ZEBRA Aurora MV/FIS Configuration Utility User Manual
- June 9, 2024
- ZEBRA
Table of Contents
ZEBRA Aurora MV/FIS Configuration Utility
Description
Product Description
Zebra Aurora™ is a host-side application which allows for the configuration
Zebra FS10, xS20, xS40 and xS70 devices.
Device Compatibility
Zebra Aurora™ can be used to program Zebra MV/FIS devices through these programming modes:
- USB connected cable
- M12 Ethernet
Supported Devices | Supported Device FW |
---|---|
FS40, VS40, FS70, VS70 | CAAESS00-002-R06 |
FS10, FS20, VS20 | CAAFFS00-002-R06 |
Release Notes
This document summarizes the following software release:
Software Version Number | Release Date |
---|---|
V5.0.13000 | February 2023 |
V5.0.13000
RELEASE DATE: FEBRUARY 2023
- Technology Previews
- Aurora and HMI Language Support – Simplified Chinese, Korean, German, French and Spanish
- Expanded ZETI Interface Commands
- Tools
- Deep Learning Based OCR for Fixed Industrial Scanners
- Fully Released – Activated via Licenses
- Performance
- Improvements to deployed job run consistency including Barcode tool timeout, decoding, and trigger timing consistency.
- Level Trigger Enhancements
- Triggered Image Buffering
- UX Improvements
- Backup/Restore/Firmware Upgrade in Aurora
- Device Configuration 1D Parameter Barcode Setup
Known Issues
- Rarely, a barcode tool can sometimes fail on certain images if it follows a machine vision tool.
- Resolution: Move barcode decode tool to run before the machine vision tool.
- When viewing a circle tool that failed in the HMI, it will sometimes cause the HMI to not refresh and will display a blank page.
- Resolution: Use Aurora to inspect the details of a failing circle tool.
- When a user needs to change a device USB IP address, they must first disable the DHCP server option and then re-enable it again afterwards.
- When executing the ZETI command ‘Trigger with result’, after using the ‘Deploy Job’, the trigger command can sometimes fail.
- Resolution: Add a 2 second delay or more after the ‘Deploy Job’ command.
- When using ZETI, any command that has a job slot option, the job slot must be specified for this release.
- The ZETI command line ‘help’ command is not complete. Please refer to ZETI documentation for comprehensive overview of the command set
- When in Edit mode in Aurora, setting the GPIO Hardware Trigger falling edge can cause the trigger to use the rising edge instead.
- Resolution: Set the edge back to rising and then back to falling in the drop-down menu.
- If a device is added to Aurora by IP address, the Aurora Firmware Dual Update will not complete the Dual Update.
- Resolution: Use HMI if Dual Update is required.
- Flaw detection tools have to click ‘Undo’ twice to perform the undo operation.
- When using Aurora for viewing a running barcode job, sometimes decode summary will fail to get updated.
- Resolution: Close the job being viewed and reopen the job again in view mode.
- Device will sometimes not be discoverable in Aurora when starting firmware update in HMI. Device will re-appear once the firmware update completes and reboots
- After updating the firmware, some jobs will not be able to be changed using the HMI.
- Resolution: Run “User Settings” reset in HMI (must be admin)
- Rarely, the HMI may not appear through the display port unless the device is rebooted.
- Autotune will sometimes fail at a range of ~200mm on 2D barcodes only, if illumination is off
- Resolution: Ensure adequate light is available, either with continuous light or enabling the LED lights on the device.
- When generating a backup, if done after setting the time zone, the backup may fail.
- Resolution: Reboot device after time zone change if planning to backup.
- When setting the TCP Heartbeat string in Aurora, nonstandard ASCI characters may cause the heartbeat to not be sent.
- Resolution: Ensure any heartbeat string the user defines uses standard ASCII characters only
- When reordering tools in Aurora that have dependencies on other tools, the reordered tool may not be able to be edited.
- Resolution: Remove and re-add the tool back to the workflow.
- Certain special characters in a job name cause the job results image folder to not allow download from the device.
- Resolution: Use only standard characters for job names
- In some cases, using large number of image banks cause slight delays in processing.
- After upgrading the device firmware, USB options may be grayed out.
- Resolution: Perform User Setting Reset from HMI and update device settings after.
- Firmware update will fail if memory consumption is already high.
- Resolution: Reboot the device and upgrade
- Uninstalling the InstallShield does not always remove all registry entries.
