When using electrical appliances, these instructions and warnings should always be followed to reduce the risk of fire, electrical shock and injury to persons: READ AND SAVE ALL WARNINGS AND INSTRUCTIONS BEFORE USING THIS UNIT.

WARNING

  • DO NOT use this unit to ventilate areas where flammable liquids or vapors are used, stored or are present, including paints, gasoline, varnishes, floor refinishing products or solvents. ALWAYS read and follow all warnings and instructions on the containers for these products!
  • DO NOT use the unit near combustible gas, or hot air as unit could melt and cause a fire or electrical hazard.
  • ALWAYS be sure the plug fits tightly into the outlet and that it fits tightly into the unit. When plugs fit loosely into outlets, they may slip partially out of the outlet and create a poor connection. This may cause outlets to overheat and create a potential fire hazard. Outlets in this condition should be replaced by a qualified electrician.
  • DO NOT take the unit apart or repair it unless you are qualified to do so. NEVER repair or service unit while unit is plugged in.
  • ALWAYS unplug the power cord when cleaning or moving the unit. DO NOT use the Power switch as the sole means of disconnecting power. NEVER leave children unattended when the unit is on or plugged in. ALWAYS turn off and unplug the Unit when not in use.
  • Store the unit in a clean, dry environment. DO NOT store outdoors or allow water inside the unit’s motor. If the motor becomes wet, allow it to thoroughly dry before use.
  • The unit should never be operated near standing water as it will create a risk of serious injury from electrical shock. Never plug in or unplug the unit with wet hands or while standing in water. Handle unit with care to avoid causing damage or injury.
  • BE CERTAIN that the power source for the Unit is 120V AC, 60Hz. DO NOT plug the Unit into 240V or another power source.
  • The power cord is equipped with a three-prong, grounded plug that must be inserted into a grounded receptacle. Under no circumstances must the grounding prong be cut off the plug. WARNING: Do not use a three-prong to two-prong adapter.
  • Where a two-prong wall receptacle is encountered, it must be replaced with a properly grounded three-prong receptacle installed in accordance with the National Electrical Code (NEC) and all applicable local codes and ordinances. This work must be done only by a qualified electrician, using copper wire only.
  • USE OF A THREE-PRONG TO TWO-PRONG ADAPTER IS NOT PERMITTED. IMPROPER CONNECTION MAY CREATE THE RISK OF ELECTRICAL SHOCK. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.

CAUTION

  • AVOID the use of extension cords, power strips, power taps, outlet style air fresheners or another cord connected device, as these devices may overheat and cause a fire hazard.
  • DO NOT route power cord under rugs, carpets, runners or furniture. This may damage the cord or cause it to overheat creating a fire hazard.
  • ALWAYS place the Unit on a stable, flat, level surface while in operation to prevent the Unit from overturning.
  • NEVER insert or allow fingers or objects to enter grill openings while Unit is in operation or injury and/or damage to the Unit may occur.
  • DO NOT block, cover or obstruct air flow to or from the Unit while in operation.
  • DO NOT use this unit outdoors or in standing water. Keep motor and wiring dry.
  • DO NOT run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it could be tripped over.
  • NEVER use a single extension cord to operate more than one Unit or other electrical device.
  • DO NOT operate this product with a damaged power cord plug. If the supply cord is damaged it must be replaced by qualified personnel or other similar qualified persons in order to avoid hazard.
  • The use of attachments or accessories not recommended or sold by the product distributor may cause injury to persons or damage to property.
  • This appliance is NOT intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • DO NOT leave children unsupervised with the appliance.
  • DO NOT use this Unit if it has been damaged or is not functioning properly.
  • THIS Unit DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547-7 (2008). This Unit is not suitable for use in agricultural facilities including areas where livestock, poultry or other animals are confined. Please refer to National Electric Code (NEC) Article 547-7 (2008), or applicable state or local codes or standards relating to electrical requirements for agricultural buildings.
  • THIS Unit DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008). This Unit is not suitable for use in hazardous locations. Please refer to National Electric Code (NEC) Article 500 or applicable state or local codes or standards relating to electrical requirements for hazardous locations.

