HomeControl STI-6400 Series Exit Stopper Installation Guide
- June 9, 2024
- HomeControl
Table of Contents
Exit Stopper ® Quick Install
STI-6400 Series Rely on STI ®
STI-6400 Series Exit Stopper
SET UP
- Key in OFF position
- Remove security screw with provided wrench
- Remove cover from base, push on lock to separate
- Choose setting – refer to switch table, default settings shown side 2
- Unwrap battery and connect
- Terminal block (remote power and relay options) – refer to full install online for wiring connections
- Test – place magnet next to reed, turn key switch on, separate magnet from reed
- Apply language label if desired
MOUNTING
- Place reed at desired location (top, right, bottom or left)
- Position base. Mark and drill four (4) holes 1” (25mm) deep. Using plastic anchor, drill 3/16” (4.5mm). Install into wood or steel: drill 9/64” (3.5mm). Mount using (4) M4 x 25mm screws. MOUNTING HOLES MOUNTING HOLES
- Install reed magnet, mark with pencil, drill, install using plastic anchor, drill 3/16” (4.5mm). Install into wood or steel: drill 1/8” (3mm). Mount with (2) M3.5 x 32mm screws.
- Test, turn key on, open door
- Replace cover, snap lid from top, secure with security screw
SWITCH SETTINGS Arming – immediate | 1OFF* | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
---|---|---|---|---|---|---|---|---|
Arming – 15 second delay | ON | |||||||
inp – immediate | OFF’ | |||||||
Tnp – 15 second delay | ON | |||||||
Shut-ott based on duration (switches 4 & 5) | OFF* | |||||||
Shut-off approx. 3 sec. after door closes | ON | |||||||
Duration – 30 second alarm | OFF* | OFF’ | ||||||
Duration -180 second alarm | OFF | ON | ||||||
Duration – continuous alarm | ON | OFF | ||||||
Duration – 30 second annunciator mode | ON | ON | ||||||
Low battery detection on – Turn switch off | OFF’ | |||||||
Low battery detection off – Turn switch on | ON | |||||||
Volume – high | ON’ | |||||||
Volume – low | OFF | |||||||
Turn switch on | OFF’ |
Dry contact relay function OFF
Dry contact relay function ON| | | | | | | | ON
*default
NOTE: Disconnect all power sources before changing switch settings.
Warranty
Three year warranty or a one year limited warranty (from date of purchase) on
most products. See website for details.
Electronic warranty form at www.sti-usa.com/wc14.
WARNING: This product can expose you to chemicals including
Dichloromethane, which is known to the State of California to cause cancer,
and Bisphenol A (BPA), which is known to the State of California to cause
birth defects or other reproductive harm.
For more information go to
www.P65Warnings.ca.gov.
https://www.sti-usa.com/series/sti-exit-stopper/
Subject to change without notice.
2306 Airport Rd • Waterford, MI 48327, USA
Phone: 248-673-9898 • info@sti-
usa.com • www.sti-usa.com
Taylor House • 34 Sherwood Road • Bromsgrove, Worcestershire • B60 3DR •
England
Tel: +44 (0)1527 520 999 • info@sti-emea.com •
www.sti-emea.com
Unit 7A • Lockhead Avenue • Airport Business Park • Waterford • X91 HWF2 •
Ireland
info@sti-emea.com • www.sti-
emea.com
https://www.sti-emea.com/series/exit-stopper/
6400 QUICK INSTALL
March2021
Documents / Resources
|
HomeControl STI-6400 Series Exit
Stopper
[pdf] Installation Guide
STI-6400 Series Exit Stopper, STI-6400 Series, Exit Stopper, Stopper
---|---
References
- emea.com
- USA Location information - USA.com
- P65Warnings.ca.gov
- Home - STI EMEA
- Security & Safety Device Protection | Safety Technology International
- Warranty & Returns - STI US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>