- Resolution: regedit and manually delete Aurora folder under Computer\HKEY_LOCAL_MACHINE\SOFTWARE\Zebra
Release Notes (Previous Releases)
V4.0.22000
RELEASE DATE : DECEMBER 2022
- Added Measure Object Tool
- Added Flaw Detection Edge and Intensity Tools
- Added Object Locate Counting
- Added Image Filters: Gradient, Gradient Horizontal, Vertical and Full
- MV Output Formatting on Supported Interfaces (Global or Interface Specific)
- Added Find and Replace to Barcode Decode Tool
- Improved 1D/2D Barcode Decode Performance
- Setting Barcode Match String via TCP or Serial input
- Added Image Download Capability via HMI
- Enhanced Session Based Triggering for Level, Continuous and Presentation Triggers w/Exit Criteria/Aggregation
- Technology Preview: Device Backup/Restore Functionality
- Performance and Stability Enhancements
V3.1.40000
RELEASE DATE: AUGUST 2022
- Added Reset on Trigger for Do Note Read Same Barcode
- Spanish HID Keyboard support
- Performance and Stability Enhancements
V3.0.10000
RELEASE DATE: JUNE 2022
- Added Edge Counting
- Added Deep-Learning Based OCR Tool (in Beta)
- Added Circle Find Tool
- Added Circle Diameter Measurement Tool
- Added a Circle ROI Type
- Added Open and Close Filters
- Added Erode Filter
- Added RS-232 Input Trigger
- Additional 2D Barcode Performance Improvements
- Added ADF to include Pass/Fail Data Types
- Added ADF to include Barcode Quality Metrics Data
- Performance and Stability Enhancements
V2.0.8000
RELEASE DATE: APRIL 2022
- Performance and Stability Enhancements
V2.0.7000
RELEASE DATE: MARCH 2022
- Performance and Stability Enhancements
- 1D Barcode Quality Metrics
- Added Object Locate Plus
- Added Blob Tools
- Added Binarize Filter/Tool
- Added Dilate Filter/Tool
- ImagePerfect(+) fixes & improvements
- Added Scale Calibration for Distance tool
- Added Advanced Pass/Fail Configuration (AND/OR logic for Job results)
- HID Keyboard Expansion – added French and German KB
- Added support for Codabar symbology
- Added Encoding type (Text/Base64) for ADF Full String data type and added option to show non-printable characters as hex values
- For xS10/20, added external illumination support
- Added “File Path” option when using (S)FTP to Save images
- Added Ability to Open a Local Job (created with emulator) On a Real Connected Camera
V1.200.2001
RELEASE DATE: DECEMBER 2021
- • Performance and Stability Enhancements
- Support for 5MP xS40 and xS70 models
- ImagePerfect(+) for FS models
- Option to output Barcode Location Co-ordinates
- Option to not read last n number of barcodes
- Device can be a TCP/IP Client
- Configurable RS-232 settings
- Ability to configure GPIO Trigger delay
- Support for Fast Hardware Trigger (2.3 MP models only)
- Ability to set GPIOs to static high or low
- Added Job controls to clone, rename and delete jobs
- Support for Conditional Regular expressions for Barcode String Match
- Barcode String Match Regular expression support for ManyCode
- Backwards compatibility of Job files
- Decode and MV statistics in Aurora and HMI stored and queried from device
V1.148.0001
RELEASE DATE: OCTOBER 2021
- Performance Enhancements
- Stability Improvements
- Implementation of licensing error messages in Web HMI
- Fixed issue of Job pausing on refresh of Web HMI
- Fixed issue of crash when clicking on “Communications” tab
- Fixed inability to “View” active Jobs from Job menu when Job utilizes a trigger that is automatic in nature.
- Fixed issue of slow decode rate when “Fast 1D/2D” license is enabled
- Added Configurable TCP/IP – results port and trigger string can be configured
- Support for GPIO > Hardware trigger (normal speed)
- Allow setting a job as Startup / Power up job
- Emulators now have license level
- Supports a total of 21 emulators
- ZJOB backwards compatibility and auto conversion of old job files (Windows only)
- Seamless (live) tool changes when Upgrade licenses are applied
V1.134.0001 – Initial Product Release
RELEASE DATE: JULY 2021
- Bug Fixes
- Stability Improvements
Components
SW Component | Version |
---|---|
InstallShield | 5.0.13000 |
Aurora™ | 5.0.13 |
BSP (xS40/70) | CAAESS00-002-R06 |
BSP (FS10/xS20) | CAAFFS00-002-R06 |
Aurora™ HMI | 2.1.00 |
The components are installed in the following folders:
Component | Location |
---|---|
Application | Program Files\Zebra Technologies\Aurora |
Job/Configuration Files | Users\Public\Documents\ZebraAurora\xSx0\Jobs |
Saved Images | Users\Public\Documents\ZebraAurora\Captures\xSxxxxxx Camera |
Minimum PC Requirements
Component | Location |
---|---|
CPU | Intel or AMD 64-bit processor |
Random Access Memory Files | 4 GB |
GPU | GTX 1030, Intel UHD 620 or equivalent |
Graphics Memory | 2GB |
Disk Space | 4GB free disk space |
Monitor Resolution | 1280 x 800 |
Operating System | Windows 10 |
Internet Connection | Required for software activation |
Installation
Aurora™ can be launched from the Windows 10 Start button.
- Start / All Programs / Zebra Scanner / Zebra Aurora
Read User Manual Online (PDF format)