Introduction
Congratulations on your purchase of the Triplett IRTC400 Thermal Imaging Camera. This instrument is useful in many applications such as preventative maintenance, troubleshooting of electrical and HVAC systems, mechanical breakdowns, water leaks and moisture buildup, heat loss from missing insulation and faulty windows/doors, automotive repair, and other places to find leaks and hot spots. With proper care, the instrument will last for many years of accuracy and service.
Features
- 2.4” (61mm) focus-free, color TFT display with 320 x 240 resolution
- Center spot and high/low-temperature tracking on image
- Audible and visual user programmable high/low-temperature alarms
- 4-bution easy-to-use menu
- Real-time clock/calendar
- Image Gallery
- Built-in LED work light
- Auto power off with disable
- USB interface for transferring images (.bmp) and recharging
- Includes 3.7V rechargeable Lithium-Ion battery, USB cable, software, and 32G MicroSD card
Safety
International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. Cautions o Improper use can damage the meter. Please read and understand all of the information provided in this User Guide and other included documentation before use. o Use extreme caution when the laser pointers are on. o Do not point the beam toward anyone’s eye or allow the beam to strike the eye from a reflective surface. o Do not use the laser near explosive gases or in other potentially explosive areas. o Refer to the CAUTION statement label (shown below) for critical safety information.
Meter Description
- Upper Housing
- Interface Protective Cover
- Lower Housing
- USB Type-C Interface Connector
- SD Card Slot
- Tripod Mount
- Laser Emission Window
- LED Light
- Infrared Camera Lens
- Trigger/Image Capture
- LCD Display
- OK Button
- Up Button
- Power/Back Button
- Down Button
Display Indicators and Icons
- Display size: 2.4″ (495mmx377mm)
- Display resolution: 320 (vertical) x 240 (horizontal)
- Center Point Temperature
- CenterPoint
- Low-Temperature Point
- Date and Time
- Battery Status
- Temperature Bar
- High-Temperature Point
Operation
Power On/Off
When the thermal imager is not turned on, long press the power button for 3s
to power on. When the thermal imager is in the suspend state, short press the
power button for 1 s to power on. When the thermal imager is turned on, short
press the power button for 1s to enter the suspend state. Long press the power
button for 8s,
Menu
Short press the OK button to enter the menu interface. Short press the Back
button to return to the upper menu. Short press the trigger to directly return
to the main interface of the thermal imager.
Image View
In the menu, select Image View, and then short press the OK button to enter
the image viewing interface. Press the Up/Down button to select an image.
Press the OK button twice to view the Picture Info or Delete images.
Temperature Mark
In the menu, short press the Up/Down button to select Temper Mark, and then short press the OK button to enter the temperature mark interface. Center Point Hi/Lo Point Palette/Date & Time can be set in this interface. For example, select Center Point, and then press the OK button to turn on/off this function.
HI/LO Alert
In the menu, short press the Up/Down button to select HI/LO Alert, and then
short press the OK button to enter the alert setting interface. Temper Alert,
Buzzer, HI Alert and LO Alert can be set in this interface.
LED light
In the menu, short press the Up/Down button to select Hand Light, and then
short press the OK button to turn on/off the flashlight.
Palette
In the menu, short press the Up/Down button to select Palette, and then short
press the OK button to enter the palette selection interface. Short press the
Up/Down button to step through six palettes: Rainbow, Iron, White Hot, Black
Hot, Rainbow HC, Lava, and short press the OK button to confirm the selected
palette.
Temperature Unit
In the menu, short press the Up/Down button to select Setting, and then short
press the OK button to enter the submenu. In the submenu, short press the
Up/Down button to select Temper Unit, and short press the OK button to switch
between °C/°F.
Measured Parameters
In the menu, short press the Up/Down button to select a setting, and then
short press the OK button to enter the submenu. In the submenu, short press
the UP/Down button to select Emissivity or Temperature Compensation, and short
press the OK button for settings.
Laser
In the menu, short press the Up/Down button to select Setting, and then short
press the OK button to enter the submenu. In the submenu, short press the Up/
Down button to select Laser, and short press the OK button to turn on/off the
laser.
Time & Date
In the menu, short press the Up/Down button to select Setting, and then short
press the OK button to enter the submenu. In the submenu, short press the Up/
Down button to select Time & Date, and short press the OK button to enter the
setting interface. The Time Format can switch between 12H and 24H. Press the
Up/Down button to adjust the value of time and date, and short press the OK
button to confirm.
