,6ft
---|---|---|---|---

TAURUS| Fep| FFR105OPR5F
4G0.75| +80°C +176°F| 20m / 65,6ft
---|---|---|---|---
Shift| Shift 4G1,5| +80°C +176°F| 20m / 65,6ft
Purr| PUR – FFR105OP
4G0,75| +80°C +176°F| 20m / 65,6ft

NOTES: DO NOT TAMPER WITH THE FLOAT SWITCH. THE NON RESPECT OF THE FOLLOWING POINTS WILL AUTOMATICALY CAUSE THE CANCELLATION OF THE WARANTY OF THE PRODUCT

  • Before any operation on the float remember to disconnect the power supply from the main power.
  • Check that the maximum motor power does not exceed the float’s electrical values.
  •  In case of cable damage by the final user or installer, the float must be replaced.
  • Do not make any joint on the cable of the float switch, as immersion of such joints could cause short circuits or electrical shocks.

USE:

Unlike normal floats, the level regulator is used in pairs of two of the same type to regulate water levels to a certain height: one regulates the minimum level and the other regulates the maximum level. A third and fourth regulator can also be used for minimum and maximum alarm respectively. To avoid damaging the cable, we recommend the Fixing Kit (Fig.3)

TECHNICAL FEATURES:

  • Protection Grade: IP 68
  • Specific weight: 0,95 – 1,05 kg/dm³
  • Features of automatic action: 1B (micro-disconnections in operation)
  • Pollution Degree: 2

TERMINAL CONNECTIONS:

The upstream circuit must protect the electric wires from the overcurrent. WARNING: lack of protection shall null and void the warrany in the event the float breaks.

  • Mod.01: single function SPST – only emptying or only filling (Fig.1). The grounding wire is always yellow and green.
  • Mod.02 – Mod.03 – Drink – Fen – Shift – Purr: double function SPDT (the fattier can choose the emptying Fig.2 or filling Fig.3 when installing):

Emptying: (Fig.2) when black and brown wires are used, the circuit opens when float is down and closes when the float is up.
Note: the blue/grey wire must be insulated.
Filling: (Fig.3) when black and blue/grey wires are used, the circuit closes when float is down and opens when the float is up.
Note: the brown wire must be insulated.

EC DECLARATION OF CONFORMITY
This is to declare that the product complies with the following Harmonized Standards and Directives

Directives harmonized standards
Low voltage Directive 2014/35/EU

EN 60730-1; EN 60730-2-15;
EN 61000-3-2; EN 61000-3-3; EN 61000-4-4;
EN 61000-4-5; EN 61000-4-6; EN 61000-4-8;
EN 61000-4-11.
Electromagnetic Compatibility Directive| 2014/30/EU

The person authorized to compile the Technical File is Mr. Guerrini Castaldo at TECNOPLASTIC Seral.

TECNOPLASTIC Seral. Via Calabria, 3-5 – 35020 – Sayonara – Padova – ITALY
Tel: +39 049 8790775 – Fax: +39 049 644773 – www.tecnoplastic.com
REV. January 2022
Type Approved Safety Regular Production Surveillance
www.tuv.com
ID 1111220658