TECNOPLASTIC TAURUS Float Switch Instructions
- June 9, 2024
- TECNOPLASTIC
Table of Contents
TAURUS Float Switch
Instructions
TAURUS | Mod.01 | H07 RN-F 3G1 | +50°C +122°F | 20m / 65,6ft |
---|---|---|---|---|
H07 RN8-F 3G1 | +50°C +122°F | 20m / 65,6ft | ||
H07 RN-F 3G1 OIL RES. | +50°C +122°F | 20m / 65,6ft | ||
Mod.02 | H05 RN-F 3X1 | +50°C +122°F | 20m / 65,6ft | ||
Mod.03 | H07 RN-F 3X1 | +50°C +122°F | 20m / 65,6ft |
TAURUS| Drink| ACS + AD8 3X1| +40°C +104°F| 20m / 65,6ft
---|---|---|---|---
TAURUS| Fep| FFR105OPR5F
4G0.75| +80°C +176°F| 20m / 65,6ft
---|---|---|---|---
Shift| Shift 4G1,5| +80°C +176°F| 20m / 65,6ft
Purr| PUR – FFR105OP
4G0,75| +80°C +176°F| 20m / 65,6ft
NOTES: DO NOT TAMPER WITH THE FLOAT SWITCH. THE NON RESPECT OF THE FOLLOWING POINTS WILL AUTOMATICALY CAUSE THE CANCELLATION OF THE WARANTY OF THE PRODUCT
- Before any operation on the float remember to disconnect the power supply from the main power.
- Check that the maximum motor power does not exceed the float’s electrical values.
- In case of cable damage by the final user or installer, the float must be replaced.
- Do not make any joint on the cable of the float switch, as immersion of such joints could cause short circuits or electrical shocks.
USE:
Unlike normal floats, the level regulator is used in pairs of two of the same type to regulate water levels to a certain height: one regulates the minimum level and the other regulates the maximum level. A third and fourth regulator can also be used for minimum and maximum alarm respectively. To avoid damaging the cable, we recommend the Fixing Kit (Fig.3)
TECHNICAL FEATURES:
- Protection Grade: IP 68
- Specific weight: 0,95 – 1,05 kg/dm³
- Features of automatic action: 1B (micro-disconnections in operation)
- Pollution Degree: 2
TERMINAL CONNECTIONS:
The upstream circuit must protect the electric wires from the overcurrent. WARNING: lack of protection shall null and void the warrany in the event the float breaks.
- Mod.01: single function SPST – only emptying or only filling (Fig.1). The grounding wire is always yellow and green.
- Mod.02 – Mod.03 – Drink – Fen – Shift – Purr: double function SPDT (the fattier can choose the emptying Fig.2 or filling Fig.3 when installing):
Emptying: (Fig.2) when black and brown wires are used, the circuit opens
when float is down and closes when the float is up.
Note: the blue/grey wire must be insulated.
Filling: (Fig.3) when black and blue/grey wires are used, the circuit
closes when float is down and opens when the float is up.
Note: the brown wire must be insulated.
EC DECLARATION OF CONFORMITY
This is to declare that the product complies with the following Harmonized
Standards and Directives
Directives | harmonized standards |
---|---|
Low voltage Directive | 2014/35/EU |
EN 60730-1; EN 60730-2-15;
EN 61000-3-2; EN 61000-3-3; EN 61000-4-4;
EN 61000-4-5; EN 61000-4-6; EN 61000-4-8;
EN 61000-4-11.
Electromagnetic Compatibility Directive| 2014/30/EU
The person authorized to compile the Technical File is Mr. Guerrini Castaldo at TECNOPLASTIC Seral.
TECNOPLASTIC Seral. Via Calabria, 3-5 – 35020 – Sayonara – Padova – ITALY
Tel: +39 049 8790775 – Fax: +39 049 644773 –
www.tecnoplastic.com
REV. January 2022
Type Approved Safety Regular Production Surveillance
www.tuv.com
ID 1111220658