MAINTENANCE

WARNING: To reduce the risk of electrical shock and fire please observe the following instructions. Cleaning the Unit regularly will help to maintain its efficiency.

  • Always unplug the cord before moving, servicing or cleaning.
  • NEVER place the unit in or near standing water. DO NOT IMMERSE UNIT IN WATER.
  • Clean the unit only with a vacuum equipped with a brush attachment; the vacuum will remove the lint and dirt from the surface of the unit.
  • Vacuum intake grills and filter every two weeks; this will help to maintain optimum performance.
  • Clean the body of the unit with a soft cloth only.
  • NEVER use ALCOHOL or SOLVENTS such as gasoline, benzene, paint thinner, or other harsh cleaners.

SAVE THESE INSTRUCTIONS

The DH76 Dehumidifier reduces humidity in enclosed structural environments by removing water vapor from the air. With proper use, the DH76 can help to dry out damp structural materials, insulation, contents, and maintain a healthy level of humidity. Using the DH76 may also prevent secondary damage caused by high humidity.

SETUP DRAIN HOSE

The DH76 condensation pump connects to a plastic drainage hose. This hose is equipped with a quick- connect fitting for quick attachment to the provided 25 ft. (7.5 m) drain hose. Unwrap the entire hose and place the unattached end in a sink, drain, bucket or outdoors – anywhere that water can drain out safely. If you use a bucket or other container for water collection, check it regularly to prevent overflows.

NOTICE: Uncoil and straighten the entire drain hose. Do not leave any part of the hose coiled and do not place the end of the hose higher than 17 ft. (5 m) above the bottom of the unit. Also check for kinks or other obstructions that might restrict the flow of water. Obstructions may cause a water backup and result in overflows.

DISPLAY MODES

When unit is first plugged in to AC power, the control panel display will briefly cycle through a series of readouts. This is part of the unit’s self- diagnosis procedure and no user intervention is required.

NOTICE: The DH76 must be plugged into a 120VAC/ 60Hz outlet rated for at least 10 amps. Always plug the cord firmly into the unit first, and then plug the other end into a suitable wall outlet.

CONTROL PANEL

BlueDri-DH76-Portable-Commercial-Dehumidifier-FIG-1

IN| Shows Temp & humidity of the inlet| OUT| Shows Temp & humidity of the outlet
---|---|---|---
Cool| Shows Temp @ condenser| COMP A| Shows Amperage Draw of the compressor
Runtime| Shows Job hours & life hours| STATE| Shows the state of the dehumidifier

POWER Press and release to turn unit on or off.
MENU Press to select next item in menu. Menu item will show in display.
SET Press to toggle or select values in menu displayed.
PUMP Press and release to start purge.

HUMIDISTAT SETTING

The default operating mode keeps the dehumidifier running at its maximum capacity. This is ideal for most restoration application. To control humidity at a specific level, described below:

  1. Press MENU once, and screen shows as FIG A, Press SET once so the screen shows as FIG B, with an arrow pointing at the line Moisture line.
  2. Press SET to adjust the target Moisture, Each press of the button increases the setting by 5% increments, cycling through 90%RH and starting again at 0%RH.
  3. Press MENU once to confirm you %RH, and then two more times to return to the main screen.

TEMPERATURE SETTING

To change unit of temperature, described below:

  1. Press MENU once, and screen shows as FIG C, Press SET once, and then MENU once, so the screen shows as FIG D, with an arrow pointing at the Temperature line.
  2. Press SET to select Fahrenheit or Centigrade.

AFTER THE JOB

To reduce the possibility of drips when moving the unit, follow these additional steps to ensure that all water is removed from the unit.

NOTICE: To ensure the condensate tank empties completely while purging, make sure the unit is positioned horizontally on a flat surface.

  1. Gently rock the machine to ensure any water remaining on interior surfaces falls into the sump area.
  2. Press the PUMP key. When the purge cycle is complete, turn the unit off.
  3. Remove the external drain hose, drain it carefully, coil it and secure it with one of the Velcro straps provided on the side of the unit.
  4. Unplug power cord from power supply and from base of the machine, coil neatly, coil it and secure it with one of the Velcro straps provided on the side of the unit.