Brightness
In the menu, short press the Up/Down button to select Setting, and then short
press the OK button to enter the submenu. In the submenu, short press the Up/
Down button to select Brightness, and short press the OK button to enter the
setting interface. The brightness can be Low, Middle, or High
Auto Power Off
In the menu, short press the Up/Down button to select Setting, and then short
press the OK button to enter the submenu. In the submenu, short press the Up/
Down button to select Auto Power Off, and short press the OK button to enter
the setting interface. In this interface, users can set the auto power off
time (5/ 10/30min) or turn off the auto power off function.
Auto Save
In the menu, short press the Up/Down button to select Setting, and then short
press the OK button to enter the submenu. In the submenu, short press the Up/
Down button to select Auto Save. Short press the OK button to turn on/off the
auto-save function.
Format SD
In the menu, short press the Up/Down button to select Setting, and then short
press the OK button to enter the submenu. In the submenu, short press the Up/
Down button to select Format SD and short press the OK button to enter the
setting interface. Press the OK button and select Yes or No
Factory Reset
In the menu, short press the Up/Down button to select Setting, and then short
press the OK button to enter the submenu. In the submenu, short press the Up/
Down button
to select Factory Reset and short press the OK button to enter the setting
interface. Press the OK button and select Yes or No. In this picture, it will
jump back to the main interface when you touch the screen.
USB Communication and PC Analysis Software
- Please refer to the instructions to download and install the PC software.
- Connect the USB data cable to the computer. Users can view images and analyze data via the PC software.
- To use the PC software correctly, please read the Software User Manual.
- During USB communication, do not directly unplug the USB cable. If users want to disconnect the device when it has been successfully connected to the computer, they can select Remove Device in the lower right corner of the computer.
Maintenance
Use a wet cloth or weak soap solution to clean the outer shell of the device. Do not use abrasives, isopropyl alcohol, or solvents to clean the outer shell, lens, or window.
Specifications
Sensor | Uncooled infrared focal plane thermal imaging sensor |
---|---|
Pixel size | 17pm |
Infrared spectrum bandwidth | 8-14pm |
Thermal imaging pixels | 10800 (120*90) |
Thermal imaging sensitivity | 560mK |
Field of view (FOV) | 50°(H) x 38°(V) |
Spatial resolution (IFOV) | 73 mrad |
Rate | ≤25Hz |
Minimum imaging distance | 0.1m |
Focus | Focus-free |
Temperature range | -20°C — 400°C |
Accuracy | ±2°C or ±2%, whichever is greater |
(-10°C — 400°C room temperature 25°C)
Measurement units| °C/°F
Resolution| 0.1°C
Emissivity| 0.95 (default) 0.01-1.00
Temperature display| Center point temperature, high/low-temperature tracking
Palettes| lava, rainbow HC, black hot, white hot, Ironbow, Rainbow
Display type| 2.4″ TFT LCD
Display resolution| 320 x 240
Buttons| 4 buttons (power, up, down, OK) 1 trigger
---|---
Laser| 4(Class 2)
LED Light| √
Temperature alarms| LCD, LED, buzzer
Image storage| Micro SD Card
Image format| BMP
PC analysis software| √
USB communication| Type-C USB
Battery| Li-ion 3.7V/2600mAh 18650
Operating time| Continuous operating time N3h
Charging time| 52.5h
Charging voltage/current| 5V / 2A
Power on speed| Os (wake up) / 5s (power on)
Auto power off| 5min/10min/30min(default)/off
Operating temperature| 0 — 50°C ( 32 — 140°F )
Storage temperature| -20 — 60°C ( -4 — 140°F )
Operating humidity| < 85%RH ( Operating humidity )
IP rating| IP54
Drop proof| 2m
Product size (LXWXH)| 197 x 72 x 60 mm
Product weight| 310g
Certificates| CE, FCC, RoHS
Accessories| User manual, Type-C USB cable,
32GB Micro SD card
Warranty
Triplett / Jewell Instruments extends the following warranty to the original purchaser of these goods for use. Triplett warrants to the original purchaser for use that the products sold by it will be free from defects in workmanship and material for a period of (1) one year from the date of purchase. This warranty does not apply to any of our products that have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as, in our sole judgment, to injure their stability or reliability, or which have been subject to misuse, abuse, misapplication, negligence, accident or which have had the serial numbers altered, defaced, or removed. Accessories, including batteries, are not covered by this warranty