TRANSPORTATION AND STORAGE

NOTICE: Handle the unit carefully. Do not drop, throw, or place the unit where it could fall. Rough treatment can damage this equipment and may create a hazardous condition or void warranty.

  • Do not expose the control panel to moisture, snow or rain.
  • Protect from freezing.
  • Store and transport securely, and in the upright position, to avoid damaging of internal parts.
  • Secure during transport to prevent sliding and possible injury to vehicle occupants.

MAINTENANCE SCHEDULE

WARNING:  ELECTRIC SHOCK HAZARD. Unplug unit before cleaning or servicing.

WARNING: Risk of dust and contaminants exposure. Use of respirator mask and gloves is recommended. If unit has been exposed to potentially dangerous contaminant, clean thoroughly and sanitize before reuse.

NOTICE: The unit is fitted with sensitive electronic sensors. Protect the sensors and their lead wires from damage and do not expose them to water or cleaning solution.

Before Each Use: Inspect the electrical cord for damage. Look for fraying, cuts, etc. Replace the cord if you find any damage. Inspect, vacuum or replace filter. Monthly Inspect coils. Clean when dust accumulation is visible. In normal use, dust can accumulate and can restrict airflow, reducing performance and causing the unit to overheat. Use a vacuum cleaner with a brush tool and a soft cloth to remove any debris. Take care not to damage any interior components. To maintain appearance, wipe interior surfaces with a damp cloth.

Clean Pump Check Valve and Basin: If the unit displays the message “STATE PUMP”, which means the pump may be blocked, check valve and pump basin may need to be cleaned. This operation must be performed by a qualified technician. Unplug the dehumidifier before

Cleaning:  Remove grills and cover. Remove screws from pump base and lift out pump. Wipe out pump basin with a damp cloth. Inspect the pump base for build-up of debris and clean if needed. Unthread barbed fitting with check valve and rinse fitting and check valve with clean water. Reinstall check valve into barbed fitting and install the barbed fitting into pump. Do not over-tighten. Reinstall pump in base. Reinstall cover and grills.

Clean Coils: With the cover removed, inspect both coils. If excessive dust and debris is present, vacuum thoroughly and/or clean with coil cleaner. This operation must be performed by a qualified technician.

MODEL DH76
Power Input 120 Volts, 60Hz
Compressor Power 3/4HP @Aham
Motor Rating: 65W
Current: 6.5 amps
Water Removal 150 Pints/Day @ 90F/90% 76 Pints/Day @ 80F/60%
CFM: 150-190
Weight 65 lbs
Size 22.6x14x20inch
Certifications: cULus

SYSTEM MESSAGES

BlueDri-DH76-Portable-Commercial-Dehumidifier-
FIG-4

The DH76 control system constantly monitors internal operating conditions. If the system detects a problem, the state row will change to an ERROR message instead of RUN/OFF. If the display shows an ERROR message, first unplug the unit and then plug it back in. This will usually reset the electronics, and the unit will begin operating normally. If the ERROR message reappears, refer to the explanation and solution shown below.

Control Panel Explanation and Solution Message     Meaning

STATE COMP| Compressor may not work, Check compressor cable for proper connection. If error persists, contact service.
STATE: MOIS| Check inlet Temp/RH sensor for proper connection. If error persists, contact service.
STATE: TEMP 1| Check inlet Temp/RH sensor for proper connection. If error persists, contact service.
STATE: TEMP 2| Check outlet Temp/RH sensor for proper connection. If error persists, contact service.
STATE: PUMP| Check for obstructions in drain hose. If clogged, remove hose from unit and blow hose out with compressed air. Inspect and clean the pump check valve and pump basin.

TROUBLESHOOTING

Problem Possible Cause Possible Solution
Water drips out when moving unit Unit was unplugged before purging was
complete. Purge unit by pressing the pump button before moving. See “AFTER

THE JOB”
Unit does not operate|

  • Unit not switched on.
  • No power to machine.

|

  • Switch unit on.
  • Plug in unit; check that the power cord con- nections at the wall outlets and base of the unit are inserted completely and secure.

Unit operating, but room not dry|

  • Not enough time to dry. Poor air movement in room.
  • **** Excessive moist air infiltration.

|

  •  Allow more time for drying. Increase air movement with air movers.
  • Seal off area to reduce infiltration.

Unit collects too little water|

  • Room air is dry.
  • Room temperature is too low.
  • Coils are clogged.
  • Filter is clogged.

|

  • Confirm humidity level with hygrometer.
  • Increase room temperature.
  • Check coils. Clean as necessary.
  • Check filter. Clean or replace as necessary.

Unit stop working after few hours| The set humidity is less than the environment humidity.| Decrease the set humidity according to the HUMIDISTAT SETTING process.

Unit Assembly

BlueDri-DH76-Portable-Commercial-Dehumidifier-FIG-5

Ref Part Number Description Qty Req
1 DH7601 Inlet Grill 1
2 DH7602 Prefilter 1
3 DH7603 Water Pump 1
4 DH7604 Water Level Switch 1
5 DH7605 Evaporator Coil 1
6 DH7606 Compressor 1
7 DH7607 Condenser Coil 1
8 DH7608 Humidity Sensor 1
9 DH7609 Top Housing 1
10 DH7610 Control Panel 1
11 DH7611 Outlet Nozzle 1
12 DH7612 Outlet Grill 1
13 DH7613 Fan 1
14 DH7614 Electronics Housing 1
15 DH7615 Bottom Housing 1
16 DH7616 Electrical Cord 1
17 DH7617 Water Tubing 1

LIMITED MANUFACTURER’S WARRANTY

Intertex, LLC (the “manufacturer) warrants that this product (the “Product) sold to the original user (the “User) shall be free from defects in material and workmanship as follows:

This limited warranty shall extend for one (1) year for the entire Product and five (5) years on the sealed system, which shall include only the compressor, evaporator, and condenser. The limited warranty shall include parts and labor to repair the Product or replacement of the Product, at the sole discretion of the manufacturer. If this limited warranty is exercised in the first fifteen (15) days following purchase, in addition to the remedies listed above, the manufacturer shall be responsible for the shipping costs of providing a replacement Product to the User. The limited warranty following the first fifteen (15) days shall not include shipping costs. The User shall provide proof of purchase date to establish coverage under this limited warranty. In the event the User is unable to provide such proof, the manufacturer will establish the purchase date as thirty (30) days following the date of manufacture for the Product.

His limited warranty shall not cover

  1. Useful fiter life and replacement filters.
  2. Damage due to failure to perform normal maintenance as outlined in the Instruction Manual.
  3. Failures of the Product due to voltage conditions, blown fuses, open circuit breakers, or any other damages due to the inadequacy or interruption of electrical services
  4. Damage due to misapplication, abuse, neglect, unauthorized alteration, improper servicing or operation, including operation outside the voltage and frequency limitations as stated on the unit rating plate, or failure to follow warnings as stated on the Product and in the Instruction Manual.
  5. Damage due to flooding., fires, lightning, freezing of residual water, corrosive environment, or other conditions beyond the control of the manufacturer.
  6. Damage due to use of replacement parts not supplied by the manufacturer.
  7. Shipping damage.

Further, the manufacturer does not warrant that the Product is merchantable or fit for any particular purpose. All other warranties, guaranties, or representations, express or implied, by operation of law or otherwise, are expressly disclaimed. Returned Product for limited warranty service which is found by the manufacturer to be free from defect and to conform to specifications shall be held for the User’s shipping instructions and payment, which shall be funished promptly upon request, but no later than thirty (30) days following the date of return. The manufacturer shall not be liable under any circumstances for special, contingent, incidental or consequential damages, losses, damages, or expenses directly or indirectly arising from the use of the Product, including without limitation, warehousing, labor, handling and service charges, die, equipment, or machine breakage, lost profits or loss of good will.

Any replacement parts supplied under this limited warranty will be warranted for the balance of the Product’s limited warranty. For warranty information and assistance contact B-Air at 877.800.2247 or email [email protected]/[email protected]

CUSTOMER SERVICE

Our Customer Service team is available to assist you with product and service questions.
Please have your model number available.
Customer Service Dept., 820 Lincoln Ave., West Chester, PA 19380
(Please do not send the product to this location) www.b-air.com

Manual printed in China

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BlueDri User Manuals

Related Manuals